Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAMS, RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Documentation of the solar radiation parameterization in the GLAS climate model

The parameterization of solar radiation in the Goddard Laboratory for atmospheric sciences (GLAS) general circulation model (GCM) is described. It explicitly considers the directional nature of the direct solar beam in treating radiative transfer within clouds, and in treating the effect of surface reflection. This is accomplished using delta Eddington and delta 2 stream models for the radiative transfer within isolated atmospheric layers, and by coupling the individual layers together by efficiently repeated applications of the interaction principle.

Davies, R.↗

One-Dimensional Simulation of Isotropic Radiation

Solar cells tested for effects of radiation in unidirectional beam. Cam groove imparts cosecant-function velocity to solar cells on rotating target plate. Cells on stationary plate above rotating one absorb steady perpendicular radiation from test source.

Anspaugh, B. E.↗

Charging of Single Micron Sized Dust Grains by Secondary Electron Emission: A Laboratory Study

We present the details of a new laboratory study whose objective is to experimentally study the interaction of micron sized particles with plasmas and electromagnetic radiation. Specifically, to investigate under what conditions and to what extent do particles of various compositions and sizes become charged, or discharged, while exposed to an electron beam and ultraviolet radiation environment The emphasis is the study of the two charging mechanisms, secondary emission of electrons and photoelectric effect. The experiment uses a technique known as electrodynamic suspension of particles. With this technique, a single charged particle is electrodynamically levitated and then exposed to a controlled environment. Its charge to mass ratio is directly measured. Viscous drag measurements and the light scattering measurements characterize its size and optical characteristics. The environment to which the particle is expose may consist of room temperature and pressure or a rarefied atmosphere where only one major gaseous constituent is present, or, as in this case, a vacuum environment under electron bombardment or UV radiation . In addition, the environment can be cycled as part of the experiment. Therefore, using this technique, a single particle can be repeatedly exposed to a controlled environment and its response measured, or a single particle can be exposed to similar environments with minor differences and its response measured as a function of only the changed environmental conditions.

Spann, James F., Jr.↗

A beaming model of the Io-independent Jovian decameter radiation based on multipole models of the Jovian magnetic field

A geometrical model is presented in which the apparent source locations of the Io-independent decameter radiation are computed. The calculations assume that the radiation is produced by stably trapped electrons radiating near the electron gyrofrequency and that the emission is then beamed onto a conical surface. The maximum occurrence probability of noise storms is associated with regions in the Jovian magnetosphere where the axis of the emission cone is most inclined toward the Jovian equatorial plane. The calculations utilize and compare two of the octupole spherical harmonic expansions of the Jovian magnetic field constructed from data accumulated by the fluxgate and vector helium magnetometers on board Pioneer 11.

Goldstein, M. L.↗

E-Beam Processing of Polymer Matrix Composites for Multifunctional Radiation Shielding

Aliphatic polymers were identified as optimum radiation shielding polymeric materials for building multifunctional structural elements for in-space habitats. Conceptual damage tolerant configurations of polyolefins have been proposed, but many manufacturing issues relied on methods and materials which have sub-optimal radiation shielding characteristics (for example, epoxy matrix and adhesives). In the present approach, we shall investigate e-beam processing technologies for inclusion of high-strength aliphatic polymer reinforcement structures into a highly cross-linked polyolefin matrix. This paper reports the baseline thermo-mechanical properties of low density polyethylene and highly crystallized polyethylene.

Hou, Tan-Hung↗

Monitoring technology

A process for infrared spectroscopic monitoring of insitu compositional changes in a polymeric material comprises the steps of providing an elongated infrared radiation transmitting fiber that has a transmission portion and a sensor portion, embedding the sensor portion in the polymeric material to be monitored, subjecting the polymeric material to a processing sequence, applying a beam of infrared radiation to the fiber for transmission through the transmitting portion to the sensor portion for modification as a function of properties of the polymeric material, monitoring the modified infrared radiation spectra as the polymeric material is being subjected to the processing sequence to obtain kinetic data on changes in the polymeric material during the processing sequence, and adjusting the processing sequence as a function of the kinetic data provided by the modified infrared radiation spectra information.

Stevenson, William A.↗

Monitoring technology

A process for infrared spectroscopic monitoring of insitu compositional changes in a polymeric material comprises the steps of providing an elongated infrared radiation transmitting fiber that has a transmission portion and a sensor portion, embedding the sensor portion in the polymeric material to be monitored, subjecting the polymeric material to a processing sequence, applying a beam of infrared radiation to the fiber for transmission through the transmitting portion to the sensor portion for modification as a function of properties of the polymeric material, monitoring the modified infrared radiation spectra as the polymeric material is being subjected to the processing sequence to obtain kinetic data on changes in the polymeric material during the processing sequence, and adjusting the processing sequence as a function of the kinetic data provided by the modified infrared radiation spectra information.

Stevenson, William A.↗

A beaming model of the Io-independent Jovian decameter radiation based on multipole models of the Jovian magnetic field

A geometrical model is presented in which the apparent source locations of the Io-independent decameter radiation are computed. The calculations assume that the radiation is produced by stably trapped electrons radiating near the local electron gyrofrequency and that the emission is then beamed onto a conical surface. The maximum occurrence probability of noise storms is associated with regions in the Jovian magnetosphere where the axis of the emission cone is most inclined toward the Jovian equatorial plane. The calculations utilize and compare two of the octopole spherical harmonic expansions of the Jovian magnetic field constructed from data accumulated by the fluxgate and vector helium magnetometers on board Pioneer 11.

Goldstein, M. L.↗

The Galactic Cosmic Ray Simulator at the NASA Space Radiation Research Laboratory

With NASA’s new Artemis plan for a sustainable return to the moon, astronauts will once again leave Earth’s protective magnetosphere only to endure higher levels of radiation from galactic cosmic radiation (GCR). The ever penetrating GCR will continue to pose significant health risks especially as lunar missions increase in duration and as NASA sets its aspirations on Mars. The primary risks of concern include carcinogenesis, central nervous system (CNS) effects resulting in potential in-mission cognitive or behavioral impairment and/or late neurological disorders, and degenerative tissue effects including circulatory and heart disease. Characterization and mitigation of these risks requires a significant reduction in the large biological uncertainties of chronic (low-dose rate) heavy ion exposures and the validation of countermeasures in a relevant space environment. Historically, most research on understanding space radiation-induced health risks has been performed using acute exposures of monoenergetic single-ion beams. However, the space radiation environment consists of a wide variety of ion species over a broad energy range. Using the fast beam switching and controls systems technology recently developed at the NASA Space Radiation Laboratory at Brookhaven National Laboratory, a new era in radiobiological research is possible. NASA has developed the “GCR simulator” to generate a spectrum of ion beams that approximates the primary and secondary GCR field experienced at human organ locations within a deep-space vehicle.

NASA Space Radiation Laboratory↗

Measurement of plasma temperature and density using radiation absorption

A light beam of predetermined wavelength, preferably monochromatic, is directed through a plasma to be measured. The absorption of the light by the plasma is detected for deriving an absorption coefficient of the plasma. Knowing the absorption coefficient of the plasma and independently measuring either the electron density or temperature of the plasma allows solution of an equation to derive the other unknown quantity, i.e. either electron density or temperature. In a preferred method, the absorption coefficient of the plasma is derived simultaneously for two probing light beams of substantially different predetermined wave-lengths. Knowing these two coefficients allows solution of two simultaneous equations to derive the electron density and temperature of the plasma.

Kenneth W Billman↗

BL Lac objects and relativistic beaming

General arguments for relativistic beaming in BL Lac objects are reviewed. These include overproduction of X-rays and fast time variability. Comments are made about the relationship of the X-ray continuum to that at lower frequencies, and observational evidence for and against continuum radiation being relativistically beamed is discussed. Finally, there is discussion of the influence of geometrical effects on predictions for time variability as a function of frequency in the context of inhomogeneous synchrotron self-Compton jet models.

Worrall, Diana M.↗

Inverse Compton scattering of ambient radiation by a cold relativistic jet - A source of beamed, polarized continuum in blazars?

A general formalism is developed for computing the intensity and polarization of unpolarized radiation scattered by a group of electrons with a specified distribution of momenta. The case of isotropic incident radiation with a power-law spectrum is addressed, and the 'head-on' approximation is developed to describe the nearly unidirectional character of the incident radiation in the electron rest frame. The formalism is implemented numerically, verifying the validity of the 'head-on' approximation and illustrating the polarization and intensity properties of radiation scattered by jets with different electron momentum distribution. The results are placed in an astrophysical setting, determining the optical depths and kinetic energies required for the scattered radiation to dominate over the isotropic component in blazars. It is argued that Comptonization of unbeamed AGN radiation by a relativistic jet can account for the polarization and the overall spectral shape of the IR-optical continuum in blazars.

Begelman, Mitchell C.↗

Phased Array Radiometer Calibration Using a Radiated Noise Source

Electronic beam steering capability of phased array antenna systems offer significant advantages when used in real aperture imaging radiometers. The sensitivity of such systems is limited by the ability to accurately calibrate variations in the antenna circuit characteristics. Passive antenna systems, which require mechanical rotation to scan the beam, have stable characteristics and the noise figure of the antenna can be characterized with knowledge of its physical temperature [1],[2]. Phased array antenna systems provide the ability to electronically steer the beam in any desired direction. Such antennas make use of active components (amplifiers, phase shifters) to provide electronic scanning capability while maintaining a low antenna noise figure. The gain fluctuations in the active components can be significant, resulting in substantial calibration difficulties [3]. In this paper, we introduce two novel calibration techniques that provide an end-to-end calibration of a real-aperture, phased array radiometer system. Empirical data will be shown to illustrate the performance of both methods.

Srinivasan, Karthik↗

System for Transmitting and Receiving Electromagnetic Radiation

A system for transmitting and receiving electromagnetic radiation includes a beam splitter and a transceiver. The beam splitter is configured to separate an optical pulse into a pump pulse and a probe pulse. The transceiver may include a transmitter switch and a receiver switch. The pump pulse is directed toward the transmitter switch and the probe pulse is directed towards the receiver switch. Electromagnetic radiation is emitted from the transceiver when the pump pulse strikes the transmitter switch. The electromagnetic radiation may be terahertz radiation in either a pulsed or continuous wave form.

Strong, Timothy↗

Gamma-ray burst spectral breaks and source beaming

The principal discovery of the Compton Gamma-Ray Observatory (GRO) concerning gamma-ray bursts is that these sources are isotropic but with a comparative deficiency of fainter sources, suggesting that they are probably cosmological in origin. If they are at such large distances from Earth then they are extremely luminous and compact. A consequence of this is that two-photon pair production attenuation of the gamma-ray continuum cannot be avoided unless the source radiation is substantially beamed. Most sources do not display gamma-ray turnovers although a few gamma-ray bursts (GRB) detected by GRO exhibit distinct spectral breaks in the MeV range. A derivation of the relationship defining of the degree of beaming in burst sources with spectral breaks due to gamma-gamma attenuation, as a function of source spectral index and break energy, is presented. It is found that sources at distances of approximately 1 Gpc must typically be beamed with bulk Lorentz factors of around 10(exp 3)-10(exp 4), indicating powerful bulk acceleration in bursts, although these Lorentz factors are reduced markedly for steep source spectra. Since the source spectra are not strongly Comptonized, such beaming will blueshift the gamma-gamma attenuation breaks to energies much higher than 1 MeV; an absolute lower bound to the source bulk Lorentz factor is determined from this additional constraint. This blueshifting suggests that those sources with MeV breaks may not be cosmological, or that their breaks are produced by a mechanism that dominates gamma-gamma attenuation at these energies.

Baring, Matthew G.↗