Spatiotemporal variations of albedo in managed agricultural landscapes: inferences to global warming impacts (GWI)

Albedo can be used to quantify ecosystem and landscape contributions to local and global climate. Such contributions are conventionally expressed as radiative forcing (RF) and global warming impact (GWI). We contextualize our results within landscape carbon production and storage to highlight the importance of changes in albedo for landscape GWI from multiple causes, including net ecosystem production (NEP) and greenhouse gas (GHG) emissions. Objective To examine the spatiotemporal changes in albedo (Δα) in contrasting managed landscapes through calculations of albedo-induced RF (RF Δα ) and GWI (GWI Δα ) under different climatic conditions. Methods We selected five contrasting landscapes within the Kalamazoo River watershed in southern Michigan USA as proof of concept. The daily MCD43A3 MODIS (V006) product was used to analyze the inter- and intra-annual variations of growing season albedo. In addition, the variations of RF Δα and GWI Δα were computed based on landscape composition and climate. Results The RF Δα (-5.6 W m -2 ) and GWI Δα (-1.3 CO 2eq ha -1 year -1 ) were high in forest-dominated landscapes, indicating cooling effects and CO 2eq mitigation impacts similar to crops. The CO 2eq mitigation of cropland-dominated landscapes was on average 52% stronger than forest-dominated landscapes. In the landscape with the highest proportion of forest, under dry and wet conditions CO 2eq mitigation was reduced by up to 24% and ~ 30%, respectively; in one cropland-dominated landscape wet conditions reduced CO 2eq mitigation by 23%. Conclusions Findings demonstrate that quantifying spatiotemporal changes in albedo in managed landscapes and under different climatic conditions is essential to understand how landscape modification affects RF Δα and GWI Δα and thereby contributes to ecosystem-level GWI.

54 ENVIRONMENTAL SCIENCES↗

Cancer stem cell-like cells from a single cell of oral squamous carcinoma cell lines

Research highlights: {yields} Four oral squamous cancer cell lines (OSCCL) were analyzed for cancer stem cells (CSCs). {yields} Single cell derived colonies of OSCCL express CSC-marker CD133 differentially. {yields} Monoclonal cell lines showed reduced sensitivity for Paclitaxel. {yields} In situ CD133{sup +} cells are slow cycling (Ki67-) indicating a reduced drug sensitivity. {yields} CD133{sup +} and CSC-like cells can be obtained from single colony forming cells of OSCCL. -- Abstract: Resistance of oral squamous cell carcinomas (OSCC) to conventional chemotherapy or radiation therapy might be due to cancer stem cells (CSCs). The development of novel anticancer drugs requires a simple method for the enrichment of CSCs. CSCs can be enriched from OSCC cell lines, for example, after cultivation in serum-free cell culture medium (SFM). In our study, we analyzed four OSCC cell lines for the presence of CSCs. CSC-like cells could not be enriched with SFM. However, cell lines obtained from holoclone colonies showed CSC-like properties such as a reduced rate of cell proliferation and a reduced sensitivity to Paclitaxel in comparison to cells from the parental lineage. Moreover, these cell lines differentially expressed the CSC-marker CD133, which is also upregulated in OSCC tissues. Interestingly, CD133{sup +} cells in OSCC tissues expressed little to no Ki67, the cell proliferation marker that also indicates reduced drug sensitivity. Our study shows a method for the isolation of CSC-like cell lines from OSCC cell lines. These CSC-like cell lines could be new targets for the development of anticancer drugs under in vitro conditions.

60 APPLIED LIFE SCIENCES↗

Survivin Is a Potential Mediator of Prostate Cancer Metastasis

Purpose: We examined whether Survivin expression is associated with an increased risk of metastasis in prostate cancer. Methods and Materials: A total of 205 patients with T1 (23%) and T2 (77%) prostate cancer were treated with conventional external beam radiation therapy from 1991 to 1993 at the Massachusetts General Hospital. Of the patients, 62 had adequate and suitable-stained tumor material for Survivin analysis. Median follow-up was 102 months (range, 5-127 months). Distant failure was determined on the basis of clinical criteria. In preclinical studies, replication-deficient adenovirus encoding phosphorylation-defective Survivin Thr34{yields}Ala dominant-negative mutant pAd-S(T34A) or short hairpin RNA (shRNA) was used to inhibit Survivin in prostate cancer models, and the cell motility, morphology, and metastasis were investigated. Results: Our correlative data on men with early-stage (T1/T2) prostate cancers treated at Massachusetts General Hospital by definitive radiotherapy indicated that overexpression of Survivin (positive staining in {>=}10% cells) was associated with a significantly increased risk for the subsequent development of distant metastasis (p = 0.016) in the univariate analysis. In the multivariate analysis, overexpression of Survivin remained an independent predictor of distant metastasis (p = 0.008). The inhibition of Survivin dramatically inhibited invasiveness of prostate cancer cells in the in vitro invasion assay and spontaneous metastasis in the Dunning prostate cancer in vivo model. Furthermore, attenuation of Survivin resulted in changes in the microtubule cytoskeleton, loss of cellular polarity, and loss of motility. Conclusions: This study suggests that Survivin may be a potentially important prognostic marker and promising therapeutic target in metastatic prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinically Applicable Monte Carlo–based Biological Dose Optimization for the Treatment of Head and Neck Cancers With Spot-Scanning Proton Therapy

Purpose: Our aim is to demonstrate the feasibility of fast Monte Carlo (MC)–based inverse biological planning for the treatment of head and neck tumors in spot-scanning proton therapy. Methods and Materials: Recently, a fast and accurate graphics processor unit (GPU)–based MC simulation of proton transport was developed and used as the dose-calculation engine in a GPU-accelerated intensity modulated proton therapy (IMPT) optimizer. Besides dose, the MC can simultaneously score the dose-averaged linear energy transfer (LET{sub d}), which makes biological dose (BD) optimization possible. To convert from LET{sub d} to BD, a simple linear relation was assumed. By use of this novel optimizer, inverse biological planning was applied to 4 patients, including 2 small and 1 large thyroid tumor targets, as well as 1 glioma case. To create these plans, constraints were placed to maintain the physical dose (PD) within 1.25 times the prescription while maximizing target BD. For comparison, conventional intensity modulated radiation therapy (IMRT) and IMPT plans were also created using Eclipse (Varian Medical Systems) in each case. The same critical-structure PD constraints were used for the IMRT, IMPT, and biologically optimized plans. The BD distributions for the IMPT plans were obtained through MC recalculations. Results: Compared with standard IMPT, the biologically optimal plans for patients with small tumor targets displayed a BD escalation that was around twice the PD increase. Dose sparing to critical structures was improved compared with both IMRT and IMPT. No significant BD increase could be achieved for the large thyroid tumor case and when the presence of critical structures mitigated the contribution of additional fields. The calculation of the biologically optimized plans can be completed in a clinically viable time (<30 minutes) on a small 24-GPU system. Conclusions: By exploiting GPU acceleration, MC-based, biologically optimized plans were created for small–tumor target patients. This optimizer will be used in an upcoming feasibility trial on LET{sub d} painting for radioresistant tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurement and thermal modeling of sapphire substrate temperature at III-Nitride MOVPE conditions

Here, growth rates and alloy composition of AlGaN grown by MOVPE is often very temperature dependent due to the presence of gas-phase parasitic chemical processes. These processes make wafer temperature measurement highly important, but in fact such measurements are very difficult because of substrate transparency in the near- IR (~900 nm) where conventional pyrometers detect radiation. The transparency problem can be solved by using a mid-IR pyrometer operating at a wavelength (~7500 nm) where sapphire is opaque. We employ a mid- IR pyrometer to measure the sapphire wafer temperature and simultaneously a near-IR pyrometer to measure wafer pocket temperature, while varying reactor pressure in both a N 2 and H 2 ambient. Near 1300 °C, as the reactor pressure is lowered from 300 Torr to 10 Torr the wafer temperature drops dramatically, and the ΔT between the pocket and wafer increases from ~20 °C to ~250 °C. Without the mid-IR pyrometer the large wafer temperature change with pressure would not have been noted. In order to explain this behavior we have developed a quasi-2D thermal model that includes a proper accounting of the pressure-dependent thermal contact resistance, and also accounts for sapphire optical transmission. The model and experimental results demonstrate that at most growth conditions the majority of the heat is transported from the wafer pocket to the wafer via gas conduction, in the free molecular flow limit. In this limit gas conductivity is independent of gap size but first order in pressure, and can quantitatively explain results from 20 to 300 Torr. Further analysis yields a measure of the thermal accommodation coefficients; α(H 2 ) =0.23, α(N 2 ) =0.50, which are in the range typically measured.

36 MATERIALS SCIENCE↗

Helical Tomotherapy Delivery of an IMRT Boost in Lieu of Interstitial Brachytherapy in the Setting of Gynecologic Malignancy: Feasibility and Dosimetric Comparison

Interstitial brachytherapy is an important means by which to improve local control in gynecologic malignancy when intracavitary brachytherapy is untenable. Patients unable to receive brachytherapy have traditionally received conventional external beam radiation alone with modest results. We investigated the ability of Tomotherapy (Tomotherapy Inc., Madison, WI) to replace interstitial brachytherapy. Six patients were selected. The planning CT of each patient was contoured with the planning target volume (PTV), bladder, rectum, femoral heads, and bowel. Identical contour sets were exported to Tomotherapy and Nucletron PLATO (Nucletron B.V., Veenendaal, The Netherlands). With Tomotherapy, the PTV was prescribed 31 Gy in 5 fractions to 90% of the volume. With PLATO, 600 cGy x 5 fractions was prescribed to the surface of the PTV. Dose delivered was normalized to 2 Gy fractions (EQD2) and added to a hypothetical homogenous 45-Gy pelvic dose. Tomotherapy achieved a D90 of 87 Gy EQD2 versus 86 Gy with brachytherapy. PTV dose was more homogeneous with tomotherapy. The dose to the most at-risk 2 mL of bladder and rectum with Tomotherapy was of 78 and 71 Gy EQD2 versus 81 and 75 Gy with brachytherapy. Tomotherapy delivered more dose to the femoral heads (mean 1.23 Gy per fraction) and bowel. Tomotherapy was capable of replicating the peripheral dose achieved with brachytherapy, without the PTV hotspots inherent to interstitial brachytherapy. Similar maximum doses to bowel and bladder were achieved with both methods. Excessive small bowel and femoral head toxicity may result if previous pelvic irradiation is not planned accordingly. Significant challenges related to interfraction and intrafraction motion must be overcome if treatment of this nature is to be contemplated.

61 RADIATION PROTECTION AND DOSIMETRY↗

Irradiation-Induced Structural Disorder and Its Influence on the Mechanical Response of Polycrystalline MoS2

Molybdenum disulfide (MoS2) thin films are widely used as dry-film lubricants and protective coatings in aerospace and other radiation-exposed environments. Conventional synthesis routes produce polycrystalline films whose grain boundaries and other native defects cause their mechanical and tribological behavior to differ substantially from that of ideal single crystals. Under irradiation, these films progressively evolve from polycrystalline structures, composed of layered MoS2 grains, into highly disordered and eventually amorphous structures, altering both their tribological performance and mechanical integrity. Here, we employ reactive atomistic simulations to investigate irradiation-driven structural evolution in bulk polycrystalline MoS2. Using controlled primary knock-on atom (PKA) events, we characterize the progressive transition from a polycrystalline microstructure to an amorphous network by tracking defect accumulation and structural disorder. We then establish how this transition modifies the dominant deformation mechanisms and the temperature-dependent tensile response. Specifically, irradiation suppresses interlayer sliding and delamination, mechanisms which facilitate the deformation of the pristine polycrystal, resulting in defect-induced hardening. Broadly, our results establish direct process–structure–property relationships linking irradiation-induced defect accumulation, microstructural evolution, deformation mechanisms, and mechanical behavior, providing an atomistic framework for understanding the structural integrity and long-term reliability of irradiated MoS2 coatings.

Moore, Daniel [Sandia National Laboratories (SNL)]↗

Plasma and cyclotron frequency effects on output power of the plasma wave-pumped free-electron lasers

Significant progress has been made employing plasmas in the free-electron lasers (FELs) interaction region. In this regard, we study the output power and saturation length of the plasma whistler wave-pumped FEL in a magnetized plasma channel. The small wavelength of the whistler wave (in sub-μm range) in plasma allows obtaining higher radiation frequency than conventional wiggler FELs. This configuration has a higher tunability by adjusting the plasma density relative to the conventional ones. A set of coupled nonlinear differential equations is employed which governs on the self-consistent evolution of an electromagnetic wave. The electron bunching process of the whistler-pumped FEL has been investigated numerically. The result reveals that for a long wiggler length, the bunching factor can appreciably change as the electron beam propagates through the wiggler. The effects of plasma frequency (or plasma density) and cyclotron frequency on the output power and saturation length have been studied. Simulation results indicate that with increasing the plasma frequency, the power increases and the saturation length decreases. In addition, when density of background plasma is higher than the electron beam density (i.e., for a dense plasma channel), the plasma effects are more pronounced and the FEL-power is significantly high. It is also found that with increasing the strength of the external magnetic field frequency, the power decreases and the saturation length increases, noticeably.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coulomb gauge approach for charmonium meson and hybrid radiative transitions

We consider the lowest order interaction of the Foldy-Wouthuysen QED and QCD Hamiltonian in the Coulomb gauge approach, to describe radiative transitions between conventional and hybrids charmonium mesons. The results are compared to potential quark models and lattices calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Charmonium meson and hybrid radiative transitions

We consider the non-relativistic limit of the QCD Hamiltonian in the Coulomb gauge, to describe radiative transitions between conventional charmonium states and from the lowest multiplet of cc¯ hybrids to charmonium mesons. The results are compared to potential quark models and lattices calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Medipix quantum area detector allows rotation electron diffraction data collection from submicrometre three-dimensional protein crystals

An ultrasensitive Medipix2 detector allowed the collection of rotation electron-diffraction data from single three-dimensional protein nanocrystals for the first time. The data could be analysed using the standard X-ray crystallography programs MOSFLM and SCALA. When protein crystals are submicrometre-sized, X-ray radiation damage precludes conventional diffraction data collection. For crystals that are of the order of 100 nm in size, at best only single-shot diffraction patterns can be collected and rotation data collection has not been possible, irrespective of the diffraction technique used. Here, it is shown that at a very low electron dose (at most 0.1 e{sup −} Å{sup −2}), a Medipix2 quantum area detector is sufficiently sensitive to allow the collection of a 30-frame rotation series of 200 keV electron-diffraction data from a single ∼100 nm thick protein crystal. A highly parallel 200 keV electron beam (λ = 0.025 Å) allowed observation of the curvature of the Ewald sphere at low resolution, indicating a combined mosaic spread/beam divergence of at most 0.4°. This result shows that volumes of crystal with low mosaicity can be pinpointed in electron diffraction. It is also shown that strategies and data-analysis software (MOSFLM and SCALA) from X-ray protein crystallography can be used in principle for analysing electron-diffraction data from three-dimensional nanocrystals of proteins.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-T-12: A Feasibility Study of Patient Specific QA Using Gafchromic Film of Dynamic Feathering in Junctions of Craniospinal Irradiation

Purpose: Cranio-spinal irradiation is the most complicated format of the conventional external beam radiation therapy because it involves matches of non-coplanar beams which are susceptible to daily setup errors. This study explores the efficacy of Gafchromic film dosimetry to quantitatively verify the junctions for cranio-spinal radiation feathered with field in field technique. Methods: 15cm in thickness of solid water phantom was scanned vertically and exported to the Pinnacle TPS as primary phantom data set. A patient cranio-spinal plan, consisted of two bilateral whole brain beams dynamically matched with a posterior spinal beam using field in field technique, was transferred to the phantom and recalculated for one fraction with set monitor units identical to the original plan. Next, planar dose distribution on the phantom was exported to the FilmQA Pro 2013 software (Ashland, Inc.) in binary format for comparison with the measured dose distribution. An EBT2 film was sandwiched in the middle of the phantom and the phantom was set up according to the QA plan based on the room laser system. The shifts instructions associated with the patient original plan were made and the beams from the patient original plan delivered to the solid water phantom via the record and verify system in QA mode. The dose distribution from the measured film was compared with the planned reference distribution using gamma analysis and profile comparison. Results: Gamma passing rate of 91 % with DTA 3mm and 5% dose difference was obtained within the junction region, significantly greater passing rate above 95 % was obtained in the homogeneous region of the brain field. Conclusion: This study confirms that Gafchromic film dosimetry can be used to validate the efficacy of FIF feathering technique for cranio-spinal treatment. FIF technique with Gafchromic dosimetry may now be the new standard for delivering efficient and accurate cranio-spinal radiation with confidence.

60 APPLIED LIFE SCIENCES↗

SU-E-T-429: Uncertainties of Cell Surviving Fractions Derived From Tumor-Volume Variation Curves

Purpose: To evaluate uncertainties of cell surviving fraction reconstructed from tumor-volume variation curves during radiation therapy using sensitivity analysis based on linear perturbation theory. Methods: The time dependent tumor-volume functions V(t) have been calculated using a twolevel cell population model which is based on the separation of entire tumor cell population in two subpopulations: oxygenated viable and lethally damaged cells. The sensitivity function is defined as S(t)=[δV(t)/V(t)]/[δx/x] where δV(t)/V(t) is the time dependent relative variation of the volume V(t) and δx/x is the relative variation of the radiobiological parameter x. The sensitivity analysis was performed using direct perturbation method where the radiobiological parameter x was changed by a certain error and the tumor-volume was recalculated to evaluate the corresponding tumor-volume variation. Tumor volume variation curves and sensitivity functions have been computed for different values of cell surviving fractions from the practically important interval S{sub 2}=0.1-0.7 using the two-level cell population model. Results: The sensitivity functions of tumor-volume to cell surviving fractions achieved a relatively large value of 2.7 for S{sub 2}=0.7 and then approached zero as S{sub 2} is approaching zero Assuming a systematic error of 3-4% we obtain that the relative error in S{sub 2} is less that 20% in the range S2=0.4-0.7. This Resultis important because the large values of S{sub 2} are associated with poor treatment outcome should be measured with relatively small uncertainties. For the very small values of S2<0.3, the relative error can be larger than 20%; however, the absolute error does not increase significantly. Conclusion: Tumor-volume curves measured during radiotherapy can be used for evaluation of cell surviving fractions usually observed in radiation therapy with conventional fractionation.

60 APPLIED LIFE SCIENCES↗

SU-E-T-483: In Vivo Dosimetry of Conventional and Rotational Intensity Modulated Radiotherapy Using Integral Quality Monitor (IQM)

Purpose: To investigate the accuracy, sensitivity and constancy of integral quality monitor (IQM), a new system for in vivo dosimetry of conventional intensity modulated radiation therapy (IMRT) or rotational volumetric modulated arc therapy (VMAT) Methods: A beta-version IQM system was commissioned on an Elekta Infinity LINAC equipped with 160-MLCs Agility head. The stationary and rotational dosimetric constancy of IQM was evaluated, using five-field IMRT and single-or double-arc VMAT plans for prostate and head-and-neck (H&N) patients. The plans were delivered three times over three days to assess the constancy of IQM response. Picket fence (PF) fields were used to evaluate the sensitivity of detecting MLC leaf errors. A single leaf offset was intentionally introduced during delivery of various PF fields with segment apertures of 3×1, 5×1, 10×1, and 24×1cm2. Both 2mm and 5mm decrease in the field width were used. Results: Repeated IQM measurements of prostate and H&N IMRT deliveries showed 0.4 and 0.5% average standard deviation (SD) for segment-by-segment comparison and 0.1 and 0.2% for cumulative comparison. The corresponding SDs for VMAT deliveries were 6.5, 9.4% and 0.7, 1.3%, respectively. Statistical analysis indicates that the dosimetric differences detected by IQM were significant (p < 0.05) in all PF test deliveries. The largest average IQM signal response of a 2 mm leaf error was found to be 2.1% and 5.1% by a 5mm leaf error for 3×1 cm2 field size. The same error in 24×1 cm2 generates a 0.7% and 1.4% difference in the signal. Conclusion: IQM provides an effective means for real-time dosimetric verification of IMRT/ VMAT treatment delivery. For VMAT delivery, the cumulative dosimetry of IQM needs to be used in clinical practice.

60 APPLIED LIFE SCIENCES↗

Developing Ultra-small Scale Mechanical Testing Methods and Microstructural Investigation Procedures for Irradiated Materials

Nuclear materials are an essential aspect of nuclear engineering. While great effort is spent on designing more advanced reactors or enhancing a reactor’s safety, materials have been the bottleneck of most new developments. The designs of new reactor concepts are driven by neutronic and thermodynamic aspects, leading to unusual coolants (liquid metal, liquid salt, gases), higher temperatures, and higher radiation doses than conventional light water reactors have. However, any (nuclear) engineering design must consider the materials used in the anticipated application in order to ever be realized. Designs which may look easy, simple and efficient considering thermodynamics or neutronic aspects can show their true difficulty in the materials area, which then prevents them from being deployed. In turn, the materials available are influencing the neutronic and thermodynamic designs and therefore must be considered from the beginning, requiring close collaborations between different aspects of nuclear engineering. If a particular design requires new materials, the licensing of the reactor must be considered, but licensing can be a costly and time consuming process that results in long lead times to realize true materials innovation.

36 MATERIALS SCIENCE↗

Characteristics of infrared photodetectors produced by radiation doping.

High-energy electrons (approximately 7 MeV) were used to radiation-dope extrinsic silicon. Both n- and p-type silicon photodetectors were fabricated using this doping technique. The 500 K blackbody responsivity, spectral response, and peak detectivity were determined for these devices. The peak detectivity values measured were 4.8 Gm Hz to the 1/2 power per W at 2.15 microns for 0.1-ohm-cm n-type devices and 3.7 Gm Hz to the 1/2 power per W at 40 microns for 10-ohm-cm p-type detectors. A comparison of the thermally generated background majority carrier concentration for radiation-doped and conventional impurity-doped detectors is made.

Gross, C.↗

Rotating bubble membrane radiator for space applications

An advanced radiator concept for heat rejection in space is described which uses a two-phase working fluid to radiate waste heat. The development of advanced materials and the large surface area per mass makes the Bubble Membrane Radiator an attractive alternative to both conventional heat pipes and liquid droplet radiators for mid to high temperature applications. A system description, a discussion of design requirements, and a mass comparison with heat pipes and liquid droplet radiators are provided.

Webb, Brent J.↗

Solution accuracies of finite element reentry heat transfer and thermal stress analyses of Space Shuttle Orbiter

Accuracies of solutions (structural temperatures and thermal stresses) obtained from different thermal and structural FEMs set up for the Space Shuttle Orbiter (SSO) are compared and discussed. For studying the effect of element size on the solution accuracies of heat-transfer and thermal-stress analyses of the SSO, five SPAR thermal models and five NASTRAN structural models were set up for wing midspan bay 3. The structural temperature distribution over the wing skin (lower and upper) surface of one bay was dome shaped and induced more severe thermal stresses in the chordwise direction than in the spanwise direction. The induced thermal stresses were extremely sensitive to slight variation in structural temperature distributions. Both internal convention and internal radiation were found to have equal effects on the SSO.

Ko, William L.↗