Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Flare heating by energetic nonthermal electrons

A model has been developed which includes, in a self-consistent fashion, the energy degradation and attendant bremsstrahlung emission of a high-energy electron beam, heating of a flare plasma by the beam, and subsequent cooling by thermal conduction and radiation. To assist in the interpretation of experimental diagnostics, the model also characterizes the radiative behavior of iron ions present in the flare plasma. Electron deposition is described by the Fokker-Planck equation for an initial power-law particle distribution. Results are presented for the bremsstrahlung radiation emitted by the incident beam as it impinges on the disturbed atmosphere. A comparison is made between direct beam heating and thermal-conduction heating of the flare plasma. The radiation emitted by several selected spectral lines of Fe ions is determined as a function of time during and after deposition

Davis, J.↗

Self-Consistent Relativistic Electron Scattering using the Sherlock Scattering Model for X-ray Diagnostics

We present on a new, self-consistent, arbitrary-temperature Romberg integration scheme for modeling electron scattering in materials in a LANL Lagrangian Shock Hydro (LSH) code. Electron beam-target interactions are fundamental to a wide range of scientific and technological applications. When high-energy electron beams hit their target, they may scatter, deposit energy, or ionize the source. These processes govern the behavior and outcomes in nanotechnology manufacturing, electron microscopy, and modern X-ray diagnostics. Simulating these interactions is essential for interpreting experimental results, predicting material responses, and designing efficient tools and experiments. At Los Alamos, this is done using a LSH code, which is a multi-dimension, multi-material, massively parallel, multi-physics code used to simulate applications from asteroid impacts to electron beam interactions. By effectively and efficiently modeling the way that electrons scatter from the beam we can bolster these simulations and more accurately predict experimental outcomes. The model currently implemented in the LSH of interest is based on work by Papp and does not self-consistently preserve momentum in the slightly relativistic regime; here we adopt a model proposed by Braams and Karney and implement a Romberg integration scheme to compute the diffusion tensor. In this paper we will provide background on the Braams-Karney diffusion tensor as well as the Romberg integration scheme we employed to numerically solve for it. We will show that our integration scheme is accurate in solving for the set of scalar potentials used to re-express the diffusion tensor in differential form, and in solving for the diffusion coefficients in the larger LSH code. By using this diffusion tensor rather than the existing Papp one, and numerically integrating it with a Romberg method, we produce much more accurate, self-consistent results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling the Interaction of Laser-Produced Proton Beams with Matter

A major goal of this project is to significantly increase our understanding of isochoric heating of matter using laser produced proton beams, and the associated high energy density (HED) and warm dense matter (WDM) regimes generated. This will benefit research fields such as planetary science, fusion energy, plasma physics, and material science. For example, it will enhance our understanding of WDM properties of iron and silica under conditions encountered in planetary interiors and diagnostic components in fusion devices exposed to high fluxes of energetic plasma ions. The project is motivated by recent experiments that irradiated Si targets with proton beams generated by the 20 TW-laser at the SLAC MEC end-station. The HED/WDM states are probed using the 50 fs hard X-rays available in the 3rd harmonic of the LCLS. As part of this project, results from the phase contrast X-ray imaging, which shows the generation of compression waves that produces rear surface spallation, are compared with results from the 3D multi-physics multi- material code, PISALE, that combines Arbitrary Lagrangian-Eulerian (ALE) hydrodynamics with Adaptive Mesh Refinement (AMR). This comparison required modifications to several physics models in the PISALE (Pacific Island Structured-AMR with ALE) code. An important aspect of this project is the continued training of graduate students in HED physics and in conducting complex multiphysics simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A platform for non-local thermodynamic equilibrium atomic physics research using the buried layer target approach at a kJ level laser facility

Here we present a design and first use of a kJ level laser facility for research of non-local thermodynamic equilibrium atomic physics using the buried layer target method. The target design included a metal layer buried inside a plastic tamper with thicknesses tailored to the expected laser intensities. The target was illuminated from each side by two laser beams with intensities of 0.5–5 × 10 14 W/cm 2 . The advanced diagnostic suite included static and time-resolved imagers and spectrometers with various spectral resolutions. A 3D printed dual elliptically curved spectrometer is presented, and its results are compared to a traditional crystal spectrometer. Experimental results and radiation hydrodynamic simulations demonstrate that the target achieved the desired thermodynamic conditions of n e ≈ 10 21 –10 22 cm -3 and T e ≈ 1–2 keV.

3D printing↗

Spacelab 1 experiments on interactions of an energetic electron beam with neutral gas

An unusual signature of return current and spacecraft charging potential was observed during the Spacelab 1 mission launched on November 28, 1983. The phenomenon occurred during neutral gas releases from the SEPAC (Space Experiments with Particle Accelerators) magnetoplasma-dynamic arcjet (MPD) concurrent with firings of the PICPAB (Phenomena Induced by Charged Particle Beams) electron gun and was recorded by the instruments of the SEPAC diagnostic package (DGP). Data from the langmuir probe, floating probes, neutral gas pressure gauge, and the plasma wave probes are reported. As the dense neutral gas was released, the return current measured by the langmuir probe changed from positive to negative and a positive potential relative to the spacecraft was measured by the floating probe. The anomalous return current is believed to be attributable to secondary electron fluxes escaping from the spacecraft, and the unusual charging situation is attributed to the formation of a double-layer structure between a hot plasma cloud localized to the MPD and the spacecraft. The charging scenario is supported by a computer simulation.

Marshall, J. A.↗

A near-infrared spectroscopic study of the starburst core of M82

Near-IR spectroscopy of the M82 starburst core is presented, including complete J, H, and K band spectra with a resolution of 0.0035-micron for the inner 60 pc of the galaxy. Also, spatial profiles along the starburst ridge are presented for Br-gamma, molecular hydrogen, and forbidden Fe II line fluxes. Emission from shocked molecular hydrogen is detected from the core of M82. The distribution of features across the starburst disk are mapped to study the relationships between spectral diagnostics. The observations are used to test the appropriateness of single-beam, aggregate models for studying the physical conditions in starbursts.

Lester, D. F.↗

Scaling and applied field studies of MPD thrusters with laser diagnostics

The topics are presented in viewgraph form and include the following: self-field magnetoplasmadynamics; 1/4-scale applied-field MPD; scaling of arcs and MPD-arcs; magnetic nozzle studies; advanced diagnostic techniques needed for obtaining particle velocity, temperature, and current distributions in plasma thrusters; nonintrusive laser diagnostics for arcs and MPD-arcs; and schematic of multi-beam interferometer for electron density profile determination.

York, Thomas M.↗

Hybrid Automated Diagnosis of Discrete/Continuous Systems

A recently conceived method of automated diagnosis of a complex electromechanical system affords a complete set of capabilities for hybrid diagnosis in the case in which the state of the electromechanical system is characterized by both continuous and discrete values (as represented by analog and digital signals, respectively). The method is an integration of two complementary diagnostic systems: (1) beacon-based exception analysis for multi-missions (BEAM), which is primarily useful in the continuous domain and easily performs diagnoses in the presence of transients; and (2) Livingstone, which is primarily useful in the discrete domain and is typically restricted to quasi-steady conditions. BEAM has been described in several prior NASA Tech Briefs articles: "Software for Autonomous Diagnosis of Complex Systems" (NPO-20803), Vol. 26, No. 3 (March 2002), page 33; "Beacon-Based Exception Analysis for Multimissions" (NPO-20827), Vol. 26, No. 9 (September 2002), page 32; "Wavelet-Based Real-Time Diagnosis of Complex Systems" (NPO-20830), Vol. 27, No. 1 (January 2003), page 67; and "Integrated Formulation of Beacon-Based Exception Analysis for Multimissions" (NPO-21126), Vol. 27, No. 3 (March 2003), page 74. Briefly, BEAM is a complete data-analysis method, implemented in software, for real-time or off-line detection and characterization of faults. The basic premise of BEAM is to characterize a system from all available observations and train the characterization with respect to normal phases of operation. The observations are primarily continuous in nature. BEAM isolates anomalies by analyzing the deviations from nominal for each phase of operation. Livingstone is a model-based reasoner that uses a model of a system, controller commands, and sensor observations to track the system s state, and detect and diagnose faults. Livingstone models a system within the discrete domain. Therefore, continuous sensor readings, as well as time, must be discretized. To reason about continuous systems, Livingstone uses monitors that discretize the sensor readings using trending and thresholding techniques. In development of the a hybrid method, BEAM results were sent to Livingstone to serve as an independent source of evidence that is in addition to the evidence gathered by Livingstone standard monitors. The figure depicts the flow of data in an early version of a hybrid system dedicated to diagnosing a simulated electromechanical system. In effect, BEAM served as a "smart" monitor for Livingstone. BEAM read the simulation data, processed the data to form observations, and stored the observations in a file. A monitor stub synchronized the events recorded by BEAM with the output of the Livingstone standard monitors according to time tags. This information was fed to a real-time interface, which buffered and fed the information to Livingstone, and requested diagnoses at the appropriate times. In a test, the hybrid system was found to correctly identify a failed component in an electromechanical system for which neither BEAM nor Livingstone alone yielded the correct diagnosis.

Park, Han↗

Millimeter-wave high-wavenumber scattering diagnostic developments on EAST and NSTX-U

A pioneering 4-channel, high-k poloidal, millimeter-wave collective scattering system has been successfully developed for the Experimental Advanced Superconducting Tokamak (EAST). Engineered to explore high-k electron density fluctuations, this innovative system deploys a 270 GHz mm-wave probe beam launched from Port K and directed toward Port P (both ports lie on the midplane and are 110° part), where large aperture optics capture radiation across four simultaneous scattering angles. Tailored to measure density fluctuations with a poloidal wavenumber of up to 20 cm -1 , this high-k scattering system underwent rigorous laboratory testing in 2023, and the installation is currently being carried out on EAST. Its primary purpose lies in scrutinizing ion and electron-scale instabilities, such as the electron temperature gradient (ETG) mode, by furnishing measurements of the k θ (poloidal wavenumber) spectrum. This advancement significantly bolsters the capacity to probe high-k electron density fluctuations within the framework of EAST. Finally, beam tracing and data interpretation modules developed for both EAST and NSTX-U high-k scattering diagnostics are described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Digital twin framework for PIP-II linac: AI-driven multi-scale modeling from ion source to 800 MeV

The PIP-II superconducting linac at Fermilab is designed to deliver multi-megawatt proton beams for neutrino physics and other high-intensity applications. To expedite commissioning and enhance operational reliability, we have developed an EPICS-based data flow framework that seamlessly integrates digital twins (DT) with physical twins (PT). These digital twins comprise high-fidelity beam dynamics models or data-driven surrogate models connected to their physical counterparts through real-time diagnostics and advanced machine-learning algorithms.Central to this framework is Linac_Gen, an accelerated simulation tool that incorporates convolutional neural networks, random forests, and genetic algorithms to provide up to a tenfold speedup in optimizing the accelerator geometry model. An EPICS translator layer ensures interoperability by efficiently mapping lattice parameters across diverse simulation platforms.Our EPICS-based framework supports multiple operational modes—monitoring, passive learning, closed-loop control, and online learning—covering the entire machine lifecycle. By leveraging HPC resources and multi-objective optimization techniques, the digital twin enables adaptive trajectory correction, real-time fault detection, and predictive modeling of beam stability. This comprehensive approach paves the way for robust, high-intensity operation and data-driven accelerator R&D at Fermilab.

Pathak, Abhishek [Fermilab]↗

Implementation of a 1550-nm laser system for beam characterization at the Argonne Wakefield Accelerator

Accurately recording an electron bunch’s longitudinal profile is an important diagnostic for wakefield accelerators employing shaped bunches to increase transformer ratios. Electro-optic sampling of terahertz radiation from the bunch is an attractive approach due to its non-destructive nature. In preparation for future characterization experiments, the Argonne Wakefield Accelerator test facility has recently installed a 1550 nm laser system, including the necessary support systems to synchronize with the photoinjector laser system at 81.25 MHz. We report here on the initial installation and synchronization demonstrations.

Ody, Alexander [Argonne, PHY]↗

Removing Spectral Diagnostics of Galactic and Stellar X-Ray Emission from Charged Exchange Recombination

Our research uses the electron beam ion trap (EBIT) at the Lawrence Livermore National Laboratory to study X-ray emission from the charge exchange (CX) of highly charged ions with neutral gases. The resulting data help to fill a void in existing experimental and theoretical understanding of this atomic physics process, and are needed to explain all or part of the observed X-ray emission from the soft X-ray background, stellar winds, the Galactic Center and Galactic Ridge, supernova ejecta, and photoionized nebulae. Appreciation of the astrophysical relevance of our work continues to grow with the publication of roughly a dozen papers in the past four years describing Chandra and XMM observations of geocoronal and heliospheric CX emission, the temporal variation of such emission and correlation with X-ray emission enhancements observed by ROSAT, the theoretical spatial distribution of that emission, and CX emission around other stars. A similar number of papers were also published during that time describing CX emission from planets and comets. We expect that the launch of ASTRSE2, with its second-generation XRS microcalo- (with 6-eV resolution), will reveal even more clearly the contributions of CX to astrophysical emission. In our EBIT work we collected CX spectra from such ions as H-like and He-like Ne, Ar, and Fe. Our early measurements were made with a high-purity Ge detector, but during the second year we began operation of the first-generation XRS microcalorimeter (a twin of the XRS on ASTRO-E) and greatly improved the resolution of our measurements from roughly 150 eV (FWHM) with the Ge detectors to 10 eV with the XRS. We found that saturation of the XRS counting apparatus, which we described in our proposal as a potential concern, is not a problem for studying CX. During the course of our research, we expanded the number of injection gases permitted by the LLNL safety team, purchased and eventually operated an atomic H source, and clearly demonstrated the feasibility of our longer-range plan. For example, we successfully injected He into EBIT (not a small feat because of the difficulty of maintaining a good vacuum with He and avoiding electrical breakdown) to collect a H-like oxygen CX spectrum. The highest energy CX spectrum recorded with the XRS to date is that of the Ar K-shell emission. These measurements provided the first observation of the relative intensity ratios of resolved He-like singlet and triplet n=2->1 lines. We also carried out measurements of He-like Ne as a function of collision energy (i.e., ion temperature). Significant differences in the resulting x-ray spectra were noted. In all cases, the intensity of high-n H-like Lyman lines is significantly higher than current theoretical CX models predict.

Wargelin, Brad↗

Electron beam fluorescence measurements in the Boeing hypersonic shock tunnel

The Calspan electron beam fluorescence (EBF) measurement system is described along with the results of measurements made in hypersonic flow. Numerous self-emitting metallic species were identified, many of which may be associated with an aging/erosion process within the B30HST. Because there were only 16 tunnel runs, it was only possible to obtain spectral measurements over a limited range of wavelengths and time sampling periods. Many spectral features of the flow remain uninvestigated. Because flow self-emission is important to all optical diagnostic techniques, it is recommended that additional spectral studies by performed. The three electron beam-excited species that were identified are nitrogen, helium, and nitric oxide. The high metallic radiation background interfered with attempts to obtain the time-wise variation of N2 density and He radiation with the optical fiber/PMT channels. In the case of the N2 density measurements the result of interference was increased uncertainty. Unfortunately, the interference caused the time-wise He measurements to fail completely. It is recommended that the electron beam be modulated to provide discrimination against the background radiation in future N2 density measurements. Careful data reduction produced useful measurements of N2 vibrational temperature, even though the high background from metallic species significantly increased measurement uncertainty. Perhaps the recommended additional spectral studies would reveal N2(+) First Negative System band-pair regions having less background. Detection of the He arrival was easily accomplished with the spectrometer/array detector system. Because of this, it is recommended that this means of detecting He arrival be used in the future. With proper calibrations of the system an He number density could be obtained. Although the flow conditions were out of limits for the run in which the NO spectrum was recorded, the usefulness of the NO spectrum for determination of free-stream rotational temperature was demonstrated and should be exploited in future experiments. Indeed, based on the strong NO signals, it is recommended that lower resolution NO spectra be obtained to provide a measure of NO vibrational temperature in the same manner that the N2 temperature was obtained.

Price, Linwood L.↗

Diagnostic Systems in the Muon $g-2$ experiment at Fermilab

The muon anomalous magnetic moment, $a_\mu=\frac{g-2}{2}$, is a low-energy observable which can be both measured and computed to high precision, making it a sensitive test of the Standard Model and a probe for new physics. This anomaly was measured with a precision of $0.20$~parts per million (ppm) by the Fermilab's Muon g-2 (E989) experiment. The final goal of the E989 experiment is to reach a precision of $0.14$~ppm. The experiment is based on the measurement of the muon spin anomalous precession frequency, $\omega_a$, based on the arrival time distribution of high-energy decay positrons observed by 24 electromagnetic calorimeters, placed around the inner circumference of a $14$~m diameter storage ring, and on the precise knowledge of the storage ring magnetic field and of the beam time and space distribution. Achieving this level of precision requires strict control over systematics, which is ensured through several diagnostic devices. At the accelerator level, these devices monitor the quality of the injected beam (e.g., verifying that it has the correct momentum), while at the detector level, they track both the magnetic field and the gain of the calorimeters. In this work the devices and techniques used by the E989 experiment will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Post-DTL Beam Delivery

Ensuring that the beam delivered from the upgraded Front-End (FE) meets the Key Performance Parameters (KPPs) at each user facility is critical to the success of the LANSCE Accelerator Modernization Project (LAMP). For a high-intensity, multi-user facility like LANSCE, compliance with beam loss and radiation thresholds is as important as the charge delivered to each target. While early LAMPF/LANSCE operations relied on iterative tuning to minimize losses from beam halo and tail particles, the new FE may introduce different beam distributions and loss modes—making predictive modeling essential. To manage this, the F2E (Front-End to End) effort is developing detailed particle-tracking models that reflect realistic beamline conditions, including halo formation and expected diagnostic readings. These "snapshot" simulations aim to benchmark live machine performance at a given moment. This will help quantify how beam quality from the new FE will propagate downstream through the facility. Only by validating these models can we confidently assess and mitigate the potential impacts of the LAMP FE on beam delivery. Post-DTL, the beam splits to serve five major user facilities. Historically, low-energy beam transport has been modeled using TRACE, and higher-energy sections with TRANSPORT. These have now been unified into MAD-X format and validated with codes such as Elegant, pyOrbit, XSuite, Impact-Z, and HPSim. The primary focus now is on accurate modeling of full particle distributions (including beam halo) as they traverse the accelerator and beamlines to each experimental station. All models are at various stages of validation with empirical data.

43 PARTICLE ACCELERATORS↗

POD Model Reconstruction for Gray-Box Fault Detection

Proper orthogonal decomposition (POD) is the mathematical basis of a method of constructing low-order mathematical models for the "gray-box" fault-detection algorithm that is a component of a diagnostic system known as beacon-based exception analysis for multi-missions (BEAM). POD has been successfully applied in reducing computational complexity by generating simple models that can be used for control and simulation for complex systems such as fluid flows. In the present application to BEAM, POD brings the same benefits to automated diagnosis. BEAM is a method of real-time or offline, automated diagnosis of a complex dynamic system.The gray-box approach makes it possible to utilize incomplete or approximate knowledge of the dynamics of the system that one seeks to diagnose. In the gray-box approach, a deterministic model of the system is used to filter a time series of system sensor data to remove the deterministic components of the time series from further examination. What is left after the filtering operation is a time series of residual quantities that represent the unknown (or at least unmodeled) aspects of the behavior of the system. Stochastic modeling techniques are then applied to the residual time series. The procedure for detecting abnormal behavior of the system then becomes one of looking for statistical differences between the residual time series and the predictions of the stochastic model.

Park, Han↗

Particulate Emission and Optical Measurements in n-Heptane Low-Swirl Non-Premixed Flames at Elevated Pressures

A series of ground combustion tests conducted at elevated pressures demonstrates in-chamber optical measurements of soot emissions, combined with conventional gaseous and particle emissions sampling techniques. Utilizing a micro-radial-entry counter-swirl (MRX) burner, we successfully stabilized an n-heptane low-swirl, non-premixed spray flame across a wide range of equivalence ratios at pressures reaching 250 psia. Our optical diagnostics feature a temporally gated diffused-backlight illumination extinction imaging (DBI-EI) system, equipped with a 470-nm strobe high-intensity LED array as the illumination source, along with a line-of-sight telecentric camera. By accessing the flame tube, the pulsed DBI-EI provides illuminating optical extinction images, enabling experimental estimation of soot volume fractions within the reaction zone. This imaging technique will allow for real-time observation of soot formation dynamics occurring above the air-blast fuel injector. To further enhance our analysis, we employed simultaneous gaseous and particulate extractive diagnostics, interpreting in-flame particulate information through CO2 sampling, exhaust particle sizing, and particle counting. The processed dataset reveals a promising application of DBI-EI for propulsion emission analysis in high-pressure environments, where optical beam-steering effects can significantly impact results. This report is essential to bridging the divide between in-flame optical diagnostics and exhaust extractive measurements. By achieving an understanding of non-premixed combustion emission characteristics, we attempt to provide invaluable data for computer code validation, advancing the field of combustion research and supporting the development of cleaner, more efficient engines.

high-pressure flame↗