Search NASA⌕ Search

SEARCH · Search NASA

Results for “CALIBRATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Cross-calibration between airborne SAR sensors

As Synthetic Aperture Radar (SAR) system performance and experience in SAR signature evaluation increase, quantitative analysis becomes more and more important. Such analyses require an absolute radiometric calibration of the complete SAR system. To keep the expenditure on calibration of future multichannel and multisensor remote sensing systems (e.g., X-SAR/SIR-C) within a tolerable level, data from different tracks and different sensors (channels) must be cross calibrated. The 1989 joint E-SAR/DC-8 SAR calibration campaign gave a first opportunity for such an experiment, including cross sensor and cross track calibration. A basic requirement for successful cross calibration is the stability of the SAR systems. The calibration parameters derived from different tracks and the polarimetric properties of the uncalibrated data are used to describe this stability. Quality criteria for a successful cross calibration are the agreement of alpha degree values and the consistency of radar cross sections of equally sized corner reflectors. Channel imbalance and cross talk provide additional quality in case of the polarimetric DC-8 SAR.

Zink, Manfred↗

Software For Calibration Of Polarimetric SAR Data

POLCAL (Polarimetric Radar Calibration) software tool intended to assist in calibration of synthetic-aperture radar (SAR) systems. In particular, calibrates Stokes-matrix-format data produced as standard product by NASA/Jet Propulsion Laboratory (JPL) airborne imaging synthetic aperture radar (AIRSAR). Version 4.0 of POLCAL is upgrade of version 2.0. New options include automatic absolute calibration of 89/90 data, distributed-target analysis, calibration of nearby scenes with corner reflectors, altitude or roll-angle corrections, and calibration of errors introduced by known topography. Reduces crosstalk and corrects phase calibration without use of ground calibration equipment. Written in FORTRAN 77.

Van Zyl, Jakob↗

Summary of OARE flight calibration measurements

To date, the Orbital Acceleration Research Experiment (OARE) has flown on the shuttle orbiter for five missions; namely, STS-40, STS-50, STS-58, STS-62, and STS-65. The OARE instrument system contains a three-axis accelerometer which can resolve accelerations to the nano-g (10(exp -9) g) level and a full calibration station to permit in situ bias and scale factor calibration measurements. This calibration capability eliminates the large uncertainty encountered with accelerometers flown in the past on the orbiter which use ground-based calibrations to provide absolute acceleration measurements. A detailed flight data report presentation is given for the OARE calibration measurements from all missions, along with an estimate of the calibration errors. The main aim is to collect, process, and present the calibration data in one archival report. These calibration data are the necessary key ingredient to produce the absolute acceleration levels from the OARE acceleration flight data.

Blanchard, Robert C.↗

Multifrequency, Multipolarization External Calibration of the SIR-C/X-SAR Radars

Progress and the future plans for the following objectives are discussed: (1) Assess the accuracy at which the SIR-C/X-SAR standard data products can be calibrated through the use of ground calibrators to estimate the end-to-end system polarization calibration constants (or distortion parameters) and incorporate the constants into the data processing; (2) Study the cross-calibration between three multipolarization systems: SIR-C, the National Aeronautics and Space Administration/Jet Propulsion Laboratory (NASA/JPL) DC-8 SAR, and the University of Michigan ground-based polarimetric scatterometer; (3) Evaluate the calibration "stability" of SIR-C/X-SAR (measured by variations in the calibration constants) over the range swath width and over a specified distance in azimuth. Variations over a 12-hour period (between ascending and descending passes) will also be studied; and (4) Develop a cost-effective calibration plan including development of inexpensive polarimetric active calibrators.

Freeman, Anthony↗

Self-Calibrating and Remote Programmable Signal Conditioning Amplifier System and Method

A self-calibrating, remote programmable signal conditioning amplifier system employs information read from a memory attached to a measurement transducer for automatic calibration. The signal conditioning amplifier is self-calibrated on a continuous basis through use of a dual input path arrangement, with each path containing a multiplexer and a programmable amplifier. A digital signal processor controls operation of the system such that a transducer signal is applied to one of the input paths, while one or more calibration signals are applied to the second input path. Once the second path is calibrated, the digital signal processor switches the transducer signal to the second path. and then calibrates the first path. This process is continually repeated so that each path is calibrated on an essentially continuous basis. Dual output paths are also employed which are calibrated in the same manner. The digital signal processor also allows the implementation of a variety of digital filters which are either programmed into the system or downloaded by an operator, and performs up to eighth order linearization.

Medelius, Pedro J.↗

The Algorithm for MODIS Wavelength On-Orbit Calibration Using the SRCA

The Spectro-Radiometric Calibration Assembly (SRCA) provides on-orbit spectral calibration of the MODerate resolution Imaging Spectroradiometer (MODIS) reflected solar bands and this paper describes how it is accomplished. The SRCA has two adjacent exit slits: 1) Main slit and 2) Calibration slit. The output from the main slit is measured by a reference silicon photo-diode (SIPD) and then passes through the MODIS. The output from the calibration slit passes through a piece of didymium transmission glass and then it is measured by a calibration SIPD. The centroids of the sharp spectral peaks of a didymium glass are utilized as wavelength standards. After normalization using the reference SIPD signal to eliminate the effects of the illuminating source spectra, the calibration SIPD establishes the relationship between the peaks of the didymium spectra and the grating angle; this is accomplished through the grating equation. In the grating equation the monochromator parameters, Beta (half angle between the incident and diffractive beams) and Theta(sub off) (offset angle of the grating motor) are determined by matching, in a least square sense, the known centroid wavelengths of the didymium peaks and the calculated centroid grating angles from the calibration SIPD signals for the peaks. A displacement between the calibration SIPD and the reference SIPD complicates the signal processing.

Montgomery, Harry↗

Uncertainty Analysis of Instrument Calibration and Application

Experimental aerodynamic researchers require estimated precision and bias uncertainties of measured physical quantities, typically at 95 percent confidence levels. Uncertainties of final computed aerodynamic parameters are obtained by propagation of individual measurement uncertainties through the defining functional expressions. In this paper, rigorous mathematical techniques are extended to determine precision and bias uncertainties of any instrument-sensor system. Through this analysis, instrument uncertainties determined through calibration are now expressed as functions of the corresponding measurement for linear and nonlinear univariate and multivariate processes. Treatment of correlated measurement precision error is developed. During laboratory calibration, calibration standard uncertainties are assumed to be an order of magnitude less than those of the instrument being calibrated. Often calibration standards do not satisfy this assumption. This paper applies rigorous statistical methods for inclusion of calibration standard uncertainty and covariance due to the order of their application. The effects of mathematical modeling error on calibration bias uncertainty are quantified. The effects of experimental design on uncertainty are analyzed. The importance of replication is emphasized, techniques for estimation of both bias and precision uncertainties using replication are developed. Statistical tests for stationarity of calibration parameters over time are obtained.

Tripp, John S.↗

The Algorithm for MODIS Wavelength On-Orbit Calibration using the SRCA

The Spectro-Radiometric Calibration Assembly (SRCA) provides on-orbit spectral calibration of the MODerate resolution Imaging Spectroradiometer (MODIS) reflected solar bands and this paper describes how it is accomplished. The SRCA has two adjacent exit slits: 1) Main slit and 2) Calibration slit. The output from the main slit is measured by a reference silicon photo-diode (SIPD) and then passes through the MODIS. The output from the calibration slit passes through a piece of didymium transmission glass and then it is measured by a calibration SIPD. The centroids of the sharp spectral peaks of a didyrnium glass are utilized as wavelength standards. After normalization using the reference SIPD signal to eliminate the effects of the illuminating source spectra, the calibration SIPD establishes the relationship between the peaks of the didymium spectra and the grating angle; this is accomplished through the grating equation. In the grating equation the monochromator parameters, beta (half angle between the incident and diffractive beams) and theta(sub ff) (offset angle of the grating motor) are determined by matching, in a least square sense, the known centroid wavelengths of the didymium peaks and the calculated centroid grating angles from the calibration SIPD signals for the peaks. A displacement between the calibration SIPD and the reference SIPD complicates the signal processing. The response of the MODIS bands to the SRCA output is also normalized by the reference SIPD signal to eliminate the effect of the source spectrum. That response differs from what is measured by MODIS using the Spectral Measurements Assembly (SpMA), a laboratory double-monochromator, due to the wider slit width of the SRCA. The SRCA slit function, calculated using measurements by the SPMA and the SRCA at the same MODIS temperature, will be used to recover the MODIS spectral response using the SRCA data measured on-orbit.

Montgomery, Harry↗

Comparison of Continuous Wave CO2 Doppler Lidar Calibration Using Earth Surface Targets in Laboratory and Airborne Measurements

Routine backscatter, beta, measurements by an airborne or space-based lidar from designated earth surfaces with known and fairly uniform beta properties can potentially offer lidar calibration opportunities. This can in turn be used to obtain accurate atmospheric aerosol and cloud beta measurements on large spatial scales. This is important because achieving a precise calibration factor for large pulsed lidars then need not rest solely on using a standard hard target procedure. Furthermore, calibration from designated earth surfaces would provide an inflight performance evaluation of the lidar. Hence, with active remote sensing using lasers with high resolution data, calibration of a space-based lidar using earth's surfaces will be extremely useful. The calibration methodology using the earth's surface initially requires measuring beta of various earth surfaces simulated in the laboratory using a focused continuous wave (CW) CO2 Doppler lidar and then use these beta measurements as standards for the earth surface signal from airborne or space-based lidars. Since beta from the earth's surface may be retrieved at different angles of incidence, beta would also need to be measured at various angles of incidences of the different surfaces. In general, Earth-surface reflectance measurements have been made in the infrared, but the use of lidars to characterize them and in turn use of the Earth's surface to calibrate lidars has not been made. The feasibility of this calibration methodology is demonstrated through a comparison of these laboratory measurements with actual earth surface beta retrieved from the same lidar during the NASA/Multi-center Airborne Coherent Atmospheric Wind Sensor (MACAWS) mission on NASA's DC8 aircraft from 13 - 26 September, 1995. For the selected earth surface from the airborne lidar data, an average beta for the surface was established and the statistics of lidar efficiency was determined. This was compared with the actual lidar efficiency determined with the standard calibrating hard target.

Jarzembski, Maurice A.↗

Landsat-7 EMT+ On-Orbit Radiometric Calibration

Landsat-7 was launched on April 15, 1999 and completed its on orbit initialization and verification period on June 28, 1999. The ETM+ payload is similar to the TM sensors on previous Landsat satellites and incorporates two new devices to improve its absolute radiometric calibration. The Full Aperture Solar Calibrator (FASC) is a deployable diffuser panel. This device has been deployed 9 times to date, with a normal deployment schedule of once per month. The initial analysis of the FASC data has given absolute calibration results within 5% of the prelaunch integrating sphere calibrations and a range of variation of 2% between dates. The Partial Aperture Solar Calibrator (PASC), is a set of auxiliary optics that allows the ETM+ to view the sun through a reduced aperture. Data have normally been acquired on a daily basis with the PASC. Initial results with the PASC were encouraging, despite some unexpected saturation in the shortest wavelength band. The response of the ETM+ short wavelength (silicon) bands to the PASC increased initially and has begun to decrease in some of these bands. The longer wavelength (InSb) bands have shown up to 30% oscillations that vary between detectors within the band. Studies are ongoing to better characterize the response to the PASC. The ETM+ also incorporates an internal calibrator (IC), a shutter that oscillates in front of the focal plane that directs light from the internal calibrator lamps to the focal plane. The responses to this device are also varying, though differently than the PASC results. Both the IC and PASC results are attributable to the calibration devices as opposed to the ETM+ itself.

Markham, Brian L.↗

Solar-Reflectance-Based Calibration of Spectral Radiometers

A method by which to calibrate a spectral radiometer using the sun as the illumination source is discussed. Solar-based calibrations eliminate several uncertainties associated with applying a lamp-based calibration to field measurements. The procedure requires only a calibrated reflectance panel, relatively low aerosol optical depth, and measurements of atmospheric transmittance. Further, a solar-reflectance-based calibration (SRBC), by eliminating the need for extraterrestrial irradiance spectra, reduces calibration uncertainty to approximately 2.2% across the solar-reflective spectrum, significantly reducing uncertainty in measurements used to deduce the optical properties of a system illuminated by the sun (e.g., sky radiance). The procedure is very suitable for on-site calibration of long-term field instruments, thereby reducing the logistics and costs associated with transporting a radiometer to a calibration facility.

Cattrall, Christopher↗

Prelaunch Instrument Calibration in the Real World: The GOES Example

The pre-launch ground infrared calibration of the Geostationary Operational Environmental Satellite (GOES) N-Q Imager and Sounder is presented. Ground calibration provides information necessary to the accurate on-orbit calibration of these radiometers. Infrared channels are calibrated in a thermal vacuum environment, under minimum and maximum mission operation temperatures, using a variable-temperature warm target to simulate the Earth scene and a cold target to simulate the space scene. Brightness temperatures derived from observation of the instrument internal calibration target, used for on-orbit calibration, are compared to brightness temperatures of the external calibration target as a check of relative accuracy using these two sources. Changes to the GOES N-Q specification from GOES I-M are highlighted, as well as results of noise, relative calibration accuracy, and spectral response performance to date. For completeness, results of spatial and pointing performance will be presented. Enhancements to test methodology and data processing techniques are highlighted throughout.

Murphy-Morris, J.↗

Experimental Investigations of Non-Stationary Properties In Radiometer Receivers Using Measurements of Multiple Calibration References

Radiometers must be periodically calibrated because the receiver response fluctuates. Many techniques exist to correct for the time varying response of a radiometer receiver. An analytical technique has been developed that uses generalized least squares regression (LSR) to predict the performance of a wide variety of calibration algorithms. The total measurement uncertainty including the uncertainty of the calibration can be computed using LSR. The uncertainties of the calibration samples used in the regression are based upon treating the receiver fluctuations as non-stationary processes. Signals originating from the different sources of emission are treated as simultaneously existing random processes. Thus, the radiometer output is a series of samples obtained from these random processes. The samples are treated as random variables but because the underlying processes are non-stationary the statistics of the samples are treated as non-stationary. The statistics of the calibration samples depend upon the time for which the samples are to be applied. The statistics of the random variables are equated to the mean statistics of the non-stationary processes over the interval defined by the time of calibration sample and when it is applied. This analysis opens the opportunity for experimental investigation into the underlying properties of receiver non stationarity through the use of multiple calibration references. In this presentation we will discuss the application of LSR to the analysis of various calibration algorithms, requirements for experimental verification of the theory, and preliminary results from analyzing experiment measurements.

Racette, Paul↗

On the Use of Deep Convective Clouds to Calibrate AVHRR Data

Remote sensing of cloud and radiation properties from National Oceanic and Atmospheric Administration (NOAA) Advanced Very High Resolution Radiometer (AVHRR) satellites requires constant monitoring of the visible sensors. NOAA satellites do not have onboard visible calibration and need to be calibrated vicariously in order to determine the calibration and the degradation rate. Deep convective clouds are extremely bright and cold, are at the tropopause, have nearly a Lambertian reflectance, and provide predictable albedos. The use of deep convective clouds as calibration targets is developed into a calibration technique and applied to NOAA-16 and NOAA-17. The technique computes the relative gain drift over the life-span of the satellite. This technique is validated by comparing the gain drifts derived from inter-calibration of coincident AVHRR and Moderate-Resolution Imaging Spectroradiometer (MODIS) radiances. A ray-matched technique, which uses collocated, coincident, and co-angled pixel satellite radiance pairs is used to intercalibrate MODIS and AVHRR. The deep convective cloud calibration technique was found to be independent of solar zenith angle, by using well calibrated Visible Infrared Scanner (VIRS) radiances onboard the Tropical Rainfall Measuring Mission (TRMM) satellite, which precesses through all solar zenith angles in 23 days.

Doelling, David R.↗

Automated Attitude Sensor Calibration: Progress and Plans

This paper describes ongoing work a NASA/Goddard Space Flight Center to improve the quality of spacecraft attitude sensor calibration and reduce costs by automating parts of the calibration process. The new calibration software can autonomously preview data quality over a given time span, select a subset of the data for processing, perform the requested calibration, and output a report. This level of automation is currently being implemented for two specific applications: inertial reference unit (IRU) calibration and sensor alignment calibration. The IRU calibration utility makes use of a sequential version of the Davenport algorithm. This utility has been successfully tested with simulated and actual flight data. The alignment calibration is still in the early testing stage. Both utilities will be incorporated into the institutional attitude ground support system.

Sedlak, Joseph↗

The Optical Field Angle Distortion Calibration of HST Fine Guidance Sensors 1R and 3

To date five OFAD (Optical Field Angle Distortion) calibrations have been performed with a star field in M35, four on FGS3 and one on FGS1, all analyzed by the Astrometry Science Team. We have recently completed an improved FGS1R OFAD calibration. The ongoing Long Term Stability Tests have also been analyzed and incorporated into these calibrations, which are time-dependent due to on-orbit changes in the FGS. Descriptions of these tests and the results of our OFAD modeling are given. Because all OFAD calibrations use the same star field, we calibrate FGS 1 and FGS 3 simultaneously. This increases the precision of our input catalog,resulting in an improvement in both the FGS 1 and FGS 3 calibrations. A redetermination of the proper motions,using 12 years of HST data has significantly improved our calibration. Residuals to our OFAD modeling indicate that FGS 1 will provide astrometry superior to FGS 3 by approx. 20%. Past and future FGS astrometric science supported by these calibrations is briefly reviewed.

McArthur, B.↗

Summary of Terra and Aqua MODIS On-orbit Calibration and Characterization Results

The Moderate Resolution Imaging Spectroradiometer (MODIS) onboard NASA's EOS Terra spacecraft has been in operation for more than seven years since its launch in December 1999 and the MODIS onboard Aqua spacecraft has been in operation for more than 4.5 years since its launch in May 2002. Compared to its heritage sensors, such as AVHRR, CZCS, SeaWiFS, HIRS, and Landsat TM, the MODIS instrument was developed with improved spectral and spatial resolutions, and temporal scale or global coverage frequency. The two MODIS instruments are nearly identical with each collecting data in 36 spectral bands: 20 reflective solar bands (RSB) with center wavelengths from 0.41 to 2.2jm and 16 thermal emissive bands (TEB) from 3.7 to 4.4 microns. MODIS makes the Earth view observations with a scan angle range of +/-55 degree relative to instrument nadir and at three nadir spatial resolutions: 0.25km for bands 1-2.05km for bands 3-7, and 1km for bands 8-36, thus enabling complete global coverage of the Earth in less than 2 days. Both Terra and Aqua MODIS observations have been routinely used to generate a broad range of science data products that are widely distributed and extensively applied for the studies of the Earth's land, oceans, and atmosphere and for the monitoring of climate and environmental changes. It is obvious that the MODIS science data product quality strongly relies on sensor on-orbit performance and its capability of continuously tracking sensor response changes over time. Because of this, each MODIS was built with a comprehensive set of on-board calibrators (OBC) that include a solar diffuser (SD) for the RSB calibration, a blackbody (BB) for the TEB calibration, and a spectro-radiometric calibration assembly (SRCA) for the spatial (RSB and TEB) and spectral (RSB only) characterization. Most importantly, extensive and dedicated sensor calibration and characterization efforts have been constantly made by the MODIS Characterization Support Team (MCST) at NASA/GSFC. In this presentation, we will provide an overview of MODIS sensor operations since 1aunh and the onorbit calibration and characterization methodologies with emphasis on the differences between Terra and Aqua MODIS characteristics. We will summarize both Terra and Aqua MODIS onorbit calibration and characterization results, including their RSB and TEB detector noise characterization, the sensor response changes, and the corrections to the optics degradation. In addition to radiometric calibration performance, we will illustrate both sensors' spectral and spatial characterization results in terms of their band-to-band registrations and spectral band center wavelength shifts.

Xiong, X.↗

Sensor On-orbit Calibration and Characterization Using Spacecraft Maneuvers

Spacecraft flight operations often require activities that involve different kinds of maneuvers for orbital adjustments (pitch, yaw, and roll). Different maneuvers, when properly planned and scheduled, can also be applied to support and/or to perform on-board sensor calibration and characterization. This paper uses MODIS (Moderate Resolution Imaging Spectroradiometer) as an example to illustrate applications of spacecraft maneuvers for Earth-observing sensors on-orbit calibration and characterization. MODIS is one of the key instruments for NASA's Earth Observing System (EOS) currently operated on-board the EOS Terra and Aqua spacecraft launched in December 1999 and May 2002, respectively. Since their launch, both Terra and Aqua spacecraft have made a number of maneuvers, specially the yaw and roll maneuvers, to support the MODIS on-orbit calibration and characterization. For both Terra and Aqua MODIS, near-monthly spacecraft roll maneuvers are executed for lunar observations. These maneuvers are carefully scheduled so that the lunar phase angles are nearly identical for each sensor's lunar observations. The lunar observations are used to track MODIS reflective solar bands (RSB) calibration stability and to inter-compare Terra and Aqua MODIS RSB calibration consistency. To date, two sets of yaw maneuvers (each consists of two series of 8 consecutive yaws) by the Terra spacecraft and one set by the Aqua spacecraft have been performed to validate MODIS solar diffuser (SD) bi-directional reflectance factor (BRF) and to derive SD screen transmission. Terra spacecraft pitch maneuvers, first made on March 26, 2003 and the second on April 14, 2003 (with the Moon in the spacecraft nadir view), have been applied to characterize MODIS thermal emissive bands (TEB) response versus scan angle (RVS). This is particularly important since the pre-launch TEB RSV measurements made by the sensor vendor were not successful. Terra MODIS TEB RVS obtained from pitch maneuvers have been used in the current LIB calibration algorithm. Lunq observations from pitch maneuvers also provided information to cross-calibrate MODIS with other sensors (MISR and ASTER) on the same platform. We will provide a summary of MODIS maneuver activities and their applications for MODIS calibration and characterization. The results and lessons learned discussed in this paper from MODIS maneuver activities will provide useful insights into future spacecraft and sensor operation.

Xiong, X.↗