At least 235 records · Page 13

The subscale orbital fluid transfer experiment

The Subscale Orbital Fluid Transfer Experiment (SOFTE) is a planned Shuttle Orbiter fluid transfer experiment. CASP (Center for Advanced Space Propulsion) performed certain aspects of the conceptual design of this experiment. The CASP work consisted of the conceptual design of the optical system, the search for alternative experimental fluids, the determination of the flow meter specifications and the examination of materials to use for a bladder that will empty one of the tanks in the experiment.

Collins, Frank G.↗

Development of an In-Flight Refill Unit for Replenishing Research Animal Drinking Water

The Spacelab Life Sciences 2 (SLS-2) mission became NASA's longest duration Shuttle mission, lasting fourteen days, when Columbia landed on 1 Nov. 1993. Located within the Spacelab were a total of 48 laboratory rats which were housed in two Research Animal Holding Facilities (RAHF's) developed by the Space Life Sciences Payloads Office (SLSPO) at Ames Research Center. In order to properly maintain the health and well-being of these important research animals, sufficient quantities of food and water had to be available for the duration of the mission. An inflight Refill Unit was developed by the SLSPO to replenish the animals' drinking water inflight using the Shuttle potable water system in the middeck galley as the source of additional water. The Inflight Refill Unit consists of two major subsystems, a Fluid Pumping Unit (FPU) and a Collapsible Water Reservoir (CWR). The FPU provides the system measurement and controls, pump, water lines, and plumbing necessary to collect water coming into the unit from the potable water system and pump it out and into the RAHF drinking water tanks. The CWR is a Kevlar(trademark) reinforced storage bladder, connected to the FPU, which has a capacity of 6 liters in its expanded volume and functions to store the water collected from the potable water system and allows for the transport of the water back to the Spacelab where it is pumped into each of two RAHFs. Additional components of the FPU system include the inlet and outlet fluid hoses, a power cable for providing 28 volt direct current spacecraft electrical power to the pump within the FPU, a tether system for the unit when in use in Spacelab, and an adapter for mating the unit to the orbiter waste collection system in order to dump excess water after use in Spacelab. This paper will present the design process and development approach for the lnflight Refill Unit, define some of the key design issues which had to be addressed, and summarize the inflight operational performance of the unit during the SLS-2 mission.

Savage, P. D.↗

TransHab Materials Selection

A viewgraph presentation gives an overview of the materials selection for the TransHab, the habitation module on the International Space Station (ISS). Details are given on the location of TransHab on the ISS, the multilayer inflatable shell that surrounds the module, the materials requirements (including information on the expected thermal environment), the materials selection challenges, the bladder materials requirements and testing, and meteoroid/debris shielding material.

Pedley, M. D.↗

Spinal Bracing

Dr. Arthur Copes of the Copes Foundation, Baton Rouge, LA, says that 35 percent of the 50 technical reports he received from the NASA/Southern University Industrial Applications Center in Baton Rouge and the Central Industrial Applications Center, Durant, OK, were vital to the development of his Copes Scoliosis Braces, which are custom designed and feature a novel pneumatic bladder that exerts constant corrective pressure to the torso to slowly reduce or eliminate the spinal curve.

Source record↗

Protecting Space Travelers from Kidney Stones: Renal Stone Risk During Space Flight

Renal stones, popularly known as kidney or bladder stones, are small rock-like objects formed in the kidneys or urinary tract by deposits of calcium and other minerals. The problem arises when the stones block the drainage of the kidney, resulting in urinary obstruction and pain. Passing these stones can be one of the most painful experiences a person will endure so doctors often prescribe pain relievers to ease the experience. Drinking plenty of fluids, which help flush waste out of the body, and eating a well-balanced diet are the first steps to preventing stones. For individuals at risk, this may not be enough, and a doctor may recommend a special diet and medications. Unfortunately, approximately 60 percent of people who have had a renal stone will experience a recurrence. This is particularly true of men, who are four to five times more likely to develop stones than women. Renal stones do not discriminate based on age; even children are at risk. Astronauts are particularly at risk of developing renal stones because they lose bone and muscle mass; calcium, other minerals, and protein normally used for bone and muscle end up in the bloodstream and then in the kidneys. Without plenty of fluid to wash them away, crystals can form and then grow into stones. This factor compounds the risk for astronauts, since they also perceive that they are less thirsty in space and will drink less than normal during the mission. To minimize all of these factors, doctors must instead treat the stone-forming compounds with medication. This study will use potassium citrate to reduce the risk of stone formation. Renal stones are never convenient, but they are a particular concern for astronauts who have limited access to treatment during flight. Researchers are examining how earthbound preventions for renal stone formation work in flight, ensuring missions are not ended prematurely due to this medical condition. During STS-107, earthbound preventions and treatments become astronauts' gain.

Whitson, Peggy↗

Collapsible Cryogenic Storage Vessel Project

Collapsible cryogenic storage vessels may be useful for future space exploration missions by providing long-term storage capability using a lightweight system that can be compactly packaged for launch. Previous development efforts have identified an 'inflatable' concept as most promising. In the inflatable tank concept, the cryogen is contained within a flexible pressure wall comprised of a flexible bladder to contain the cryogen and a fabric reinforcement layer for structural strength. A flexible, high-performance insulation jacket surrounds the vessel. The weight of the tank and the cryogen is supported by rigid support structures. This design concept is developed through physical testing of a scaled pressure wall, and through development of tests for a flexible Layered Composite Insulation (LCI) insulation jacket. A demonstration pressure wall is fabricated using Spectra fabric for reinforcement, and burst tested under noncryogenic conditions. An insulation test specimens is prepared to demonstrate the effectiveness of the insulation when subject to folding effects, and to examine the effect of compression of the insulation under compressive loading to simulate the pressure effect in a nonrigid insulation blanket under the action atmospheric pressure, such as would be seen in application on the surface of Mars. Although pressure testing did not meet the design goals, the concept shows promise for the design. The testing program provides direction for future development of the collapsible cryogenic vessel concept.

Fleming, David C.↗

Radiation-induced second cancers: the impact of 3D-CRT and IMRT

Information concerning radiation-induced malignancies comes from the A-bomb survivors and from medically exposed individuals, including second cancers in radiation therapy patients. The A-bomb survivors show an excess incidence of carcinomas in tissues such as the gastrointestinal tract, breast, thyroid, and bladder, which is linear with dose up to about 2.5 Sv. There is great uncertainty concerning the dose-response relationship for radiation-induced carcinogenesis at higher doses. Some animal and human data suggest a decrease at higher doses, usually attributed to cell killing; other data suggest a plateau in dose. Radiotherapy patients also show an excess incidence of carcinomas, often in sites remote from the treatment fields; in addition there is an excess incidence of sarcomas in the heavily irradiated in-field tissues. The transition from conventional radiotherapy to three-dimensional conformal radiation therapy (3D-CRT) involves a reduction in the volume of normal tissues receiving a high dose, with an increase in dose to the target volume that includes the tumor and a limited amount of normal tissue. One might expect a decrease in the number of sarcomas induced and also (less certain) a small decrease in the number of carcinomas. All around, a good thing. By contrast, the move from 3D-CRT to intensity-modulated radiation therapy (IMRT) involves more fields, and the dose-volume histograms show that, as a consequence, a larger volume of normal tissue is exposed to lower doses. In addition, the number of monitor units is increased by a factor of 2 to 3, increasing the total body exposure, due to leakage radiation. Both factors will tend to increase the risk of second cancers. Altogether, IMRT is likely to almost double the incidence of second malignancies compared with conventional radiotherapy from about 1% to 1.75% for patients surviving 10 years. The numbers may be larger for longer survival (or for younger patients), but the ratio should remain the same.

Review, Tutorial↗

Probability of cell hits in selected organs and tissues by high-LET particles at the ISS orbit

The fluence of high-LET particles (HLP) with LET infinity H2O greater than 15 keV micrometers-1 in selected organs and tissues were measured with plastic nuclear track detectors using a life-size human phantom on the 9th Shuttle-Mir Mission (STS-91). The planar-track fluence of HLP during the 9.8-day mission ranged from 1.9 x 10(3) n cm-2 (bladder) to 5.1 x 10(3) n cm-2 (brain) by a factor of 2.7. Based on these data, a probability of HLP hits to a matured cell of each organ or tissue was roughly estimated for a 90-day ISS mission. In the calculation, all cells were assumed to be spheres with a geometric cross-sectional area of 500 micrometers2 and the cell-hit frequency from isotropic space radiation can be described by the Poisson-distribution function. As results, the probability of one or more than 1 hit to a single cell by HLP for 90 days ranged from 17% to 38%; that of two or more than 2 hits was estimated to be 1.3-8.2%. c2002 COSPAR. Published by Elsevier Science Ltd. All rights reserved.

NASA Discipline Radiation Health↗

Multimodality stereotactic brain tissue identification: the NASA smart probe project

Real-time tissue identification can benefit procedures such as stereotactic brain biopsy, functional neurosurgery and brain tumor excision. Optical scattering spectroscopy has been shown to be effective at discriminating cancer from noncancerous conditions in the colon, bladder and breast. The NASA Smart Probe extends the concept of 'optical biopsy' by using neural network techniques to combine the output from 3 microsensors contained within a cannula 2. 7 mm in diameter (i.e. the diameter of a stereotactic brain biopsy needle). Experimental data from 5 rats show the clear differentiation between tissues such as brain, nerve, fat, artery and muscle that can be achieved with optical scattering spectroscopy alone. These data and previous findings with other modalities such as (1) analysis of the image from a fiberoptic neuroendoscope and (2) the output from a microstrain gauge suggest the Smart Probe multiple microsensor technique shows promise for real-time tissue identification in neurosurgical procedures. Copyright 2000 S. Karger AG, Basel.

Non-programmatic↗

Risk cross sections and their application to risk estimation in the galactic cosmic-ray environment

Radiation risk cross sections (i.e. risks per particle fluence) are discussed in the context of estimating the risk of radiation-induced cancer on long-term space flights from the galactic cosmic radiation outside the confines of the earth's magnetic field. Such quantities are useful for handling effects not seen after low-LET radiation. Since appropriate cross-section functions for cancer induction for each particle species are not yet available, the conventional quality factor is used as an approximation to obtain numerical results for risks of excess cancer mortality. Risks are obtained for seven of the most radiosensitive organs as determined by the ICRP [stomach, colon, lung, bone marrow (BFO), bladder, esophagus and breast], beneath 10 g/cm2 aluminum shielding at solar minimum. Spectra are obtained for excess relative risk for each cancer per LET interval by calculating the average fluence-LET spectrum for the organ and converting to risk by multiplying by a factor proportional to R gamma L Q(L) before integrating over L, the unrestricted LET. Here R gamma is the risk coefficient for low-LET radiation (excess relative mortality per Sv) for the particular organ in question. The total risks of excess cancer mortality obtained are 1.3 and 1.1% to female and male crew, respectively, for a 1-year exposure at solar minimum. Uncertainties in these values are estimated to range between factors of 4 and 15 and are dominated by the biological uncertainties in the risk coefficients for low-LET radiation and in the LET (or energy) dependence of the risk cross sections (as approximated by the quality factor). The direct substitution of appropriate risk cross sections will eventually circumvent entirely the need to calculate, measure or use absorbed dose, equivalent dose and quality factor for such a high-energy charged-particle environment.

NASA Discipline Radiation Health↗

Intramuscular pressures beneath elastic and inelastic leggings

Leg compression devices have been used extensively by patients to combat chronic venous insufficiency and by astronauts to counteract orthostatic intolerance following spaceflight. However, the effects of elastic and inelastic leggings on the calf muscle pump have not been compared. The purpose of this study was to compare in normal subjects the effects of elastic and inelastic compression on leg intramuscular pressure (IMP), an objective index of calf muscle pump function. IMP in soleus and tibialis anterior muscles was measured with transducer-tipped catheters. Surface compression between each legging and the skin was recorded with an air bladder. Subjects were studied under three conditions: (1) control (no legging), (2) elastic legging, and (3) inelastic legging. Pressure data were recorded for each condition during recumbency, sitting, standing, walking, and running. Elastic leggings applied significantly greater surface compression during recumbency (20 +/- 1 mm Hg, mean +/- SE) than inelastic leggings (13 +/- 2 mm Hg). During recumbency, elastic leggings produced significantly higher soleus IMP of 25 +/- 1 mm Hg and tibialis anterior IMP of 28 +/- 1 mm Hg compared to 17 +/- 1 mm Hg and 20 +/- 2 mm Hg, respectively, generated by inelastic leggings and 8 +/- 1 mm Hg and 11 +/- 1 mm Hg, respectively, without leggings. During sitting, walking, and running, however, peak IMPs generated in the muscular compartments by elastic and inelastic leggings were similar. Our results suggest that elastic leg compression applied over a long period in the recumbent posture may impede microcirculation and jeopardize tissue viability.(ABSTRACT TRUNCATED AT 250 WORDS).

Clinical Trial↗

Decreased heterotopic osteogenesis in vitamin-D-deficient, but normocalcemic guinea pigs

The effect of vitamin D deficiency unhampered by hypocalcemia on de novo bone formation was studied in guinea pigs. Heterotopic induction of osteogenesis was evaluated 4 weeks after intramuscular transplantation of allogenic urinary bladder transitional epithelium from vitamin-D-repleted (+D) donors into +D and -D recipients. In -D recipients the frequency of osteogenesis and the amount of induced bone were significantly diminished; induced bone was less mature, scantly cellular woven bone poorly repopulated with bone marrow. No effect of vitamin D deficiency on orthotopic bone growth and on mineralization of orthotopic and heterotopically induced bone was observed. It is proposed that in addition to inducing factors (BMPs, growth factors) which may be responsible for transformation of mesenchymal cells to osteoprogenitor cells, normal concentrations of 1,25-(OH)2D3 may be required for proliferation and further differentiation of these cells into osteoblasts and for expression of genes engaged in extracellular matrix formation and maturation.

NASA Discipline Musculoskeletal↗

Test and Analysis of a Hyper-X Carbon-Carbon Leading Edge Chine

During parts production for the X43A Mach 10 hypersonic vehicle nondestructive evaluation (NDE) of a leading edge chine detected on imbedded delamination near the lower surface of the part. An ultimate proof test was conducted to verify the ultimate strength of this leading edge chine part. The ultimate proof test setup used a pressure bladder design to impose a uniform distributed pressure field over the bi-planar surface of the chine test article. A detailed description of the chine test article and experimental test setup is presented. Analysis results from a linear status model of the test article are also presented and discussed. Post-test inspection of the specimen revealed no visible failures or areas of delamination.

Smith, Russell W.↗

Inflatable Structures: Test Results and Development Progress Since TransHab

JSC's TransHab project was the first successful development program to prove the viability of inflatable habitats for space applications. Although TransHab was cancelled in 2000, significant progress has been made this past year by JSC engineers. Since February 2005, the following test articles have been manufactured and tested: 1 - An 88-in diameter restraint layer was pressure-tested to failure and reached an ultimate pressure of 197psi. This test article demonstrated the ability to build a 35- foot diameter inflatable with a factor of safety of 4.0 at 10.2 psi. 2 - An 88-in diameter restraint layer with a window frame incorporated into the restraint layer was tested to failure and reached an ultimate pressure of 197 psi. This test article demonstrated the ability to incorporate windows and other structural penetrations in the woven restraint layer without reducing its strength. 3 - An 88-inch diameter folding demonstrator that includes a bladder, restraint layer, and all of the MMOD shell layers was manufactured and assembled. This test article demonstrated an improved and simplified shell assembly and folding technique which installs pre-folded shell sections in a controlled manner. 4 - Fifth-scale MMOD hypervelocity test articles have demonstrated fiberglass as a viable material for a MMOD bumper shield which is cheaper and more readily available than previously used materials. In addition, four different full-scale advanced shape inflatable mockups have been manufactured and evaluated for applications such as lunar habitats, airlocks, and transfer tunnels.

Johnson, Chris↗

Studying Host-Pathogen Interactions In 3-D: Organotypic Models For Infectious Disease And Drug Development

Representative, reproducible and high-throughput models of human cells and tissues are critical for a meaningful evaluation of host-pathogen interactions and are an essential component of the research developmental pipeline. The most informative infection models - animals, organ explants and human trials - are not suited for extensive evaluation of pathogenesis mechanisms and screening of candidate drugs. At the other extreme, more cost effective and accessible infection models such as conventional cell culture and static co-culture may not capture physiological and three-dimensional aspects of tissue biology that are important in assessing pathogenesis, and effectiveness and cytotoxicity of therapeutics. Our lab has used innovative bioengineering technology to establish biologically meaningful 3-D models of human tissues that recapitulate many aspects of the differentiated structure and function of the parental tissue in vivo, and we have applied these models to study infectious disease. We have established a variety of different 3-D models that are currently being used in infection studies - including small intestine, colon, lung, placenta, bladder, periodontal ligament, and neuronal models. Published work from our lab has shown that our 3-D models respond to infection with bacterial and viral pathogens in ways that reflect the infection process in vivo. By virtue of their physiological relevance, 3-D cell cultures may also hold significant potential as models to provide insight into the neuropathogenesis of HIV infection. Furthermore, the experimental flexibility, reproducibility, cost-efficiency, and high throughput platform afforded by these 3-D models may have important implications for the design and development of drugs with which to effectively treat neurological complications of HIV infection.

Nickerson, Cheryl A.↗

Robots in Space -Psychological Aspects

A viewgraph presentation on the psychological aspects of developing robots to perform routine operations associated with monitoring, inspection, maintenance and repair in space is shown. The topics include: 1) Purpose; 2) Vision; 3) Current Robots in Space; 4) Ground Based Robots; 5) AERCam; 6) Rotating Bladder Robot (ROBLR); 7) DART; 8) Robonaut; 9) Full Immersion Telepresence Testbed; 10) ERA; and 11) Psychological Aspects

Sipes, Walter E.↗

Oil Saving Seal

Driven under difficult field conditions, the Army Jeep shown went more than 22,000 miles without an oil change in a test conducted by the U.S. Army Mobility Equipment Research and Development Command. Key to this exceptionally long oil life was a set of piston ring seals made of a new synthetic rubber formula called RC-34; the seal pictured, photographed after its arduous Army trial, shows no signs of deterioration. The seal and the RC-34 material, which may soon be available for use in the family auto, were developed by Ramsey Corporation, St. Louis, Missouri, a division of TRW Automotive Worldwide. The oil in an automobile engine must be I replaced every few thousand miles not because it wears out but because it becomes contaminated. The contamination sources are gasoline and combustion gases which blow by the piston rings to mix with the oil, reducing the oil's ability to lubricate properly. Seeking to prolong oil life by eliminating "blowby," Ramsey Corporation looked for a better way to seal piston rings and used NASA technology as a departure point. The parent company TRW, under contract to NASA's Jet Propulsion Laboratory, had developed seals and bladders from a type of material called elastomers which where designed to withstand the environmental extremes of interplanetary flight. That effort formed a knowledge base for research which culminated in Ramsey's RC-34 elastomer.

Source record↗

Extravehicular Mobility Unit Penetration Probability from Micrometeoroids and Orbital Debris: Revised Analytical Model and Potential Space Suit Improvements

The NASA Extravehicular Mobility Unit (EMU) micrometeoroid and orbital debris protection ability has recently been assessed against an updated, higher threat space environment model. The new environment was analyzed in conjunction with a revised EMU solid model using a NASA computer code. Results showed that the EMU exceeds the required mathematical Probability of having No Penetrations (PNP) of any suit pressure bladder over the remaining life of the program (2,700 projected hours of 2 person spacewalks). The success probability was calculated to be 0.94, versus a requirement of >0.91, for the current spacesuit s outer protective garment. In parallel to the probability assessment, potential improvements to the current spacesuit s outer protective garment were built and impact tested. A NASA light gas gun was used to launch projectiles at test items, at speeds of approximately 7 km per second. Test results showed that substantial garment improvements could be made, with mild material enhancements and moderate assembly development. The spacesuit s PNP would improve marginally with the tested enhancements, if they were available for immediate incorporation. This paper discusses the results of the model assessment process and test program. These findings add confidence to the continued use of the existing NASA EMU during International Space Station (ISS) assembly and Shuttle Operations. They provide a viable avenue for improved hypervelocity impact protection for the EMU, or for future space suits.

Chase, Thomas D.↗