Search NASA⌕ Search

SEARCH · Search NASA

Results for “CHROMATICITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Opinion: Making the Most of Colour Rendition Research

After decades of debate, new methods for characterizing color rendition have been formalized, providing an improved system of tools to aid technology developers and lighting specifiers. Solid-state lighting, previously burdened by legacy measures based on outdated science, is positioned to take advantage of these new tools to provide tailored, efficient lighting that better meets the needs of specific architectural lighting applications. This transition requires new guidance, however, presenting an opportunity for researchers. There are several key methodological considerations specific to experiments investigating color rendition that will help build a base of guidance that can be widely applied. The importance of these ideas mostly stems from new knowledge gained in the last five years, but their origins date back much further. 1.The spectral power distribution must be adequately varied to stress the measure(s) of color rendition being evaluated. Often, this means varying the gamut shape—the pattern of shift across different hues—to probe weaknesses of hue-averaged characterizations, avoiding misleading conclusions resulting from limited variation in the stimuli. 2.Evaluating the role of chromaticity on color quality evaluations requires careful accommodation of chromatic adaptation to prevent a centering bias. Asking for delayed responses may be insufficient if chromaticity changes are apparent to participants, just as side-by-side viewing of different chromaticities may not produce results that can be reliably applied in the field. It is also critical that color rendition and chromaticity conditions are varied independently. 3.The stimulus being viewed is the interaction of light and objects’ spectral reflectances. This interaction should be quantified in order to assess how derived guidelines will apply measures using standardized color sample sets. Although light source characterizations are typically used to model responses, the objects and their presentation may strongly influence evaluations. 4.Context is important. Many factors—some investigated, others hypothesized—can influence subjective evaluations of color quality, including illuminance level, type of scene, object familiarity, color composition, viewing duration, and viewer traits. Although their influence on research results is unavoidable, the effects of these contextual factors must be carefully considered in developing guidance. Appropriate experimental design can often mitigate negative consequences arising from these considerations. At a minimum, it is crucial to understand how each of these considerations can influence experimental outcomes, as well as the interpretation and application of the results in practice. Consulting other experts prior to conducting an experiment can help ensure appropriate, up-to-date research methods will be used, so that the results will be novel and useful—and not rejected during peer review. There is an interesting feedback loop: technology development provides new research tools, which allow for refined research methods and new results that lead to more technology development. It is time to make a concerted, collective effort to improve color rendition research so that the full potential of solid-state lighting and new characterization methods can be realized, ensuring that high-efficiency, high-utility, high-appeal lighting systems become standard.

Royer, Michael P.↗

Cr{sup 6+}-containing phases in the system CaO-Al{sub 2}O{sub 3}-CrO{sub 4}{sup 2-}-H{sub 2}O at 23 Degree-Sign C

Synthesis and investigation of lamellar calcium aluminium hydroxy salts was performed to study the incorporation of chromate ions in the interlayer of lamellar calcium aluminium hydroxy salts. Different AFm-phases (calcium aluminate hydrate with alumina, ferric oxide, mono-anion phase) containing chromate were synthesized. These AFm-phases belong to the group of layered double hydroxides (LDHs). 3CaO{center_dot}Al{sub 2}O{sub 3}{center_dot}CaCrO{sub 4}{center_dot}nH{sub 2}O and C{sub 3}A{center_dot}1/2Ca(OH){sub 2}{center_dot}1/2CaCrO{sub 4}{center_dot}12H{sub 2}O were obtained as pure phases and their different distinct interlayer water contents and properties determined. Solid solution of chromate-containing phases and tetracalcium-aluminate-hydrate (TCAH) were studied. The uptake of chromate into TCAH from solutions was proven. Chromate contents in solution decrease to <0.2 mg/l. - Graphical abstract: Chromate can be incorporated in LDH-phases with compositions like: 3CaO{center_dot}Al{sub 2}O{sub 3}{center_dot}1/2CaCrO{sub 4}{center_dot}1/2Ca(OH){sub 2}{center_dot}nH{sub 2}O, 3CaO{center_dot}Al{sub 2}O{sub 3}{center_dot}CaCrO{sub 4}{center_dot}nH{sub 2}O, 3CaO{center_dot}Al{sub 2}O{sub 3}{center_dot}1/6CaCrO{sub 4}.{center_dot}5/6Ca(OH){sub 2}{center_dot}nH{sub 2}O, 3CaO{center_dot}Al{sub 2}O{sub 3}(0-x)CaCrO{sub 4}(1-x) Ca(OH){sub 2}{center_dot}12H{sub 2}O, (0<x<0.17). Highlights: Black-Right-Pointing-Pointer Solid solutions and properties of 3CaO{center_dot}Al{sub 2}O{sub 3}{center_dot}CaCrO{sub 4}{center_dot}nH{sub 2}O and C{sub 3}A{center_dot}1/2 Ca(OH){sub 2}{center_dot}1/2 CaCrO{sub 4}{center_dot}12 H{sub 2}O are given. Black-Right-Pointing-Pointer Different hydrates of Ca-Al-hydroxysalts (LDH) with chromate-anions synthesized and characterized. Black-Right-Pointing-Pointer Interlayer exchange reaction of 2OH{sup -} and CrO{sub 4}{sup 2-} investigated. Black-Right-Pointing-Pointer Thermal dehydration and change of lattice parameters are given

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Changes in SSL Device Efficiency and Optical Performance Under Accelerated Aging Conditions

Lighting application efficiency (LAE) describes the efficient delivery of light from the light source to the lighted task and is viewed as a new frontier—increasing energy savings with solid-state lighting (SSL) technologies. The framework for LAE that is proposed by the U.S. Department of Energy (DOE) consists of four major elements: light source efficiency, optical delivery efficiency, spectral efficiency, and intensity effectiveness. This report focuses on a sampling of the available SSL products that can be broadly defined as having modified spectral output because the method of spectra modification has a significant impact on light source efficiency and long-term optical delivery and spectral efficiencies. This report focused on the changes in light source, optical delivery, and spectral efficiencies that occur during aging of SSL devices. An accelerated stress test (AST) regiment was developed for the devices under test (DUTs) examined in this report to provide insights into how the performance of SSL devices change with aging. The AST protocols demonstrate that the SSL products discussed in this report often reduce light source efficiency to achieve different spectral characteristics. In addition, aging of the optical components (e.g., lenses, solder masks) in SSL devices can produce increased light absorption, which negatively impacts optical delivery efficiency and light source efficiency. The modified spectral outputs of the selected SSL products discussed in this report come in a variety of form factors and achieve enhanced optical performance by using a variety of methods. All of the products examined in this study use mid-power light-emitting diodes (MP-LEDs), although the number, configuration, phosphor content, and light-emitting diode (LED) pump of the MP-LEDs differ. Product MS-1 is a 60-watt (W) replacement A19 lamp with a hermetically sealed glass globe, which contains an embedded optical filter to absorb green and yellow emissions, thereby creating a “sunlike” modified spectrum. Product MS-2 is a 60-W replacement A19 lamp with 30 MP-LEDs, and it uses a violet LED pump, along with green and red phosphor emissions, to produce a “healthy” spectrum. This spectrum omits blue emissions in an effort to reduce melanopic lux. Product MS-3 is an LED module consisting of 21 MP-LEDs that use a violet LED pump, along with blue, green, and red phosphors, to produce a “sunlike” spectrum. Products MS-4 and MS-5 are both 6-inch (in) downlights that use a manual switching mechanism so that users can select application-specific correlated color temperatures before installation. Products MS-4 and MS-5 both contain two LED primaries (2,700 Kelvin [K] and 5,000 K) for spectral tuning. Product MS-4 contains 12 MP-LEDs for each LED primary, and Product MS-5 contains 10 MP-LEDs for each LED primary. This report summarizes the overall findings from up to 8,000 hours (hrs) of AST on the lamp DUTs (Products MS-1 and MS-2); up to 5,000 hrs of AST on the LED light engine DUTs (Product MS-3); and up to 7,000 hrs of AST on the downlight DUTs (Products MS-4 and MS-5). The AST procedures used in this study included a room temperature operational life (RTOL) test, an operational life test conducted at 45 degrees Celsius (°C; 45OL) test, an operational life test conducted at 75°C (75OL), a wet high-temperature operational life test performed at 65°C and 90% relative humidity (6590), and a wet high-temperature operational life test performed at 75°C and 75% relative humidity (7575). The AST procedures used for Products MS-1 and MS-2 were RTOL, 45OL, and 6590. The AST procedures used for Products MS-3, MS-4, and MS-5 were RTOL, 75OL, and 7575. During the ASTs described herein, separate populations of each product (three DUTs in each population for Products MS-1, MS-2, MS-4, and MS-5; four DUTs in each population for Product MS-3) were subjected to power cycling of 1 hr on and 1 hr off. The key findings from this study include the following. Enhanced optical performance came at the cost of reduced light source efficiency for the lamps and light engines examined in this study. The optical filter used to produce a “sunlike” spectrum for Product MS-1 reduced light source efficiency by 26%, from 113 lumens per watt (lm/W) to 85 lm/W. Products MS-2 and MS-3 that used a violet-pumped LED to achieve “healthy” and “sunlike” enhanced optical performance, respectively, suffered the largest reduction in initial light source efficiency (49 lm/W for Product MS-2 and 68 lm/W for Products MS-3) perhaps because of the use of violet LED as the optical pump. Product MS-2 also had the poorest color fidelity because of undersaturation of blues and oversaturation of greens and yellows. Chromaticity maintenance of the products in this study was generally good, with parametric failure only occurring for one product at one AST condition (i.e., Product MS-3 at 7575). The chromaticity shift for Product MS-3 in 7575 test conditions resulted from reduced emissions of the broad green and red phosphors used to mimic sunlight in the 500–750 nanometer (nm) range. As a result of these phosphor emission losses, chromaticity shifted toward the more stable violet-pumped LED and blue phosphor. Although chromaticity maintenance was acceptable for most products tested, different chromaticity shift mechanisms were observed for temperature and humidity tests compared with temperature alone for Products MS-1, MS-2, and MS-3. For Product MS-1, a relative increase in green emissions was observed with humidity, which may indicate humidity-accelerated degradation of the optical filter at green wavelengths (optical delivery efficiency reduction) or degradation of the emitters in the red region (spectral efficiency reduction). The violet-pumped products (i.e., MS-2 and MS-3) exhibited different chromaticity shift behavior in the temperature-humidity environments, with Product MS-2 shifting generally yellow because of photo-induced oxidation of the plastic globe (i.e., a reduction of optical delivery efficiency) and Product MS-3 shifting toward violet and blue emitters because of faster loss of emission from green and red phosphors (i.e., a reduction in spectral efficiency). Because of an initial drop in power consumption, the light source efficiency of downlights (Products MS-4 and MS-5) increased at RTOL throughout the test duration. The light source efficiency initially increased during 75OL until a decay in luminous flux maintenance (LFM) dominated light source efficiency, whereas the light source efficiency decreased for the entire 7575 test duration. It was found that increasing the ambient environment of an SSL device from 25°C to 75°C decreases the LFM by 2.7 to 5.5, depending on design of the SSL device. Adding humidity to the system (75OL to 7575) was found to decrease LFM by another factor of approximately 3.0. A common location of failure was identified for the downlights (Products MS-4 and MS-5) operated in the 7575 environment. This failure abruptly occurred between 3,000 to 5,000 hrs of testing on the film capacitor of the electromagnetic interference (EMI) filter near the diode bridge for 11 of the 12 downlights. It is likely that this failure was caused by a combination of the high electrical voltage across the capacitor, the location of the capacitor near the heat sources (e.g., transformers, diode bridges, power resistors), and the high stress environment of 7575. Longer test times are needed to fully understand the LFM, luminous efficacy changes, and chromaticity shifts for some of the products. Because of the high reliability, light source efficiency, and spectral tuning capabilities of LEDs, the expectations of LAE for SSL products are greatly increased over traditional lighting products. The data gathered in this report begin to provide an understanding of the tradeoffs that current SSL products undergo when optimizing the different efficiency elements of LAE. As discussed in this report, the findings from the tests conducted show that the optimization of spectral efficiency can come at the cost of initial light source efficiency. Furthermore, the introduction of violet LEDs can promote long-term optical delivery efficiency degradation, and the introduction of optical filters or new phosphors can lead to unwanted spectral efficiency changes because the ratio of phosphor emitters changes with aging. The data presented in this report also identified a common failure location in 6-in downlights. The results regarding long-term behavior of the modified spectra devices studied provide valuable information about changes to the light source, spectral, and optical delivery efficiencies as the devices age. This information can be used to improve future SSL designs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental validation of color rendition specification criteria based on ANSI/IES TM-30-18

An experiment was conducted to examine color preference specification criteria. Twenty-five participants each evaluated 90 lighting scenes in a room filled with objects. The lighting scenes included nine chromaticity groups, each with 10 systematically-varied color rendition conditions designed to meet or not meet previously proposed color preference specification criteria using ANSI/IES TM-30-18 Rf, Rcs,h1, and Rg. The color rendition conditions did not meet the criterion for none, one, two, or all three of these measures. Participants, who chromatically adapted to each chromaticity group, rated the objects’ color appearance on eight-point scales for saturated-dull, normal-shifted, and like-dislike (preference), as well as a binary for acceptable or unacceptable. The findings corroborate past work, but also indicate that color preference criteria could be adjusted slightly to improve performance, with Tier A having Rf = 78, Rg = 95, and -1% = Rcs,h1 = 15%, Tier B having Rf = 74, Rg = 92, and -7% = Rcs,h1 = 19%, and Tier C having Rf = 70, Rg = 89, -12% = Rcs,h1 = 23%. A companion regression analysis shows models based on Rf, Rg, and Rcs,h1 were superior in predicting color preference compared to those using other measures of color rendition.

Royer, Michael P.↗

Multiple interaction points in ghost collisions

The Ghost Collider makes use of unique “ghost” bunches, which are electrically neutral combinations of electrons and positrons within the same RF bucket, eliminates the beam-beam effects typically present at the interaction point (IP) in conventional colliders. This allows for the novel possibility of placing multiple interaction regions in series, achieving additive luminosity without introducing significant disruption. However, to get higher luminosity, the beta functions at the IP reaches millimeter scale, which in turn adds significant chromatic contribution to the collider. Correcting these chromatic effects is essential to maintain beam stability and ensure high luminosity during collider operation. By carefully adjusting the phase advance between two IRs that are placed in series, it becomes possible to cancel chromaticity globally, enabling stable collider operation while preserving high luminosity. In this paper we discuss the design of such IR/IRs to be used in a ghost collider.

Accelerator Physics↗

Durability of Corrosion Protection Coatings for Aluminum

The objectives of this work are to (1) Develop a detailed understanding of the performance characteristics of current chromate conversion coatings utilized in the stockpile, (2) Develop a detailed understanding of the performance characteristics of non-chromate conversion coatings proposed to replace their chromate containing counterparts, (3) Provide an informed assessment of the aforementioned coatings and a recommended course of action for the replacement of chromate containing coatings, and (4) establish subject matter expertise in the area of replacement coatings to provide as a resource to the systems organization. These tasks will be accomplished by performing a battery of traditional corrosion performance tests (in accordance with the relevant MIL specifications governing chemical conversion coatings), combined with more detailed analytical evaluation of the materials. Coatings will be evaluated in the as-received and artificially aged condition. Four different coating systems were evaluated on four different aluminum alloys in FY16. The focus this year was to continue populating the test matrix initiated in previous years, evaluating key coatings in the as received and thermally stressed condition, as compared to the baseline chromate conversion coating (Bonderite (formerly Alodine) 1200S). The non-chromate conversion coatings included Bonderite T 5900, Chemeon TCP-HF, Luster-On Aluminescent, and MacDermid-Enthone Iridite NCP. A second effort that was completed this year was to address a bottleneck that existed for the electrical evaluation of the coatings, assessing their conformance with the MIL specification. An electromechanical test system was assembled and automated, eliminating the need to rely on an already heavily utilized mechanical test system and operator in Materials Mechanics and Tribology.

36 MATERIALS SCIENCE↗

Hexavalent chromium is cytotoxic and genotoxic to hawksbill sea turtle cells

Sea turtles are a charismatic and ancient ocean species and can serve as key indicators for ocean ecosystems, including coral reefs and sea grass beds as well as coastal beaches. Genotoxicity studies in the species are absent, limiting our understanding of the impact of environmental toxicants on sea turtles. Hexavalent chromium (Cr(VI)) is a ubiquitous environmental problem worldwide, and recent studies show it is a global marine pollutant of concern. Thus, we evaluated the cytotoxicity and genotoxicity of soluble and particulate Cr(VI) in hawksbill sea turtle cells. Particulate Cr(VI) was both cytotoxic and genotoxic to sea turtle cells. Concentrations of 0.1, 0.5, 1, and 5 μg/cm{sup 2} lead chromate induced 108, 79, 54, and 7% relative survival, respectively. Additionally, concentrations of 0, 0.1, 0.5, 1, and 5 μg/cm{sup 2} lead chromate induced damage in 4, 10, 15, 26, and 36% of cells and caused 4, 11, 17, 30, and 56 chromosome aberrations in 100 metaphases, respectively. For soluble Cr, concentrations of 0.25, 0.5, 1, 2.5, and 5 μM sodium chromate induced 84, 69, 46, 25, and 3% relative survival, respectively. Sodium chromate induced 3, 9, 9, 14, 21, and 29% of metaphases with damage, and caused 3, 10, 10, 16, 26, and 39 damaged chromosomes in 100 metaphases at concentrations of 0, 0.25, 0.5, 1, 2.5, and 5 μM sodium chromate, respectively. These data suggest that Cr(VI) may be a concern for hawksbill sea turtles and sea turtles in general. - Highlights: • Particulate Cr(VI) is cytotoxic and clastogenic to hawksbill sea turtle cells. • Soluble Cr(VI) is cytotoxic and clastogenic to hawksbill sea turtle cells. • Cr(VI) may be a risk factor for hawksbill sea turtle health.

60 APPLIED LIFE SCIENCES↗

Determining hexavalent chromium transport properties in alkaline nuclear waste using nuclear magnetic resonance spectroscopy

This study focuses on the transport properties of hexavalent chromium, specifically the chromate anion, to improve predictive models and environmental remediation strategies for Cr(VI) migration. Using 53 Cr Nuclear Magnetic Resonance (NMR) spectroscopy, the research quantifies chromate in multicomponent electrolytes replicating nuclear waste conditions at the Hanford Site in Washington State. The consistency of the 53 Cr NMR signal integral with chromate concentration, despite varying matrix compositions, establishes it as a reliable concentration indicator. The transport properties of chromate in an alkaline solution were assessed using relaxation-based measurements via saturation recovery and Carr-Purcell-Meiboom-Gill experiments, determining spin-lattice and spin-spin relaxation times. These measurements, combined with the Bloembergen-Purcell-Pound equation, helped estimate the rotational correlation time and the 53 Cr self-diffusion coefficient using Stokes-Einstein-Debye and Stokes-Einstein equations. Direct measurements were obtained through pulsed field gradient stimulated echo 53 Cr NMR spectroscopy. Monte Carlo simulations further estimated uncertainty propagation. The results enhance comprehension of chromate transport and highlight prospects for identifying transport properties of NMR-active nuclei, traditionally considered unreachable.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Enumeration reduction algorithm for the characterization of multi-primary LED systems

Multi-primary tunable LED lighting systems can generate a vast number of spectral outputs, with the exact number depending on the resolution of the control signal and number of LED primaries. Computing all combinations to identify optimal spectral power distributions (SPDs) with a specified chromaticity would require a tremendous amount of time and computational power. Here, an enumeration reduction (ER) algorithm is described to reduce the computation time by defining a bounding pyramid in the three-dimensional tristimulus space that maps to the circumscribed square of the target region in the chromaticity diagram. This method enables computing only the necessary amount of tristimulus values (and resulting chromaticity coordinates) for SPDs that fall into a user-defined target chromaticity area, reducing computation time by avoiding the need to generate each combination and calculate its chromaticity coordinates. The results show that the proposed ER algorithm can greatly reduce the time – up to 922 times in a series of tests – to determine a set of metamers compared to a full enumeration computation.

47 OTHER INSTRUMENTATION↗

Dying for Good: Virus-Bacterium Biofilm Co-evolution Enhances Environmental Fitness

Commonly used in biotechnology applications, filamentous M13 phage are non-lytic viruses that infect E. coli and other bacteria, with the potential to promote horizontal gene transfer in natural populations with synthetic biology implications for engineering community systems. Using the E. coli strain TG1, we have investigated how a selective pressure involving elevated levels of toxic chromate, mimicking that found in some superfund sites, alters population dynamics following infection with either wild-type M13 phage or an M13-phage encoding a chromate reductase (Gh-ChrR) capable of the reductive immobilization of chromate (ie, M13-phageGh-ChrR). In the absence of a selective pressure, M13-phage infection results in a reduction in bacterial growth rate; in comparison, in the presence of chromate there are substantial increases in both cellular killing and biomass formation following infection of E. coli strain TG1with M13-phageGh-ChrR that is dependent on chromate-reductase activity. These results are discussed in terms of community structures that facilitate lateral gene transfer of beneficial traits that enhance phage replication, infectivity, and stability against environmental change.

59 BASIC BIOLOGICAL SCIENCES↗

ATF2 Summary and Status

The Accelerator Test Facility (ATF) [1] at KEK was originally constructed as a Damping Ring (DR) demonstration facility for the next generation of electron linear colliders. It consists of a 1.3 GeV s-band linac and a 136m circumference damping ring which can routinely generate 1.6 nC electron bunches with very small vertical emittances (<10pm.rad). Completed in December of 2008, a new extraction line and final focus optics was built, this is referred to as ATF2 [2]. The location of ATF in-relation to the KEK site can be seen in Figure 1. ATF is a general-purpose facility for accelerator physics related R and D activities, with approximately 50% of the available beam time currently devoted to the ATF2 program. The ATF2 extraction line (EXT) and final focus system (FFS) extends about 90 meters from the DR extraction point, a sketch of this system can be seen in figure 2, along with the location of key instrumentation. The primary purpose of the ATF2 beam line is to demonstrate a new style of magnetic focusing optics intended for use at future linear colliders, such as ILC or CLIC based on a local chromaticity correction scheme. The primary goal of the collaboration is to demonstrate the ability of this optics to focus an electron beam of similar emittance to the ILC using a FFS of the same design chromaticity. A comparison of some of the ATF2 design parameters with those of the ILC and CLIC are shown in table 1. With the 1.3 GeV beam energy of ATF2, the target spot size to prove the operability of this optics for ILC is 37nm. This is referred to as 'Goal 1'. In addition, Goal 1 requires the demonstration of stable operations with such a beam size at the Interaction Point (IP). 'Goal 2' is to demonstrate nm-level stability with respect to the IP beam monitors, such as is required for stable beam collisions at ILC or CLIC. A further goal is to attempt to increase the chromaticity of the final focus optics, reducing the IP beta functions to a level where the system more closely resembles the CLIC FFS, and also for some of the newly proposed ILC parameters. It is anticipated that the difficulty of successfully tuning the FFS to deliver design IP beam spot sizes scales with the chromaticity of the system. The design of the achromatic focusing system involves fine cancelation of first, second and third order aberrations at the IP. One needs more accurate cancelation the tighter one attempts to focus the beam, also including more higher order terms. By gradually pushing the system to smaller IP beta functions and higher chromaticity we hope to learn what the limits of such a design are when applied practically. This will give confidence in the design philosophy behind future high-luminosity colliders and in the simulations used to predict their behaviour.

43 PARTICLE ACCELERATORS↗

Bifunctional Ionic Covalent Organic Networks for Enhanced Simultaneous Removal of Chromium(VI) and Arsenic(V) Oxoanions via Synergetic Ion Exchange and Redox Process

Chromium (VI) and arsenic (V) oxoanions are major toxic heavy metal pollutants in water threatening both human health and environmental safety. Here, the development is reported of a bifunctional ionic covalent organic network (iCON) with integrated guanidinium and phenol units to simultaneously sequester chromate and arsenate in water via a synergistic ion-exchange-redox process. The guanidinium groups facilitate the ion-exchange-based adsorption of chromate and arsenate at neutral pH with fast kinetics and high uptake capacity, whereas the integrated phenol motifs mediate the Cr(VI)/Cr(III) redox process that immobilizes chromate and promotes the adsorption of arsenate via the formation of Cr(III)-As(V) cluster/complex. The synergistic ion-exchange-redox approach not only pushes high adsorption efficiency for both chromate and arsenate but also upholds a balanced Cr/As uptake ratio regardless of the change in concentration and the presence of interfering oxoanions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exposure to particulate hexavalent chromium exacerbates allergic asthma pathology

Airborne hexavalent chromate, Cr(VI), has been identified by the Environmental Protection Agency as a possible health threat in urban areas, due to the carcinogenic potential of some of its forms. Particulate chromates are produced in many different industrial settings, with high levels of aerosolized forms historically documented. Along with an increased risk of lung cancer, a high incidence of allergic asthma has been reported in workers exposed to certain inhaled particulate Cr(VI) compounds. However, a direct causal association between Cr(VI) and allergic asthma has not been established. We recently showed that inhaled particulate Cr(VI) induces an innate neutrophilic inflammatory response in BALB/c mice. In the current studies we investigated how the inflammation induced by inhaled particulate Cr(VI) might alter the pathology of an allergic asthmatic response. We used a well-established mouse model of allergic asthma. Groups of ovalbumin protein (OVA)-primed mice were challenged either with OVA alone, or with a combination of OVA and particulate zinc chromate, and various parameters associated with asthmatic responses were measured. Co-exposure to particulate Cr(VI) and OVA mediated a mixed form of asthma in which both eosinophils and neutrophils are present in airways, tissue pathology is markedly exacerbated, and airway hyperresponsiveness is significantly increased. Taken together these findings suggest that inhalation of particulate forms of Cr(VI) may augment the severity of ongoing allergic asthma, as well as alter its phenotype. Such findings may have implications for asthmatics in settings in which airborne particulate Cr(VI) compounds are present at high levels. -- Highlights: ► Allergic asthma correlated with exposure to certain inhaled particulate chromates. ► Direct causal association between Cr(VI) and allergic asthma not established. ► Cr exacerbated pathology and airway hyperresponsiveness in an OVA-challenged mouse. ► Particulate Cr(VI) may augment severity and alter phenotype of ongoing allergic asthma.

60 APPLIED LIFE SCIENCES↗

Hexavalent chromium induces chromosome instability in human urothelial cells

Numerous metals are well-known human bladder carcinogens. Despite the significant occupational and public health concern of metals and bladder cancer, the carcinogenic mechanisms remain largely unknown. Chromium, in particular, is a metal of concern as incidences of bladder cancer have been found elevated in chromate workers, and there is an increasing concern for patients with metal hip implants. However, the impact of hexavalent chromium (Cr(VI)) on bladder cells has not been studied. We compared chromate toxicity in two bladder cell lines; primary human urothelial cells and hTERT-immortalized human urothelial cells. Cr(VI) induced a concentration- and time-dependent increase in chromosome damage in both cell lines, with the hTERT-immortalized cells exhibiting more chromosome damage than the primary cells. Chronic exposure to Cr(VI) also induced a concentration-dependent increase in aneuploid metaphases in both cell lines which was not observed after a 24 h exposure. Aneuploidy induction was higher in the hTERT-immortalized cells. When we correct for uptake, Cr(VI) induces a similar amount of chromosome damage and aneuploidy suggesting that the differences in Cr(VI) sensitivity between the two cells lines were due to differences in uptake. The increase in chromosome instability after chronic chromate treatment suggests this may be a mechanism for chromate-induced bladder cancer, specifically, and may be a mechanism for metal-induced bladder cancer, in general. - Highlights: • Hexavalent chromium is genotoxic to human urothelial cells. • Hexavalent chromium induces aneuploidy in human urothelial cells. • hTERT-immortalized human urothelial cells model the effects seen in primary urothelial cells. • Hexavalent chromium has a strong likelihood of being carcinogenic for bladder tissue.

60 APPLIED LIFE SCIENCES↗

Synthesis, characterization, and crystal structures of uranyl compounds containing mixed chromium oxidation states

The mixed-valence chromium uranyl compounds Li{sub 5}[(UO{sub 2}){sub 4}(Cr(V)O{sub 5})(Cr(VI)O{sub 4}){sub 4}](H{sub 2}O){sub 17} (1), (Mg(H{sub 2}O){sub 6}){sub 5}[(UO{sub 2}){sub 8}(Cr(V)O{sub 5}){sub 2}(Cr(VI)O{sub 4}){sub 8}] (2) and (NH{sub 4}){sub 5}[(UO{sub 2}){sub 4}(Cr(V)O{sub 5})(Cr(VI)O{sub 4}){sub 2}]H{sub 2}O{sub 11} (3) have been synthesized and characterized. Each contains an identical sheet of cation-centered polyhedra. Central to the connectivity of the sheet are four uranyl pentagonal bipyramids that share some of their equatorial vertices, giving a four-membered ring. The Cr(V) cation located near the center of this ring is coordinated by O atoms in a square pyramidal arrangement. The Cr(VI) is tetrahedrally coordinated by O atoms, and these tetrahedra link the four-membered rings of bipyramids. The mixed-valence nature of the sheet was verified by XANES, an EPR spectrum, and bond-valence analysis. Low-valence cations and H{sub 2}O groups reside between the sheets of uranyl and chromate polyhedra, where they provide linkages between adjacent sheets. - Graphical abstract: Three uranyl chromate compounds contain both pentavalent and hexavalent chromium. The unusual topology of the uranyl chromate sheet contains unusual pentavalent chromium in a square pyramidal coordination environment. Highlights: Black-Right-Pointing-Pointer The first uranyl compounds with mixed Cr valences are reported. Black-Right-Pointing-Pointer A sheet of uranyl polyhedra stabilizes pentavalent chromium. Black-Right-Pointing-Pointer Uranyl and chromate polyhedra form a topologically novel sheet.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synthesis and photoluminescence of (Y{sub 0.9−x}La{sub x})Eu{sub 0.1}VO{sub 4} nano-crystal phosphors using a sol–gel method

Graphical abstract: Emission spectra and CIE chromaticity diagram of the (Y{sub 0.9−x}La{sub x})Eu{sub 0.1}VO{sub 4} phosphor. - Highlights: • The CIE chromaticity of (Y{sub 0.75}La{sub 0.15})Eu{sub 0.1}VO{sub 4} phosphor is (0.66, 0.34). • The D{sub 0} → {sup 7}F{sub 2} transition intensity increases about five times for the 15 mol% of La{sup 3+} ion doping. • The (Y{sub 0.75}La{sub 0.15})Eu{sub 0.1}VO{sub 4} may be suitable for use as a UV-LED converted phosphor. - Abstract: The (La, Eu) co-doped YVO{sub 4} with nano-crystal phosphors were prepared using a sol–gel method. The X-ray diffraction profiles show that all of the peaks are attributed to the YVO{sub 4} phase when co-doped with the (La{sup 3+}, Eu{sup 3+}) ions. The intensities of the diffraction peaks decreases when the La{sup 3+} ion concentrations increase. In addition, under an excitation of 318 nm, the {sup 5}D{sub 0} → {sup 7}F{sub 2} transition intensity increased with increasing the La{sup 3+} ion concentration, and increased about five with the 15 mol% of La{sup 3+} ion doping. This is caused by the large difference in ion radius between the La{sup 3+} and Y{sup 3+} ions, which leads to a distorted lattice and a local nonuniform strain in the vicinity of the Eu{sup 3+} ions when La{sup 3+} ions substitute Y{sup 3+} ions in the (Y{sub 0.9−x}La{sub x})Eu{sub 0.1}VO{sub 4} system. The bright red emission of the (Y{sub 0.9}Eu{sub 0.1})VO{sub 4} phosphor has the CIE chromaticity coordinates of (0.66, 0.34) with 15 mol% La{sup 3+} ion doping, which is very close to the NTSC system standard red chromaticity coordinates of (0.67, 0.33)

36 MATERIALS SCIENCE↗