Search NASA⌕ Search

SEARCH · Search NASA

Results for “Battery safety”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Performance Testing of Yardney MCMB-LiNiCoAlO2 Lithium-ion Cells Possessing Electrolytes with Improved Safety Characteristics

Many future NASA missions aimed at exploring the Moon and Mars require high specific energy rechargeable batteries that possess enhanced safety characteristics. There is also a strong desire to develop Li-ion batteries with improved safety characteristics for terrestrial applications, most notably for HEV and PHEV automotive applications. In previous work focused upon evaluating various potential flame retardant additives1, triphenyl phosphate (TPP)2 was observed to have the most desirable attributes, including good life characteristics and resilience to high voltage operation. We have employed a number of approaches in the design of promising TPP-based electrolytes with improved safety, including: (a) varying the flame retardant additive (FRA) content (from 5 to 15%), (b) the use of fluorinated co-solvents, (c) the use of additives to improve compatibility, and (c) the use of ester co-solvents to decrease the viscosity and increase the conductivity. In recent work, we have demonstrated a number of these electrolyte formulations to be compatible with a number of chemistries, including: MCMB carbon-LiNi0.8Co0.2O2, graphite-LiNi0.8Co0.15Al0.05O2, Li-Li(Li0.17Ni 0.25 Mn 0.58 )O2, Li-LiNiCoMnO2 and graphite- LiNiCoMnO2.3,4 In the current study, we have demonstrated the performance of a number of TPP-containing electrolytes in 7 Ah prototype MCMB-LiNiCoO2 cells. We will describe the results of a number of performance tests, including: a) 100% DOD cycle life testing at various temperatures, b) discharge rate characterization as a function of temperature, c) charge rate characterization as a function of temperature, and d) impedance as a function of temperature. In addition to displaying good life characteristics, being comparable to baseline chemistries, a number of cells were observed to provide good performance over a wide temperature range.

Li-ion batteries↗

Energy Storage Technology Development for Space Exploration

The National Aeronautics and Space Administration is developing battery and fuel cell technology to meet the expected energy storage needs of human exploration systems. Improving battery performance and safety for human missions enhances a number of exploration systems, including un-tethered extravehicular activity suits and transportation systems including landers and rovers. Similarly, improved fuel cell and electrolyzer systems can reduce mass and increase the reliability of electrical power, oxygen, and water generation for crewed vehicles, depots and outposts. To achieve this, NASA is developing non-flow-through proton-exchange-membrane fuel cell stacks, and electrolyzers coupled with low permeability membranes for high pressure operation. The primary advantage of this technology set is the reduction of ancillary parts in the balance-of-plant fewer pumps, separators and related components should result in fewer failure modes and hence a higher probability of achieving very reliable operation, and reduced parasitic power losses enable smaller reactant tanks and therefore systems with lower mass and volume. Key accomplishments over the past year include the fabrication and testing of several robust, small-scale non-flow-through fuel cell stacks that have demonstrated proof-of-concept. NASA is also developing advanced lithium-ion battery cells, targeting cell-level safety and very high specific energy and energy density. Key accomplishments include the development of silicon composite anodes, lithiatedmixed- metal-oxide cathodes, low-flammability electrolytes, and cell-incorporated safety devices that promise to substantially improve battery performance while providing a high level of safety.

Mercer, Carolyn R.↗

Developing high safety Li-metal anodes for future high-energy Li-metal batteries: strategies and perspectives

Developing high-safety Li-metal anodes (LMAs) is extremely important for the application of high-energy Li-metal batteries (LMBs), especially Li–S and Li–O 2 battery systems. However, the notorious Li-dendrite growth problem results in serious safety concerns for any energy storage application. Through a recent combination of interface-based science, nanotechnology-based solutions and characterization methods, the LMA is now primed for a technological boom. In this review, the recent emerging strategies and perspectives on LMAs are summarized, following which the current huge evolution in interfacial chemistry regulation, optimizing electrolyte components, designing a rational ‘host’ for lithium metal, optimizing “solid-state electrolytes” and other emerging strategies for developing high-safety LMAs is highlighted. Furthermore, several state-of-the-art in situ/operando synchrotron-based X-ray techniques for high safety LMB research are introduced. With the further development of LMAs in the future, subsequent application in high energy LMBs is to be expected.

25 ENERGY STORAGE↗

Advanced silver zinc battery development for the SRB and ET range safety subsystems

This document presents in viewgraph format the design and development of silver zinc (AgZn) batteries for the solid rocket booster (SRB) and external tank (ET) range safety subsystems. Various engineering techniques, including composite separator systems, new electrode processing techniques, and new restraint techniques, were used to meet difficult requirements.

Adamedes, Zoe↗

Safety Evaluation of Two Commercial Lithium-ion Batteries for Space Applications

Lithium-ion batteries have been used for applications on the Shuttle and Station for the past six years. A majority of the li-ion batteries flown are Commercial-off-the-shelf (COTS) varieties. The COTS batteries and cells were tested under nominal and abusive conditions for performance and safety characterization. Within the past six months two batteries have been certified for flight and use on the Space Station. The first one is a Hand Spring PDA battery that had a single prismatic li-ion cell and the second is an Iridium satellite phone that had a two-cell pack with prismatic li-ion cells.

Jeevarajan, Judith A.↗

Valuation of Anode Materials for High-Performance Lithium Batteries: From Graphite to Lithium Metal and Beyond

Lithium-ion batteries have revolutionized energy storage, yet advanced technologies such as electric vehicles and eVTOLs demand even higher performance and safety. Anodes, the negative electrodes, are crucial in enhancing batteries’ safety, lifespan, and fast-charging capabilities. This review paper comprehensively evaluates the progression of anode materials from traditional graphite to advanced anodes like lithium metal. Graphite anodes, with a capacity of 372 mAh g −1 , enabled the first commercial lithium-ion batteries, but future applications require higher energy densities and fast-charging capabilities. Emerging anode materials, including alloying, and conversion types, as well as lithium metal, offer significantly higher capacities, with lithium metal offering a theoretical capacity of 3 860 mAh g −1 . However, these advanced anodes face challenges such as volume expansion, high surface reactivity, sluggish Li+ kinetics, and unstable lithium deposition morphologies. Here, this review critically examines the electrochemical performance, interfacial properties, mechanical attributes, and stability issues of various anode materials. It further discusses solid electrolyte interphase (SEI) formation, strategies for enhancing interface stability, and the requirements of anodes for solid-state batteries. Additionally, the review explores potential solutions for limitations with each anode type, highlights innovative anode-free architectures, and evaluates the current and future trends of battery anode industries. Ultimately, this paper aims to guide the development of high-performance anode materials, paving the way for the next generation of efficient, reliable lithium batteries.

Alloying anodes↗

Gas-mediated defect engineering in earth-abundant Mn-rich layered oxides for non-aqueous sodium-based batteries

Gases are often by-products of battery materials during cell formation and degradation, affecting the cycle life and safety of rechargeable batteries. However, understanding gas-mediated (electro)-chemical reactions and nanoscale structural transformations during the synthesis of battery electrode materials remains challenging because of the lack of suitable characterization routes and the complexity of the interplay between thermodynamics and kinetics. Here, in this study, we use operando synchrotron X-ray diffraction, in situ transmission X-ray microscopy and multiscale modelling to elucidate the reaction pathways and microstructural defect development of earth-abundant Mn-rich layered oxides as positive electrode materials for sodium-based batteries. In particular, we demonstrate the dominant role of CO 2 over O 2 and H 2 O (g) in modulating the competition between entropy and enthalpy during solid-state synthesis. Using Ni 0.25 Mn 0.75 CO 3 as a model precursor, we reveal that CO 2 generation favours the formation of entropy-driven metastable intermediates, suppresses closed pore/nanovoids formation and decreases chemical heterogeneity and residual lattice strain of Mn-rich layered oxides during the synthesis. This result motivates a fast-sintering strategy to promote CO 2 release, which ultimately leads to improved chemo-mechanical and electrochemical stability of the Mn-rich positive electrodes when tested in non-aqueous Na metal coin cells.

36 MATERIALS SCIENCE↗

Damage of prismatic lithium‐ion cells subject to bending: Test, model, and detection

Abstract The mechanically induced internal short circuit (ISC) is one of the major safety concerns of lithium‐ion batteries. Mechanical abuse tests are often performed to evaluate the integrity and safety of lithium‐ion batteries under mechanical loadings. Except for the widely explored compression‐dominated indentation tests, bending is another typical real‐world loading condition that is tension‐dominated. To investigate the mechanical damage and ISC behavior of batteries under bending, we carried out controlled three‐point bending tests in four progressive steps on prismatic battery cells with maximum deflections ranging from 38% to 76% of the cell thickness. None of the tested cells experienced an ISC. We then conducted 3D X‐ray computed tomography (CT) scanning on the bent cells after unloading. X‐ray CT images showed three out of the four tested cells have extensive cracking in the electrode layers at the bottom side (opposite to the loading head). This indicates that cracking does not necessarily lead to an ISC under bending. Electrochemical impedance spectroscopy was also measured on the bent cells and substantial changes were observed. Both the bulk resistance and charge‐transfer resistance increased significantly after bending, which could influence the battery performance and lifespan. We then developed a detailed finite (FE) element model to further investigate the mechanical deformation and failure mechanisms. The FE model successfully predicts the load–displacement response and reproduces the deformation patterns. The findings and the FE model developed in the present study provide useful insights and tools for the battery structure and crash safety design. image

25 ENERGY STORAGE↗

High safety and cycling stability of ultrahigh energy lithium ion batteries

High-nickel layered oxide Li-ion batteries (LIBs) dominate the electric vehicle market, but their potentially poor safety and thermal stability remain a public concern. Here, we show that an ultrahigh-energy LIB (292 Wh kg –1 ) becomes intrinsically safer when a small amount of triallyl phosphate (TAP) is added to standard electrolytes. TAP passivates the electrode-electrolyte interfaces and limits the maximum cell temperature during nail penetration to 55°C versus complete cell destruction (>950°C) without TAP. The downside of this reliable safety solution is higher interfacial impedance and hence lower battery power; however, thermal modulation for battery operation around 60°C can restore power completely. When cycled at 60°C, the cell stabilized with TAP achieved 2,413 cycles at 76% capacity retention. Such an unconventional combination of interface-passivating electrolyte additive with cell thermal modulation renders the most energy-dense LIBs even safer than LiFePO 4 chemistry, while enjoying high power and cycling stability concurrently.

25 ENERGY STORAGE↗

The Role of Interfacial Thermal Resistance in Li-Ion Battery Thermal Management: Preprint

Temperature critically affects the performance, life and safety of lithium-ion batteries. Therefore, it is essential to understand heat generation and dissipation within individual battery cells and battery packs to plan a proper thermal management strategy. One of the key challenges is that interfacial heat transfer of a battery unit is difficult to quantify. The steady-state absolute method and the transient laser-flash-diffusivity method were employed to measure heat conductivities of battery layer stacks and individual battery layer separately. Results show flash diffusivity method gives higher thermal conductivity at both cross-plane and in-plane directions. The difference is primarily caused by interfacial thermal resistance so that it can be estimated by steady-state and transient measurements. To investigate the effects of interfacial thermal transport beyond individual cell level, a multiphysics battery model is used. The model is built upon a multi-scale multi-domain modeling framework for battery packs that accounts for the interplay across multiple physical phenomena. Benefits of a battery module using thermal management materials are quantified through numerical experiments. During a thermal runaway event, it is found interfacial thermal resistance can mitigate thermal runaway in a battery module by significantly reducing heat transfer between cells.

33 ADVANCED PROPULSION SYSTEMS↗

Perspective—On the Need for Reliability and Safety Studies of Grid-Scale Aqueous Batteries

Li-ion batteries currently dominate electrochemical energy storage for grid-scale applications, but there are promising aqueous battery technologies on the path to commercial adoption. Though aqueous batteries are considered lower risk, they can still undergo problematic degradation processes. This perspective details the degradation that aqueous batteries can experience during normal and abusive operation, and how these processes can even lead to cascading failure. We outline methods for studying these phenomena at the material and single-cell level. Considering reliability and safety studies early in technology development will facilitate translation of emerging aqueous batteries from the lab to the field.

25 ENERGY STORAGE↗

Explosion behavior investigation and safety assessment of large-format lithium-ion pouch cells

We report large-format lithium-ion (Li-ion) batteries with high energy density for electric vehicles are prone to thermal runaway (or even explosion) under abusive conditions. In this study, overcharge induced explosion behaviors of large-format Li-ion pouch cells with Li[Ni 0.8 Co 0.1 Mn 0.1 ]O 2 cathode at different current rates (C-rates) (0.5C, 1C, 2C) were investigated. The explosion characteristics of the cells were elucidated by discussing the evolution of the cell voltage, the surface temperature and the shock wave pressure. Generally, the whole overcharge process could be divided into four stages according to the evolution of several key parameters and the overcharge behaviors; the overcharge C-rate has a great influence on cells’ thermal behaviors. The experimental results showed that the thermal runaway process of Li-ion cells caused by overcharging consisted of two kinds of explosions, physical explosion and chemical explosion. The existence of observable negative pressure zone in the pressure curves indicated that the Li-ion cells are not a self-supplying oxygen system during the explosion. Further, the explosion dynamics parameters were matched. An explosion TNT-equivalent conversion strategy that depended on the pressure of the shock wave was utilized to evaluate the released energy and its hazards. In addition, with respect to the overcharge of Li-ion pouch cells, a safety assessment method and a safety management method were proposed based on the explosion behaviors. From the perspective of battery safety, this study is of great significance for the safety design of Li-ion cells and can provide guidance for engineers to optimize the safety function of battery packs.

25 ENERGY STORAGE↗

Voltage and Temperature Limits of Advanced Electrolytes for Lithium-Metal Batteries

Several advanced electrolytes (mainly ether-based) have recently demonstrated excellent electrochemical performance in high energy density lithium (Li)-metal batteries. However, the safety of these ether-based electrolytes is still unknown. This work evaluates the thermal stability of these new formulations to understand their safety limits of operation in comparison to carbonate electrolytes typically used in Li-ion batteries. Electrolyte stability is assessed in conjunction with LiNi 0.8 Mn 0.1 Co 0.1 O 2 cathode and Li-metal anode at ultra-high voltages (≤ 4.8 V) and temperatures (≤ 300°C) to trigger thermal runaway, where onset and extent of heat release are monitored via isothermal microcalorimetry and differential scanning calorimetry Most ether-based electrolytes show improved thermal resilience over commercial carbonate formulations when heated up to 300°C. The thermal behavior in presence of charged cathode and Li-metal suggests that the new electrolytes may be better at stabilizing active material surfaces than carbonate electrolytes. Although extreme voltages severely destabilize the ether-based formulations, prompting thermal runaway, a phosphate based localized high concentration electrolyte exhibits superior stability over commercial carbonate electrolytes at all tested temperatures (32°C, 45°C, and 60°C). Although thermal analysis during the first charge process (as adopted in this preliminary study) may be insufficient to conclude the long-term advantages of these electrolytes, a more stable electrolyte identified under extreme voltage and temperature conditions will provide valuable guidance for the safety of future electrolyte designs.

25 ENERGY STORAGE↗