Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONNECT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

A Research Testbed for Experimental Connectivity and Automation in Cars

Cyber-physical systems (CPS) are engineered systems in which the computational components and physical components of the system are interdependent and deeply linked. Discovery and development of CPS technologies are changing the way people interact with engineered systems. To demonstrate this point, consider the Global Positioning System (GPS) which revolutionized personal mobility. Its research origins stem from the US Department of Defense in 1973 for military use. By 2000 limitations on civilian consumption of GPS service were lifted. Immediately, personal GPS products were shipped for in-car navigation systems. Soon after, GPS receivers were embedded into mobile phones with the introduction of the Nokia N95 and Apple iPhone for maps and turn-by-turn navigation. With the benefit of hindsight we can see that GPS has become a cornerstone technology of our daily life. Satellite-based navigation has gone from a radical space technology, to a matter of uninteresting availability; it is the typical way that people navigate through roadways now. The combination of the satellite infrastructure, the integration of receiver modules, and powerful maps applications has significantly changed mobility in the 21st century.

42 ENGINEERING↗

Electrifying Connection, Managing Impacts to Transit & the Grid

This brochure describes the potential impacts at scale electrified transportation may have on the grid by analyzing current deployments and provides recommendations onthe available resources or solutions to help stabilize the grid in other regions.

Source record↗

Identifying the connections between grain growth and flux expulsion in low RRR niobium SRF cavities

The SRF community has shown that high temperature annealing can improve the flux expulsion of niobium cavities during cooldown. The required temperature will vary between cavities and different batches of material, typically around 800 C and up to 1000 C. However, for niobium with a low residual resistance ratio (RRR), even 1000 C is not enough to improve its poor flux expulsion. The purpose of this study is to observe the grain growth behavior of low RRR niobium coupons subjected to high temperature annealing to identify the mechanism for improving flux expulsion. We observe that low RRR material experiences less grain growth than high RRR when annealed at the same temperature. We search for the limitations to grain growth in low RRR material and develop a diagnostic based on grain structure to determine the appropriate recipe for good flux expulsion. The results of this study have the potential to unlock a new understanding on SRF materials and enable the next generation of high Q/high gradient surface treatments.

Howard, K. [Chicago U.] (ORCID:0000000325613308)↗

Zero curvature is a necessary and sufficient condition for a spin-orbital decomposition

There has been an extended debate regarding the existence of a spin-orbital decomposition of the angular momentum of photons and other massless particles. It was recently shown that there are both geometric and topological obstructions preventing any such decomposition. Here we show that any geometric connection on a particle’s state space induces a splitting of the angular momentum into two operators. These operators are well-defined angular momentum operators if and only if the connection has zero curvature. Massive particles have two canonical curved connections corresponding to boosts and rotations, respectively. Furthermore, these can be uniquely combined to produce a flat connection, and this gives a novel derivation of the Newton-Wigner position operator and the corresponding spin and orbital angular momenta for relativistic massive particles. When the mass is taken to zero, transverse boosts and rotations degenerate, leaving only a single connection for massless particles. This connection produces a commonly proposed splitting of the massless angular momentum into two operators. However, the connection is not flat, explaining why these operators do not satisfy the angular momentum commutation relations and are thus not true spin and orbital angular momentum operators.

Angular momentum↗

Isolated vesicles in submarine pumice: insights from the 2019 Volcano F eruption, Kingdom of Tonga

No reliable method can distinguish between subaerial and submarine pumice, but recent work shows that highly vesicular (total porosity, φ > 65%) submarine pumice from the 2012 Havre and 2021 Fukutoku Oka-no-Ba eruptions contains abundant isolated porosity (connectivity, C < 0.6). This differs from textural measurements of subaerial pumice with similarly high vesicularities, where high connectivities (C > 0.8) are often measured. To investigate the implications of this under-studied texture for bubble nucleation, growth, and coalescence dynamics at submarine eruptions, we analyze the textural characteristics of rafted pumice clasts from the 2019 submarine eruption of Volcano F, located along the Tonga-Kermadec Arc. We examined clasts collected while floating near the vent (50–200 km) and distally on the shores of Fiji (900 km). Using helium pycnometry and X-ray tomography (XRT), we quantified porosity and connectivity in 45 pumice lapilli, classifying them by vesicle macrotexture and edge morphology. Microvesicular clasts, the majority of which have breadcrust and cauliflower textures, exhibit the lowest connectivities (C = 0.61 ± 0.2), while macrovesicular clasts have high connectivities with C ~ 1. We propose that isolated porosity abundance varies according to clast location in the eruption column post-fragmentation. Microvesicular clasts erupted on the edges of the column and experienced high levels of seawater ingestion and subsequent quenching of the entire clast. Macrovesicular clasts, in contrast, erupted in the center of the eruption column and were thus thermally insulated, allowing magmatic bubbles in the molten pumice to nucleate, grow, and coalesce for longer. Our results and interpretation imply that low connectivity, microvesicular clasts preserve pre and syn-eruptive bubble processes at the 2019 Volcano F eruption.

Permeability↗

Stochastic fracture generation and thermo-hydro-mechanical modeling in an equivalent continuum framework for enhanced geothermal systems

Enhanced geothermal systems (EGS) involve fracturing low permeability material to establish well connectivity and then injecting and circulating fluid into the fractured subsurface for geothermal power production. Changes in fracture aperture from contraction of the cooling matrix rock may alter network connectivity and risk thermal short-circuiting. Thermo-hydro-mechanical (THM) models are a useful tool to study these processes. However, as fracture networks are complex, and data may be limited, fracture networks in THM models are often stochastically generated. Given reliance on stochastic fracture networks and THM modeling to represent the subsurface and assess productivity of EGS, increased understanding of the influence of such statistically derived fracture networks on flow and heat transport in THM models is needed. Here, a new fracture process model is developed in the reactive transport code PFLOTRAN to stochastically generate fracture families and simulate changes in fracture aperture over time due to temperature changes of the rock matrix. Sixty-four different fracture networks ranging from well to poorly-connected, are modeled in PFLOTRAN with and without mechanical processes (THM vs TH). Results indicate that for well-connected fracture networks, thermal short-circuiting is less of a concern due to the abundance of available alternative flowpaths. For poorly-connected fracture networks, inclusion of mechanical processes showed steep thermal drawdown coincident with increase in fracture aperture along developing colder flowpaths, demonstrating the risk of thermal short-circuiting. Simulations with additional, larger fractures engineered to establish connectivity in a poorly-fractured subsurface, indicate that while stochastic variation of fracture orientation of the background network had limited influence, such variation in the engineered fractures significantly affected flow and heat transport.

Discrete fracture networks (DFN)↗

Sizing and Location Selection of Medium‐Voltage Back‐to‐Back Converters for DER‐Dominated Distribution Systems

Medium‐voltage back‐to‐back (MVB2B) converters can connect two distribution systems and quantifiably transfer power between them. This function can enable the MVB2B converter to exchange distributed energy resource (DER)‐generated power between two systems and bring significant value to enhancing distribution system DER adoption. Our previous work analysed and demonstrated the value MVB2B converter can bring to DER integration. As continuous work, this paper presents a methodology that helps address the MVB2B converter sizing and location selection problem in distribution systems with high DER penetrations. The proposed methodology aims to address three critical problems for MVB2B converter implementation in the real world: (1) which distribution systems are better to be connected, (2) what converter size is appropriate for connecting the distribution systems, and (3) where the optimal connection points are in the systems for connecting the MVB2B converter. The proposed methodology has been demonstrated by case studies that include various scenarios involving distribution systems with different dominated load types and high photovoltaic penetrations. The results demonstrate that selecting the optimal converter size based on net revenue and time of return considerations leads to a balance between maximizing energy savings and minimizing financial payback periods. Furthermore, feeder pair selection based on load profile standard deviation effectively identifies systems that derive the greatest value from MVB2B integration. Finally, an optimized connection point selection approach using a voltage load sensitivity matrix ensures minimal system impact while facilitating efficient power exchange. These findings provide practical insights for the real‐world deployment of MVB2B converters to enhance DER hosting capacity and improve grid resilience.

14 SOLAR ENERGY↗

Impact of Different Thermal Gradients on the Dynamics of Cylindrical Lithium-ion Cells Subject to Accelerated Aging and on Module Performance

This study investigates the impacts of applying different thermal gradient patterns to cylindrical lithium-ion cells in a module on cell dynamics (temperatures, current flows, state of charge), module performance (evolution of resistance, capacity, and energy versus cycle number), and module lifetime. The thermal gradients were generated using cooling plates (CPs) with three different flow-field designs, namely, straight, perpendicular, and U-turn. The study uses computational fluid dynamics (CFD), the pseudo-two-dimensional (P2D) battery model, capacity loss and increased impedance due to the growth of a solid-electrolyte-interphase, and the electric current distribution from module terminals to cells that depends on the series-parallel electrical connections among the cells. The impact of the thermal gradient (resulting from the CP designs) on the variability in resistance, current, state of charge, and voltage among the cells was analyzed and linked to differences in the module's performance. Applying a thermal gradient to parallel-connected strings of series-connected cells led to variation in the current through each parallel string and an imbalance in the voltage of series-connected cells. Module performance is poorer when the thermal gradient causes a voltage imbalance than when it causes a current imbalance. Module performance becomes the worst when both current variation and voltage imbalance happen together. For instance, the module's lifetime (estimated as reaching 80% of its initial capacity) varied by 5% to 17.5%, depending on the magnitude and pattern of the imposed thermal gradient. As the relative orientation between thermal gradients and cells' electrical connectivity influences the module's performance, appropriate consideration should be given to the choice of the CP, especially if large thermal gradients are allowed.

Battery thermal management↗

Scaling Arctic landscape and permafrost features improves active layer depth modeling

Tundra ecosystems in the Arctic store up to 40% of global below-ground organic carbon but are exposed to the fastest climate warming on Earth. However, accurately monitoring landscape changes in the Arctic is challenging due to the complex interactions among permafrost, micro-topography, climate, vegetation, and disturbance. This complexity results in high spatiotemporal variability in permafrost distribution and active layer depth (ALD). Moreover, these key tundra processes interact at different scales, and an observational mismatch can limit our understanding of intrinsic connections and dynamics between above and below-ground processes. Consequently, this could limit our ability to model and anticipate how ALD will respond to climate change and disturbances across tundra ecosystems. In this paper, we studied the fine-scale heterogeneity of ALD and its connections with land surface characteristics across spatial and spectral scales using a combination of ground, unoccupied aerial system, airborne, and satellite observations. We showed that airborne sensors such as AVIRIS-NG and medium-resolution satellite Earth observation systems like Sentinel-2 can capture the average ALD at the landscape scale. We found that the best observational scale for ALD modeling is heavily influenced by the vegetation and landform patterns occurring on the landscape. Landscapes characterized by small-scale permafrost features such as polygon tussock tundra require high-resolution observations to capture the intrinsic connections between permafrost and small-scale land surface and disturbance patterns. Conversely, in landscapes dominated by water tracks and shrubs, permafrost features manifest at a larger scale and our model results indicate the best performance at medium resolution (5 m), outperforming both higher (0.4 m) and lower resolution (10 m) models. This transcends our study to show that permafrost response to climate change may vary across dominant ecosystem types, driven by different above- and below-ground connections and the scales at which these connections are happening. We thus recommend tailoring observational scales based on landforms and characteristics for modeling permafrost distribution, thereby mitigating the influences of spatial-scale mismatches and improving the understanding of vegetation and permafrost changes for the Arctic region.

54 ENVIRONMENTAL SCIENCES↗

Entanglement Capacity Estimates and Throughput Measurements of Quantum Channels

The throughput is an important performance metric of entangled qubit distribution quantum networks, and may be characterized by the number of distributed entangled qubit pairs per second (ebps). It is measured over physical quantum network connections using specialized instruments, including photonic entanglement sources and single photon detectors. Extensive theory has been developed to estimate the entangled qubit capacity of quantum channels using abstractions of physical connections. These two quantities both characterize the throughput performance but in different ways, and typically have been hard to relate to each other in concrete terms, in part due to the lack of precise measurements with matching analytical models and derivations. We describe measurements on a physical testbed with fiber connections of lengths 0-75 kilometers. We obtain the normalized analytic capacity estimates using the transmissivity approximations derived using single photon coincidence measurements, and convert them to bounds on throughput (measured in ebps) using a multiplier derived from co-located detector measurements. The results indicate consistent throughput measurements upper-bounded by their analytical capacity estimates across all connections. We show that previous capacity estimates using light measurements are below ebps measurements for some connections, due to the inclusion of non-representative decrease of light levels outside C-band with distance.

Rao, Nageswara↗

Design, Control, and Protection of a 13.2 kV, 1 MVA Solid State Transformer for Electric Vehicle Extreme Fast Charging Station

In this article, a medium-voltage (MV) ac-dc solid state transformer (SST) for electric vehicle (EV) extreme fast charging (XFC) station is proposed. The SST adopts a cascaded H-bridge (CHB)-based structure where the active front end (AFE) power stages are connected in input-series followed by dual active bridge (DAB) converters connected in an output-parallel configuration providing galvanic isolation through a high-frequency transformer (HFT). The SST is rated for 1 MVA and connects directly to a three-phase 13.2 kV MV ac grid through ac switchgear and outputs 750-V dc. At the dc bus, several dc/dc converters are connected, each of which can charge an EV based on its battery capacity. A novel decentralized control architecture of the SST is adopted in this work which simplifies the MV dc link voltage and module-level power balancing. In addition, the local and central protection designs of the SST are presented which identify and respond to the internal fault of the system. Finally, the experimental validations of the SST hardware prototype are presented up to the rated voltage. Furthermore, this article details the design and implementation of the MV SST addressing the challenges of an isolated MV class power converter for connecting directly to the MV ac grid with unique controller architecture, distributed protection framework, and SST constructional features.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Database Performance Monitoring for DUNE

This report presents the research, design, and implementation of improved PostgreSQL monitoring for DUNE Rucio database services using Checkmk. The project began with a request to improve dashboard visibility for database performance metrics, including connection usage, configured connection limits, lock activity, wait behavior, storage trends, query performance, and saturation alerts. The initial implementation focused on the dune_rucio_prod database on the rucio_prod PostgreSQL instance because connection saturation and lock contention are direct reliability risks for database-backed services. Existing Checkmk PostgreSQL monitoring was investigated, and several gaps were identified. Built-in connection monitoring did not clearly separate active, idle, idle-in-transaction, total, and usage-percent metrics, while the built-in lock monitoring simplified PostgreSQL lock modes into shared and exclusive categories. To address these gaps, two DSG-specific Checkmk local checks were created: one for connection-state monitoring and one for lock-state monitoring. These checks supplement the built-in PostgreSQL checks and provide additional performance data for dashboard graphs, service states, and alerts.

Bowers, Elliot [Cabrillo Coll.]↗

Diagenesis is key to unlocking outcrop fracture data suitable for quantitative extrapolation to geothermal targets

Exceptionally large, well-exposed sandstone outcrops in New York provide insights into folds, deformation bands, and fractures that could influence permeability, heat exchange, and stimulation outcomes of geothermal reservoir targets. Cambrian Potsdam Sandstone with <5% porosity contains decimeter-scale open, angular-limbed monoclines <0.5 km apart with associated low-porosity mm-wide cataclastic deformation bands. Crossing and abutting relationships among sub-vertical opening-mode fractures show four chronological Sets A–D, striking NNW, NE, NW, and ENE, respectively. Fracture lengths and heights range from millimeters to tens of meters. Sets A and C macro-fractures, and possibly B and D, contain quartz deposits. All sets have abundant associated quartz cemented microfractures that also record set orientations and crosscutting relations. Quartz cement deposits—evidence of diagenesis—are the key to identifying attributes of outcrop fractures suitable for extrapolation to geothermal targets in sandstones because they show which fractures formed in the subsurface. Set A fluid inclusion homogenization temperatures (120°C–129°C) are compatible with fracture at >3 km depth. Fractures are stiff and those ≥0.05 mm (Set C) and ≥0.1 mm (Set A) are open and potentially conducive to flow. Sets A and D are abundant in outcrops with close fracture spacing—0.18 m and 0.68 m, respectively—and define a rectangular connectivity network dominated by crossing and abutting X and Y nodes. Set A aperture distributions follow a power law with slope –0.8 up to 0.15 mm; other sets have lognormal distributions. Set A and D microfractures are weakly clustered, while macro-fractures commonly have 1D anticlustered (regular or periodic) arrangements at shorter length scales (<0.2 m). Sub-horizontal fractures are barren and may have formed near the surface. Fracture heights, lengths, and spatial arrangements show good trace connectivity but low open connectivity. For geothermal applications, outcrop results predict low initial well-test permeabilities owing to quartz disconnecting open fractures, but stimulation of closely spaced microfractures and partly open macro-fractures could yield high surface area for heat exchange. Quantitative extrapolation of key fracture attributes like abundance, orientation, spatial arrangement, length, and open fracture connectivity is possible from outcrops to fractured reservoirs if differing thermal histories and diagenesis are accounted for.

02 PETROLEUM↗

A State-Space Model for Stability Boundary Analysis of Grid-Following Voltage Source Converters Considering Grid Conditions

With the growing significance of renewable energy resources and energy storage systems, the number of grid-connected inverters has been rising at an increasingly rapid pace. Generally, these inverters are directly integrated with the distribution network by synchronizing with the grid voltage at the point of common coupling. However, the low grid strength and varying R/X ratios, as the common characteristics of most distribution networks or weak grids, can lead to dynamic interactions that comprise stability and limit the power transfer capacity of grid-connected inverters. To ensure stable operation of the inverters, researchers must determine the stability boundary, described as the maximum power transfer capacity of grid-connected inverters under the premise of maintaining system small-signal stability. For this purpose, we propose to formulate a state-space model of the system in the synchronously rotating dq-frame of reference and perform eigenvalue analysis to determine the stability boundary. With a detailed model of the control structure and parameters of the grid-connected inverters, the stability boundary is identified as a surface with respect to different grid strengths and R/X ratios. Case study results of proposed eigenvalue analysis are compared with those of admittance model-based stability analysis as well as time-domain simulation using a switching model in Matlab/Simulink, validating the effectiveness and accuracy of the proposed eigenvalue analysis for stability boundary identification.

grid-connected inverters↗

Interface diagnostics platform for thin-film solid-state batteries

Understanding the impedances of battery materials and their interfaces remains a major challenge, usually addressed by electrochemical impedance spectroscopy (EIS) where frequency-dependent complex impedance of full battery cells is measured and then modeled by a network of connected electrical elements. As conventionally applied, this approach produces ambiguity in that (1) multiple different network configurations may fit the data convincingly and (2) the method offers no direct association of the electrical elements with physical features of the battery. Here we present a new methodology that resolves both sources of ambiguity, enabled by expanding the experimental scope to directly inform the configuration of elements and their parameters in the network model. We demonstrate this methodology using thin film fabrication of solid state battery devices patterned by shadow masked sputter deposition, so that diagnostic devices corresponding to individual interface and material components can be fabricated simultaneously with full cell batteries. EIS models for the diagnostic devices can then be connected to form full cell networks whose topology matches the well-known physical configuration of the battery. When connected in this way, the full network model – made from connecting the diagnostic device EIS models – fits the full cell EIS data. For the case of a thin film solid state battery composed of amorphous silicon anode, lithium phosphorus oxynitride (LiPON) solid electrolyte, and lithium vanadium oxide (Li x V 2 O 5 ) cathode, we show that the approach allows us to identify ionic impedance/conductivity of the cathode/electrolyte as a limiting impedance and the anode/electrolyte interface cycling instability as a primary degradation factor.

25 ENERGY STORAGE↗

Dynamic density functional theory of polymers with salt in electric fields

Here we present a dynamic density functional theory for modeling the effects of applied electric fields on the local structure of polymers with added salt (polymer electrolytes). Time-dependent equations for the local electrostatic potential and volume fractions of polymer, cation, and anion of added salt are developed using the principles of linear irreversible thermodynamics. For such a development, a field theoretic description of the free energy of polymer melts doped with salts is used, which captures the effects of local variations in the dielectric function. Connections of the dynamic density functional theory with experiments are established by relating the three phenomenological Onsager’s transport coefficients of the theory to the mutual diffusion of electrolyte, ionic conductivity, and transference number of one of the ions. The theory is connected with a statistical mechanical model developed by Bearman and Kirkwood [J. Chem. Phys. 28, 136 (1958)] after relating the three transport coefficients to friction coefficients. The steady-state limit of the dynamic density functional theory is used to understand the effects of dielectric inhomogeneity on the phase separation in polymer electrolytes. The theory developed here provides not only a way to connect with experiments but also to develop multi-scale models for studying connections between local structure and ion transport in polymer electrolytes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Entanglement Throughput Measurements and Capacity Estimates for Aerial-Inground Fiber

The throughput of entangled qubit pairs per second (eqps) is a basic performance metric of quantum networks that provide the entanglement distribution capability. Over fiber connections, it is measured using specialized instruments, including photonic entanglement sources and single-photon detectors. Extensive theory has been developed to estimate the capacity of a generic quantum channel, which in turn is applied to estimate the maximum achievable eqps over a fiber connection. However, there is a gap in relating these two performance metrics, in part due to their disparate nature, namely, mathematical formulae of the channel capacity and specialized instrumentation for eqps measurements. We describe eqps measurements collected over testbed connections composed of aerial and inground fiber of lengths up to 45 km. We estimate the normalized capacity using the transmissivity parameter derived from single photon detector measurements. These estimates are then converted to capacity bounds on the connection's eqps using the source eqps rate derived from co-located detector measurements. The results indicate a consistency between eqps measurements and their capacity estimates, and provide insights into relating the parameters of analytic capacity estimates to physical measurements.

Rao, Nageswara [ORNL] (ORCID:0000000234085941)↗