Evaluating Thermostats’ Deadbands Using HVAC Hardware-In-the-Loop Experiment for Advanced Control Strategies

Thermostats play a crucial role in energy consumption, user control, and occupant comfort by serving as the interface between the heating, ventilation, and air conditioning (HVAC) system and the building's occupants. The deadband, also referred to as temperature differential, is defined as the temperature difference between the desired setpoint and upper threshold or lower threshold for the HVAC equipment to turn on or off. It is a key factor influencing energy efficiency and user satisfaction. This paper presents a comparative analysis of the deadbands of five different thermostats, tested with a residential heat pump, aiming to identify variations in their deadband settings and implications for energy usage and management. The experimental study was conducted using a HVAC hardware-in-the-loop (HIL) system that allows thermostats to be connected with physical HVAC equipment, driven by conditions in a simulated residential building. The study explores the trade-offs between energy efficiency and occupant comfort and highlights how different thermostats cycle differently based on their deadband settings. The findings offer valuable insights into how thermostat deadband affects comfort and energy use, as well as the cycling frequency of a heat pump.

Ramaraj, Sugirdhalakshmi [National Renewable Energ↗

Simulation-based assessment of ASHRAE Guideline 36, considering energy performance, indoor air quality, and control stability

This study assesses American Society of Heating, Refrigerating and Air-Conditioning Engineers Guideline 36 (G36) with a typical medium office building. Specifically, this study employed a Modelica model of a variable air volume (VAV) system that serves this building, which includes components for representing indoor virus transmission and filtration. It then implemented the G36 control sequences for both water-side and air-side equipment in Python. After that, this study conducted the assessment by co-simulating G36 and the Modelica model using the Building Operations Testing Framework. Unlike existing works, this work has three unique features: (1) It considers the interactions between control sequences for water-side and air-side equipment of the studied VAV system. (2) It assesses the performance of G36 from the perspective of IAQ. (3) It examines the short-term behaviors of the studied building under G36 to understand the control stability. This assessment confirms significant energy savings from G36, largely because of the interaction between supply air temperature and hot water controls. It also reveals a trade-off between the ability to slow the spread of virus and the energy performance via demand controlled ventilation. Lastly, it emphasizes the necessity of tuning local feedback control when implementing G36.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Implementation of ASHRAE Guideline 36 Control Logic into Oak Ridge National Laboratory (ORNL)’s Flexible Research Platform (FRP)

This report presents the initial field test procedure and results for ASHRAE Guideline 36 control logic. The US Department of Energy’s Oak Ridge National Laboratory’s (ORNL’s) two-story Flexible Research Platform (FRP-2) was selected as a test building. The rooftop unit (RTU) system serves as the building’s primary cooling system, and each variable air volume (VAV) box with an electric reheat coil serves as the building’s heating system along with RTU gas furnace. In this study, the control for the RTU and VAV box adopted the practical control sequences from ASHRAE Guideline 36-2018: High-Performance Sequences of Operation. Each story of the FRP-2 building has 5 office zones (thermal zones), for a total of 10 zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modulating thermal load through lightweight residential building walls using thermal energy storage and controlled precooling strategy

Precooling is a recognized technique for reducing cooling energy in buildings during peak hours by shifting load to off-peak hours. This technique is particularly effective in buildings with high thermal mass, because of their large thermal energy storage capacity, and in commercial buildings due to their variable electricity pricing based on time-of-use rates. Precooling in residential buildings has been a matter of limited interest in the past because of their low thermal mass and typically uniform electricity pricing rate. While previous studies on precooling primarily focused on cost savings, an important aspect of precooling is the thermal load modulation, which could be very effective in managing peak demand in lightweight residential buildings integrated with thermal energy storage systems. In this study, we examine different precooling strategies to manage the heat gains in lightweight building walls integrated with phase-change materials. We create nine different precooling profiles by controlling the interior temperature, and then evaluate the influence of the precooling profiles on four key building energy performance parameters: total heat gain, peak heat gain, maximum heat gain during peak hours, and time at which peak occurs. To thoroughly understand the fundamental physics, we first consider hypothetical climates and obtain the optimal precooling strategy required to achieve maximum peak shedding and shifting while minimizing the total heat gains. We then extend the model to Baltimore, Maryland, and estimate the benefits of the optimized precooling strategy under real conditions. The optimal precooling strategy proposed in this study can shift the peak heat gain by up to 14 hours, thereby reducing the heat gain during peak period by up to 95%, at the expense of a 23% increase in the total heat gains.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Demonstration of Power over Ethernet (PoE) Technologies in Commercial and Institutional Buildings

Power over Ethernet (PoE) technologies are currently ubiquitous in offices in the form of phones, access points, and IP security cameras. They are systems that are familiar to and managed by on-site IT staff. As low voltage DC-power capabilities have increased with the advancement of IT network switches within offices, PoE devices are now being integrated across additional building systems, including lighting, computers, and HVAC controls. The connection of PoE devices to network switches offers the opportunity for energy monitoring and management to be performed through IT network management software. Data and results from technology validations of PoE equipment remain very limited. This lack of information hinders expansion of PoE as an energy management strategy as its benefits and challenges have been insufficiently quantified in real-world scenarios. This final report presents the findings of a DOE/State of Minnesota-funded project that demonstrated and assessed the energy and non-energy benefits of Power over Ethernet (PoE) technologies at six sites: two offices, three schools, and a hotel. The goals of the demonstrations were to: (1) assess the receptiveness of commercial and institutional markets to these new technologies, (2) demonstrate the feasibility of PoE technologies within standard design/construction practices and commercial codes, (3) assess the energy and cost savings opportunities of these technologies, (4) provide energy management opportunities where not typically available, and (5) formulate approaches to spur adoption of these technologies in the marketplace.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Alfalfa Virtual Building Service: Software Engineering Best Practices Applied to Runtime Interaction with Building Energy Models

Buildings are active participants in increasingly complex energy systems. Building Energy Modeling (BEM) has a key role to play in planning and de-risking an equitable energy transition, with BEM-backed "virtual buildings" critical path for diverse applications that include workforce training tools, Hardware-in-the-Loop (HIL) experimentation to study equipment performance under a range of conditions, Control-Hardware-in-the-Loop (CHIL) experimentation to de-risk commercial control implementations at equipment through grid orchestration levels, and integration of dynamic load profiles into grid modeling tools for energy system experimentation at the urban scale. Modeling requirements vary across these applications, but many software engineering tasks do not. The Alfalfa Virtual Building Service (AVBS, see https://github.com/NREL/alfalfa/wiki) is an open-source web service that solves these common tasks robustly in one place, providing a foundational platform for power users to bootstrap their own applications. AVBS abstracts the specifics of runtime interaction with OpenStudio, Modelica, and Spawn of EnergyPlus models behind a unified REST API. Additionally, AVBS provides resources for cloud deployment and scaling to 100s of parallel simulations, a growing library of modular Operational Technology (OT) integrations for emulation of real-world interfaces, and scripts to automate the population of communities of virtual buildings from URBANopt, ResStock and ComStock.

building automation↗

Integration of Thermoelectric Modules to Vapor Compression Systems

This paper describes the technology of a thermoelectric (TE) integrated heat pump. It uses a TE heat pump to subcool the refrigerant liquid before entering the evaporator to enlarge the evaporating capacity; and elevate the heat in the refrigerant flow to a supplemental heating coil and discharge the capacity to the indoor air flow. Using the DOE/ORNL Heat Pump Design Model, four system configurations were modelled on a baseline two-speed heat pump, the baseline heat pump with adding a supplemental coil, the TE integrated heat pump having one stage TE heating to control a 20R liquid refrigerant temperature drop; and having two stages TE heating to control up to 40R temperature drop. The system models were used to produce performance curves for EnergyPlus building energy simulations. We selected template residential buildings, poorly insulated: pre-1990 buildings, and well-insulated: IECC2021 buildings; in five cold climate zones: 5A, 5B, 6A, 6B, 7. The building energy simulations demonstrated energy saving potentials, utility cost reductions and estimated payback periods.

Shen, Bo↗

Field Testing of a Hierarchical Model-Free Transactive Control Strategy in a Residential House

Demand response plays an important role in addressing the uncertain, intermittent, and variable nature of renewable energy sources. However, to be effective, it requires a significant amount of demand load flexibility, in which buildings are important flexible assets for electricity systems. In this regard, many transactive control tools have been developed to harness this demand flexibility. Yet, such tools are mostly simulation-based or deal with a single load, which may not be sufficient to demonstrate their effectiveness. Towards this end, this paper presents a field implementation and testing of a hierarchical model-free transactive control strategy using residential building thermostatically controlled loads. The transactive control implementation incorporates elements of virtual battery, game theory, and model-free control mechanisms. Experimental field-testing results are provided to demonstrate the effectiveness of the proposed transactive control strategy.

Olama, Mohammed M.↗

Smart Ventilation Controls Boost Energy Efficiency and Indoor Air Quality

The average American household spends more than $2,200 a year on energy, and heating, ventilating, and air conditioning (HVAC) costs comprise nearly half of the bill. This is one reason why home builders focus on tightening building envelopes to save energy. Yet, limiting the potential for air exchange can negatively impact indoor air quality (IAQ). When outdoor conditions are most extreme during occupied periods, there may be comfort implications from continuing high levels of ventilation during associated weather events. This is true even with heat recovery. To mitigate risks, the Florida Solar Energy Center developed and tested approaches for “smart” ventilation system controls that enable more reliable design, installation, and operation to achieve desired IAQ while also minimizing energy and comfort impacts.

Building America↗

Behind the Meter Storage for Electric Vehicle Charging, Electrochemical and Thermal Energy Storage, and Solar Photovoltaic

In response to the potentially large and irregular demand from EVs, along with changing load profiles from buildings with on-site generation, utilities are evaluating multiple options for managing dynamic loads, including time-of-use pricing, demand charges, battery storage, and curtailment of variable generation. Buildings, as well as commercial, public, and workplace EV charging operations, can use a combination of electrochemical battery storage and thermal energy storage coupled with on-site generation to manage energy costs as well as provide resiliency and reliability for EV charging and building energy loads. We are completing a behind the meter storage analysis that focuses on determining the optimal system designs and energy flows for thermal and electrochemical behind the meter storage with on-site solar photovoltaic (PV) generation enabling electric vehicle charging in various climates, building types, and utility rate structures. In completing this analysis, we have developed a tool that combines existing battery models via the System Advisor Model (SAM) and building modeling software via EnergyPlus into a single interface. This tool allows us to simulate a building with a detailed battery model to properly size the battery, thermal energy storage, and solar PV systems to maximize profit for the system owner. This also allows us to assess how the battery degrades under various supervisory control dispatch algorithms to control charging/discharging; we can also see how thermal energy storage is created and used to complement the battery to reduce thermal loads in the building. With this project, we can analyze new batteries that are designed specifically for energy storage, rather than designed to be extremely energy dense for electric vehicle applications, using battery lifetime models from other national labs and the existing SAM battery model, which has detailed lifetime and degradation parameters. We can also assess novel thermal storage technologies by integrating them into the whole building energy simulation program EnergyPlus. Because the model calls both SAM and EnergyPlus, required inputs need to be compatible for both models. These inputs include, on a high-level, the following: weather files, building and electric vehicle load profiles, electricity rate tariff information, and system cost information for the stationary battery, solar PV, and thermal storage system. The various buildings we are studying for this analysis are retail big-box grocery store, commercial office building, fleet vehicle depot and operations facility, multi-family residential, and electric vehicle charging station. For these different applications, the battery and thermal storage will be dispatched differently, and the various technologies are sized differently to optimize cost.

30 DIRECT ENERGY CONVERSION↗

Dialogue Between Lighting and HVAC Systems: Improving building system integration

Lighting systems have long been capable of sensing when someone enters or exits a room and using that knowledge to turn lights on or off. More recently, connected lighting systems with sensors integrated into every luminaire have become broadly available, facilitating highly granular occupancy detection. Similarly, HVAC systems have long been able to use an understanding of building occupancy to adjust temperature setpoints and reduce energy use without significant impacts to occupant comfort. Energy codes (e.g., ASHRAE/IES Standard 90.1, IECC, Title 24) now require “occupied standby HVAC control,” whereby systems adjust both temperature and ventilation setpoints in zones that are determined to be unoccupied during normal occupancy hours. Here, this article discusses current issues that stymie the integration of Lighting and HVAC systems, and DOE activities focused on addressing them.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Efficient Air Dehumidification Can Save 15%-50% of Cooling Energy in Commercial Buildings

Current approach to dehumidification in commercial buildings with chilled/hot water AHU systems is to overcool return + supply air to dewpoint, and then reheat before supply to zone. This is energy inefficient, with reheat often being gas-fired. To reduce energy consumption, building operators will often operate at little-to-no outside air, sacrificing IAQ. Decarbonizing commercial buildings requires solutions to reduce and fully electrify dehumidification energy consumption. The Altaire ADAPT and Conservant HEDS systems aim to solve this problem by decoupling humidity control from cooling reduces energy consumption while enabling improved IAQ management.

commercial buildings↗

Integrated Thermal Energy Storage System for Air-Conditioners with Phase-Change Composites

Thermal energy storage (TES) is a promising solution to store and dispatch energy and shave peak electric load, reducing the operational cost of HVAC systems. We present results of a TES system using phase-change materials (PCM) integrated with an air conditioner. The proposed system uses an organic PCM (tetradecane) encapsulated within compressed expanded natural graphite foams referred to as phase-change composite. The graphite foam encapsulates the PCM eliminating the need for expensive storage vessels, reduces installation costs, and provides higher thermal conductivity that can lead to faster charge/discharge rates. Two serpentines, multi-pass circuits, operating as a heat source and a sink, exchange heat to and from the phase-change composite. These two circuits are embedded in multiple slabs of this material. The "charge" circuit contains the refrigerant that is directly coupled to a vapor compression system, and the "discharge" circuit removes heat from an airstream and releases it into the PCM composite through a water-glycol liquid coupling. This configuration allows for multiple modes of operation depending on the state of charge of the thermal energy storage module, the building air-conditioning load, and the current electricity and demand charges. This flexible operation allows variable air volume capacity control without the need to have a variable capacity refrigeration system. We developed a 21 kW-hr (6 RT-hr) prototype TES system coupled with a commercial air-conditioner to characterize the component-and system-level performance.

air-conditioning↗

Machine learning-enhanced hybrid modeling approach for better identification of a building thermal network model and improved prediction

The gray-box modeling approach, which uses a semi-physical thermal network model, has been widely used in building prediction applications, such as model predictive control (MPC). However, unmeasured disturbances, such as occupants, lighting, and in/exfiltration loads, make it challenging to apply this approach to practical buildings. In this word, we propose a hybrid modeling approach that integrates the gray-box model with a model for unmeasured disturbance. After reviewing several system identification approaches, we systematically designed the unmeasured disturbance model with a model selection process based on statistical tests to make it robust. We generated data based on the building model calibrated by real operational data and then trained the hybrid model for two different weather conditions. The hybrid model approach demonstrates an RMSE reduction of approximately 0.2–0.9 °C and 0.3–2 °C on 1-day ahead temperature prediction compared to the Conventional approach for mild (Berkeley, CA) and cold (Chicago, IL) climates, respectively. In addition, this approach was applied to experimental data obtained from the laboratory building to be used for the MPC application, showing superior prediction performances.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Linking human-building interactions in shared offices with personality traits

Occupant behavior influences office building energy performance. The level of human-building interactions (HBIs) in shared offices strongly influences building energy use and occupant well-being. This study explored the link between occupant personality types and their behaviors of sharing energy and environment control systems and interactions with their colleagues. Inspired by the Five-Factor Model (FFM), we classified HBI behaviors into four dimensions: willingness to share control, knowledge of control, group decision behavior, and adaptive strategies. These four variables can be mapped to the four personality traits proposed by the FFM: agreeableness, openness, extraversion, and conscientiousness. Our cluster analysis identified six behavioral patterns: average (17.7%), reserved (15.3%), environmentally friendly (16.6%), role model (24.2%), self-centered (17.2%), and mechanist (9.0%). We further applied association rules, a widely utilized machine learning technique, to discover how demographics, building-related contextual factors, and perception-attitudinal factors influence HBI behaviors. Country, control feature accessibility, and group dynamics were found to be the three most influential factors that determine occupants’ HBI behaviors. Finally, the study provides insights about building design and operation, as well as policy to promote socially and environmentally desirable HBI behaviors in a shared office environment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Progress on 3D SRF-based architecture for quantum computing

Superconducting radio frequency (SRF) cavities are excellent choices for storing and manipulating quantum information as quantum d-level systems (qudits) due to their exceptionally long lifetimes and large accessible Hilbert spaces. A common strategy to manipulate the states is to use a nonlinear element like a transmon. We present preliminary experimental results obtained with cavity displacements and selective number dependent arbitrary phase gates for universal qudit control, and its application towards High-energy physics (HEP) simulations and beyond. We discuss the advantages and challenges associated with building a 3D SRF architecture while maintaining long cavity lifetimes in the presence of lossy components. We show how the system coherence properties can be preserved by carefully engineering to minimize the participation of the long coherence modes in different loss channels, while ensuring sufficient quantum controllability. We further discuss the path towards building multi-qudit systems.

Romanenko, Alexander↗

Model based co-simulation platform for integrated building system control and design optimization

Both steady-state and dynamic simulations have been widely used by HVAC&R industry to support product/equipment development for decades. Steady-state simulation focuses on the system mass, energy and momentum balance of an equilibrium state. It is based on high-fidelity components models, and thus is suitable for system and component design optimization. Dynamic simulation studies the system transient response and is generally used for controls development and verification. It usually does not require rigorous component models of high accuracy because 1) the commonly used PID control is feedback control whose control performance evaluation doesn’t require high fidelity system/plant model; 2) high-fidelity dynamic model significantly increases the number of equations and variables and creates tremendous challenge for math solver. For supervisory control, transactive control or optimization of an integrated building system, the HVAC&R equipment is often one of the sub-components to be controlled. High-fidelity equipment models are required for accurately evaluating control strategies. In addition, building equipment manufacturers have developed a lot of high-fidelity steady-state equipment/component models per their expertise. Thus, a platform that can integrate OEM high-fidelity steady-state model with dynamic building simulation and/or electric power system & grid simulation to support the development and verification of supervisory control for integrated building systems is necessary. In this study, ORNL’s heat pump design tool (HPDM) is utilized to develop a co-simulation platform for supervisory control and optimization in integrated building systems. It is based on a model that integrates high-fidelity steady-state simulation equipment models with dynamic building simulation. A practical case of using the proposed co-simulation platform to develop and evaluate the supervisory control and optimization is presented and discussed.

Sun, Jian↗

Intelligent multi-zone residential HVAC control strategy based on deep reinforcement learning

Residential heating, ventilation, and air conditioning (HVAC) has been considered as an important demand response resource. However, the optimization of residential HVAC control is no trivial task due to the complexity of the thermal dynamic models of buildings and uncertainty associated with both occupant-driven heat loads and weather forecasts. In this paper, we apply a novel model-free deep reinforcement learning (RL) method, known as the deep deterministic policy gradient (DDPG), to generate an optimal control strategy for a multi-zone residential HVAC system with the goal of minimizing energy consumption cost while maintaining the users’ comfort. Here, the applied deep RL-based method learns through continuous interaction with a simulated building environment and without referring to any prior model knowledge. Simulation results show that compared with the state-of-art deep Q network (DQN), the DDPG-based HVAC control strategy can reduce the energy consumption cost by 15% and reduce the comfort violation by 79%; and when compared with a rule-based HVAC control strategy, the comfort violation can be reduced by 98%. In addition, experiments with different building models and retail price models demonstrate that the well-trained DDPG-based HVAC control strategy has high generalization and adaptability to unseen environments, which indicates its practicability for real-world implementation.