Search NASA⌕ Search

SEARCH · Search NASA

Results for “BAFFLE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Liquid oxygen sloshing in Space Shuttle External Tank

This paper describes a numerical simulation of the hydrodynamics within the liquid oxygen tank of the Space Shuttle External Tank during liftoff. Before liftoff, the tank is filled with liquid oxygen (LOX) to approximately 97 percent with the other 3 percent containing gaseous oxygen (GOX) and helium. During liftoff, LOX is drained from the bottom of the tank, and GOX is pumped into the tank's ullage volume. There is a delay of several seconds before the GOX reaches the tank which causes the ullage pressure to decrease for several seconds after liftoff; this pressure 'slump' is a common phenomenon in rocket propulsion. When four slosh baffles were removed from the tank, the ullage gas pressure dropped more rapidly than in all previous flights. The purpose of this analysis was to determine whether the removal of the baffles could have caused the increased pressure 'slump' by changing the LOX surface dynamics. The results show that the LOX surface undergoes very high vertical accelerations (up to 5 g) and, therefore, splashing almost certainly occurs. The number of baffles does not affect the surface if the structural motion is assumed; but, the number of baffles may affect the structural motion of the tank.

Kannapel, M. D.↗

Air Flow Around Finned Cylinders

Report presents the results of a study made to determine the air-flow characteristics around finned cylinders. Air-flow distribution is given for a smooth cylinder, for a finned cylinder having several fin spacings and fin widths, and for a cylinder with several types of baffle with various entrance and exit shapes. The results of these tests show: that flow characteristics around a cylinder are not so critical to changes in fin width as they are to fin spacing; that the entrance of the baffle has a marked influence on its efficiency; that properly designed baffles increase the air flow over the rear of the cylinder; and that these tests check those of heat-transfer tests in the choice of the best baffle.

Brevoort, M J↗

Model-Scale Aerodynamic Performance Testing of Proposed Modifications to the NASA Langley Low Speed Aeroacoustic Wind Tunnel

Tests were performed on a 1/20th-scale model of the Low Speed Aeroacoustic Wind Tunnel to determine the performance effects of insertion of acoustic baffles in the tunnel inlet, replacement of the existing collector with a new collector design in the open jet test section, and addition of flow splitters to the acoustic baffle section downstream of the test section. As expected, the inlet baffles caused a reduction in facility performance. About half of the performance loss was recovered by addition the flow splitters to the downstream baffles. All collectors tested reduced facility performance. However, test chamber recirculation flow was reduced by the new collector designs and shielding of some of the microphones was reduced owing to the smaller size of the new collector. Overall performance loss in the facility is expected to be a 5 percent top flow speed reduction, but the facility will meet OSHA limits for external noise levels and recirculation in the test section will be reduced.

Booth, Earl R., Jr.↗

Multiple-Cone Sunshade for a Spaceborne Telescope

A document describes a sunshade assembly for the spaceborne telescope of the Terrestrial Planet Finder Coronagraph mission. During operation, the telescope is aimed at target stars in the semihemisphere away from the Earth's Sun. The observatory rotates about its pointing axis during a single star observation, resulting in relative movement of the Sun. The sunshade assembly protects the telescope against excessive solar-induced thermal distortions for times long enough to complete observations. The assembly includes a cylindrical baffle immediately surrounding the telescope, and a series of coaxial conical shields at half-cone angle increments of between 3 and 6. The black inner surface of the cylindrical baffle suppresses stray light. The outer surface of the cylindrical baffle and all the surfaces of the conical shields except the outermost one are specular and highly reflective in the infrared. The outer surface of the outer shield is a material with low solar absorptance and high infrared emittance, such as silverized Teflon or white paint. This arrangement strongly radiatively couples each shield layer more effectively to cold space than to adjacent shield layers. The result is that the solar-driven temperature gradients in the cylindrical baffle are nearly negated, and only weakly communicated to the highly-infrared-reflective face of the primary telescope mirror.

Cafferty, Terry↗

Optical Coating Performance for Heat Reflectors of the JWST-ISIM Electronic Component

A document discusses a thermal radiator design consisting of lightweight composite materials and low-emittance metal coatings for use on the James Webb Space Telescope (JWST) structure. The structure will have a Thermal Subsystem unit to provide passive cooling to the Integrated Science Instrument Module (ISIM) control electronics. The ISIM, in the JWST observatory, is the platform that provides the mounting surfaces for the instrument control electronics. Dissipating the control electronic generated-heat away from JWST is of paramount importance so that the spacecraft s own heat does not interfere with the infrared-light gathering of distant cosmic sources. The need to have lateral control in the emission direction of the IEC (ISIM Electronics Compartment) radiators led to the development of a directional baffle design that uses multiple curved mirrorlike surfaces. This concept started out from the so-called Winston non-imaging optical concentrators that use opposing parabolic reflector surfaces, where each parabola has its focus at the opposite edge of the exit aperture. For this reason they are often known as compound parabolic concentrators or CPCs. This radiator system with the circular section was chosen for the IEC reflectors because it offers two advantages over other designs. The first is that the area of the reflector strips for a given radiator area is less, which results in a lower mass baffle assembly. Secondly, the fraction of energy emitted by the radiator strips and subsequently reflected by the baffle is less. These fewer reflections reduced the amount of energy that is absorbed and eventually re-emitted, typically in a direction outside the design emission range angle. A baffle frame holds the mirrors in position above a radiator panel on the IEC. Together, these will direct the majority of the heat from the IEC above the sunshield away towards empty space.

Rashford, Robert A.↗

Optical Design of the STAR-X Telescope

Top-level science goals of the Survey and Time-domain Astrophysical Research eXplorer (STAR-X) include: investigations of most violent explosions in the universe, study of growth of black holes across cosmic time and mass scale, and measure how structure formation heats majority of baryons in the universe. To meet these goals, the field-of-view of the telescope should be about 1 square-degree, the angular resolution should be 5 arc-seconds or below across large part of the field-of-view. The on-axis effective area at 1 KeV should be about 2,000 sq cm. Payload cost and launch considerations limit the outer diameter, focal length, and mass to 1.3 meters, 5 meters, and 250 kilograms, respectively. Telescope design is based on a segmented meta-shell approach we have developed at Goddard Space Flight Center for the STAR-X telescope. The telescope shells are divided into 30-degree segments. Individual telescopes and meta-shells are nested inside each other to meet the effective area requirements in 0.5 - 6.0 KeV range. We consider Wolter-Schwarzschild, and Modified-Wolter-Schwarzschild telescope designs as basic building blocks of the nested STAR-X telescope. These designs offer an excellent resolution over a large field of views. Nested telescopes are vulnerable to stray light problems. We have designed a multi-component baffle system to eliminate direct and single-reflection light paths inside the telescopes. Large number of internal and external baffle vane structures are required to prevent stray rays from reaching the focal plane. We have developed a simple ray-trace based tool to determine the dimensions and locations of the baffles. In this paper, we present the results of our trade studies, baffle design studies, and optical performance analyses of the STAR-X telescope.

Saha, Timo T.↗

Design of the STAR-X Telescope

Top-level science goals of the Survey and Time-domain Astrophysical Research eXplorer (STAR-X) include: investigations of most violent explosions in the universe, study of growth of black holes across cosmic time and mass scale, and measure how structure formation heats majority of baryons in the universe. To meet these goals, the field-of-view of the telescope should be about 1 square-degree, the angular resolution should be 5 arc-seconds or below across large part of the field-of-view. The on-axis effective area at 1 KeV should be about 2,000 sq cm. Payload cost and launch considerations limit the outer diameter, focal length, and mass to 1.3 meters, 5 meters, and 250 kilograms, respectively. Telescope design is based on a segmented meta-shell approach we have developed at Goddard Space Flight Center for the STAR-X telescope. The telescope shells are divided into 30-degree segments. Individual telescopes and meta-shells are nested inside each other to meet the effective area requirements in 0.5 - 6.0 KeV range. We consider Wolter-Schwarzschild, and Modified-Wolter-Schwarzschild telescope designs as basic building blocks of the nested STAR-X telescope. These designs offer an excellent resolution over a large field of views. Nested telescopes are vulnerable to stray light problems. We have designed a multi-component baffle system to eliminate direct and single-reflection light paths inside the telescopes. Large number of internal and external baffle vane structures are required to prevent stray rays from reaching the focal plane. We have developed a simple ray-trace based tool to determine the dimensions and locations of the baffles. In this paper, we present the results of our trade studies, baffle design studies, and optical performance analyses of the STAR-X telescope.

Saha, Timo T.↗

Article, component, and method of forming an article

An article and method of forming an article are provided. The article includes a body portion separating an inner region and an outer region, an aperture in the body portion, the aperture fluidly connecting the inner region and the outer region, and a baffle extending along at least a portion of an inner surface of the article, the baffle dividing the inner region into a plurality of sub-regions. The method of forming an article includes forming a body portion defining an inner region and an outer region, forming an aperture in the body portion, the aperture fluidly connecting the inner region to the outer region, and forming at least one baffle extending along at least a portion of an inner surface of the body portion, the at least one baffle dividing the inner region into a plurality of sub-regions. Also provided is a component including a cooling article disposed therein.

42 ENGINEERING↗

Integrated telescope for imaging applications

Integrated telescopes are described that are stable and compact, and include optics pieces that are susceptible to stray light. One example telescope includes an optics piece formed of a transparent optical material and two surfaces with each surface including a reflector surface and a baffle. The baffles may be formed in a groove in one of the surfaces of the optics piece. The baffle may have an index of refraction that is approximately the same as an index of refraction of the optics piece. The baffle may include a blackened epoxy, a carbon black material, or a powdered black spinel. The integrated telescope may include a short-wave infrared image sensor fixed in position relative to the optics piece.

Bauman, Brian↗

Towards improved neutral exhaust in the HSX stellarator

To improve our knowledge of neutral exhaust in non-resonant divertors, a particle exhaust study is performed for the Helically Symmetric eXperiment (HSX). The chaotic magnetic field topology in the plasma edge is examined with connection lengths and Lyapunov exponents. Plasma flux tubes are identified and these flux tubes deposit particles onto plasma facing components. This helps determine the areas where neutrals are generated and provides guidance on where to put baffles. As shown using EMC3-EIRENE simulations, the introduction of baffles can help increase the neutral pressure at and away from the strike line locations. Furthermore, it is demonstrated that baffle design cannot only be based on placing structures at locations with small connection lengths.

Baffles↗

Design of a Novel Variable Geometry Divertor for Tokamaks

The divertor is a key component of fusion reactors, allowing exhaust of gas, impurities, and helium ash to preserve plasma purity. The divertor geometry strongly affects plasma performance, and it is designed to be compatible with different plasma shapes in present-day fusion experiments. Here, we present a novel concept for a variable geometry divertor, in which the divertor baffle tiles are reorientable by external actuation. Implementation of this concept in a medium-sized research tokamak would uniquely provide the flexibility to tailor divertor geometry to the plasma configuration and also enable study of the effect of divertor closure on plasma performance. To ensure compatibility with typical tokamak operations, the adjustable divertor must withstand the effects of significant mechanical and thermal stresses such as MW/m 2 -scale heat fluxes and large electromagnetic fields, e.g., disruption forces. The technological solutions for actuation mechanisms, cooling system, gas baffling and plasma-facing components are assessed. A functional reduced-scale model with movable outer divertor target baffle tiles is developed and the actuation mechanism is tested.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ELAWD GROUT HOPPER MOCK-UP TESTING

A 10-inch READCO mixer is used for mixing the premix (45 (wt%) fly ash, 45 wt% slag, and 10 wt% portland cement) with salt solution in the Saltstone Production Facility (SPF). The Saltstone grout free falls into the grout hopper which feeds the suction line leading to the Watson SPX 100 duplex hose pump. The Watson SPX 100 pumps the grout through approximately 1500 feet of piping prior to being discharged into the Saltstone Disposal Facility (SDF) vaults. The existing grout hopper has been identified by the Saltstone Enhanced Low Activity Waste Disposal (ELAWD) project for re-design. The current nominal working volume of this hopper is 12 gallons and does not permit handling an inadvertent addition of excess dry feeds. Saltstone Engineering has proposed a new hopper tank that will have a nominal working volume of 300 gallons and is agitated with a mechanical agitator. The larger volume hopper is designed to handle variability in the output of the READCO mixer and process upsets without entering set back during processing. The objectives of this task involve scaling the proposed hopper design and testing the scaled hopper for the following processing issues: (1) The effect of agitation on radar measurement. Formation of a vortex may affect the ability to accurately measure the tank level. The agitator was run at varying speeds and with varying grout viscosities to determine what parameters cause vortex formation and whether measurement accuracy is affected. (2) A dry feeds over addition. Engineering Calculating X-ESR-Z-00017 1 showed that an additional 300 pounds of dry premix added to a 300 gallon working volume would lower the water to premix ratio (W/P) from the nominal 0.60 to 0.53 based on a Salt Waste Processing Facility (SWPF) salt simulant. A grout with a W/P of 0.53 represents the upper bound of grout rheology that could be processed at the facility. A scaled amount of dry feeds will be added into the hopper to verify that this is a recoverable situation. (3) The necessity of baffles in the hopper. The preference of the facility is not to have baffles in the hopper; however, if the initial testing indicates inadequate agitation or difficulties with the radar measurement, baffles will be tested.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Investigation of the Ranger V-770-8 Engine Installation for the Edo XOSE-1 Airplane I : Cooling

Engine temperature data and cooling correlating analyses of the engine and oil cooler are presented in connection with an investigation of the cowling and cooling of the ranger V-770-8 engine installation in the Edo XOSE-1 airplane. Three types of baffles were installed in the course of the tests: the conventional, the turbulent-flow, and the NACA diffuser baffles. Each of the types was of merit in cooling a different region on the cylinder. Incorporation of the best features of the three types into one baffle, a method which appears to be feasible, would provide improvements in cylinder cooling.

COOLING TESTS↗

Reactor Vessel and Reactor Vessel Internals Segmentation at Zion Nuclear Power Station - 13230

Zion Nuclear Power Station (ZNPS) is a dual-unit Pressurized Water Reactor (PWR) nuclear power plant located on the Lake Michigan shoreline, in the city of Zion, Illinois approximately 64 km (40 miles) north of Chicago, Illinois and 67 km (42 miles) south of Milwaukee, Wisconsin. Each PWR is of the Westinghouse design and had a generation capacity of 1040 MW. Exelon Corporation operated both reactors with the first unit starting production of power in 1973 and the second unit coming on line in 1974. The operation of both reactors ceased in 1996/1997. In 2010 the Nuclear Regulatory Commission approved the transfer of Exelon Corporation's license to ZionSolutions, the Long Term Stewardship subsidiary of EnergySolutions responsible for the decommissioning of ZNPS. In October 2010, ZionSolutions awarded Siempelkamp Nuclear Services, Inc. (SNS) the contract to plan, segment, remove, and package both reactor vessels and their respective internals. This presentation discusses the tools employed by SNS to remove and segment the Reactor Vessel Internals (RVI) and Reactor Vessels (RV) and conveys the recent progress. SNS's mechanical segmentation tooling includes the C-HORCE (Circumferential Hydraulically Operated Cutting Equipment), BMT (Bolt Milling Tool), FaST (Former Attachment Severing Tool) and the VRS (Volume Reduction Station). Thermal segmentation of the reactor vessels will be accomplished using an Oxygen- Propane cutting system. The tools for internals segmentation were designed by SNS using their experience from other successful reactor and large component decommissioning and demolition (D and D) projects in the US. All of the designs allow for the mechanical segmentation of the internals remotely in the water-filled reactor cavities. The C-HORCE is designed to saw seven circumferential cuts through the Core Barrel and Thermal Shield walls with individual thicknesses up to 100 mm (4 inches). The BMT is designed to remove the bolts that fasten the Baffle Plates to the Baffle Former Plates. The FaST is designed to remove the Baffle Former Plates from the Core Barrel. The VRS further volume reduces segmented components using multiple configurations of the 38i and horizontal reciprocating saws. After the successful removal and volume reduction of the Internals, the RV will be segmented using a 'First in the US' thermal cutting process through a co-operative effort with Siempelkamp NIS Ingenieurgesellschaft mbH using their experience at the Stade NPP and Karlsruhe in Germany. SNS mobilized in the fall of 2011 to commence execution of the project in order to complete the RVI segmentation, removal and packaging activities for the first unit (Unit 2) by end of the 2012/beginning 2013 and then mobilize to the second unit, Unit 1. Parallel to the completion of the segmentation of the reactor vessel internals at Unit 1, SNS will segment the Unit 2 pressure vessel and at completion move to Unit 1. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling a divertor with mid-leg pumping for high-power H-mode scenarios in DIII-D considering E x B drift flows

Edge-plasma simulations of a baffled, long-legged divertor in DIII-D, performed using the multi-fluid code UEDGE, indicate that the position of the detachment front is constrained to the location of the pump duct along the low-field side (LFS) baffle. Simulations including magnetic and E x B drifts were performed for 12.5 MW deuterium plasmas including intrinsic carbon and seeded neon to assess the optimal location of the LFS divertor pump to create a stable detachment front between the target and the X-point. The radiation front position in the simulations, taken to be indicative of the detachment front, can be controlled between the pump and X-point in the favorable magnetic field direction for H-mode access by moving the pump duct location upstream of the target along the LFS baffle. In the unfavorable magnetic field direction, the radial E θ x B drift flows are directed towards the pumping surface, efficiently removing the injected deuterium gas and limiting the sensitivity of the radiation front location to the gas injection rate. The role of pumping rate and drift direction on the pumping efficiency are also found to affect the divertor plasma conditions and detachment front location in UEDGE simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

New insights on divertor parallel flows,E × B drifts, and fluctuations from in situ, two-dimensional probe measurement in the Tokamak à Configuration Variable

Abstract In situ , two-dimensional (2D) Langmuir probe measurements across a large part of the TCV outer divertor are reported in L-mode discharges with and without divertor baffles. This provides detailed insights into time averaged profiles, particle fluxes, and fluctuation behavior in different divertor regimes. The presence of the baffles is shown to substantially increase the divertor neutral pressure for a given upstream density and to facilitate the access to detachment, an effect that increases with plasma current. The detailed, 2D probe measurements allow for a divertor particle balance, including ion flux contributions from parallel flows and E × B drifts. The poloidal flux contribution from the latter is often comparable or even larger than the former, and the divertor parallel flow direction reverses in some conditions, pointing away from the target. In most conditions, the integrated particle flux at the outer target can be predominantly ascribed to ionization along the outer divertor leg, consistent with a closed-box approximation of the divertor. The exception is a strongly detached divertor, achieved here only with baffles, where the total poloidal ion flux even decreases towards the outer target, indicative of significant plasma recombination. The most striking observation from relative density fluctuation measurements along the outer divertor leg is the transition from poloidally uniform fluctuation levels in attached conditions to fluctuations strongly peaking near the X-point when approaching detachment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulation of Liquid Lithium Divertor Geometry Using SOLPS-ITER

Here, plasma-facing component (PFC) geometries are evaluated for a Fusion Nuclear Science Facility (FNSF) design to find solutions that are compatible with flowing liquid lithium components while satisfying requirements from the perspective of plasma and neutral particle transport. Flowing liquid metal (LM) divertor systems offer important advantages due to continual regeneration of the surface material, but may require modifications from standard optimized tokamak divertor designs. Scrape Off Layer Plasma Simulator for the International Thermonuclear Experimental Reactor (SOLPS-ITER) simulations are used to compare standard vertical target, open, and balanced baffled geometries. It is found that the open geometry offers little control of neutral particles and has narrow operating windows where the divertor fluxes can be lowered to acceptable levels, while maintaining the required upstream density. The addition of neutral baffles allows greater control over the divertor conditions with less impact on the upstream density. The divertor neutral pressure in the baffled geometry is slightly higher than the open divertor, but not as large with a vertical target. A first-pass coupling of the SOLPS solution with sheath and implantation/erosion models to compute the lithium emission shows that the lithium is largely confined to the near-surface region due to the small ionization mean free path and large main ion flow toward the surface. The lithium source was varied by three orders of magnitude. At the highest rate, when the sourced lithium approaches the level of the main ion recycling flux, a high core lithium concentration (~10%) is observed with only moderate power dissipation to affect the divertor plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Background-Oriented Schlieren Velocimetry of Helium Coolant Flow in Additively Manufactured Channels

High-pressure helium gas cooling is an attractive solution for thermal management of the fusion blanket first wall, as this coolant is chemically and neutronically inert and separable from hydrogenic species. However, due to the low thermal mass of helium, geometric optimization of these channels is required to provide sufficient cooling at manageable flow rates and pumping burdens. Increasingly, analysis and optimization of these coolant channels rely on computational fluid dynamics (CFD) simulations, and these require relevant experimental data for turbulence model validation. Toward this end, a high-pressure helium gas flow visualization system has been employed to image the flow of helium in flow channels with one-sided heating, mimicking the blanket first wall environment. Flow of helium at 4 MPa pressure and flow rates up to 68 g/s (Reynolds number 57 000) is supplied to rectangular channel test sections, with uniform heating applied to the bottom wall of the channel at heat fluxes varied between roughly 50 and 130 kW/m2. A high-speed camera is used to image index of refraction (IOR) gradients in the fluid via background-oriented schlieren (BOS), and temperature and pressure instrumentation are used to characterize thermal-hydraulic performance of each channel. Cross correlation of time-resolved BOS images is then used to calculate time-averaged 2-D helium velocity fields. Flow in additively manufactured (AM) channels is examined in this manner, including both featureless channels and those containing baffling as a heat transfer enhancement. The flow distribution seen in the featureless case differs significantly from that seen in prior simulations, whereas the flow in the baffled case shows the predicted behavior of flow forced along the heated wall. This augmented flow distribution is seen to increase the heat transfer coefficient in the baffled test section. Here, strategies are discussed for ongoing and future validation of these simulations, with the aim of model deployment for blanket cooling design and optimization.

Additive manufacturing↗