Search NASA⌕ Search

SEARCH · Search NASA

Results for “CESIUM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

The cesium bombardment engine north-south stationkeeping experiment on ATS-6

Two one millipound-thrust cesium bombardment ion thrusters have been developed and integrated on the ATS-F spacecraft for the purpose of demonstrating compatible north-south stationkeeping of a synchronous communication satellite. Preliminary operation of the two thrusters on ATS-6 was completely successful on the first run of each. In addition to verifying operation, the principal accomplishments were the demonstration of a total absence of interference with the communications systems, verification of the predicted spacecraft operating potential, demonstration of compatibility with the star tracker, and demonstration of spacecraft attitude by thrust vectoring. Subsequent attempts to operate the thrusters have not been successful. Analysis indicates that the problem is associated with operation of the propellant reservoirs in zero-g.

Worlock, R. M.↗

The cesium bombardment engine north-south stationkeeping experiment on ATS-6

Two one-millipound-thrust cesium-bombardment ion thrusters have been developed and integrated on the ATS-F spacecraft for the purpose of demonstrating compatible north-south stationkeeping of a synchronous communication satellite. In addition to the two flight units, an identical system is undergoing extended testing on the ground to demonstrate operating lifetime. On July 17, 1974, approximately 50 days after launch, preliminary operation of one of the thrusters was begun. Completely successful operation was achieved on the first run. In addition to verifying operation, the principal accomplishments were the demonstration of a total absence of interference with the complete array of spacecraft-to-ground communication links and the verification of the predicted spacecraft operating potential of approximately -10 volts. Subsequent attempts to operate the same thruster have not been successful and an investigation of possible explanations is underway.

Hunter, R. E.↗

Demonstration of the frequency offset errors introduced by an incorrect setting of the Zeeman/magnetic field adjustment on the cesium beam frequency standard

The fine frequency setting of a cesium beam frequency standard is accomplished by adjusting the C field control with the appropriate Zeeman frequency applied to the harmonic generator. A novice operator in the field, even when using the correct Zeeman frequency input, may mistakenly set the C field to any one of seven major Beam I peaks (fingers) represented by the Ramsey curve. This can result in frequency offset errors of as much as 2.5 parts in ten to the tenth. The effects of maladjustment are demonstrated and suggestions are discussed on how to avoid the subtle traps associated with C field adjustments.

Kaufmann, D. C.↗

ATS-6 - Cesium bombardment engine north-south stationkeeping experiment

Two 0.004 N thrust cesium bombardment ion thrustors have been developed and used for north-south stationkeeping in the geostationary Applications Technology Satellite-6 (ATS-6). The thrustor subsystems are mounted on the north and south faces of the earth viewing module such that 0.0026 N of thrust is applied normal to the orbit plane and 0.0036 N is applied radially upward. The change in the orbit inclination of the satellite is maintained at zero by operating the two thrustors alternately so that their thrust components, normal to the orbital plane, are symmetrically applied about the nodal crossings. Initial operation of the thrustors was successful. There was no interference with the satellite communications systems and the predicted spacecraft operating potential was verified. Subsequent trials failed due to a defect in the operation of the propellant reservoirs in zero g. A feed line valve is under development to correct this difficulty.

Worlock, R. M.↗

Cesium oscillator strengths measured with a multiple-path-length absorption cell

Absorption-oscillator-strength measurements for the principal series in cesium were measured using a multiple-path-length cell. The optical arrangement included a movable transverse path for checking the uniformity of the alkali density along the length of the cell and which also allowed strength measurements to be made simultaneously on both strong and weak lines. The strengths measured on the first 10 doublets indicate an increasing trend in the doublet ratio. The individual line strengths are in close agreement with the high resolution measurements of Pichler (1974) and with the calculations of Norcross (1973).

Exton, R. J.↗

Closed cycle MHD power generation experiments using a helium-cesium working fluid in the NASA Lewis Facility

The MHD channel in the NASA Lewis Research Center was redesigned and used in closed cycle power generation experiments with a helium-cesium working fluid. The cross sectional dimensions of the channel were reduced to 5 by 16.5 cm to allow operation over a variety of conditions. Experiments have been run at temperatures of 1900-2100 K and Mach numbers from 0.3 to 0.55 in argon and 0.2 in helium. Improvements in Hall voltage isolation and seed vaporization techniques have resulted in significant improvements in performance. Typical values obtained with helium are Faraday open circuit voltage 141 V (92% of uBh) at a magnetic field strength of 1.7 T, power outputs of 2.2 kw for tests with 28 electrodes and 2.1 kw for tests with 17 electrodes. Power densities of 0.6 MW/cu m and Hall fields of about 1100 V/m were obtained in the tests with 17 electrodes, representing a factor of 18 improvement over previously reported results. The V-I curves and current distribution data indicate that while near ideal equilibrium performance is obtained under some conditions, no nonequilibrium power has been generated to date.

Sovie, R. J.↗

Results of closed cycle MHD power generation test with a helium-cesium working fluid

The cross sectional dimensions of the MHD channel in the NASA Lewis closed loop facility were reduced to 3.8 x 11.4 cm. Tests were run in this channel using a helium-cesium working fluid at stagnation pressures of 160,000 n/M2, stagnation temperatures of 2000-2060 K and an entrance Mach number of 0.36. In these tests Faraday open circuit voltages of 200 V were measured which correspond to a Faraday field of 1750 V/M. Power generation tests were run for different groups of electrode configurations and channel lengths. Hall fields up to 1450 V/M were generated. Power extraction per electrode of 183 W and power densities of 1.7 MW/M3 were obtained. A total power output of 2 kW was generated for tests with 14 electrodes. The power densities obtained in this channel represent a factor of 3 improvement over those previously reported for the M = 0.2 channel.

Sovie, R. J.↗

Results of closed cycle MHD power generation tests with a helium-cesium working fluid

The cross-sectional dimensions of the MHD channel in the NASA Lewis closed loop facility have been reduced to 3.8 x 11.4 cm. Tests were run in this channel using a helium-cesium working fluid at stagnation pressures of 1.6 x 10 to the 5th N/sq m, stagnation temperatures of 2000-2060 K and an entrance Mach number of 0.36. In these tests Faraday open circuit voltages of 200 V were measured which correspond to a Faraday field of 1750 V/m. Power generation tests were run for different groups of electrode configurations and channel lengths. Hall fields up to 1450 V/m were generated. Power extraction per electrode of 183 W and power densities of 1.7 MW/cu m have been obtained. A total power output of 2 kW was generated for tests with 14 electrodes. The power densities obtained in this channel represent a factor of 3 improvement over those reported for the m = 0.2 channel at the last EAM Symposium.

Sovie, R. J.↗

Electron emission from nickel-alloy surfaces in cesium vapor

The cesiated electron emission was measured for three candidate electrodes for use as collectors in thermionic converters. Nickel, Inconel 600 and Hastelloy were tested with a 412 K cesium reservoir. Peak emission from the alloys was found to be comparable to that from pure nickel. Both the Inconel and the Hastelloy samples had work functions of 1.64 eV at peak emission. The minimum work functions were estimated to be 1.37 eV at a probe temperature of 750 K for Inconel and 1.40 eV for Hastelloy at 665 K. The bare work function for both alloys is estimated to be approximately the same as for pure nickel, 4.8 eV.

Manda, M.↗

A cesium plasma TELEC device for conversion of laser radiation to electric power

Tests of the thermoelectronic laser energy converter (TELEC) concept are reported. This device has been devised as a means to convert high-average-power laser radiation into electrical energy, a crucial element in any space laser power transmission scheme using the available high-power/efficiency infrared lasers. Theoretical calculations, based upon inverse bremsstrahlung absorption in a cesium plasma, indicate internal conversion efficiency up to 50% with an overall system efficiency of 42%. The experiments reported were made with a test cell designed to confirm the theoretical model rather than demonstrate efficiency; 10.6-micron laser-beam absorption was limited to about 0.001 of the incident beam by the short absorption region. Nevertheless, confirmatory results were obtained, and the conversion of absorbed radiation to electric power is estimated to be near 10%.

Britt, E. J.↗

Negative and positive cesium ion studies

Mass spectrometric analyses have been performed on the positive and negative species from discharges in Cs, He-Cs, and He-H2-Cs mixtures. Sampling was conducted through the electrodes of normal glow discharges and from close-spaced heated-cathode conditions, which approximate a cesium thermionic converter. No negative Cs ions were observed for Cs pressures less than .01 torr. Identified species included Cs(+), Cs2(+), Cs(-), and what appeared to be multiply charged ions. Low-mass negative and positive ions attributed to H2 were observed when an He-H2 mixture was also present in the discharge region.

Kuehn, D. G.↗

A cesium TELEC experiment at Lewis Research Center

The thermoelectronic laser energy converter (TELEC), was studied as a method of converting a 10.6 mm CO2 laser beam into electric power. The calculated characteristics of a TELEC seem to be well matched to the requirements of a spacecraft laser energy conversion system. The TELEC is a high power density plasma device which absorbs an intense laser beam by inverse bremsstrahlung with the plasma electrons. In the TELEC process, electromagnetic radiation is absorbed directly in the plasma electrons producing a high electron temperature. The energetic electrons diffuse out of the plasma striking two electrodes which are in contact with the plasma at the boundaries. These two electrodes have different areas: the larger one is designated as the collector, the smaller one is designated as the emitter. The smaller electrode functions as an electron emitter to provide continuity of the current. Waste heat is rejected from the collector electrode. An experiment was carried out with a high power laser using a cesium vapor TELEC cell with 30 cm active length. Laser supported plasma was produced in the TELEC device during a number of laser runs over a period of several days. Electric power from the TELEC was observed with currents in the range of several amperes and output potentials of less than 1 volt. The magnitudes of these electric outputs were smaller than anticipated but consistent with the power levels of the laser during this experiment.

Britt, E. J.↗

Field operations with cesium clocks in HF navigation systems

Networks of HF phase comparison marine navigation stations employing cesium clocks are discussed. The largest permanent network is in the Gulf of Mexico where some fourteen base stations are continuously active and others are activated as needed. These HF phase comparison systems, which operate on a single transmission path, require a clock on the mobile unit as well. Inventory consists of upwards of 70 clocks from two different manufacturers. The maintenance of this network as an operating system requires a coordinated effort involving clock preparation, clock environment control, station performance monitoring and field service.

Christy, E. H.↗

Cesium standard for satellite application

A Cesium frequency standard that was developed for satellite applications is discussed. It weighs 23 lbs. and uses 23.5 watts of power, achieves a stability of 1 x ten to the minus 13th power/100,000 seconds, and is radiation hardened. To achieve the weight and reliability requirements, both thick and thin film hybrid circuits were utilized. A crystal oscillator is used to improve short-term stability and performance on a moving platform.

Bloch, M. B.↗

Engineering and design properties of thallium-doped sodium iodide and selected properties of sodium-doped cesium iodide

Mechanical and thermal properties, not available in the literature but necessary to structural design, using thallium doped sodium iodide and sodium doped cesium iodide were determined to be coefficient of linear thermal expansion, thermal conductivity, thermal shock resistance, heat capacity, elastic constants, ultimate strengths, creep, hardness, susceptibility to subcritical crack growth, and ingot variation of strength. These properties were measured for single and polycrystalline materials at room temperature.

Forrest, K.↗

Rubidium and cesium frequency standards status and performance on the GPS program

The on-oribt operational performance of the frequency standards on the Global Positioning System (GPS) 1 to 10 NAVSTAR satellites are discussed. The history of the Rb frequency standards showing the improvements incorporated at various stages of the program and the corresponding results are presented. Also presented is the operational history of the NAVSTAR cesium frequency standards. The frequency standards configuration data presented covers the chronology of events from the concept validation satellites, NAVSTAR 1 to 10, starting in 1978 to the present, including the configurations of clocks to be used on the GPS Production Program. Data are presented showing the results of long-term laboratory testing of a production Rb frequency standard with the necessary data taken to calculate Delta F, drift, time error, and Allan variance.

Bethke, H.↗

Theoretical studies of Resonance Enhanced Stimulated Raman Scattering (RESRS) of frequency doubled Alexandrite laser wavelengths in cesium vapor

This work focused on understanding the effects of arbitrary transverse and longitudinal relaxation rates on the susceptibilities of coherently driven three-level systems. The approximation of a single relaxation rate often made in previous work is strongly invalidated by the variation in the spontaneous emission lifetime between various atomic level pairs in systems such as cesium. It is of great importance to the problem of nonlinear infrared generation to determine the dependence of both real and imaginary susceptibility on relaxation rates. The imaginary susceptibility on the pump transition determines the absorption of pump photons and the imaginary susceptibility on the laser transition determines the spectral dependence of the gain. This is of particular importance for pure Raman emission (i.e., absorption at linecenter of the gain transition) as it determines the tunability characteristics we are aiming to predict. The real susceptibility is important when cavities are used at the signal field as this will determine the loaded resonance of the Raman oscillator. Researchers show that in some cases which result from having different relaxation rates mode splitting may result, allowing more than one frequency to have the same Raman wavelength, possibly resulting in a temporal instability.

Lawandy, N. M.↗