Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building Energy Modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

ResStock Measure Documentation: Advanced Air Sealing With Drill-and-Fill Wall Insulation

This report is part of a series describing different ResStock(TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Air Sealing With Drill-and-Fill Wall Insulation" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spokane Eco-District Campus Performance Under Alternative Electricity Rates: Benefits for virtual power plant participants and suppliers

Here, the respective benefits for virtual power plant participants and suppliers are revealed and compared under alternative electricity rate structures, including conventional large commercial electricity rates, large commercial electricity rates with special rates for demand-side generation, and dynamic hourly transactive prices. These three scenarios were explored using the capabilities of the Eco-District campus, a virtual power plant in Spokane, Washington, that is supplied electricity by Avista Utilities. The Eco-District Campus was modeled to host solar power generation, battery energy storage, and thermal energy resources that must be coordinated with building heating and cooling needs. First, the electricity supplier’s costs for energy, infrastructure, and energy losses were modeled. Then, the virtual power plant’s performance was modeled while presuming that its manager would minimize its costs under its electricity rate structure. The demand charges of conventional commercial electricity rates managed monthly peak, as would be expected, but hourly dynamic transactive pricing resulted in a striking alignment between the costs incurred by the supplier and the virtual power plant’s energy costs.

Electricity rates↗

2024 Status Report - Fiberboard Properties and Degradation Rates for Storage of 9975 Shipping Package in KAC

Fiberboard assemblies in the 9975 package were identified as susceptible to aging and degradation under long-term storage conditions. Thermal, mechanical, and physical properties have been measured on fiberboard samples aging for up to 19 years at accelerated conditions. The aging environments include elevated temperature up to 250 ºF (the maximum allowed service temperature for fiberboard in 9975 packages) and elevated humidity. Accelerated aging results have been analyzed and used to build aging models. Correlations relating several properties (thermal conductivity, energy absorption, weight, dimensions, and density) to their rate of change in potential storage environments have been developed. Combined with an estimate of the actual conditions the fiberboard experiences in K-Area Complex (KAC), these models allow development of service life predictions.

36 MATERIALS SCIENCE↗

2025 Status Report - Fiberboard Properties and Degradation Rates for Storage of 9975 Shipping Package in KAC

Fiberboard assemblies in the 9975 package were identified as susceptible to aging and degradation under long-term storage conditions. Thermal, mechanical, and physical properties have been measured on fiberboard samples aging for up to 20 years at accelerated conditions. The aging environments include elevated temperature up to 250 ºF (the maximum allowed service temperature for fiberboard in 9975 packages) and elevated humidity. Accelerated aging results have been analyzed and used to build aging models. Correlations relating several properties (thermal conductivity, energy absorption, weight, dimensions, and density) to their rate of change in potential storage environments have been developed. Combined with an estimate of the actual conditions the fiberboard experiences in K-Area Complex (KAC), these models allow development of service life predictions. KAC completed calculations that supported extending the service life of 9975 packages with 3013 containers in storage from 20 years to 40 years. These calculations addressed the potential for degraded fiberboard properties following 40 years in storage using degradation models. The 40 year storage evaluations assumed the degradation rates from initial values for density, dimensional, and thermal properties were 0.5% per year (i.e., after 40 years, the density, dimensional, and thermal properties of fiberboard were 80% of its initial values). The updated degradation models developed in this report were compared to the assumptions in those calculations, and the current results for fiberboard dimensions, density, axial and radial thermal conductivities, and energy absorption remain consistent with those calculations. Additional data will continue to be collected to permit future refinements to the models and assumptions. Some of the predicted degradation rates presented in this report are purposely high to accelerate aging. These rates relate to environments that do not exist within KAC or are postulated to only occur as upset conditions that are unlikely to persist for an extended period. For a typical package stored in KAC with approximately 10-12 watts internal heat load or less, and ambient temperatures below 90 ºF, the fiberboard assemblies experience storage conditions less severe than any of the aging environments (i.e., under 125 °F) used in this study. Fiberboard in conforming packages with lower internal heat loads should experience little or no degradation and is expected to provide a service life beyond the currently approved 40 year storage period. Packages with higher internal heat loads may not continue to perform their required safety functions beyond 40 years. Ultimately, service life will be determined by the cumulative effect of degradation from all the conditions these packages might encounter. The results and model predictions presented in this report are applicable to 9975 packages with cane or softwood fiberboard overpack assemblies. These degradation models do not address the effects of nonconforming conditions such as the presence of excess moisture and mold or beetle infestations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DEMO-FTES: Development, Monitoring, and Control of Fracture Thermal Energy Storage in Crystalline Rock Formations (CRADA Final Report)

The DEMO-FTES project investigated the feasibility of Fracture Thermal Energy Storage (FTES) as a seasonal energy storage solution in crystalline rock formations. FTES leverages hydraulically induced fractures to exchange heat between circulating fluids and the surrounding rock mass, enabling long-term thermal energy retention due to the high specific heat and low thermal conductivity of rock. This approach has the potential to reduce heating and cooling energy demands and enhance building energy resilience. The project combined dimensional analysis, numerical modeling, laboratory experiments, and meso-scale field tests to evaluate FTES performance and advance its technology readiness level from 3 to 5. Scaling analysis identified key dimensionless parameters governing heat transfer and fluid flow, ensuring laboratory and field tests were representative of larger-scale systems. Numerical simulations using TOUGH and iTOUGH2 frameworks supported experiment design and interpretation, modeling fracture geometry, thermal-hydraulic behavior, and thermo-mechanical coupling. Laboratory tests at EPFL involved creating single and multiple fractures in 25 cm cubic samples of Gabbro and Granite under true triaxial stress.

25 ENERGY STORAGE↗

LIGHT-bgcArgo-1.0: using synthetic float capabilities in E3SMv2 to assess spatiotemporal variability in ocean physics and biogeochemistry

Since their advent over 2 decades ago, autonomous Argo floats have revolutionized the field of oceanography, and, more recently, the addition of biogeochemical and biological sensors to these floats has greatly improved our understanding of carbon, nutrient, and oxygen cycling in the ocean. While Argo floats offer unprecedented horizontal, vertical, and temporal coverage of the global ocean, uncertainties remain about whether Argo sampling frequency and density capture the true spatiotemporal variability in physical, biogeochemical, and biological properties. As the true distributions of, e.g., temperature or oxygen are unknown, these uncertainties remain difficult to address with Argo floats alone. Numerical models with synthetic observing systems offer one potential avenue to address these uncertainties. Here, we implement synthetic biogeochemical Argo floats into the Energy Exascale Earth System Model version 2 (E3SMv2), which build on the Lagrangian In Situ Global High-Performance Particle Tracking (LIGHT) module in E3SMv2 (E3SMv2-LIGHT-bgcArgo-1.0). Since the synthetic floats sample the model fields at model run time, the end user defines the sampling protocol ahead of any model simulation, including the number and distribution of synthetic floats to be deployed, their sampling frequency, and the prognostic or diagnostic model fields to be sampled. Using a 6-year proof-of-concept simulation, we illustrate the utility of the synthetic floats in different case studies. In particular, we quantify the impact of (i) sampling density on the float-derived detection of deep-ocean change in temperature or oxygen and on float-derived estimates of phytoplankton phenology, (ii) sampling frequency and sea-ice cover on float trajectory lengths and hence float-derived estimates of current velocities, and (iii) short-term variability in ecosystem stressors on estimates of their seasonal variability.

54 ENVIRONMENTAL SCIENCES↗

Residential Building Stock Characterization in Palm Beach County, Florida

This building stock characterizations is intended to help Palm Beach County (PBC) Office of Resilience (OOR) and municipalities composing the Municipal Resilience Partnership prioritize building energy efficiency investments to reduce energy costs and increase resilience for the county's most vulnerable residents. The analysis utilizes NREL’s ResStock model to characterize PBC’s residential building stock, including building type, renter/owner status, size (square footage), age of buildings (vintage), HVAC system types, and, for multi-family buildings, number of units. Building energy efficiency, weatherization, and electrification upgrade packages were assessed for approximate cost, customer bill-savings, and emissions reductions potential and findings will help guide OOR financial assistance program design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Attic Floor Insulation

This report is part of a series describing different ResStock measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Attic Floor Insulation" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

COGIHTO: Comprehensive Geothermal Integrated HVAC Retrofits in Disadvantaged Communities

Geothermal heating and cooling (GHC) systems offer one of the most efficient approaches to provide space conditioning and water heating in buildings. Due to the relatively stable temperature of the ground year-round, these systems can provide an efficient solution to decarbonize heating systems. Yet this technology has faced limited market adoption due to its high first cost. This project seeks to address this barrier by designing a community GHC system at a public housing development in New York, taking advantage of load diversity (in terms of the timing and amount of heating / cooling used per person) that a larger community offers to reduce the size and thus first cost of a GHC system. Project success would result in societal benefit from reduced energy and fossil fuel use, reduced local emissions, and improved comfort, which would positively impact the health and well-being this community. This report presents the findings from Phase 1 project supported by the Department of Energy’s Geothermal Technologies Office and includes the technical design of a GHC at a public housing development in New York. To support the success of a potential deployment of a GHC system, the team conducted community engagement and prepared an assessment of the local workforce needs. The project team, led by EPRI, considered a subset of NYCHA housing developments that were previously identified by NYCHA as suitable for GHC retrofits. This report presents the site selection criteria the team developed and the overall score assigned to each of the eight developments considered. One site was selected for focus of the technical design: Stapleton Houses in Staten Island, a mid-size development with roughly 700 apartments across 6 buildings. The site has an existing hot water hydronic loop served by natural gas boilers for space heating and water heating. The technical design partner assessed baseline energy consumption at the site and established thermal models of the apartment buildings to assist in the design. The team considered several GHC system configurations and selected a hybrid geothermal design fed from water-source heat pumps with auxiliary gas boilers in a central plant. This design best leveraged the existing site configuration and minimized costs due to additional electrical infrastructure upgrades. The report also details the feedback received from community engagement efforts and the findings from the workforce needs assessment and workforce transition plan. Members of the site maintenance staff and the resident advisory council were interviewed for their input and feedback about both the site’s existing heating/cooling infrastructure and how a construction project would impact resident life. This feedback was taken into consideration when completing the geothermal system design. Research was conducted into existing workforce development opportunities available to NYCHA residents. A workforce development plan was established using information from NYCHA’s resident economic empowerment and sustainability group, along with training material and curriculum from the International Ground Source Heat Pump Association (IGSHPA).

15 GEOTHERMAL ENERGY↗

ResStock Measure Documentation: Propane Furnace 95% AFUE and Fuel Oil Furnace 88% AFUE

This report is part of a series describing different ResStock (TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Propane Fuel 95% AFUE and Fuel Oil Furnace 88% AFUE" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Reference Space Heating and Air Conditioning Upgrade Circa 2025

This report is part of a series describing different ResStock (TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Reference Space Heating and Air Conditioning Upgrade Circa 2025" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a Sizing and Modeling Platform for District Energy Systems with Geothermal Heat Pumps

Existing tools for community or urban scale energy system modeling and simulation are often limited in their capabilities and require expert-level modeling proficiency to develop system models. To fill this gap, this paper proposes an integrated sizing and modeling platform for district energy systems with geothermal heat pumps. The proposed platform takes in geometric and non-geometric user inputs related to the buildings, borefield, and district energy loop. Then, the platform sizes the geothermal heat exchanger, generates a corresponding district energy system model, and runs an annual simulation automatically. We validated the simulation performance of the borefield in our tool against EnergyPlus. A case study is provided in this paper to demonstrate the workflow and simulation result plausibility of the proposed platform.

decarbonization↗

Integrating Energy-Efficient Computing with Computational Research to Accelerate Energy Technology

NREL's computational sciences center hosts the largest high performance computing (HPC) capabilities dedicated to energy research while functioning as a living laboratory for energy-efficient computing. NREL's HPC capabilities support the research needs of the Department of Energy's Office of Energy Efficiency and Renewable Energy (EERE). In ten years of operation, HPC use in EERE-sponsored research has grown by a factor of 30, including work in electricity generation, energy efficiency, transportation, and energy system modeling. This paper analyzes this research portfolio, providing examples of individual use cases. The paper documents NREL's history of operating one of the world's most energy-efficient data centers while examining pathways to reduce economic and environmental impact beyond reduction of Power Usage Efficiency (PUE). This paper concludes by examining the unique opportunities created for accelerating improvements in data center efficiency created by combining an HPC system dedicated to energy research and a research program in energy-efficient computing.

97 MATHEMATICS AND COMPUTING↗

ResStock Measure Documentation: Natural Gas Furnace 95% AFUE

This report is part of a series describing different ResStock (TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Natural Gas Furnace 95% AFUE" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coupled Aerodynamic and Hydrodynamic Hybrid Simulation of Floating Offshore Wind Turbines

The development and innovation of floating offshore wind energy in the U.S. requires detailed high-fidelity observations and measurements of turbine and platform loading due to wind, waves, and currents. However, full-scale and quasi-full-scale experiments require significant financial and temporal investments for construction, experimental testing, and long-term field campaigns. To support the commercial advancement of the offshore wind energy industry, specialized wind tunnel and wave basin experimental facilities are critical to be able to test FOWT designs at small scale under controlled conditions prior to full-scale deployment. Oregon State University (OSU) is internationally known as a leader in water and energy research, development, and testing. The O.H. Hinsdale Wave Research Laboratory (HWRL) and the Wallace Energy Systems and Renewables Facility (WESRF) at OSU have extensive experience building, modeling, monitoring, controlling, and actuating scaled systems. Experiments on wave-structure interaction have been performed at the HWRL since its establishment in 1972. Studies have included the interaction of waves with coastal structures (breakwaters, seawalls, buildings, cylinders, bridges, fixed foundations of offshore wind turbines, etc.) and with floating structures (e.g., wave energy converters, maneuvering of vessels, etc.). Hinsdale is actively used by marine energy technology developers, both for private testing and OSU-collaborative research projects. However, despite the availability of several large-scale facilities for hydrodynamic testing (at OSU and elsewhere in the U.S.), existing experimental laboratories are generally limited in their ability to accurately generate combined wind and wave conditions. The simulation of both wind and waves in experimental testing is complicated due to a number of constraints, including: [i] incompatible similitude laws governing the wind and waves for scaled experiments, [ii] producing accurate wind over a large enough control volume via fans, and [iii] generating wind that reasonably represents the atmospheric boundary layer in existing wave basins/flumes. Hence, physical test data providing insight into the simultaneous wave- and wind-structure response of floating offshore wind components can be difficult to generate. Given the aforementioned challenges in classic hydrodynamic experiments, the motivation of this project is to establish a real-time hybrid simulation (RTHS) approach that can apply aero- and hydro-dynamic loading by augmenting wave-only experimental facilities with virtual aerodynamic forces through numerical models representing the remaining dynamic forces. RTHS is a physical-numerical approach that partitions a prototype system into physical and numerical sub-assemblies that interact with each other through actuators and sensors in real time. In coupling physical and numerical models, the hybrid simulation approach applied herein is ideal for problems with: (1) structures subjected to different scaling laws, such as floating offshore wind turbines subjected to combined aero/hydro-dynamic loading, (2) structures that are too large or complex to be tested entirely in a laboratory setting, such as deep-water mooring applications, and (3) component testing, where the behavior of a portion of the assembly is uncertain but still interacts with other portions of the structure, such as testing the fatigue life of turbine blades. Few U.S. experimental facilities are able to test simultaneous aero- and hydro-dynamic loading and none can accurately produce aero/hydro-dynamic response on scaled FOWT models due to conflicting similitude laws between the wind (commonly Reynolds) and the waves (commonly Froude). To aid in accelerating the development of the U.S. floating offshore industry, there is a significant need to develop a flexible, modular framework that can expand the capacities of existing wave-only laboratories. The project goal is to demonstrate a hydrodynamic real-time hybrid simulation (hydro-RTHS) framework that couples numerical wind and physical waves acting on a FOWT, thus representing simultaneous aero/hydro-dynamic loading. The FOWT is partitioned into a full-scale numerical sub-assembly associated with the aerodynamics and a model-scale physical sub-assembly associated with the hydrodynamics. The numerical-physical partition associated with hydro-RTHS mitigates scaling constraints by supplying different scaling laws to the physical and numerical sub-assemblies. Herein, length, force, and time are scaled and exchanged between the sub-assemblies using Froude scaling to represent the open-channel flow in the physical sub-assembly. Other similitude laws could also be utilized depending on the problem definition. It is envisioned that the ability to model FOWTs under waves and wind, with mitigation of similitude distortions, would result in reduced development costs (currently, FOWT concept development is performed with full-size pro- totypes at enormous expense and risk) and increase the reliability of the FOWT industry (since extreme wave and wind conditions and contingency events can be tested safely in a controlled environment).

16 TIDAL AND WAVE POWER↗

Comparative Analysis of HEATNETS for Geothermal Network Performance

Thermal energy networks (TENs), also known as 5th generation district energy systems, or more specifically geothermal networks when exchanging heat with geothermal boreholes, are an important technology for decarbonization. In these networks an ambient loop connects buildings and thermal sources, such as a borehole field, to exchange energy and maintain a desired loop temperature. Water-source heat pumps are used at the buildings to connect to the ambient or thermal loop to meet to the building heating and cooling loads and maintain comfort. A semi-transient, reduced-order technical model and techno-economic model, called HEATNETS, has been developed at NREL that captures the flow of energy around a TEN. In this work, a comparison of the HEATNETS technical model and a well-known coding platform used for modeling geothermal networks, TRNSYS, has been completed for a proposed geothermal network as a verification and validation process. Hourly data provided from the TRNSYS simulation included building loads, pumping power, heat pump power, temperature entering and leaving the borehole field, and mass flow rates. The hourly borehole temperatures were used to create a linear regression model utilized in HEATNETS to estimate the borehole field heat exchange. The building loads and mass flow rates were direct inputs to HEATNETS while the pumping power, heat pump power, borehole temperatures, and coefficients of performance were all simulated and calculated by HEATNETS, allowing for direct comparison of the thermal energy transfer HEATNETS considers the full process from design inputs to economic outputs and can provide modeling options for high-level initial system design and operational optimization. This study focuses on a validation of HEATNETS using results from TRNSYS. HEATNETS is not intended to replace other modeling tools, but this work demonstrates, via a comparison with an industry standard code, that HEATNETS can be a unique, high-level and rapid modeling tool for estimating the performance of a full geothermal network system.

15 GEOTHERMAL ENERGY↗

Comparative Analysis of HEATNETS for Geothermal Network Performance: Preprint

Thermal energy networks (TENs), also known as 5th generation district energy systems, or more specifically geothermal networks when exchanging heat with geothermal boreholes, are an important technology for decarbonization. In these networks an ambient loop connects buildings and thermal sources, such as a borehole field, to exchange energy and maintain a desired loop temperature. Water-source heat pumps are used at the buildings to connect to the ambient or thermal loop to meet to the building heating and cooling loads and maintain comfort. A semi-transient, reduced-order technical model and techno-economic model, called HEATNETS, has been developed at NREL that captures the flow of energy around a TEN. In this work, a comparison of the HEATNETS technical model and a well-known coding platform used for modeling geothermal networks, TRNSYS, has been completed for a proposed geothermal network as a verification process. Hourly data provided from the TRNSYS simulation included building loads, pumping power, heat pump power, temperature entering and leaving the borehole field, and mass flow rates. The hourly borehole temperatures were used to create a linear regression model utilized in HEATNETS to estimate the borehole field heat exchange. The building loads and mass flow rates were direct inputs to HEATNETS while the pumping power, heat pump power, borehole temperatures, and coefficients of performance were all simulated and calculated by HEATNETS, allowing for direct comparison of the thermal energy transfer, rather than also comparing control systems responses. HEATNETS considers the full process from design inputs to economic outputs and can provide modeling options for high-level initial system design and operational optimization. This study shows that HEATNETS, while not intended to replace other modeling tools, can be a unique modeling tool for the performance of a full geothermal network system.

15 GEOTHERMAL ENERGY↗

Mitigating urban climate-energy feedback with citywide building-integrated photovoltaics implementation

Urban heat islands (UHIs) intensify cooling demands, whose waste heat further exacerbates UHI, creating a self-reinforcing feedback loop. Building-integrated photovoltaics (BIPV) can break this cycle by generating electricity and altering urban climate-energy interactions, yet its net impact remains unresolved. Using a cross-scale modeling framework for 118,521 buildings in Hong Kong, we demonstrate that BIPV glazing reduces cooling demand through improved insulation and lower solar heat gain, while inducing diurnal thermal asymmetry of daytime warming (up to +1.9°C) and nighttime cooling (up to −2.5°C). This microclimate regulation indirectly contributes to a 0.6% reduction in citywide building energy use. Cumulative savings from electricity generation and reduced energy use reach 4.7% (2,060.2 GWh) and 10.1% (4,401.3 GWh) under low- and high-coverage deployment, respectively, with building-level savings of −20.1% ± 11.7% (mean ± SD) at high coverage. We establish BIPV as a configurable climate-energy regulator that enables net-zero, heat-resilient planning and quantifies deployment trade-offs in cooling-dominated cities worldwide.

Building-integrated photovoltaics (BIPV)↗