At least 235 records · Page 13

Vehicle Design Data Format and Process for a Complete TARIS and OLTARIS Radiation Analysis for Designers and Engineers

Protecting astronauts from space radiation is a complex task when it comes to modeling and simulation. This document shows what information is needed from a spacecraft designer using CAD (Computer-Assisted Design) at each phase of the design to enable the engineers to evaluate the design phase against space radiation limits to determine the suitability of the design for space flight. The current personal exposure limits are listed in NASA STD-3001. A proxy to determine the REID (Radiation Exposure Induced Death) in NASA STD-3001 is the whole body effective dose equivalent (E or effective dose). For short-term tissue effects, organ-averaged gray equivalent (G (sub T)) is used. The TARIS (Tool for the Assessment of Radiation In Space - for LaRC (Langley Research Center) engineers) and OLTARIS (On-Line TARIS) - for designers) systems are used to generate these response functions. The E can use ICRP60 or NASA Q-values. A possible space radiation design basis environment for short-term tissue effects is described and used in all analyses. A single space vehicle was designed with three astronaut configurations and two of those configurations were used in a storm shelter thickness perturbation analysis. Conversion of the data from the CAD model to input necessary for TARIS and OLTARIS is also discussed in detail with relevant examples.

Singleterry, Robert C.↗

NASA Screening and Clinical Practice for the Monitoring and Mitigation of Coronary Artery Disease: Application to Terrestrial Practice

Coronary artery disease (CAD) surveillance has led to the development of risk stratification tools that drive clinical mitigation efforts for CAD risk. As common risk assessment tools, including the Framingham Risk Score (FRS) or Pooled Cohort Risk Equations, have insufficient accuracy on an individual level to meet NASA’s stringent screening guidelines, NASA has required new approaches to address the risk of catastrophic cardiovascular (CV) medical events among astronauts. Coronary artery calcium (CAC) scanning has emerged as the current best tool to enhance CV risk assessment in asymptomatic individuals, with risk information incremental to FRS data.

Khera, Amit↗

Application of High-Dimensional Fuzzy K-Means Cluster Analysis to CALIOP/CALIPSO Version 4.1 Cloud-Aerosol Discrimination

This study applies fuzzy k-means (FKM) cluster analyses to a subset of the parameters reported in the CALIPSO lidar level 2 data products in order to classify the layers detected as either clouds or aerosols. The results obtained are used to assess the reliability of the cloud–aerosol discrimination (CAD) scores reported in the version 4.1 release of the CALIPSO data products. FKM is an unsupervised learning algorithm, whereas the CALIPSO operational CAD algorithm (COCA) takes a highly supervised approach. Despite these substantial computational and architectural differences, our statistical analyses show that the FKM classifications agree with the COCA classifications for more than 94 % of the cases in the troposphere. This high degree of similarity is achieved because the lidar-measured signatures of the majority of the clouds and the aerosols are naturally distinct, and hence objective methods can independently and effectively separate the two classes in most cases. Classification differences most often occur in complex scenes (e.g., evaporating water cloud filaments embedded in dense aerosol) or when observing diffuse features that occur only intermittently (e.g., volcanic ash in the tropical tropopause layer). The two methods examined in this study establish overall classification correctness boundaries due to their differing algorithm uncertainties. In addition to comparing the outputs from the two algorithms, analysis of sampling, data training, performance measurements, fuzzy linear discriminants, defuzzification, error propagation, and key parameters in feature type discrimination with the FKM method are further discussed in order to better understand the utility and limits of the application of clustering algorithms to space lidar measurements. In general, we find that both FKM and COCA classification uncertainties are only minimally affected by noise in the CALIPSO measurements, though both algorithms can be challenged by especially complex scenes containing mixtures of discrete layer types. Our analysis results show that attenuated backscatter and color ratio are the driving factors that separate water clouds from aerosols; backscatter intensity, depolarization, and mid-layer altitude are most useful in discriminating between aerosols and ice clouds; and the joint distribution of backscatter intensity and depolarization ratio is critically important for distinguishing ice clouds from water clouds.

Zeng, Shan↗

Common Habitat for Long Duration Transit and Surface Operations

This concept is based on the Skylab II concept, which proposes using a SLS propellant tank as the primary structure of a habitat. Common Habitat takes this a step further, proposing an interior architecture that is equally viable as a lunar surface hab, transit hab, and Mars surface hab, thus enabling a single development to support all three long duration habitat roles. Common Habitat has been pursued by the PI and co-investigators at MSFC and other centers in a spare time / funding available basis, often with heavy student intern support. Student resources have developed preliminary concepts, but these models must be refined to reflect accurate vehicle subsystems, utilities, stowage, workstations, and other crew systems. This investigation applies NASA civil servant and contractor expertise to correct errors in the most recent student concepts in order to prepare them for future human-in-the-loop evaluations to determine the most viable configuration for a Common Habitat. In prior studies there was never an opportunity to trade both crew size and internal orientation. Prior work has been a series of point designs with inconsistent design constraints, making apples to apples comparisons impossible. The most recent student work produced CAD models of four habitat variants for future use in a trade study, but the student products contain model construction and geometry errors, inaccurate subsystems design and placement, and unrealistic structural elements and outfitting. These must be corrected before the models can be moved into a VR environment for humanin- the-loop testing. Through consultation with SMEs throughout the Agency, the fidelity of these designs will be upgraded to a level of quality sufficient to make a comparative analysis of crew size sensitivity and internal orientation. The product of this activity is four upgraded CAD models, each reflecting a different configuration of the Common Habitat. One is a horizontal configuration using the full length of the SLS LOX tank. One is a vertical configuration using the same tank dimensions. The third is a horizontal configuration using a truncated SLS LOX tank (half the barrel length). The fourth is a vertical configuration of the half-length SLS LOX tank.

Howard, Robert L.↗

Functional Volume Assessment of an Early Version of the Mars Transit Habitat

During the summer of 2020, the NASA Mars Architecture Team (MAT) conducted a functional volume assessment of the Transit Habitat (TH). The TH has evolved substantially since that time and the current TH does not share the same internal configuration, but the insights gained from the assessment remain relevant. In virtually all architectures involving chemical, electric, or nuclear propulsion, the majority of the crew mission is spent aboard the TH. The Earth to Mars transit durations may vary from architecture to architecture, but all are on the order of hundreds of days, regardless of whether an opposition or conjunction class trajectory is selected, and regardless of whether the propulsion system is chemical, electric, or nuclear. Thus, the TH must provide capabilities appropriate to a very long duration. So, despite significant changes in the current Mars architecture over the past few years, this evaluation still provides useful recommendations in the form of habitability guidance that can be applied to current and future TH concepts. This assessment had six primary objectives: provide a sanity check to the BOC-derived TH layout; understand if we can fit the hardware and functional tasks in the volume; provide a high-level assessment of how aggressive the layout is; generate a list of challenges or assumptions necessary to make it work; generate a list of future work to refine understanding; and identify proposed requirements. All of this information is critical to drive habitat sizing studies and key architecture decisions. It was clear that a human-in-the-loop (HITL) evaluation of some kind would be necessary, but several challenges were immediately identified. The most information could be gleaned from a Desert Research and Technology Studies (DRATS) type of mission operations test (MOT), but the TH concept was too low fidelity to construct the type of prototype necessary to conduct a MOT, nor were their financial resources to do so. The next best option – and really the one most appropriate for the BOC’s stage of maturity – is a Virtual Reality (VR) walk-through evaluation. However, NASA was in a shutdown state due to the COVID-19 pandemic and the VR labs were inaccessible. As a result, a tabletop evaluation was created, using .jpg imagery from the ECM CAD model along with Excel-based datasheets. High-level crew living and working functions within the habitat were identified for evaluation. Questionnaires using Likert scales assessed acceptability of habitat functions and sim quality – the degree to which the function was represented in CAD. This enabled the evaluation to be conducted by personnel working remotely. Each function was evaluated individually along with several overarching habitability parameters and vehicle subsystems. The results of this evaluation are discussed, including methodological challenges and rating challenges. Acceptability results are discussed for functions that the participants were able to rate and participant comments for functions that could not be related are also described. Final conclusions are described, including challenges or assumptions needed to make the TH design acceptable, future work needed to refine understanding of the TH, and proposed habitat requirements based on test data.

Transit Habitat↗

Configuration and Projected Capabilities of the Common Habitat Medical Care Facility

The Common Habitat is a large, long-duration habitat being explored as part of a conceptual study (not an active NASA program) that uses an SLS core stage Liquid Oxygen (LOX) tank as its primary structure. It is intended for use on the Moon as part of a permanently occupied outpost, on Mars as part of an outpost that will be occupied for hundreds of days at a time, and in deep space as part of the Deep Space Exploration Vehicle where it will support crewed missions up to 1200 days in duration. A study of internal orientation and crew size resulted in a Common Habitat configuration sized for a crew of eight with a three-deck horizontal orientation. Additional work outside the scope of this paper is developing a vertical translation system, a crew mobility aids system based on wearable gecko-derived grippers, and a crew seating/restraint system. These systems are all assumed for use in conjunction with the Medical Care Facility, which is needed to maintain crew well-being during these missions, where distance from Earth precludes the possibility of evacuation to Earth. This paper describes recent improvements in the Common Habitat Medical Care Facility and associated benefits for crew survivability in long duration missions beyond Earth orbit. These improvements were made with the assistance of a NASA Pathways intern whose experience includes a tour of duty in Afghanistan as an Army combat medic with the 691st GHOST-T, attached to the 1st and 7th US Special Forces Groups as part of Operation Freedom’s Sentinel, where he helped provide far-forward surgical capabilities in austere combat environments. The initial baseline Medical Care Facility was developed working in conjunction with University of Houston Space Architecture graduate students. The facility was placed on the upper deck of the Common Habitat in a location that provided privacy, operational volume, and was close to the vertical translation pathway. The notional outfitting repurposed component CAD models from unrelated studies and notionally indicated a level of care roughly equivalent to that aboard the International Space Station. The CAD modeling provided notional stowage volumes, a deployable surface, some fixed equipment, an ultrasound, and a potentially reconfigurable treatment table. While this facility is clearly a competent arrangement, it was desired to leverage available expertise and upgrade the station given the vast distances from Earth to be experienced by the Common Habitat. Key driving requirements applied to the upgrade included to provide Medical Level of Care V, offer enhanced telemedicine capabilities, provide patient physical accommodation, provide caregiver access to the patient from all sides, include sliding pocket doors for access to hygiene and to the Vertical Translation System, and to add any additional capability possible for the best achievable medical care. The first step in the facility upgrade was to quantify the current medical inventory on the International Space Station and ensure that sufficient stowage volume was present for this purpose. To that end, the ISS medical kits were reviewed, and eight full size mid deck lockers were placed in the facility. A number of additional devices were also added, based on the intern’s combat medic experience. Also, two fixed shelves and one horizontal work surface were added to the Medical Care Facility, with the shelves providing storage space for the additional devices and the work surface providing a location for the caregiver to work or stage equipment. Four display monitors were added to the wall above the horizontal work surface, supporting data display, telemedicine, conferencing, or other needs. The existing treatment table was replaced with a mobile surgical stretcher-chair. Two additional doors were added to the Medical Care Facility. One leads directly to the hygiene compartment, allowing it to support medical operations in addition to providing galley/wardroom support. The other door leads directly into the Vertical Translation System. The wall adjacent to the subsystems bay was moved, adding additional volume to the Medical Care Facility. This improved caregiver access to the patient and allowed for a larger number of caregivers to be present. It also provided options for relocation of support equipment relative to the patient as needed. In the upgraded Medical Care Facility, the Surgical Stretcher-Chair and the Vertical Translation System can work together to provide incapacitated crew member transport from a site of injury on any deck of the Common Habitat to the Medical Care Facility. It can also support patient treatment in a variety of positions including a variety of sitting postures and a supine posture at a variety of pitch angles. The facility can also support caregiver office work for review of examination results, private consultation, inventory and maintenance, and a variety of other purposes. A forward activity will be to conduct evaluations of the Medical Care Facility with different medical scenarios. Additionally, ambient and task lighting selections remain as forward work. The eight mid deck lockers can be augmented to use as portable equipment carts, similar to a manner in which maintenance facility stowage was used as portable carts during the NASA Desert Research and Technology Studies in the Constellation Program. Trash accommodation will also need forward work to assess, including provision for wet trash, dry trash, and biological waste. It will be important to assess a redesign of the surgical stretcher-chair. The commercial version used in the upgrade can only enable vertical translation in the seated configuration, requiring the patient to bend both hips and knees. A possible redesign of the chair will allow for vertical translation without requiring any bending at the hip or knees. Also, the commercial version is wheeled, making it mobile in gravity but unanchored in microgravity. Work will be needed to adapt the chair for gravity-independent performance. The hygiene compartment can be redesigned for dual-use medical scrub and galley handwash facility. Pending sufficient volume, it may also be possible to place sanitation equipment in this location to clean medical tools. Finally, most space architectures have never allowed for more than one incapacitated crew member, but several scenarios could potentially injure two or more crew in the same incident. This facility could be assessed to determine its present ability to address two or more injured crew in parallel and determine the potential upper limit for number of treatable crew in a multi-crew injury scenario, or to treat polytrauma of a single patient.

Habitat↗

Configuration and Projected Capabilities of the Common Habitat Medical Care Facility

The Common Habitat is a large, long-duration habitat being explored as part of a conceptual study (not an active NASA program) that uses an SLS core stage Liquid Oxygen (LOX) tank as its primary structure. It is intended for use on the Moon as part of a permanently occupied outpost, on Mars as part of an outpost that will be occupied for hundreds of days at a time, and in deep space as part of the Deep Space Exploration Vehicle where it will support crewed missions up to 1200 days in duration. A study of internal orientation and crew size resulted in a Common Habitat configuration sized for a crew of eight with a three-deck horizontal orientation. Additional work outside the scope of this paper is developing a vertical translation system, a crew mobility aids system based on wearable gecko-derived grippers, and a crew seating/restraint system. These systems are all assumed for use in conjunction with the Medical Care Facility, which is needed to maintain crew well-being during these missions, where distance from Earth precludes the possibility of evacuation to Earth. This paper describes recent improvements in the Common Habitat Medical Care Facility and associated benefits for crew survivability in long duration missions beyond Earth orbit. These improvements were made with the assistance of a NASA Pathways intern whose experience includes a tour of duty in Afghanistan as an Army combat medic with the 691st GHOST-T, attached to the 1st and 7th US Special Forces Groups as part of Operation Freedom’s Sentinel, where he helped provide far-forward surgical capabilities in austere combat environments. The initial baseline Medical Care Facility was developed working in conjunction with University of Houston Space Architecture graduate students. The facility was placed on the upper deck of the Common Habitat in a location that provided privacy, operational volume, and was close to the vertical translation pathway. The notional outfitting repurposed component CAD models from unrelated studies and notionally indicated a level of care roughly equivalent to that aboard the International Space Station. The CAD modeling provided notional stowage volumes, a deployable surface, some fixed equipment, an ultrasound, and a potentially reconfigurable treatment table. While this facility is clearly a competent arrangement, it was desired to leverage available expertise and upgrade the station given the vast distances from Earth to be experienced by the Common Habitat. Key driving requirements applied to the upgrade included to provide NASA’s Medical Level of Care V, offer enhanced telemedicine capabilities, provide patient physical accommodation, provide caregiver access to the patient from all sides, include sliding pocket doors for access to hygiene and to the Vertical Translation System, and to add any additional capability possible for the best achievable medical care. The first step in the facility upgrade was to quantify the current medical inventory on the International Space Station and ensure that sufficient stowage volume was present for this purpose. To that end, the ISS medical kits were reviewed, and eight full size mid deck lockers were placed in the facility. A number of additional devices were also added, based on the co-author’s combat medic experience. Also, two fixed shelves and one horizontal work surface were added to the Medical Care Facility, with the shelves providing storage space for the additional devices and the work surface providing a location for the caregiver to work or stage equipment. Four display monitors were added to the wall above the horizontal work surface, supporting data display, telemedicine, conferencing, or other needs. The existing treatment table was replaced with a mobile surgical stretcher-chair. Two additional doors were added to the Medical Care Facility. One leads directly to the hygiene compartment, allowing it to support medical operations in addition to providing galley/wardroom support. The other door leads directly into the Vertical Translation System. The wall adjacent to the subsystems bay was moved, adding additional volume to the Medical Care Facility. This improved caregiver access to the patient and allowed for a larger number of caregivers to be present. It also provided options for relocation of support equipment relative to the patient as needed. In the upgraded Medical Care Facility, the Surgical Stretcher-Chair and the Vertical Translation System can work together to provide incapacitated crew member transport from a site of injury on any deck of the Common Habitat to the Medical Care Facility. It can also support patient treatment in a variety of positions including a variety of sitting postures and a supine posture at a variety of pitch angles. The facility can also support caregiver office work for review of examination results, private consultation, inventory and maintenance, and a variety of other purposes. A forward activity will be to conduct evaluations of the Medical Care Facility with different medical scenarios. Additionally, ambient and task lighting selections remain as forward work. The eight middeck lockers can be augmented to use as portable equipment carts, similar to a manner in which maintenance facility stowage was used as portable carts during the NASA Desert Research and Technology Studies in the Constellation Program. Trash accommodation will also need forward work to assess, including provision for wet trash, dry trash, and biological waste. It will be important to assess a redesign of the surgical stretcher-chair. The commercial version used in the upgrade can only enable vertical translation in the seated configuration, requiring the patient to bend both hips and knees. A possible redesign of the chair will allow for vertical translation without requiring any bending at the hip or knees. Also, the commercial version is wheeled, making it mobile in gravity but unanchored in microgravity. Work will be needed to adapt the chair for gravity-independent performance. The hygiene compartment can be redesigned to serve both as a medical scrub facility and for galley hand washing. Pending sufficient volume, it may also be possible to place sanitation equipment in this location to clean medical tools. Finally, most space architectures have never allowed for more than one incapacitated crew member, but several scenarios could potentially injure two or more crew in the same incident. This facility could be assessed to determine its present ability to address two or more injured crew in parallel and determine the potential upper limit for number of treatable crew in a multi-crew injury scenario, or to treat polytrauma of a single patient.

Common Habitat↗

Rapid Model Import Tool (RMIT) User Guide

The NASA Rapid Model Import Tool (RMIT) is designed to import 3D models built in commercially available Computer Aided Design (CAD) and Digital Content Creation (DCC) development software such as; Catia, Creo, 3DS Max, Maya, etc. Upon import, RMIT processes the models to reduce file size and exports the results in a format compatible with Augmented Reality (AR) and Virtual Reality (VR) development software applications. RMIT intends to make CAD models directly accessible to engineers from local AR/VR compatible laptops and desktops.

Joseluis Chavez↗

Parametric Mechanism Design Through Numerical Optimization and Physics Simulation

Design-Build-Test approaches for developing spaceflight hardware are prohibitively time and cost intensive and often lead to suboptimal mechanism designs. Approaches that couple machine learning and high-fidelity physics simulation could eliminate the need for hardware prototyping and dramatically accelerate the engineering design cycle, ultimately reducing cost. This work presents a modular NASA-developed toolchain to optimize hardware mechanisms in a virtual environment using numerical optimization and multi-body physics simulation. The toolchain enables multi-objective optimization, generates parametric CAD files that can be further post-processed by an end user, and can be expanded to optimize full systems and non-mechanical parameters such as feedback control variables. We demonstrate the toolchain through an independently verifiable design problem that optimizes wheel radius to achieve a desired linear velocity in a rigid-body physics environment when the wheel rotates at a constant angular speed, and then post-process the parametric CAD file of the optimal design generated by the tool before ultimately manufacturing it via 3D printing. We end with a discussion of how the toolchain can incorporate other analysis tools, including finite element analysis, computational fluid dynamics, and granular media simulations.

Optimization↗

Artemis 1 Radiation Modeling and Analysis Using Operational Methods

The successful completion of the Artemis 1 mission has provided NASA with a significant volume of space radiation dosimetry data that can be used to verify the accuracy of current operational SRAG dose computation models and methods for Beyond LEO missions. High-Fidelity CAD models of the Artemis 1 MPCV Orion were raytraced in 10,000 directions per sensor location, including the location of Artemis HERA sensors, Artemis RAMs (TLDs), and the crew active dosimetry (CADs). The full Artemis 1 mission was modelled using the as-flown trajectory, Ap9-Ae9 IRENE providing the VAB trapped proton and electron environment, and the Badhwar-O’Neill 2020 model providing the freespace GCR environment. IGRF 12 was used to compute cutoff rigidities for the GCR environment in LEO. 1DHZETRN was used to estimate point doses at each sensor position. Computed RAM doses were within 5% of measured values. The computed VAB transit and freespace GCR dose rates showed good qualitative agreement with measured HERA values. An estimate of normalized mean effective dose for a hypothetical male crew member on Artemis 1 using current standard operational methods was computed to be 22.3 mSv.

Artemis 1↗

An Optimization-Based Toolchain for Parametric Mechanism Design

Design-Build-Test approaches for developing spaceflight hardware are prohibitively time and cost intensive and often lead to suboptimal mechanism designs. Approaches that couple machine learning and high-fidelity physics simulation could eliminate the need for hardware prototyping and dramatically accelerate the engineering design cycle, ultimately reducing cost. This work presents a modular NASA-developed toolchain to optimize hardware mechanisms in a virtual environment using numerical optimization and multi-body physics simulation. The toolchain enables multi-objective optimization, generates parametric CAD files that can be further post-processed by an end user, and can be expanded to optimize full systems and non-mechanical parameters such as feedback control variables. We demonstrate the toolchain through an independently verifiable design problem that optimizes wheel radius to achieve a desired linear velocity in a rigid-body physics environment when the wheel rotates at a constant angular speed, and then post-process the parametric CAD file of the optimal design generated by the tool before ultimately manufacturing it via 3D printing. We end with a discussion of how the toolchain can incorporate other analysis tools, including finite element analysis, computational fluid dynamics, and granular media simulations.

Optimization↗

NASA HECC Geometry and Performance Review Part 1: Validation of a Computational Model for the Vaneless Diffuser Configuration with As-Manufactured Impeller Geometry

An investigation of the NASA High Efficiency Centrifugal Compressor (HECC) vaneless diffuser configuration was performed. This multipart investigation presents an extensive validation of the computational model against experimental data. The validated model was then used to explore the effects geometric differences between the as-manufactured and design-intent impellers. Lastly, the validated model was used for comparison against an experimental tip clearance study. Part I of the investigation focused on describing the HECC vaneless computational model and its validation against the experimental data published in GT2023-103128. To generate the model, a verification of the manufactured impeller was performed and was confirmed to match the impeller CAD. Section data from the impeller CAD, referred to as the As-Manufactured geometry, were used for development of the computational model. Steady RANS simulations utilizing the Wilcox K-Omega 98 turbulence model and a multiblock structured mesh were used to conduct a mesh convergence study. The resultant mesh was then used for simulations at both design-speed and off-design speed conditions. The simulations compared well to data in both 1D and 2D terms for the major performance metrics of efficiency, total pressure rise, and total temperature rise. Based on the observed results the model was deemed validated and was used in the latter two parts of the multipart investigation.

centrifugal compressor↗

NASA HECC Geometry and Performance Review Part 1: Validation of a Computational Model for the Vaneless Diffuser Configuration with As-Manufactured Impeller Geometry

An investigation of the NASA High Efficiency Centrifugal Compressor (HECC) vaneless diffuser configuration was performed. This multipart investigation focused on validating the computational model against experimental data. The validated model was then used to explore the effects of observed geometric differences between the as-manufactured and design-intent impellers. Lastly, the validated model was used for comparison against an experimental tip clearance study. Details regarding each of the parts are detailed below: A multipart investigation of the NASA High Efficiency Centrifugal Compressor (HECC) vaneless diffuser configuration was performed. Part I of the investigation focused on describing the HECC vaneless computational model and its validation against the experimental data published in GT2023-103128. To generate the model, a verification of the manufactured impeller was performed and was confirmed to match the impeller CAD. Section data from the impeller CAD, referred to as As-Manufactured, were used in the model. Steady RANS simulations using a multiblock structured mesh were used to conduct a mesh convergence study. The resultant mesh was then used for simulations at both design-speed and off-design speed conditions. The simulations compared well to data in both 1D and 2D terms. Based on the observed results the model was deemed validated and was used in the latter two parts of the multipart investigation.

centrifugal compressor↗

Working with Bezier Curves as bases for Functional Expansion Tallies

Functional expansion tallies (FETs) are a powerful tool for getting more information per history from Monte Carlo simulations, but in the past they have been constrained to orthogonal bases. Bezier curves, from computer aided design (CAD), could be well suited for FET due to their ability to assume many arbitrary shapes, but are non-orthogonal. Recent development has made non-orthongal FET possible. The convergence of B ´ezier curve FETs in both polynomial order and number of samples is explored. These bases are well suited for representing normal distributions, and opens the door to possible other CAD derived FET bases.

97 MATHEMATICS AND COMPUTING↗

Working with Bézier Curves as bases for Functional Expansion Tallies

Functional expansion tallies (FETs) are powerful tools for getting more information per history from Monte Carlo simulations, but in the past they have been constrained to orthogonal bases. Bézier curves are used widely in computer aided design (CAD) geometry kernels and could be well-suited for FETs due to their ability to assume many arbitrary shapes, but they use nonorthogonal bases. Recent developments in 2021 have made nonorthogonal FETs possible. The convergence of Bézier curve FETs in both polynomial order and number of samples is explored in this work. It is shown that these bases are well-suited for representing normal distributions and this opens the door to the possibility of other CAD-derived FET bases.

97 - MATHEMATICS AND COMPUTING↗

Statistical Tolerance and Clearance Analysis for Assembly

Tolerance is inevitable because manufacturing exactly equal parts is known to be impossible. Furthermore, the specification of tolerances is an integral part of product design since tolerances directly affect the assemblability, functionality, manufacturability, and cost effectiveness of a product. In this paper, we present statistical tolerance and clearance analysis for the assembly. Our proposed work is expected to make the following contributions: (i) to help the designers to evaluate products for assemblability, (ii) to provide a new perspective to tolerance problems, and (iii) to provide a tolerance analysis tool which can be incorporated into a CAD or solid modeling system.

statistical tolerance clearance analysis Monte-Car↗

An End-to-End Framework for Verifying and Validating Manufacturing Design Integrity

Cyber attacks on networked automated manufacturing systems can severely impact part quality. In fact, malicious modifications may be introduced at any point during the manufacturing lifecycle. Therefore, it is vital to verify and validate that manufactured parts conform to their designs. This chapter describes a formal, end-to-end framework that verifies and validates the design integrity of manufactured parts by considering all potential points of alteration during precision manufacturing processes. The framework prevents unauthorized changes to computer-aided designs, verifies the correctness of translations from CAD models to G-code, maintains the integrity of G-code transferred to manufacturing machines, verifies the runtime execution of G-code and part geometry, and considers the contexts of manufacturing machine operations and how manufactured parts could be altered.

Jablonski, Matthew [Cybersecurity Manufacturing In↗

Design and scale-up of 3D printed bat houses with biomass-derived polymer composites

Biomass (e.g., pine sawdust, especially high–ash content pine sawdust) is commonly disposed of as waste. Combining biomass with polymers to make composite feedstocks for 3D printing has been explored as a method to reduce or repurpose the biomass waste. Although not all biocomposite properties are known, the wood-based polylactic acid (PLA) composite has promising qualities for applications in ecological settings. In this work, pine wood–PLA composite feedstock was used to 3D print supplemental roost structures for endangered tree-roosting bats, which often face a paucity of suitable naturally occurring roosts. This material combination was selected because it is estimated to degrade faster than the synthetic material systems that are used widely in supplemental bat roosting structures to aid in the conservation of tree roosting bats. The layered, rough surface created by the 3D printing process serves as a surface that bats can grip while roosting. Computer-aided design (CAD) models were generated based on natural roost structures, and a full-size bat house was successfully additively manufactured using a pellet-fed large-scale 3D printing system. The 3D printed hexagon exhibited a tensile strength of 22–23 MPa and a Young’s modulus of 3202–3218 MPa in the x-direction. It has been demonstrated that the 3D printed bat house can be installed on a tree in a stable fashion. This successful demonstration of a bat roost manufactured using a bioderived composite should promote its use in other fish and wildlife structures and broader industrial applications such as construction and automobiles.

3D printing↗