The Walk on Floor Eyes Closed Tandem Step Test as a Quantitative Measure of Ataxia After Space Flight

INTRODUCTION Posture and locomotion are among the functions most affected by space flight. Postflight ataxia can be quantified easily by using the walk on the floor line test with the eyes closed (WOFEC). Data from a modified WOFEC were obtained as part of an ongoing interdisciplinary pre- and postflight study (Functional Task Test, FTT) designed to evaluate both postflight functional performance of astronauts and related physiological changes. METHODS Five astronauts with flight durations of 12 to 16 days participated in this study. Performance measurements were obtained in 2 preflight sessions, on landing day, and 1, 6, and 30 days after landing. The WOFEC test consisted of walking with the feet placed heel to toe in tandem, arms folded across the chest and eyes closed, for 10 steps. A trial was initiated after the eyes were closed and the front foot was aligned with the rear foot. The performance metric was the average percentage of correct steps completed over 3 trials. A step was not counted as correct if the crewmember sidestepped, opened eyes, or paused for more than 3 seconds between steps. Step accuracy was scored independently by 3 examiners. RESULTS Immediately after landing subjects seemed to be unaware of their foot position relative to their body or the floor. The percentage of correct steps was significantly decreased on landing day. Partial recovery was observed the next day, and full recovery to baseline on the sixth day post landing. CONCLUSION These data clearly demonstrate the sensorimotor challenges facing crewmembers after they return from space flight. Although this simple test is intended to complement the FTT battery of tests, it has some stand-alone value as it provides investigators with a means to quantify vestibular ataxia as well as provide instant feedback on postural stability without the use of complex test equipment.

Fisher, E. A.↗

NiCd battery failure analysis

The failure of a nickel cadmium battery undergoing tests is discussed. Reasons for the complete destruction of the battery while undergoing preparation for thermal vacuum testing are given.

Sense, K. A.↗

Structure–Property Relationships of Recycled Lithium-Ion Battery Cathodes: Microstructure Optimization Using Virtual Materials Testing

The increasing demand for sustainable battery technologies requires effective recycling strategies for end-of-life lithium-ion battery cathodes. In this study, virtual materials testing, a well-established framework for modeling conventionally manufactured NMC-based cathodes, is applied to partially recycled cathodes. To this end, virtual cathodes consisting of mixtures of pristine and recycled NMC particles are utilized to systematically analyze structure–property relationships depending on mixing ratios and different spatial arrangement strategies. For this purpose, a stochastic 3D model is developed that is capable of generating virtual cathodes with arbitrary volume fractions of active materials and mixing ratios of pristine and recycled NMC particles. Particularly, the stochastic 3D model can mimic the different size distributions of pristine and recycled particles that are observed in image data. Additionally, the model allows the structuring of pristine and recycled NMC either uniformly mixed or layer-wise arranged, mimicking single- and dual-layer cathodes. Subsequently, a systematic computational analysis is conducted to assess the influence of increasing active material ratios of recycled particles, ranging from 0 % to 100 %, while maintaining a constant overall active material volume fraction. The impact of particle mixing on cathode performance is evaluated by examining transport-relevant geometrical descriptors and effective properties, such as geodesic tortuosity, specific surface area, and tortuosity factor.

25 ENERGY STORAGE↗

Parametric and cycle tests of a 40-A-hr bipolar nickel-hydrogen battery

A series of tests was performed to characterize battery performance relating to certain operating parameters which included charge current, discharge current, temperature and pressure. The parameters were varied to confirm battery design concepts and to determine optimal operating conditions. Spacecraft power requirements are constantly increasing. Special spacecraft such as the Space Station and platforms will require energy storage systems of 130 and 25 kWh, respectively. The complexity of these high power systems will demand high reliability, and reduced mass and volume. A system that uses batteries for storage will require a cell count in excess of 400 units. These cell units must then be assembled into several batteries with over 100 cells in a series connected string. In an attempt to simplify the construction of conventional cells and batteries, the NASA Lewis Research Center battery systems group initiated work on a nickel-hydrogen battery in a bipolar configuration in early 1981. Features of the battery with this bipolar construction show promise in improving both volumetric and gravimetric energy densities as well as thermal management. Bipolar construction allows cooling in closer proximity to the cell components, thus heat removal can be accomplished at a higher rejection temperature than conventional cell designs. Also, higher current densities are achievable because of low cell impedance. Lower cell impedance is achieved via current flow perpendicular to the electrode face, thus reducing voltage drops in the electrode grid and electrode terminals tabs.

Cataldo, R. L.↗

High-Mileage Courier Fleet Vehicle On-Road Logger Data

This dataset describes the performance and fuel efficiency of AVTA test vehicles operating in commercial courier fleets the Phoenix, AZ metro area between 2010 and 2016. Aftermarket data loggers were installed in two to four vehicles of each of 30+ distinct year/make/models (see reference ["INL Advanced Vehicle Testing Activity: On-road Logger and Laboratory Battery Pack Testing Vehicle List"](https://avt.inl.gov/sites/default/files/pdf/reports/DatasetVehicleList.pdf) for full list of vehicles). Loggers recorded vehicle operation as they were driven up to 160,000 miles in up to three years of fleet testing. Parameters were logged at 1-second intervals, including - vehicle speed, - engine and/or electric motor speed, - fuel and/or electricity consumption, and - ambient temperature. This dataset includes both raw second-by-second data and trip-level metrics. This dataset is shared by API; a small sample of the vehicle and logger data has been extracted and is also available for download.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stability, reliability and cross-mode correlations of tests in a recommended 8-minute performance assessment battery

A need exists for an automated performance test system to study drugs, agents, treatments, and stresses of interest to the aviation, space, and environmental medical community. The purpose of this present study is to evaluate tests for inclusion in the NASA-sponsored Automated Performance Test System (APTS). Twenty-one subjects were tested over 10 replications with tests previously identified as good candidates for repeated-measure research. The tests were concurrently administered in paper-and-pencil and microcomputer modes. Performance scores for the two modes were compared. Data from trials 1 to 10 were examined for indications of test stability and reliability. Nine of the ten APT system tests achieved stability. Reliabilities were generally high. Cross-correlation of microbased tests with traditional paper-and-pencil versions revealed similarity of content within tests in the different modes, and implied at least three cognition and two motor factors. This protable, inexpensive, rugged, computerized battery of tests is recommended for use in repeated-measures studies of environmental and drug effects on performance. Identification of other tests compatible with microcomputer testing and potentially capable of tapping previously unidentified factors is recommended. Documentation of APTS sensitivity to environmental agents is available for more than a dozen facilities and is reported briefly. Continuation of such validation remains critical in establishing the efficacy of APTS tests.

Wilkes, R. L.↗

Non-gassing nickel-cadmium battery electrodes and cells: Testing of 25 Ah cells

The testing of 30 practical size, experimental 25 ampere hour cells constructed as part of an earlier negative limited cell development program is discussed. The test results showed that the negative limited cell is a possible means of developing a long-lived secondary cell. The cells were tested for 500 cycles using an accelerated regime approximating a 90-minute orbit period. Three groups of ten cells were tested at 0,25, and 40 C. The cycle data showed that the negative limited cells had higher degradation rates at the higher operating temperatures. At the conclusion of 500 cycles, the three groups had average capacities of 16.83, 12.74, and 5.71 ampere hours for testing at 0, 25, 40 C, respectively. The conditioning capacities of these cells was in the 25 ampere hours range. The internal cell pressures of the three groups was also temperature dependent and was, in general, in the 2 psig range during the course of the test program. No periodic variation of the internal pressure with the state-of-charge was observed except with some cells tested at 40 C.

Luksha, E.↗

Nickel hydrogen battery cell storage matrix test

Test were conducted to evaluate post storage performance of nickel hydrogen cells with various design variables, the most significant being nickel precharge versus hydrogen precharge. Test procedures and results are presented in outline and graphic form.

Wheeler, James R.↗

1970 NASA/GSFC Battery Workshop

NASA/GSFC workshop on materials processing, chemical analysis, cell processing, and testing of batteries for aerospace applications

Source record↗

Space Technology-5 Lithium-Ion Battery Design, Qualification and Integration and Testing

This document is a viewgraph presentation that reviews the Lithium Ion Battery for the Space Technology-5 (ST-5) mission. Included in the document is a review of the ST-5 Mission, a review of the battery requirements, a description of the battery and the battery materials. The testing and the integration and qualification data is reviewed.

Rao, Gopalakishna M.↗

Deep reconditioning of batteries during DSCS 3 flight operations

Deep reconditioning of batteries is defined as discharge below the 1.0 volt/cell level to a value of about 1.0 volt/battery. This type of reconditioning was investigated for use on the Defense Satellite Communications System (DSCS) spacecraft, and has been used during the first year of orbital operation. Prior to launch of the spacecraft, the deep reconditioning was used during the battery life test, which has now complete fourteen eclipse periods. Reconditioning was performed prior to each eclipse period of the life test, and is scheduled to be used prior to each eclipse period in orbit. The battery data for discharge and recharge is presented for one of the life test reconditioning cycles, and for each of the three batteries during the reconditioning cycles between eclipse period no.1 and eclipse period no.2 in Earth orbit.

Thierfelder, H. E.↗

Preliminary evaluation of a micro-based repeated measures testing system

A need exists for an automated performance test system to study the effects of various treatments which are of interest to the aerospace medical community, i.e., the effects of drugs and environmental stress. The ethics and pragmatics of such assessment demand that repeated measures in small groups of subjects be the customary research paradigm. Test stability, reliability-efficiency and factor structure take on extreme significance; in a program of study by the U.S. Navy, 80 percent of 150 tests failed to meet minimum metric requirements. The best is being programmed on a portable microprocessor and administered along with tests in their original formats in order to examine their metric properties in the computerized mode. Twenty subjects have been tested over four replications on a 6.0 minute computerized battery (six tests) and which compared with five paper and pencil marker tests. All tests achieved stability within the four test sessions, reliability-efficiencies were high (r greater than .707 for three minutes testing), and the computerized tests were largely comparable to the paper and pencil version from which they were derived. This computerized performance test system is portable, inexpensive and rugged.

Kennedy, Robert S.↗

Automated microbial metabolism laboratory

The design and rationale of an advanced labeled release experiment based on single addition of soil and multiple sequential additions of media into each of four test chambers are outlined. The feasibility for multiple addition tests was established and various details of the methodology were studied. The four chamber battery of tests include: (1) determination of the effect of various atmospheric gases and selection of that gas which produces an optimum response; (2) determination of the effect of incubation temperature and selection of the optimum temperature for performing Martian biochemical tests; (3) sterile soil is dosed with a battery of C-14 labeled substrates and subjected to experimental temperature range; and (4) determination of the possible inhibitory effects of water on Martian organisms is performed initially by dosing with 0.01 ml and 0.5 ml of medium, respectively. A series of specifically labeled substrates are then added to obtain patterns in metabolic 14CO2 (C-14)O2 evolution.

Source record↗

Orion Portable Fire Extinguisher Performance Testing Against a Laptop Lithium-Ion Battery Stored-Energy Fire-Method, Magnesium Fires, and Combustion By-Product Toxicity

As part of the qualification of the International Space Station (ISS) fine water mist portable fire extinguisher (PFE), several test methods were developed to determine firefighting capability against stored-energy sources. The most challenging of these devised stored-energy fire test methods proved to be the Lithium-ion (Li-ion) battery fire test scenario. The Orion crew capsule will utilize a different PFE technology from ISS (water spray rather than water mist), which spurred the need for the same type of evaluation focused on the sources of stored energy slated for use on Orion. Laptops were identified as a realistic source for stored-energy fires, requiring a modified Li-ion battery fire test scenario. In addition to open test cell (ambient oxygen concentration) testing to evaluate new proposed PFE performance, sealed chamber (20.9% and elevated oxygen concentration) testing was also performed. Chamber testing included combustion product sampling at various fire progression points for analysis and application to Orion emergency equipment design and response planning. The PFE stored-energy fire test methodology was modified and testing performed. Initial tests indicated ignition of the laptop magnesium laptop cases was possible. Additional tests were performed to characterize the laptop magnesium case fire behavior in various configurations. The new water spray PFE technology proved effective in extinguishing laptop stored-energy fires, and much was learned in the way these types of fires progressed. Findings indicate potential laptop magnesium case ignition mitigation strategies need to be further investigated.

Harper, Susana A.↗

Design, Build and Qualification of 28 Volt Lithium-Ion battery

Contents include the following: 1. GSFC performance specifications requirements. 2. AEA philosophy: battery configuration. 3. AEA battery design: SONY cell, cell screening, 20Ah and 60Ah. 4. Testing: 20Ah battery qualification (environmental); 60Ah battery LEO life cycle. 5. Conclusion.: summary and lessons learned.

Curzon, D.↗

NASA Handbook for Nickel-Hydrogen Batteries

Nickel-hydrogen (NiH2) batteries are finding more applications in the aerospace energy storage. Since 1983, NiH2 batteries have become the primary energy storage system used for Geosynchronous-Orbit (GEO) Satellites. The first NASA application for NiH2 batteries was the Low Earth Orbit (LEO) Hubble Space Telescope Satellite launched in 1990. The handbook was prepared as a reference book to aid in the application of this technology. That is, to aid in the cell and battery design, procurement, testing, and handling of NiH2 batteries. The design of individual pressure vessel NiH2 cells is covered in Chapter l. LEO and GEO applications and their requirements are discussed in Chapter 2. The design of NiH2 batteries for both GEO and LEO applications is discussed in Chapter 3. Advanced design concepts such as the common pressure vessel and bipolar NiH2 batteries are described in Chapter 4. Performance data are presented in Chapter 5. Storage and handling of the NiH2 cells and batteries are discussed in Chapter 6. Standard test procedures are presented in Chapter 7. Cell and battery procurements are discussed in Chapter 8. Finally, safety procedures are discussed in Chapter 9.

Dunlop, James D.↗