Search NASA⌕ Search

SEARCH · Search NASA

Results for “Basic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

A compact and portable gamma-ray spectrometer (GRASP) for inertial confinement fusion and basic science experiments

A compact and portable gamma-ray spectrometer has been designed to diagnose different components of the inertial confinement fusion-relevant γ-ray spectrum with energies between ∼3.7–17.9 MeV. The system is designed to be as compact as possible for convenient transportation and fielding in diagnostic ports on the OMEGA laser, the National Ignition Facility, and other photon-source facilities. The system consists of a conversion foil for Compton scattering in front of four magnetic spectrometer “arms,” each covering a different energy range and constructed out of cylindrical permanent magnet Halbach arrays. Monte Carlo simulations have been used to optimize and assess the performance of the conversion foil, and COSY INFINITY ion-optical simulations have been used to optimize the spectrometer magnets. The performance of the design is assessed for a simulated direct-drive γ-ray spectrum. Spanning its total γ-ray energy bandwidth and using a 1.7 mm thick boron conversion foil, the system’s total energy resolution and efficiency are ∼15.8%–4.5% and 5.4 × 10−7–3.7 × 10−7e−/γ, respectively, with room for improvement. Spectral γ-ray measurements will provide guidance to the inertial confinement fusion program toward achieving high-energy gain relevant to inertial fusion energy and enable new measurement capabilities for basic discovery science.

Instruments & Instrumentation↗

Technique for measuring basic characteristics of electron-optical cameras

A procedure is described for determining the basic parameters of linear-sweep electron-optical cameras. The techniques are considered for measuring the limiting temporal resolution and dynamic range of the PS-1/S1 camera using a femtosecond laser and sinusoidal-modulated laser radiation. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

PITCH-ANGLE SCATTERING: RESONANCE VERSUS NONRESONANCE, A BASIC TEST OF THE QUASILINEAR DIFFUSIVE RESULT

Due to the very broad range of the scales available for the development of turbulence in space and astrophysical plasmas, the energy at the resonant scales of wave-particle interaction often constitutes only a tiny fraction of the total magnetic turbulent energy. Despite the high efficiency of resonant wave-particle interaction, one may therefore question whether resonant interaction really is the determining interaction process between particles and turbulent fields. By evaluating and comparing resonant and nonresonant effects in the frame of a quasilinear calculation, the dominance of resonance is here put to the test. By doing so, a basic test of the classical resonant quasilinear diffusive result for the pitch-angle scattering of charged energetic particles is also performed.

79 ASTRONOMY AND ASTROPHYSICS↗

Cold and warm atomic gas around the Perseus molecular cloud. I. Basic properties

Using the Arecibo Observatory, we have obtained neutral hydrogen (HI) absorption and emission spectral pairs in the direction of 26 background radio continuum sources in the vicinity of the Perseus molecular cloud. Strong absorption lines were detected in all cases, allowing us to estimate spin temperature (T{sub s} ) and optical depth for 107 individual Gaussian components along these lines of sight. Basic properties of individual H I clouds (spin temperature, optical depth, and the column density of the cold and warm neutral medium (CNM and WNM), respectively) in and around Perseus are very similar to those found for random interstellar lines of sight sampled by the Millennium H I survey. This suggests that the neutral gas found in and around molecular clouds is not atypical. However, lines of sight in the vicinity of Perseus have, on average, a higher total H I column density and the CNM fraction, suggesting an enhanced amount of cold H I relative to an average interstellar field. Our estimated optical depth and spin temperature are in stark contrast with the recent attempt at using Planck data to estimate properties of the optically thick H I. Only ∼15% of lines of sight in our study have a column density weighted average spin temperature lower than 50 K, in comparison with ≳ 85% of Planck's sky coverage. The observed CNM fraction is inversely proportional to the optical depth weighted average spin temperature, in excellent agreement with the recent numerical simulations by Kim et al. While the CNM fraction is, on average, higher around Perseus relative to a random interstellar field, it is generally low, between 10%-50%. This suggests that extended WNM envelopes around molecular clouds and/or significant mixing of CNM and WNM throughout molecular clouds are present and should be considered in the models of molecule and star formation. Our detailed comparison of H I absorption with CO emission spectra shows that only 3 of the 26 directions are clear candidates for probing the CO-dark gas as they have N(H I)>10{sup 21} cm{sup –2} yet no detectable CO emission.

79 ASTRONOMY AND ASTROPHYSICS↗

A SPITZER SURVEY OF YOUNG STELLAR CLUSTERS WITHIN ONE KILOPARSEC OF THE SUN: CLUSTER CORE EXTRACTION AND BASIC STRUCTURAL ANALYSIS

We present a uniform mid-infrared imaging and photometric survey of 36 young, nearby, star-forming clusters and groups using Spitzer IRAC and MIPS. We have confidently identified and classified 2548 young stellar objects (YSOs) using recently established mid-infrared color-based methods. We have devised and applied a new algorithm for the isolation of local surface density enhancements from point source distributions, enabling us to extract the overdense cores of the observed star-forming regions for further analysis. We have compiled several basic structural measurements of these cluster cores from the data, such as mean surface densities of sources, cluster core radii, and aspect ratios, in order to characterize the ranges for these quantities. We find that a typical cluster core is 0.39 pc in radius, has 26 members with infrared excess in a ratio of Class II to Class I sources of 3.7, is embedded in a A{sub K} = 0.8 mag cloud clump, and has a surface density of 60 pc{sup -2}. We examine the nearest neighbor distances among the YSOs in several ways, demonstrating similarity in the spacings between Class II and Class I sources but large member clusters appear more dense than smaller clusters. We demonstrate that near-uniform source spacings in cluster cores are common, suggesting that simple Jeans fragmentation of parsec-scale cloud clumps may be the dominant process governing star formation in nearby clusters and groups. Finally, we compare our results to other similar surveys in the literature and discuss potential biases in the data to guide further interpretation.

79 ASTRONOMY AND ASTROPHYSICS↗

Targeted seed EMS mutagenesis reveals a basic helix–loop–helix transcription factor underlying male sterility in sorghum

Abstract Forward genetic screens of mutant populations are fundamental for functional genomics studies. However, isolating independent mutant alleles to molecularly identify causal genes is challenging in species recalcitrant to genetic manipulation. Here, we demonstrate that classic seed ethyl methanesulfonate (EMS) mutagenesis coupled with genome sequencing can overcome this limitation in sorghum. We used this method to generate new mutant alleles of sorghum MALE STERILE 8 (MS8) and identified the causal locus for the ms8 phenotype as Sobic.004G270900, which encodes the sorghum ortholog of maize bhlh122, a basic helix–loop–helix (bHLH) transcription factor required for male fertility in maize. Bulked segregant analysis mapped ms8-1 to a region on chromosome 4 containing Sobic.004G270900. Seeds from heterozygous MS8/ms8-1 plants were mutagenized and screened for chimeric inflorescences containing sectors with white, sterile anthers resembling the ms8-1 homozygous phenotype. DNA sequencing of sterile and fertile sectors from a single chimeric inflorescence revealed two mutations in Sobic.004G270900 within the sterile sector, but not the fertile sector. Isolation of this loss-of-function allele (ms8-2) established Sobic.004G270900 as the causative locus for male sterility in the ms8 mutant. We generated additional alleles of MS8 in a different genetic background using CRISPR/Cas9-based gene editing, where deletions in Sobic.004G270900 also resulted in male sterility. Our work identified a gene underlying male sterility in sorghum and provides a novel and straightforward genetic tool for researchers who lack access to advanced transformation facilities to validate gene candidates. Unlike gene editing, no prior knowledge of candidate genes is required for targeted seed EMS mutagenesis to aid identification of causal loci.

Genetics & Heredity↗

Abashian-Booth-Crowe Effect in Basic Double-Pionic Fusion: A New Resonance?

We report on an exclusive and kinematically complete high-statistics measurement of the basic double-pionic fusion reaction pn{yields}d{pi}{sup 0}{pi}{sup 0} over the full energy region of the ABC effect, a pronounced low-mass enhancement in the {pi}{pi}-invariant mass spectrum. The measurements, which cover also the transition region to the conventional t-channel {Delta}{Delta} process, were performed with the upgraded WASA detector setup at COSY. The data reveal the Abashian-Booth-Crowe effect to be uniquely correlated with a Lorentzian energy dependence in the integral cross section. The observables are consistent with a narrow resonance with m=2.37 GeV, {Gamma}{approx_equal}70 MeV and I(J{sup P})=0(3{sup +}) in both pn and {Delta}{Delta} systems. Necessary further tests of the resonance interpretation are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dose distribution of a 125 keV mean energy microplanar x-ray beam for basic studies on microbeam radiotherapy

A multislit collimator was designed and fabricated for basic studies on microbeam radiation therapy (MRT) with an x-ray energy of about 100 keV. It consists of 30 slits that are 25 {mu}m high, 30 mm wide, and 5 mm thick in the beam direction. The slits were made of 25 {mu}m-thick polyimide sheets that were separated by 175 {mu}m-thick tungsten sheets. The authors measured the dose distribution of a single microbeam with a mean energy of 125 keV by a scanning slit method using a phosphor coupled to a charge coupled device camera and found that the ratios of the dose at the center of a microbeam to that at midpositions to adjacent slits were 1050 and 760 for each side of the microbeam. This dose distribution was well reproduced by the Monte Carlo simulation code PHITS.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-A-18C-01: Proton Therapy I: Basics of Proton Therapy

The goal of this session is to introduce the audience to the physics, dosimetry and treatment planning procedures used in proton therapy. The course material covers the basic physics of proton interaction with matter and physical characteristics of clinical proton beams. It will provide information on proton delivery systems and beam delivery techniques for scattered and scanning proton beams. It will include the requirements for dosimetry measurements and present the equipment needed for commissioning of proton beams for clinical use and quality assurance checks as well as methods used for proton beam calibration and dose verification of patient treatment fields. The session covers the treatment planning strategies for various anatomical sites, methods to address uncertainties in proton therapy and uncertainty mitigation to generate robust treatment plans. Challenges involved in the motion management in proton therapy will also be discussed. Learning Objectives: Gain knowledge on physics, dosimetry, treatment planning and quality assurance for proton therapy. Understand the uncertainties associated with proton therapy and currently used strategies for their mitigation in treatment planning.

07 ISOTOPE AND RADIATION SOURCES↗

TU-EF-BRA-00: MR Basics I

NMR, and Proton Density MRI of the 1D Patient - Anthony Wolbarst Net Voxel Magnetization, m(x,t). T1-MRI; The MRI Device - Lisa Lemen ‘Classical’ NMR; FID Imaging in 1D via k-Space - Nathan Yanasak Spin-Echo; S-E/Spin Warp in a 2D Slice - Ronald Price Magnetic resonance imaging not only reveals the structural, anatomic details of the body, as does CT, but also it can provide information on the physiological status and pathologies of its tissues, like nuclear medicine. It can display high-quality slice and 3D images of organs and vessels viewed from any perspective, with resolution better than 1 mm. MRI is perhaps most extraordinary and notable for the plethora of ways in which it can create unique forms of image contrast, reflective of fundamentally different biophysical phenomena. As with ultrasound, there is no risk from ionizing radiation to the patient or staff, since no X-rays or radioactive nuclei are involved. Instead, MRI harnesses magnetic fields and radio waves to probe the stable nuclei of the ordinary hydrogen atoms (isolated protons) occurring in water and lipid molecules within and around cells. MRI consists, in essence, of creating spatial maps of the electromagnetic environments around these hydrogen nuclei. Spatial variations in the proton milieus can be related to clinical differences in the biochemical and physiological properties and conditions of the associated tissues. Imaging of proton density (PD), and of the tissue proton spin relaxation times known as T1 and T2, all can reveal important clinical information, but they do so with approaches so dissimilar from one another that each is chosen for only certain clinical situations. T1 and T2 in a voxel are determined by different aspects of the rotations and other motions of the water and lipid molecules involved, as constrained by the local biophysical surroundings within and between its cells – and they, in turn, depend on the type of tissue and its state of health. Three other common applications of MRI exploit its capability to detect and image distinct movements of fluids: MR angiography (MRA), which rivals CT angiography but often requires no contrast medium, monitors the bulk flow of blood; functional MRI (f MRI), distinguishes the perfusion of oxygenated blood from that of de-oxygenated, and lights up parts of the brain that are activated by a stimulus, rather like PET; and diffusion tensor imaging (DTI) indicates the diffusion of free water along tracts of axons, thereby bringing nerve trunks into view. There are variants on all of these themes, and on others as well. Magnetic Resonance Spectroscopy (MRS), for example, can perform non-invasive ‘virtual biopsies’ that allow identification of certain cancers and other lesions. And an MRI-guided needle biopsy can sample brain tissue from a region only millimeters in dimensions. MRI, however, involves deeper and more complex aspects of physics, technology, and biology than do most other imaging modalities, and it is widely considered to be correspondingly more difficult to learn. We could probably cover all of this rather comprehensively if we had 50 hours available rather than 2 ̶ but, to paraphrase a former Secretary of Defense, you tell your story in the time you have allotted. The four presenters and another physicist, Kevin King from GE, have combined their efforts to co-author a single slide show that describes essentials of MRI as simply as possible. It is obviously far from thorough, but hopefully it will succeed in explaining some of the basics in a simplified but still valid fashion; in providing a taste of the numerous capabilities and complexities of the modality; and in whetting your appetite to learn more. Part I. NMR, and Proton Density MRI of the 1D Patient (Wolbarst), begins with an introductory case study that illustrates a half dozen ways in which MRI provides valuable clinical information. It then explores the nuclear magnetic resonance (NMR) phenomenon, which underlies MRI. NMR can be introduced with either of two approaches. In the first, one thinks (loosely) of the nuclei of hydrogen atoms as (rotating and charged and therefore) magnetic objects, whose spin-axes tend to align in a strong external magnetic field, much like a compass needle. As with the Bohr atom, this spin-up/spin-down picture is a highly abridged version of the full quantum mechanical treatment, but still it leads to some useful, legitimate pictures of the NMR process occurring within a voxel: When RF photons of the correct (Larmor) frequency elevate protons in a fixed magnetic field out of their lower-energy spin state into the upper, the NMR phenomenon is indicated by the detectable absorption of RF power. With the addition of a linear gradient field along a multi-voxel, one-dimensional patient/phantom, as well, we can determine the water content of each compartment – an example of a real MRI study, albeit in 1D. Part I concludes with a discussion of the net magnetization at position x, m0(x), under conditions of dynamic thermal equilibrium, which leads into: Part II. Net Voxel Magnetization, m(x,t); T1-MRI; The MRI Device (Lemen), investigates the biophysics of the form of proton spin relaxation process characterized by the time T1. It then moves on to the creation of an MR image that displays the spatial variation in the values of this clinically relevant parameter, again in 1D. Finally, the design and workings of a clinical MRI machine are sketched, in preparation for: Part III. ‘Classical’ NMR; FID Imaging in 1D via k-Space (Yanasak) presents the second standard approach to NMR and MRI, the classical model. It focuses on the time dependence of the net nuclear magnetization, m(x,t), the overall magnetic field generated by the cohort of protons in the voxel at position x. Quite remarkably, this nuclear net magnetization itself acts in a strong magnetic field like a gyroscope in a gravitational field. This tack is better for explaining Free Induction Decay (FID), which involves a brief introduction to the Fourier transform and k-space. This leads to conventional Spin-Echo (S-E) reconstruction techniques for creating clinical images from raw data, and sets the stage for: Part IV. Spin-Echo; S-E / Spin Warp in a 2D Slice (Price) discusses application of the S- E sequence of radiofrequency pulses and gradient magnetic fields to the 1D patient. T2 is introduced but not explained. This Part also considers how to manipulate the image acquisition parameters so as to generate clinical pictures with contrast dominated by spatial variations in PD, T1, or T2. We conclude by demonstrating the spin-warp approach to imaging in 2D with a simple 2×2, 4-voxel example. Much of this material is presented in more detail in the chapter “MRI of the One-dimensional Patient, Part I”, in Advances in Medical Physics, Vol 5 (2014). Copies are on display at the Medical Physics Publishing booth. Learning Objectives: The participant will learn about the processes of NMR and T1 spin relaxation in a tissue voxel in a uniform magnetic field. The participant will learn about combining spin-up/spin-down NMR and T1 processes with a linear gradient to effect frequency-encoding of voxel spatial position. This approach can be used to create proton density and T1 MRI maps, respectively, of the contents of multi-voxel 1D phantoms. The participant will learn about how the ‘classical’ model of NMR it can generate Free Induction Decay (FID) images of 1D phantoms, which involves the use of the Fourier transform in k-space. This can lead simply into standard Spin-Echo images. The participant will learn about extending Spin-Echo imaging into 2 and more dimensions.

60 APPLIED LIFE SCIENCES↗

WE-A-BRD-00: MR Basics II

Ever since its introduction as a diagnostic imaging modality over 30 years ago, the radiation therapy community has acknowledged the utility of MR imaging as a tool for not only improved visualization of the target volume but also for demarcation of adjacent organs at risk. However, the adaptation of MR imaging in radiation oncology has, until recently been slow due in large part to the inability to image radiation therapy patients in their treatment position. With the introduction of so-called wide bore high field MR scanners, multi element flexible receive only RF coils, high performance imaging gradients and a range of volumetric imaging sequences it is now possible to obtain both high resolution and high signal-to-noise ratio images of in-treatment radiation therapy patients within clinically feasible imaging times. As a Result, there is renewed interest in the use of MR imaging for radiation oncology treatment planning that is being translated into physical siting and integration of these systems into radiation oncology departments. As MR imaging expands into the radiation oncology domain there is a significant and unmet need for radiation therapy physicists to become educated regarding the strengths, limitations and technical challenges associated with MR imaging. The purpose of this presentation is to address this need by providing an educational overview of the techniques and challenges associated with MR imaging of patients for radiation therapy treatment planning. As such this presentation will: 1) describe the fundamental differences between imaging of patients for diagnostic and therapeutic purposes (i.e. radiation therapy planning), 2) describe most commonly used imaging sequences and contrasts for identification of disease for radiation planning, 3) identify the most common sources of image distortion and techniques to reduce their effect on spatial fidelity of the MR data, 4) describe the effects of motion and methods to quantify/correct it, and 5) identify emergent techniques for performing MR only treatment simulation. Upon completion attendees will have a working understanding of the basic methodologies associated with MR imaging in radiation oncology, the unique technical challenges imposed by MR imaging in the treatment position and techniques to address these. Learning Objectives: 1. Understand the differences between MR imaging for diagnostic imaging and for radiation therapy planning. 2. Identify the most common sources of distortion and artifacts and simple methods to correct them. 3. Understand the challenges with MR imaging in the therapy treatment position and appropriate techniques to address them.

60 APPLIED LIFE SCIENCES↗

TH-A-207B-01: Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity

Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.

60 APPLIED LIFE SCIENCES↗

Highly Basic Clusters in the Herpes Simplex Virus 1 Nuclear Egress Complex Drive Membrane Budding by Inducing Lipid Ordering

During replication of herpesviruses, capsids escape from the nucleus into the cytoplasm by budding at the inner nuclear membrane. This unusual process is mediated by the viral nuclear egress complex (NEC) that deforms the membrane around the capsid by oligomerizing into a hexagonal, membrane-bound scaffold. Here, we found that highly basic membrane-proximal regions (MPRs) of the NEC alter lipid order by inserting into the lipid headgroups and promote negative Gaussian curvature. We also find that the electrostatic interactions between the MPRs and the membranes are essential for membrane deformation. One of the MPRs is phosphorylated by a viral kinase during infection, and the corresponding phosphomimicking mutations block capsid nuclear egress. We show that the same phosphomimicking mutations disrupt the NEC-membrane interactions and inhibit NEC-mediated budding in vitro, providing a biophysical explanation for the in vivo phenomenon. Our data suggest that the NEC generates negative membrane curvature by both lipid ordering and protein scaffolding and that phosphorylation acts as an off switch that inhibits the membrane-budding activity of the NEC to prevent capsid-less budding.

membrane curvature↗

One-dimensional SnF{sub 2} single crystals in the inner channels of single-wall carbon nanotubes: I. Preparation and basic characterization

One-dimensional (1D) SnF{sub 2} single crystals have been obtained by crystallization from melt in the inner channels of single-wall carbon nanotubes (SWCNTs). SWCNTs with an inner diameter of 1.02-1.4 nm, synthesized by electric-arc discharge and chemically purified, were used for incorporation. The synthesized 1D SnF{sub 2} single crystal-SWCNT composites are basically characterized by X-ray diffraction, energy-dispersive analysis, electron microscopy, and chemical analysis. The characteristic motifs of tin cation distribution in the SWCNT inner channel confirm the formation of SnF{sub 2} single crystals.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Basic analysis of reflectometry data software package for the analysis of multilayered structures according to reflectometry data

The main principles of developing the Basic Analysis of Reflectometry Data (BARD) software package, which is aimed at obtaining a unified (standardized) tool for analyzing the structure of thin multilayer films and nanostructures of different nature based on reflectometry data, are considered. This software package contains both traditionally used procedures for processing reflectometry data and the authors' original developments on the basis of new methods for carrying out and analyzing reflectometry experiments. The structure of the package, its functional possibilities, examples of application, and prospects of development are reviewed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Basic properties of the Einstein equations with a Ricci-Scalar-Dependent cosmological term

Basic properties of the Einstein equations modified by a cosmological {lambda}-term dependent on the Ricci scalar R are considered. We show that in addition to a nonzero divergence of the energy-momentum tensor of the matter and the consequent cold matter mass nonconservation as the Universe expands, this model suggests a significant modification of the equations for the gravitational potential and particle acceleration in the Newtonian approximation. These circumstances allow the necessary criteria for possible functional dependences {lambda}(R) to be formulated. Nevertheless, by introducing a variable {lambda}-term, we can look at the problems of dark matter and dark energy anew. In particular, we show that the model in which the cosmological term depends linearly on the Ricci scalar (this corresponds to the approximation of a more complex dependence in the case of low matter densities) makes it possible to satisfactorily describe the rotation curves of galaxies without invoking the dark matter hypothesis and to construct a cosmological model with a variable vacuum energy density, in qualitative agreement with the present views of the early Universe.

97 MATHEMATICS AND COMPUTING↗

On the vulnerability of basic quantum key distribution protocols and three protocols stable to attack with 'blinding' of avalanche photodetectors

The fundamental quantum mechanics prohibitions on the measurability of quantum states allow secure key distribution between spatially remote users to be performed. Experimental and commercial implementations of quantum cryptography systems, however, use components that exist at the current technology level, in particular, one-photon avalanche photodetectors. These detectors are subject to the blinding effect. It was shown that all the known basic quantum key distribution protocols and systems based on them are vulnerable to attacks with blinding of photodetectors. In such attacks, an eavesdropper knows all the key transferred, does not produce errors at the reception side, and remains undetected. Three protocols of quantum key distribution stable toward such attacks are suggested. The security of keys and detection of eavesdropping attempts are guaranteed by the internal structure of protocols themselves rather than additional technical improvements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Statistical derivation of basic equations of diffusional kinetics in alloys with application to the description of diffusion of carbon in austenite

Basic equations of diffusional kinetics in alloys are statistically derived using the master equation approach. To describe diffusional transformations in substitution alloys, we derive the 'quasi-equilibrium' kinetic equation that generalizes its earlier versions by taking possible 'interaction renormalization' effects into account. For the interstitial alloys Me-X, we derive an explicit expression for the diffusivity D of an interstitial atom X. This expression notably differs from those used in previous phenomenological treatments. This microscopic expression for D is applied to describe the diffusion of carbon in austenite based on some simple models of carbon-carbon interaction. The results obtained enable us to make certain conclusions about the real form of these interactions and about the scale of the 'transition state entropy' for diffusion of carbon in austenite.

36 MATERIALS SCIENCE↗