Search NASA⌕ Search

SEARCH · Search NASA

Results for “Battery Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Concavity-based local erosion and sphere-size-based local dilation applied to lithium-ion battery electrode microstructures for particle identification

Performance metrics of lithium-ion batteries can be extracted from the analysis of electrode microstructures nanoscale imaging. The characterization workflow can involve a challenging particle identification, or instance segmentation, step. In this work, we propose a new identification method based on an original transformation: a sphere-size-based local dilation followed by a concavity-based local erosion, that is local morphology closing. The new transformation is much more efficient than the global morphology closing, with correct identification achieved with only 1.7 % dilation volume and 2.6 % erosion volume on a test geometry, compared to 39.2 % and more than 50 %, respectively, with its global counterpart. The new method has been then benchmarked versus other identification algorithms (watershed and pseudo coulomb repulsive field) on a real electrode microstructure with equal or better segmentation achieved.

25 ENERGY STORAGE↗

High Throughput Electrochemical Screening of Phosphate-Rich Nonflammable Electrolytes in Lithium-Ion Batteries

Frequent fires and explosions in lithium-ion batteries (LIBs) used in grid energy storage systems (ESS) highlight the necessity of revisiting nonflammable phosphate electrolytes as alternatives to the currently used flammable carbonates. However, previous studies have shown the difficulty of integrating phosphate solvents into LIB electrolytes due to compatibility issues with graphite. In this work, we developed a high-throughput (HTP) electrochemical characterization method, akin to pH test paper, to rapidly screen potential phosphate electrolytes and graphite materials. Through HTP screening, we identified 101 promising combinations out of 1,740. This number was reduced to 26 after testing in Li/Graphite half cells. The optimized phosphate-rich electrolyte (60 v% phosphate) with cosolvents demonstrated 300 stable cycles at 0.1 C in Graphite/LiFePO 4 (LFP) full cells with thick electrodes (∼3.0 mAh cm −2 ), surpassing prior research findings. This unique HTP method provides a powerful tool to expedite the development of safe LIBs for ESS applications.

25 ENERGY STORAGE↗

Decoupling first-cycle capacity loss mechanisms in sulfide solid-state batteries

Solid-state batteries (SSBs) promise more energy-dense storage than liquid electrolyte lithium-ion batteries (LIBs). However, first-cycle capacity loss is higher in SSBs than in LIBs due to interfacial reactions. The chemical evolution of key interfaces in SSBs has been extensively characterized. Electrochemically, however, we lack a versatile strategy for quantifying the reversibility of solid electrolyte (SE) redox for established and next-generation SSB electrolytes. In this work, we perform tailored electrochemical tests and operando X-ray diffraction to disentangle reversible and irreversible sources of capacity loss in positive electrodes composed of Li 6 PS 5 Cl SE, Li(Ni 0.5 Mn 0.3 Co 0.2 )O 2 (NMC), and carbon conductive additives. We leverage an atypically low voltage cutoff (2.0 V vs. Li/Li + ) to quantify the reversibility of SE redox. Using slow (5.5 mA g NMC −1 ) cycling paired with >100 h low-voltage holds, our cells achieve a surprising 96.2% first-cycle coulombic efficiency, which is higher than previously reported (mean: 72%, maximum: 91.6% across surveyed literature). We clarify that sluggish NMC relithiation kinetics have been historically mistaken for permanently irreversible capacity loss. In conclusion, through systematic decoupling of loss mechanisms, we uncover the unexpected reversibility of SE redox and isolate the major contributors to capacity loss, outlining a strategy for accurate assessment of next-generation SE materials and interface modifications.

54 ENVIRONMENTAL SCIENCES↗

Optimized V1G and V2G Electric Vehicle Fleet Management and Grid Transaction at Marine Corps Air Station Miramar in San Diego, CA

The overall technical goal of the project was to demonstrate an all-electric bi-directional non-tactical fleet at Marine Corps Air Station (MCAS) Miramar that was integrated and controlled with other distributed energy resources (DERs) (i.e., PV, stationary battery, and building loads) to provide resilience to critical electric loads in the event of grid outages, to minimize charging costs, and to provide economic energy resources to electricity markets. In this project, the specific, technical objectives were: 1. Demonstrate that bi-directional electric vehicles can provide critical complementary services to fixed storage batteries in microgrid applications while performing function as non-tactical vehicles. 2. Demonstrate participation of bi-directional (V2G) and unidirectional (V1G) PEVs for demand management and minimization of charging costs. 3. Demonstrate integration of multiple DERs for grid service participation. US Marine Corps Air Station (MCAS) Miramar in San Diego was the site of this electric vehicle-to-microgrid-utility grid test and demonstration project. Existing microgrid assets in this study included (1) a public works building; (2) a 30-kW rooftop photovoltaic (PV) system and (3) a separate 250 kW carport PV system. In this project, six bi-directional V2G vans were located at the MCAS Miramar’s showcase building-scale microgrid to develop and test technical capabilities that V2G can provide in microgrid applications (e.g., cost reduction and resiliency). These resources provided aggregated demand management and simulated participation in current retail DR programs. The vehicles used in this demonstration were selected because they provided functionality that MCAS Miramar needed, 15 passenger transport and facilities work cargo carrying capacity, and bi-directional charging capability that the research project required. All vehicles in this study were manufactured and distributed by VIA Motors, Inc. There were six vehicles total and each was VIA’s VTRUX eREV V2G model, a modified General Motors Chevrolet 2500 2WD van. Three of the vans were configured as passenger vans and the other three were configured as cargo vans. Each van had an on-board bi-direcrtional inverter/charger, Bel Power Solutions model 350INVCHGT150-120-240-8G nominally rated at +/-15 kW. The VIA van’s charging connector follows the J1772 charging protocol. The bi-directional EVSEs demonstrated in this study were manufactured by Coritech, Inc. Each VGI-80-AC charging station enabled enhanced V2G charging capability to a Clipper Creek CS-100 charging module. The enhanced capabilities included ethernet communication following the SEP2.0 protocol with a distributed energy resource function set and an operator screen displaying real-time SOC, voltage, and current. The VGI-80-AC charging stations are classified as level 2 with a maximum current output of 80 A or effectively 19 kW. The VIA van’s onboard charger limited the charging and discharging power to 15 kW in each direction. A control computer was installed in the EWOC and connected to an existing monitor. The V2G control communication network was a completely stand-alone closed system that did not have any connection to any other networks on the base. A cybersecure remote communication connection was created with a cellular modem, firewall hardware, and a virtual private network configuration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Surrogate modeling and optimization of the leaching process in a rare earth elements recovery plant

Critical minerals (CMs) and Rare Earth Elements (REEs) play a vital role in crucial infrastructure technologies such as renewable energy generation and batteries. Recovering them from waste materials has recently been found to significantly reduce environmental impact and supply chain costs related to these materials. In this work, we investigate surrogate modeling techniques aimed to simplify the modeling, simulation, and optimization of the leaching processes involved in CM and REE recovery flowsheets. As there is currently a lack of systematic studies on this topic, we perform extensive computational testing to ascertain which surrogate models are easier to construct and offer high predictive accuracy. Further, our results suggest that sparse quadratic models balance predictive accuracy and computational efficiency. Training and using these surrogates for global optimization of the leaching process requires two orders of magnitude fewer measurements and is up to four orders of magnitude faster than optimizing the original simulation using equation-oriented optimization or derivative-free optimization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Is a Generator the Only Solution When the Grid Fails? Optimizing Systems for Resiliency and Carbon Reduction: Preprint

Traditionally, buildings are dependent on utility infrastructure, and when a grid failure happens, end users rely on the closest source of energy storage to sustain operation until power is restored. For buildings, that typically means using an electric generator. This electric generator either uses on-site energy storage such as fossil fuels in a tank or a gas connection which is, in turn, tied to gas wells—also a form of energy storage. Generators are popular for their ease of implementation and low capital costs; however, they have limited value outside of disruptions, and they are a source of scope 1 emissions, or direct greenhouse gas emissions from sources controlled by the building owner. In contrast, some power generation and storage systems, such as photovoltaic (PV) panels and battery energy storage systems (BESS), can serve the same purpose during grid disruptions while presenting advantages outside of power failure. This paper explores methods for storing and converting energy on-site to increase building resiliency, focusing on solutions that minimize scope 1 emissions. We analyze the cost and carbon impacts of energy efficiency measures, PV arrays, and BESS, with and without generators, in a simulation test case. We find significant benefits can be achieved both during and outside of power failure events when designing systems that integrate the on-demand capability of generators, the low carbon energy supplied by PV, and the storage capabilities of BESS. Specifically, adding even minimal BESS and PV can result in downsizing the generator, increasing generator efficiency and requiring less fuel.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Battery Material Synthesis and Scalability using a 50L Taylor Vortex Reactor (Final CRADA Report)

Under this agreement, Laminar will loan Argonne a 50L Taylor Vortex Reactor (TVR) and provide mechanical troubleshooting guidance and consulting to ensure the successful setup of the pilot-scale synthesis process. The U.S. Department of Energy (DOE) will allocate funding for the labor and materials required for the study. To evaluate the physical and electrochemical properties of the materials produced by the 50L TVR, Argonne will perform comprehensive characterizations, including XRD, SEM, PSA, ICP, tap density, and coin half-cell testing. Throughout the collaboration, Argonne will provide feedback and recommendations for mechanical improvements to the reactor system. Furthermore, Argonne will credit Laminar as a collaborator in any presentations or publications resulting from data generated by the system. Laminar will retain no rights to experimental results or intellectual property generated through the experiments conducted with the 50L TVR at Argonne.

25 ENERGY STORAGE↗

Building High-Energy Silicon-Containing Batteries Using Off-The-Shelf Materials

The technology of silicon anodes appears to be reaching maturity, with high-energy Si cells already in pilot-scale production. However, the performance of these systems can be difficult to replicate in academic settings, making it challenging to translate research findings into solutions that can be implemented by the battery industry. Part of this difficulty arises from the lack of access to engineered Si particles and anodes, as electrode formulations and the materials themselves have become valuable intellectual property for emerging companies. Here, we summarize the efforts by Argonne’s Cell Analysis, Modeling, and Prototyping (CAMP) Facility in developing Si-based prototypes made entirely from commercially available materials. We describe the many challenges we encountered when testing high-loading electrodes (>5 mAh cm −2 ) and discuss strategies to mitigate them. With the right electrode and electrolyte design, we show that our pouch cells containing ≥ 70 wt% SiO x can achieve 600–1,000 cycles at C/3 and meet projected energy targets of 700 Wh L −1 and 350 Wh kg −1 . These results provide a practical reference for research teams seeking to advance silicon-anode development using accessible materials.

25 ENERGY STORAGE↗

In Situ Synthesis of Phosphate-Based CelloMOF as a Promising Separator for Li–Ion Batteries

Nowadays, battery separators play a critical role in determining the sustainability, electrochemical efficiency, and safety of lithium-ion batteries (LIBs). In this contribution, we developed fire-resistant composite membranes called CelloMOF by in situ grafting of metal-organic framework, ZIF-67, onto phosphorylated cellulose nanofibers (P-CNFs) followed by a vacuum filtration process akin to papermaking. The hybrid ZIF-67@P-CNF membrane exhibits superior properties than a polyolefin-based commercial separator (CS) in terms of enhanced thermal and dimensional stability, flame-retardant properties, better surface wettability, and improved electrolyte uptake. Thermal dimensional stability tests revealed that the ZIF-67@P-CNF separator maintained its structure even at 200 °C, whereas CS suffered severe shrinkage, potentially leading to internal short circuits. Combustion tests showed a peak heat release rate (PHRR) of 34.5 W/g and a total heat release (THR) of 1.61 kJ/g for ZIF-67@P-CNF, significantly lower than the PHRR (1111.82 W/g) and THR (40.89 kJ/g) of CS. The composite separator also demonstrated significantly improved wettability, with a contact angle of 32 ± 1.04°, compared to 92 ± 1.07° for CS, highlighting its hydrophilic nature. Electrochemical evaluations in LiFePO 4 /Li half-cells indicated a higher discharge capacity of 149 mA h g -1 at 0.2 C and superior capacity retention of 86% after 50 cycles, outperforming CS (145 mA h g -1 and 84%, respectively). In conclusion, these results underscore the potential of the ZIF-67@P-CNF membrane to advance safe, high-performance LIBs by addressing critical challenges in thermal stability, flame retardancy, and electrolyte compatibility.

ZIF-67↗

Impacts of Control, Penetration, and Distribution of Embedded Storage Network in Bulk Power System

The current shift in generation mix from fossil fuel plants towards variable and intermittent renewable energy sources is poised to create a future grid with reduced physical inertia and mismatch between generation and demand. Embedded storage, which is a concept of a coordinated network of storage units sited at the interface between the transmission and distribution system, is proposed as a mechanism to provide a buffer between generation and demand. This paper proposes an automated framework to model and integrate embedded storage in large-scale power systems with industry-grade grid-following (GFL) and grid-forming (GFM) control technologies. More importantly, the developed framework is used to explore the impacts of embedded storage control, penetration, location, and capacity in providing fast frequency response to the grid under contingency events such as generator trips and faults. The framework and study are conducted using the transient-stability simulation tool PSS/E and a realistic model of the Puerto Rico grid as a chosen test system. The simulation results show that GFL and GFM embedded storage, distributed throughout the system, with sufficient penetration and capacity, can effectively improve primary frequency response of the system under the studied contingency events.

Battery Energy Storage, embedded storage, grid-for↗

Titanium-Cerium Electrode-Decoupled Redox Flow Batteries Integrated With Fossil Fuel Assets For Load-Following, Long-Duration Energy Storage

Operation of fossil plants at partial capacity with frequent cycling results in decreased efficiency, increased emissions and increased wear and maintenance. The objective of this project is to advance the integration of a titanium-cerium electrode-decoupled redox flow battery (RFB) system with conventional fossil-fueled power plants through technical and economic system-level studies and component scale-up and R&D. The Ti-Ce chemistry has a pathway to meet the DOE cost targets of $\$$100/kWh and $\$$0.05/kWh-cycle owing to the use of low-cost, earth abundant elemental actives and incorporation of inexpensive carbon felt electrodes and non-fluorinated anion exchange membrane (AEM) separators. The initial unit cell design was scaled up, with some modifications made to improve ease of manufacturing, from 25 cm 2 cell area to 400 cm 2 . Electrochemical tests demonstrated operation at a current density up to 50 mA/cm 2 , which is on par with other commercial RFB offerings. Furthermore, the Ti-Ce technology developed by WashU was evaluated and tested by industrial team partner, Giner, Inc., in their modular 3-cell stack. Several cell design modifications and alternate component material selections were successfully implemented to accommodate this chemistry while reducing polarization and leakage. Results from stack testing show high columbic efficiency and indicate that further optimization of cell compression and components will lead to successful operation of the Ti-Ce ED-RFB over longer duration at the multi-cell stack level. Engineering and cost analysis showed that an RFB system with power output on the order of 100 MW and with a charge/discharge duration of approx. 12 hours is the most cost effective for integration with fossil plants. At this scale, projected cycling of fossil fuel power plants can be significantly reduced. The use of a storage system is shown to reduce the fossil plant standalone cost of electricity by $\$$7/MWh, through increased capacity factor and improved average efficiency, in the scenario of high penetration of renewable power.

20 FOSSIL-FUELED POWER PLANTS↗

Chemo-Mechanics of α-V 2 O 5 During Lithiation and Implications for Rechargeable Battery Cathodes

Chemo-mechanical degradation of layered oxide electrodes is strongly influenced by crystallographic anisotropy, local stress evolution, and ion insertion, yet the intrinsic mechanical response of layered materials remains incompletely understood. Indeed, most prior studies have focused on polycrystalline materials but single crystals enable direct observation of coupling between anisotropic ion diffusion and mechanical response. This study aims to determine how crystallographic anisotropy and lithiation affect deformation, fracture, and mechanical properties in single-crystal V 2 O 5 , and compares this behavior with polycrystalline counterparts. Polycrystalline V 2 O 5 thin films and single-crystal α-V 2 O 5 were studied using nanoindentation, scanning electron microscopy, focused ion beam cross-sectioning, and Raman spectroscopy. Single crystals were tested in pristine and chemically lithiated states, including experiments in which crystals were first plastically deformed via nanoindentation and subsequently lithiated. Polycrystalline films exhibited significantly higher hardness and elastic modulus than single crystals. Single crystals indented normal to the exposed (001) basal plane exhibited pronounced anisotropic deformation, including directional slip, crystallographically-guided cracking, anisotropic crack propagation, interlayer separation, and shear localization. Lithiation caused substantial softening, reduced hardness and modulus, and suppressed displacement bursts during nanoindentation, while previously indented regions showed crack formation and growth upon lithiation. Mechanical behavior of α-V 2 O 5 is strongly governed by crystallographic anisotropy and further altered by lithiation, with pre-existing deformation serving as a strong driver of fracture during ion insertion. These findings illuminate the coupling among ion insertion, deformation, and fracture in layered oxides and provide a basis for understanding and mitigating mechanical failure in electrochemical energy-storage materials.

Anisotropy↗

Lithium Plating Characteristics in High Areal Capacity Li-Ion Battery Electrodes

Li-ion battery degradation and safety events are often attributed to undesirable metallic lithium plating. Since their release, Li-ion battery electrodes have been made progressively thicker to provide a higher energy density. However, the propensity for plating in these thicker pairings is not well understood. Herein, we combine an experimental plating-prone condition with robust mesoscale modeling to examine electrode pairings with capacities ranging from 2.5 to 6 mAh/cm 2 and negative to positive (N/P) electrode areal capacity ratio from 0.9 to 1.8 without the need for extensive aging tests. Using both experimentation and a mesoscale model, we identify a shift from conventional high state-of-charge (SOC) type plating to high overpotential (OP) type plating as electrode thickness increases. Further, these two plating modes have distinct morphologies, identified by optical microscopy and electrochemical signatures. We demonstrate that under operating conditions where these plating modes converge, a high propensity of plating exists, revealing the importance of predicting and avoiding this overlap for a given electrode pairing. Further, we identify that thicker electrodes, beyond a capacity of 3 mAh/cm 2 or thickness >75 μm, are prone to high OP, limiting negative electrode (NE) utilization and preventing cross-sectional oversizing the NE from mitigating plating. Here, it simply contributes to added mass and volume. The experimental thermal gradient and mesoscale model either combined or independently provide techniques capable of probing performance and safety implications of mild changes to electrode design features.

25 ENERGY STORAGE↗

Performance and Durability of Heavy-Duty Fuel Cell Systems with an Advanced Ordered Intermetallic ORR Alloy Catalyst and Novel Support

Ordered PtCo intermetallic (OIM) catalyst (L1 0 -PtCo/C) is a promising candidate as the oxygen reduction reaction (ORR) catalyst in hybrid fuel cell systems (FCS) for class-8 heavy duty (HD) trucks. Compared to a baseline annealed Pt on high surface area carbon (a-Pt/HSC) catalyst, its mass activity (MA) is 71% higher initially and 144% higher after 90,000 potential cycles in an accelerated stress test (AST). Analysis of the AST data indicates that the ORR kinetic constants do not change with aging and the degradation in the OIM catalyst activity is linearly proportional to the loss in the electrochemically active surface area (ECSA). Several operational strategies are investigated to mitigate catalyst degradation and achieve 25,000-h electrode lifetime and 2.5 kW g −1 Pt utilization on a HD truck duty cycle including load sharing with the hybrid battery, regulating the radiator fan power to maintain the coolant temperature close to 60 °C, clipping the maximum cell voltage below 850 mV, limiting the ECSA loss to 55%, and oversizing the active area of the membrane electrode assemblies by 20%. Drive cycle simulations indicate that the lifetime average voltage degradation rate is about 1.8 μV h −1 and the integrated stack and FCS drive cycle efficiencies decrease by 3.5 to 3.9%.

25 ENERGY STORAGE↗

Selective leaching and solvent extraction of Lithium from spent batteries

Pre-extracting Li from spent lithium-ion batteries (LIBs) is crucial because the recovery efficiency of Li is low after other critical metals have been extracted. Traditional methods involving black mass roasting followed by water leaching have resulted in the extraction of 76 % Li and 61 % Al. However, pre-leaching Li from pretreated black mass using an oxalic acid solution at both ambient and elevated temperatures significantly improved results, achieving 98.1 % Li, 99.5 % Al, and 100 % Fe extraction while leaving Ni, Co, Mn, and Cu behind under optimal conditions. Oxalic acid crystals were recovered by refrigerating the leach solution at temperatures below 5 °C and were reused with nearly identical leaching efficiency. Selective extraction of Li from the oxalate leach solution was achieved using Cyanex® 936P under optimal conditions. Here, due to its extremely low Li extraction efficiency, Dichloromethane proved unsuitable as a diluent. Comparative extraction tests using Cyanex® 936P, Cyanex® 272, and DEHPA in kerosene demonstrated that Cyanex® 936P is an excellent extractant for Li, effectively separating it from other impurities. Under optimal conditions, 98.8 % of available Li was extracted using 20 % Cyanex® 936P, compared to 51.1 % with Cyanex® 272 and 39.9 % with DEHPA in kerosene. Additionally, stripping Li from Cyanex® 936P using H 2 SO 4 and HCl was explored, with HCl yielding the best performance.

Black mass↗

UL 1741SC Conformance Development, Evaluation, and Proposal [Slides]

V2G AC is a type of grid interconnection by mobile battery that transforms an EV into a DER with the potential to stabilize the grid and lower costs for electricity. UL 1741SC is a critical new standard to enable grid interconnection of V2G AC-capable vehicles, by defining requirements for V2G AC-intended EVSEs as a gatekeeper between the grid and the EV to support grid safety, such as through redundant voltage trip (namely oversight). EVSE manufacturers need a clear set of conformance test cases and criteria by which to evaluate their equipment and confirm the compliance with UL 1741SC, so that the EVSEs performs as intended for the grid safety. Hence, NLR identified necessary conformance tests and performed the tests identified to understand the maturity.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

SuperLab 2.0 Showcase: Connecting Five Labs to Tackle Grid Complexity and Unlock Unique Grid Asset Potential

SuperLab 2.0 (5-Lab Demo) is a collaborative, national-scale experiment showcasing the coordination of geographically distributed energy assets in real time. The demonstration integrates 25 physical and digital assets, spanning wind, PV, batteries, electrolyzers, DC fast chargers, microgrid controllers, building automation systems, small modular reactor (SMR), control centers, and gas turbines, across five DOE national laboratories-NLR, INL, NETL, LBNL, and SNL. These assets are unified using Energy Sciences Network (ESnet), a low-latency, high-performance U.S. Department of Energy's (DOE) network, and controlled via a centralized energy controller hosted at NLR's ARIES facility. The demonstration validates the ability to stress-test hybrid energy systems under dynamic scenarios to de-risk advanced control strategies for greater resilience and flexibility. SuperLab 2.0 (5-Lab Demo) showcased a major advancement in federated national laboratory collaboration, enabling real-time, cross-laboratory experimentation to coordinate geographically dispersed distributed energy resources (DERs) using various communication protocols and networks. SuperLab 2.0 (5-Lab Demo) built on previous demonstrations conducted between NLR-PNNL and NLR-INL connecting diverse assets including distant protection devices, a SMR simulator, and a high temperature electrolyzer (HTE). Previous demos were based on a single connection between two labs with minimal coordination challenges. The 5-Lab demo with a centralized controller, distributed testbeds across different geographical locations, and use of protocols-based communication represents a scenario closer to real-world grid operations that coordinate resources across a region to meet system needs. This experiment studied how local DER controllers interact with a centralized energy controller during normal and abnormal events to maintain reliability. The SuperLab team across the five labs implemented a notional power system model equivalent of transmission and distribution lines, represented by the data networks interconnecting the labs. Each lab continuously exchanged local parameters (such as P and Q) from its Hardware-In-Loop (CHIL) and Power Hardware-In-Loop (PHIL) assets through centralized energy controller at NLR, enabling real-time interaction and coordination across sites. By leveraging ESnet as the communication backbone, the team successfully operated the distributed assets as a unified power system, with each bus represented by a different laboratory. This setup mirrors how assets interact in real-world power systems across dispersed locations with various protocols and latencies. At each lab site, assets were operated using their own local controllers which were coordinated through an overarching operation and control layer of centralized energy controller, equivalent to how an energy management system (EMS) orchestrates assets across a regional or national grid. SuperLab's federated connectivity utilized a Digital Real-Time Simulators (DRTS)-type gateway to connect Controller Hardware-In-Loop (CHIL) and PHIL assets between labs. To enable this federated connection through ESnet, a deterministic network was established where latency variations were consistent. This consistency allowed the development of digital filters for the power system assets across CHIL and PHIL interfaces to avoid unstable and unreliable grid conditions. This report provides an overview of the cross-laboratory configuration and offers insights into interconnecting geographically distributed research assets to test them as if they were co-located. This experiment represents a step toward linking nine DOE national laboratories, enabling nation-wide simulations that can address utility-driven challenges with grid resilience, flexibility, and modernization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Lattice Structured Lightweight Structural Materials

The development of lightweight structural materials is crucial for enhancing the performance and deployment feasibility of fission batteries. This study aims to produce lightweight structural materials whose strength-to-weight ratios exceed those of current widely used structural materials. To achieve this, advanced modeling and simulation tools were employed to design lattice structures with different lattice parameters and different lattice types. A process was successfully developed for transforming lattice-structured models into Multiphysics Object Oriented Simulation Environment (MOOSE) inputs. Finite element modeling (FEM) was used to simulate the uniaxial tensile testing of the lattice-structured parts to investigate the stress distribution at a given displacement. The modeling results showed that the lattice-structured sample displayed a lower Young’s modulus in comparison to the solid material; the increase in solid shell thickness and blend radius enhances the mechanical performance; and the effect of unit cell size on macro scale stress is minimal. Tensile testing was conducted on the solid and lattice-structured materials fabricated by laser powder bed fusion (LPBF) additive manufacturing. The experimental results agreed well with the model prediction. The approach of using modeling as a guiding tool for preliminary material design can significantly save time and cost for new material development.

lightweight material↗