Search NASA⌕ Search

SEARCH · Search NASA

Results for “CORROSIVE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Assessment of the Corrosion Risks to a Double Shell Tank During the Selective Removal of a Cesium-rich Supernate Layer - 20227

The Direct Feed Low Activity Waste (DF-LAW) activity will provide the initial feed to the Waste Treatment and Immobilization Plant at the Hanford Tank Farm facility. Feed preparation for DF-LAW will be carried out in multiple double shell waste tanks (DST) utilizing the Tank Side Cesium Removal (TSCR) process. Tank AP-106 will be an integral part of the TSCR process and hence key to the DFLAW activity. Prior to being utilized for this purpose, the Cs-137 concentration levels in the AP-106 supernate must be reduced significantly. The AP-106 re-purposing process manages normal waste tank addition procedures such that waste acceptance criteria objectives for Cs-137 removal are achieved. As this process was being developed, several concerns regarding tank integrity during and after repurposing of Tank AP-106, and the associated tanks (i.e., AP-102, AN-101, and AP-108), were addressed. The potential corrosion degradation mechanisms identified based on process knowledge included: general and pitting corrosion, caustic stress corrosion cracking, concentration cell corrosion, and microbiologically induced corrosion (MIC). A systematic approach was undertaken to assess the risk of corrosion during the AP-106 re-purposing process. The assessment considered the initial and present condition of the tank, the service history of the tank, the environmental conditions created in each tank during each stage of the process, process timing, and corrosion testing and modeling that approximated tank conditions. Based on this information, recommendations were provided to minimize the exposure of the tank to corrosive conditions. These recommendations included time limits for each stage of the process, staging of corrosion inhibitor solutions should process delays occur, and waste sampling with potential chemistry adjustments at defined steps in the process. Additionally, recommendations for post-process supernate chemistry adjustments and tank inspections were put forth. The greatest risk for this process occurs during the manipulation of large quantities of Columbia River water (i.e., greater than 450,000 gallons) within AP-106, the associated tanks and the supporting infrastructure (i.e., transfer line piping). This risk becomes more pronounced if there is a process upset and the tank walls remain exposed to a corrosive condition longer than intended. As long as the river water is blended into the supernate in a timely fashion, and the waste is adjusted appropriately with corrosion inhibitors, corrosion may be minimized and the final condition of the supernate in AP-106 and the associated tanks is expected to be in compliance with corrosion chemistry requirements. Contingency plans will be made to minimize the impact of a process upset. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Electrochemical metrics for corrosion resistant alloys

Abstract Corrosion is an electrochemical phenomenon. It can occur via different modes of attack, each having its own mechanisms, and therefore there are multiple metrics for evaluating corrosion resistance. In corrosion resistant alloys (CRAs), the rate of localized corrosion can exceed that of uniform corrosion by orders of magnitude. Therefore, instead of uniform corrosion rate, more complex electrochemical parameters are required to capture the salient features of corrosion phenomena. Here, we collect a database with an emphasis on metrics related to localized corrosion. The six sections of the database include data on various metal alloys with measurements of (1) pitting potential, E pit , (2) repassivation potential, E rp , (3) crevice corrosion potential, E crev , (4) pitting temperature, T pit , (5) crevice corrosion temperature, T crev , and (6) corrosion potential, E corr , corrosion current density, i corr , passivation current density, i pass , and corrosion rate. The experimental data were collected from 85 publications and include Al- and Fe-based alloys, high entropy alloys (HEAs), and a Ni-Cr-Mo ternary system. This dataset could be used in the design of highly corrosion resistant alloys.

36 MATERIALS SCIENCE↗

Launch Pad Coatings for Smart Corrosion Control

Corrosion is the degradation of a material as a result of its interaction with the environment. The environment at the KSC launch pads has been documented by ASM International (formerly American Society for Metals) as the most corrosive in the US. The 70 tons of highly corrosive hydrochloric acid that are generated by the solid rocket boosters during a launch exacerbate the corrosiveness of the environment at the pads. Numerous failures at the pads are caused by the pitting of stainless steels, rebar corrosion, and the degradation of concrete. Corrosion control of launch pad structures relies on the use of coatings selected from the qualified products list (QPL) of the NASA Standard 5008A for Protective Coating of Carbon Steel, Stainless Steel, and Aluminum on Launch Structures, Facilities, and Ground Support Equipment. This standard was developed to establish uniform engineering practices and methods and to ensure the inclusion of essential criteria in the coating of ground support equipment (GSE) and facilities used by or for NASA. This standard is applicable to GSE and facilities that support space vehicle or payload programs or projects and to critical facilities at all NASA locations worldwide. Environmental regulation changes have dramatically reduced the production, handling, use, and availability of conventional protective coatings for application to KSC launch structures and ground support equipment. Current attrition rate of qualified KSC coatings will drastically limit the number of commercial off the shelf (COTS) products available for the Constellation Program (CxP) ground operations (GO). CxP GO identified corrosion detection and control technologies as a critical, initial capability technology need for ground processing of Ares I and Ares V to meet Constellation Architecture Requirements Document (CARD) CxP 70000 operability requirements for reduced ground processing complexity, streamlined integrated testing, and operations phase affordability. Researchers at NASA's Corrosion Technology Laboratory at KSC are developing a smart, environmentally friendly coating system for early corrosion detection, inhibition, and self healing of mechanical damage without external intervention. This smart coating will detect and respond actively to corrosion and mechanical damage such as abrasion and scratches, in a functional and predictable manner, and will be capable of adapting its properties dynamically. This coating is being developed using corrosion sensitive microcapsules that deliver the contents of their core (corrosion inhibiting compounds, corrosion indicators, and self healing agents) on demand when corrosion or mechanical damage to the coating occurs.

Calle, Luz M.↗

Interaction between corrosion crack width and steel loss in RC beams corroded under load

This paper presents results and discussions on an experimental study conducted to relate the rate of widening of corrosion cracks with the pattern of corrosion cracks as well as the level of steel corrosion for RC beams (153 x 254 x 3000 mm) that were corroded whilst subjected to varying levels of sustained loads. Steel corrosion was limited to the tensile reinforcement and to a length of 700 mm at the centre of the beams. The rate of widening of corrosion cracks as well as strains on uncracked faces of RC beams was constantly monitored during the corrosion process, along the corrosion region and along other potential cracking faces of beams using a demec gauge. The distribution of the gravimetric mass loss of steel along the corrosion region was measured at the end of the corrosion process. The results obtained showed that: the rate of widening of each corrosion crack is dependent on the overall pattern of the cracks whilst the rate of corrosion is independent of the pattern of corrosion cracks. A mass loss of steel of 1% was found to induce a corrosion crack width of about 0.04 mm.

36 MATERIALS SCIENCE↗

Discerning the effect of various irradiation modes on the corrosion of Zircaloy-4

Using proton irradiation, this study investigates the individual influence of several factors on the corrosion kinetics of Zircaloy-4 in a hydrogenated water environment simulating a Pressurized Water Reactor (PWR). Using both simultaneous irradiation-corrosion and autoclave corrosion, we separately examine: (i) the effect of pre-irradiation on modifying the structure of the material, (ii) the impact of irradiation on creating defects in the growing oxide layer during corrosion, and (iii) the influence of irradiation on increasing the corrosion potential through radiolysis during corrosion. To replicate neutron-irradiated microstructure, two proton pre-irradiation schedules were employed: Schedule 1 (isothermal irradiation at 350 °C to 5 dpa) to simulate high-temperature PWR conditions, and Schedule 2 (two-step process: irradiation to 2.5 dpa at -10 °C followed by 2.5 dpa at 350 °C) to simulate lower temperature PWR and Boiling Water Reactor (BWR) conditions. Long-term autoclave corrosion testing over 360 days at 320 °C revealed no significant difference between unirradiated samples and those pre-irradiated according to either schedule, with all samples exhibiting sub-cubic kinetics within the pre-transition regime. Irradiated samples underwent Simultaneous Irradiation Corrosion (SIC) tests, corroding in 320 °C water while being irradiated with protons. Corrosion was found to accelerate in all SIC-tested samples relative to autoclave conditions, with the greatest increase observed in non-pre-irradiated samples. Pre-irradiation with either schedule resulted in a slower corrosion rate compared to non-pre-irradiated regions under SIC conditions. The degree of radiolysis observed in the SIC tests surpassed typical PWR conditions, approaching levels found in BWRs. Radiolysis products were identified as the primary contributors to accelerated corrosion, corroborated by radiolysis bar tests. Furthermore, these findings underscore the intricate interactions between irradiation, corrosion, and water chemistry in determining Zircaloy-4 corrosion kinetics within nuclear reactor environments.

Pressurized Water Reactor↗

Progress in Understanding the Origins of Excellent Corrosion Resistance in Metallic Alloys: From Binary Polycrystalline Alloys to Metallic Glasses and High Entropy Alloys

Some of the factors responsible for good corrosion resistance of select polycrystalline and emerging alloys in chloride solutions are discussed with a goal of providing some perspectives on the current status and future directions. Traditional metallic glass alloys, single phase high entropy alloys (HEAs), early metallic glasses, and high entropy metallic glasses are all emerging corrosion-resistant alloys (CRAs) that utilize traditional strategies for improved corrosion resistance as well as take advantage of some other novel beneficial attributes. These materials enjoy many degrees of freedom as far as choice of both composition and structure, providing great flexibility in the pursuit of superior corrosion resistance. The new materials depart from classical solvent-solute type polycrystalline binary or ternary alloys. Thus, such emerging materials provide significant opportunities to achieve even greater improvements in corrosion resistance in harsh environments. Several examples of the unique corrosion properties of selected materials in the context of modern theories of corrosion are discussed herein. Discussion is restricted to solid-solution binary or ternary polycrystalline alloys, several metallic glass alloys, and single phase HEAs. A common feature of many CRAs is that composition and microstructure often affect both passivity and resistance to localized corrosion that can be divided into initiation, stabilization, and propagation stages. Enormous complexities in protective oxide structures and chemistries and the large number of combinatorial possibilities in newer materials such as HEAs preclude trial-and-error approaches and perhaps even combinatorial experimental design. Computational materials methodologies will be required in the search for new corrosion-resistant alloys in these material classes. The search must consider the best scientific insights available regarding how major and minor alloy additions, as well as various microstructural attributes, contribute to corrosion mitigation. Additional scientific insights, as they emerge, will enable choices beyond the reliance on high concentrations of alloying elements that are known to affect passivity breakdown and pit stabilization. A challenge is to connect the “basic attributes” of an alloy with its properties. The strength of this connection will likely require new scientific principles enabling deep multiphysics insights in order to link feature(s) such as composition and metallurgical phases to the desired corrosion properties. Application of data informatics will likely also play a role given the plethora of variables that are important in corrosion and the difficulty in assessing all relationships. Here, the opportunity exists to accelerate the design of emerging materials for high corrosion resistance.

36 MATERIALS SCIENCE↗

Corrosion Monitoring in an Irradiated/Used Fuel Dry Storage Container - 19193

A corrosion monitoring system was developed to monitor the corrosion behaviour of steel components embedded in the high density concrete of a Dry Storage Container (DSC). The DSC is a free-standing reinforced concrete container, with an inner carbon-steel liner and an outer carbon-steel shell, for the storage, on-site transfer and off-site transportation of irradiated Candu fuel. Normally, uncontaminated concrete is benign with regards to embedded steel components because high alkalinity in the concrete leads to formation of a passive film on the steel surface, which prevents excessive metal loss. However, corrosion of steel in concrete may be promoted by one or more of local concentration of chloride ions or local loss of alkalinity. For the DSC, it is recognized that the above mechanism(s) are unlikely, however, if any did exist, the corrosion mechanisms that could then occur would include corrosion of carbon steel components and stress corrosion cracking of 304L stainless steel components. In order to confirm that these unlikely events are not occurring, Ontario Power Generation has undertaken a project to investigate the corrosion behaviour of metallic components embedded in the DSC's high density concrete. A corrosion monitoring system that can be installed within the concrete space of a DSC was designed and installed to monitor changes in temperature, corrosion potential, corrosion rate, and electrochemical noise. The corrosion monitoring system was commissioned in July 2012, followed by the commencement of monitoring and measurements. The corrosion data, collected for the three years from year 2012 to 2015, were analyzed. It was concluded that the corrosion rates of both carbon steel and stainless steel within the DSC are very low and consistent with the intended minimum operational life of the DSC. The monitoring system as a whole has allowed a systematic and long term judgement regarding the conditions within the DSCs. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Stainless steel corrosion by molten nitrates : analysis and lessons learned.

A secondary containment vessel, made of stainless 316, failed due to severe nitrate salt corrosion. Corrosion was in the form of pitting was observed during high temperature, chemical stability experiments. Optical microscopy, scanning electron microscopy and energy dispersive spectroscopy were all used to diagnose the cause of the failure. Failure was caused by potassium oxide that crept into the gap between the primary vessel (alumina) and the stainless steel vessel. Molten nitrate solar salt (89% KNO{sub 3}, 11% NaNO{sub 3} by weight) was used during chemical stability experiments, with an oxygen cover gas, at a salt temperature of 350-700 C. Nitrate salt was primarily contained in an alumina vessel; however salt crept into the gap between the alumina and 316 stainless steel. Corrosion occurred over a period of approximately 2000 hours, with the end result of full wall penetration through the stainless steel vessel; see Figures 1 and 2 for images of the corrosion damage to the vessel. Wall thickness was 0.0625 inches, which, based on previous data, should have been adequate to avoid corrosion-induced failure while in direct contact with salt temperature at 677 C (0.081-inch/year). Salt temperatures exceeding 650 C lasted for approximately 14 days. However, previous corrosion data was performed with air as the cover gas. High temperature combined with an oxygen cover gas obviously drove corrosion rates to a much higher value. Corrosion resulted in the form of uniform pitting. Based on SEM and EDS data, pits contained primarily potassium oxide and potassium chromate, reinforcing the link between oxides and severe corrosion. In addition to the pitting corrosion, a large blister formed on the side wall, which was mainly composed of potassium, chromium and oxygen. All data indicated that corrosion initiated internally and moved outward. There was no evidence of intergranular corrosion nor were there any indication of fast pathways along grain boundaries. Much of the pitting occurred near welds; however this was the hottest region in the chamber. Pitting was observed up to two inches above the weld, indicating independence from weld effects.

36 MATERIALS SCIENCE↗

Corrosion in Supercritical Carbon Dioxide: Materials, Environmental Purity, Surface Treatments, and Flow Issues (Project No. 10-872)

The supercritical CO 2 Brayton cycle is gaining importance for power conversion in the Generation IV fast reactor system because of its high conversion efficiencies. When used in conjunction with a sodium fast reactor, the supercritical CO 2 cycle offers additional safety advantages by eliminating potential sodium-water interactions that may occur in a steam cycle. In power conversion systems for Generation IV fast reactors, supercritical CO 2 temperatures could be in the range of 30°C to 650°C, depending on the specific component in the system. Materials corrosion primarily at high temperatures will be an important issue. Therefore, the corrosion performance limits for materials at various temperatures must be established. The proposed research will have four objectives centered on addressing corrosion issues in a high-temperature supercritical CO 2 environment: Task 1: Evaluation of corrosion performance of candidate alloys in high-purity supercritical CO 2 : The following alloys will be tested: Ferritic-martensitic Steels NF616 and HCM12A, austenitic alloys Incoloy 800H and 347 stainless steel, and two advanced concept alloys, AFA (alumina forming austenitic) steel and MA754. Supercritical CO 2 testing will be performed at 450°C, 550°C, and 650°C at a pressure of 20 MPa, in a test facility that is already in place at the proposing university. High purity CO 2 (99.9998%) will be used for these tests. Task 2: Investigation of the effects of CO, H 2 O, and O 2 impurities in supercritical CO 2 on corrosion: Impurities that will inevitably present in the CO 2 will play a critical role in dictating the extent of corrosion and corrosion mechanisms. These effects must be understood to identify the level of CO 2 chemistry control needed to maintain sufficient levels of purity to manage corrosion. The individual effects of important impurities CO, H 2 O, and O 2 will be investigated by adding them separately to high purity CO 2 . Task 3: Evaluation of surface treatments on the corrosion performance of alloys in supercritical CO 2 : Surface treatments can be very beneficial in improving corrosion resistance. Shot peening and yttrium and aluminum surface treatments will be investigated. Shot peening refines the surface grain sizes and promotes protective Cr-oxide layer formation. Both yttrium and aluminum form highly stable oxide layers (Y 2 O 3 and Al 2 O 3 ), which can get incorporated in the growing Fe-oxide layer to form an impervious complex oxide to enhance corrosion resistance. Task 4: Study of flow-assisted corrosion of select alloys in supercritical CO 2 under a selected set of test conditions: To study the effects of flow-assisted corrosion, tests will be conducted in a supercritical CO 2 flow loop. An existing facility used for supercritical water flow studies at the proposing university will be modified for use in this task. The system is capable of flow velocities up to 10 m/s and can operate at temperatures and pressures of up to 650°C and 20 MPa, respectively. All above tasks will be performed in conjunction with detailed materials characterization and analysis using scanning electron microscopy/energy dispersive spectroscopy (SEM-EDS), x-ray diffraction (XRD), Auger electron spectroscopy (AES) techniques, and weight change measurements. Inlet and outlet gas compositions will be monitored using gas chromatography-mass spectrometry (GCMS).

36 MATERIALS SCIENCE↗

Development of Preliminary VERA-CS Crud Induced Localized Corrosion Modeling Capability

The objective of this milestone was to develop a crud-induced localized corrosion (CILC) screening capability in VERA-CS using existing codes and capabilities that had been developed in the Consortium for Advanced Simulation of Light Water Reactors (CASL) as part of the efforts to resolve the crud challenge problem. The milestone work focused on improving existing CASL software and implementing clad corrosion modeling into VERA-CS. Clad corrosion modeling was implemented by creating an application interface (API) in the Cicada software so that its clad heat transfer and corrosion models could be used in VERA-CS. Cicada was coupled to the subchannel code CTF for solving crud and corrosion growth. Additionally, a clad corrosion model was added directly to CTF to serve as an alternate approach. The rod thermal hydraulic reconstruction (ROTHCON) process, which is used for capturing computational fluid dynamics (CFD)-predicted rod-surface heat and turbulence behavior that can impact crud-induced power shift (CIPS) and CILC prediction, was also implemented into VERA-CS. Usability improvements were made to this feature, which was developed over several previous milestones, so that the VERA-CS user can link spacer grids in a VERA-CS model to an applicable pregenerated spacer grid data file if available. Several assessments were performed to demonstrate the proper functioning of the new capability. Sensitivity studies were performed to demonstrate the effect of crud lithium content, oxide thermal conductivity, Cicada mesh refinement, and ROTHCON coupling mesh refinement on predicted amounts of crud and oxide growth. A full-scale demonstration was performed by running Seabrook Cycle 5 with the CILC capability. Some general observations were made from the assessments. It was observed that predicted corrosion thickness is less than anticipated for CILC cases, so further work is needed to better understand and improve the corrosion modeling. Refining the coupling mesh in the ROTHCON process leads to increased corrosion and crud thickness, which can affect where crud and corrosion grow, how thick it gets, and how many rods experience crud and corrosion growth. Results indicate that applying the ROTHCON process and refining the coupling mesh leads to only a slight increase in total core maximum crud and corrosion thickness, but it leads to a significant increase in the number of rods with a maximum thickness that surpasses a set threshold value (i.e., more rods grow thicker corrosion and crud). Computational performance of the simulation is degraded by a factor of 5{6 with high coupling mesh refinement. The impact of the ROTHCON coupling mesh refinement on total core crud mass is less significant; however, using the ROTHCON process with CFD-generated data over the Yao{Hochreiter{Leech (YHL) model in CTF leads to significantly different amounts of total core crud mass. Future work on the CILC screening capability will include model improvement and validation, development and testing of a CILC-risk screening criteria, and performance improvements.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fe Coated Optical Fiber for Distributed Corrosion Monitoring in Soil and Aqueous Environment

Natural gas pipeline corrosion represents a substantial cost and safety concern during normal operations. Effective monitoring of corrosion is important to detect and mitigate pipeline risks before corrosion-related catastrophic events happen. Here, we describe the use of Fe-coated optical fiber sensors (OFS) for distributed corrosion monitoring where Fe acts as a corrosion proxy. By using an optical backscatterring reflectometer (OBR), corrosion was monitored based on the increase in backscattered intensity amplitude of the light being passed as Fe undergoes corrosion. The Fe-coated OFSs were prepared with a film thickness between 25-225 nm by an electroless plating approach and corroded by a CO2-saturated acidic electrolyte. The corrosion rate was approximately 2.5 mm/yr for Fe with a film thickness of 30 nm and increased with film thickness. Backscattering-based corrosion rates were supported by visible light transmission measurements, which have been previously demonstrated. Additionally, a correlation between the intermittent transmission and residual Fe film thickness during corrosion of Fe was established. Corrosion was measurable out to > 100 m which is a significant improvement over our previous work showing corrosion sensing at < 10 m. The corrosion sensor was also tested in soil at >1 ft depth. Fe-coated OFS was loaded into a Draka cable which provides mechanical support during fiber deployment and installation into either acidified soil, top-soil, or sandy soil.

aqueous environment↗

In Situ High-Temperature TEM Observation of Inconel Corrosion by Molten Chloride Salts with N 2 , O 2 , or H 2 O

Here, in situ transmission electron microscopy (TEM) diffraction and imaging techniques are used to monitor and quantify corrosion of Inconel-625 by pure molten chloride salts (MgCl 2 – NaCl – KCl) at 500 °C–800 °C in 1.0 atm inert N 2 or pure O2, or by salts which are controllably hydrated in a high vacuum chamber. The isothermal corrosion rate R in inert N 2 increases from 203 ± 30 μ m year –1 at 700 °C to 463 ± 30 μ m year –1 at 800 °C. An oxygen ambient causes a six-fold increase to R = 1261 ± 170 μ m year –1 at 700 °C. Salt hydration dramatically accelerates corrosion to R > 3 × 10 5 μ m year –1 at 700 °C while it leads to a more moderate R = 95 ± 20 and 486 ± 30 μ m year –1 at 500 °C and 600 °C, respectively. These isothermal corrosion rates indicate that the molten chloride corrosion is significantly accelerated by salt hydration at temperatures above 600 °C, where corrosion is aggravated by increased generation and solubility of corrosive HCl gases. Hence, to reduce rate of corrosion it is important to both avoid incorporation of H 2 O into the system at each stage and ensure proper flushing of the system before increasing the temperature beyond 600 °C. Compositional analysis of the corroded cells indicate that corrosion in O 2 ambient is dominated by oxidation of metals by O 2 gas dissolved in the chloride melt, but corrosion in H 2 O ambients is caused by chlorination of metals by dissolved HCl gas and MgOH + ions. So, to reduce rate of corrosion, steps should be taken to tailor chloride melt compositions that has low solubility for HCl and O 2 . All of our corroded samples exhibit passive-protective oxide layers of Cr, Mg, and Ni. In addition, distinct volatile compounds of Ni, Mo and Cr involving NiCl 2 , (Na,K) 2 MoO 4 and CrO 2 (OH) 2 are detected in N 2 , H 2 O, and O 2 ambients, respectively. We believe that corrosion acceleration can be minimized by minimizing formation of volatile by-products or promoting reactions that could convert these volatile compounds to solid phases, as these volatile compounds led to destruction of protective oxide layers.

14 SOLAR ENERGY↗

The Development of the Corrosion Control Limits for Direct Feed Low-Activity Waste Melter-Off Gas Returns to Hanford Tank Farms - 18196

The Savannah River National Laboratory has been developing a corrosion model to facilitate implementation of Hanford's Direct Feed Low Waste (DFLAW) flowsheet. Laboratory testing and statistical analysis have been used to determine the necessary corrosion controls for returning effluent from the Hanford Waste Treatment and Immobilization Plant's Low Activity Waste Vitrification melter off-gas treatment system to the tank farms. The stream compositions are projected to contain components at relative concentrations that are significantly more corrosive toward carbon steel, specifically halide and sulfate anions, than the current waste compositions in the tank farms. Administrative programs are in place to mitigate potential corrosion mechanisms and thereby maintain the structural and leak integrity functions of these waste tanks throughout their intended service life. Waste chemistry and temperature control are the means by which corrosion degradation of the waste tanks is minimized. The current administrative specification for chemical composition and temperature for the underground carbon steel waste tanks is not designed to control the higher halide or sulfate composition. The content of the DFLAW waste streams will be diverse and depend on several factors, such as the melter feed composition and melter idle time. Other factors, such as effluent management of the off gas water collections, will impact the variability of the return streams even more. The work performed by the Savannah River National Laboratory has confirmed that the halide ions are the most aggressive species in the return stream compositions projected using a flowsheet simulation, and nitrite is the most effective inhibitor at pH 10 and 40 deg. C. This test program has employed statistically designed test matrices to determine the dependent variables and the interaction terms between the variables that are significant for the corrosion model and definition of the corrosion control specifications. The first phase of testing focused on identifying aggressive species in off-gas condensate return compositions that present a propensity for localized corrosion attack, namely pitting corrosion. The second phase of testing focused on developing a corrosion model from the interaction terms that will predict the susceptibility of pitting in the double shell tank system based on waste composition and the required amount of corrosion inhibitor. The data collected from this testing program in conjunction with other testing programs, both at the Savannah River Site and the Hanford Site, along with operations knowledge, has determined the chemistry ranges and chemical species requirements for corrosion control in the Hanford double-shell tank system for the effluents generated in the Hanford Waste Treatment and Immobilization Plant's Low Activity Waste facility during the DFLAW phase of operations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modelling uranium dioxide corrosion under repository conditions: A pore-scale study of the chemical and thermal processes

This paper investigates the corrosion behaviors of spent uranium dioxide (UO 2 ) fuel when placed in geological repositories. We performed pore-scale reactive transport simulations of the UO 2 corrosion process in a defective fuel rod with different orientations of breach or fracture on its clad. It is found that the corrosion rate has strong dependency on the breach orientation. The highest corrosion rate of UO 2 is calculated when the angle between the groundwater flow direction and the clad fracture reaches 180°. UO 2 corrosion simulations with different flow rates are compared. The results show the higher flow rate accelerates the corrosion of UO 2 fuel. The effect of pH on the corrosion process is also determined. It is indicated that higher pH can limit the corrosion of UO 2 by reducing the reaction rate. The dependence of reaction rate and time on reactive surface area is explored. Spent fuel with lower surface area demonstrates longer lifetime under corrosion conditions. A numerical model coupling thermal conduction and chemical reactions is developed to assess the impact of temperature on the process of UO 2 corrosion. The results show that higher temperature leads to larger corrosion rates for UO 2 . Here, the predicted reaction rates are higher in comparison with the isothermal results. Hence, our results can help improve the fundamental understanding of UO 2 corrosion in geological repositories for long-term storage of spent nuclear fuels and provide guidance for the safe operations and selection of appropriate repositories.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Corrosion Assessment of Candidate Materials for the SHINE Subcritical Assembly Vessel and Components—FY14 Report

Laboratory corrosion testing of candidate alloys—including Zr-4 and Zr-2.5Nb representing the target solution vessel, and 316L, 2304, 304L, and 17-4 PH stainless steels representing process piping and balance-of-plant components—was performed in support of the proposed SHINE process to produce 99 Mo from low-enriched uranium. The test solutions used depleted uranyl sulfate in various concentrations and incorporated a range of temperatures, excess sulfuric acid concentrations, nitric acid additions (to simulate radiolysis product generation), and iodine additions. Testing involved static immersion of coupons in solution and in the vapor above the solution, and was extended to include planned-interval tests to examine details associated with stainless steel corrosion in environments containing iodine species. A large number of galvanic tests featuring couples between a stainless steel and a zirconium-based alloy were performed, and limited vibratory horn testing was incorporated to explore potential erosion/corrosion features of compatibility. In all cases, corrosion of the zirconium alloys was observed to be minimal, with corrosion rates based on weight loss calculated to be less than 0.1 mil/year with no change in surface roughness. The resulting passive film appeared to be ZrO 2 with variations in thickness that influence apparent coloration (toward light brown for thicker films). Galvanic coupling with various stainless steels in selected exposures had no discernable effect on appearance, surface roughness, or corrosion rate. Erosion/corrosion behavior was the same for zirconium alloys in uranyl sulfate solutions and in sodium sulfate solutions adjusted to a similar pH, suggesting there was no negative effect of uranium resulting from fluid dynamic conditions aggressive to the passive film. Corrosion of the candidate stainless steels was similarly modest across the entire range of exposures. However, some sensitivity to corrosion of the stainless steels was observed in solutions with 50 wppm iodine (the actual SHINE process expects 0.1–1 wppm) with the highest corrosion rates (up to ~6 mil/year) observed on specimens exposed in the vapor phase. Lower concentrations of iodine species (5 or 28 wppm) proved much less corrosive, and the planned-interval data indicated that metal corrodibility decreased with time for all immersed exposures and, with one minor exception, all vapor exposures. Little change in susceptibility to corrosion was observed as a result of nitric acid additions to the test environment (simulating radiolysis products). The trend toward reduced corrosion (immersion and vapor phase) with decreasing iodine concentration suggests that, at the expected conditions in the SHINE process, it is unlikely that iodine species will generate a general corrosion concern for the candidate stainless steels.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Fe-Coated Optical Fiber for Distributed Corrosion Monitoring in Soil and Aqueous Environments

Natural gas pipeline corrosion represents a substantial cost and safety concern during normal operations. The effective and real-time monitoring of corrosion is important to detect and mitigate pipeline risks before corrosion-related catastrophic events happen. Here, we describe the use of iron (Fe) coated optical fiber sensors (OFS) for distributed corrosion monitoring where Fe acts as a corrosion proxy. By using an optical backscattering reflectometer (OBR), corrosion was monitored based on the increase in the backscattered intensity amplitude of the light being passed as Fe underwent corrosion. The Fe-coated OFSs were prepared with a film thickness between 25–225 nanometers (nm) by an electroless plating approach and corroded by a carbon dioxide (CO2)-saturated acidic electrolyte. The corrosion rate (CR) was approximately 2.5 millimeters (mm)/year for Fe with a film thickness of 30 nm and increased with film thickness. Backscattering-based CRs were supported by visible light transmission measurements, which have been previously demonstrated. Additionally, a correlation between the intermittent transmission and residual Fe film thickness during the corrosion of Fe was established. The corrosion was measurable out to > 100 meters (m), which is a significant improvement over our previous work, which showed corrosion sensing at < 10 m. The corrosion sensor was also tested in soil at > 1 foot depth.

corrosion↗

Corrosion Testing of Refractory inContact with Molten Glasses Designed for Waste Vitrification - VSL Touchpoint Matrix Glasses

It is known that the predictive life of the refractory ceramic liner of nuclear waste glass melters is conservative, as demonstrated by performance of these materials such as in the Defense Waste Processing Facility (DWPF). The motivation for this task is to maximize the useful life of the melters that will be operated at the Waste Treatment and Immobilization Plant (WTP), which will in turn minimize procurement and disposal costs and melter outage times, as well as to identify maximum loadings in the waste glass of those species that corrode melter components. This task was initiated jointly with Pacific Northwest National Laboratory (PNNL) with the objective to develop a methodology and model to enable more accurate prediction of refractory service life under prototypic conditions from laboratory-scale material corrosion tests. Refractory corrosion is generally reported as physical material loss, measured in units of distance (e.g., inch) or as physical material loss rate, measured in units of distance per time (e.g., inch/day). In post-operational melters, the refractory corrosion is measured directly, sometimes reported as corrosion depth. Crucible tests are used in the laboratory to accelerate the refractory corrosion to facilitate a meaningful measurement in a commensurate amount of time. Crucible tests are particularly useful in understanding refractory corrosion across a large glass composition space, where operational testing would be prohibitive. Some of the critical parameters that are known to influence refractory corrosion by molten glass in a crucible test are temperature, system redox, molten salt phases, glass chemistry, and test duration. The majority of data collected for Monofrax® K-3 (hereafter referred to as K-3) corrosion is from crucible tests, but a small amount comes directly from scaled and production melters. Crucible test data has been collected under varying conditions, whereas data collected from operational melters is relatively fewer and represents conditions specific to the melter campaign. The result is that the published data can be grouped and analyzed in multiple ways, not all of which are readily comparable. The Standard Test Method for Isothermal Corrosion Resistance of Refractories to Molten Glass (ASTM C621) outlines the general guidelines used across industry. That method describes a sealed, static test in which the surface area of the refractory coupon and the volume of glass are fixed. A significant portion of the crucible data pertaining to nuclear waste glasses has been collected in a modified configuration; the most notable differences being the surface area of the refractory coupon to volume of the glass and use of a method for bubbling the melt. To our knowledge, the influence of those parameters on the refractory corrosion has not been quantified. In this work, it was determined that static tests and bubbled tests would be performed. Savannah River National Laboratory (SRNL) was tasked with setting up and performing static testing while PNNL was tasked with setting up and performing bubbled testing. Initial activities were performed to establish laboratory methods that reproduce data comparable to existing data sets of K-3 refractory corrosion by low activity waste (LAW) and high-level waste (HLW) glass compositions. Later activities were focused on refining the test parameters to establish a standard test practice to be used between Laboratories and collecting additional data to be used in the enhanced waste glass model development. This document serves primarily to convey the refractory loss measurement results from corrosion testing of K-3 refractory with waste glass compositions developed for use in the WTP melters. The data will be used in the enhanced property/composition models being developed for waste glass vitrification and melter operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Zinc Corrosion in Borated, Buffered Post-LOCA Solutions

This current research provides a broad assessment of recently evaluated zinc corrosion in simulated non-buffered and buffered post-LOCA solution as a function of pH, temperature, velocity, boron concentration and surface area. Corrosion rates obtained can be used for further zinc borate formation analysis or to plan further zinc corrosion studies. Experiments are conducted utilizing a three-electrode electrochemical system in a glass cell. Aqueous solutions used in testing simulate reactor containment building (RCB) pool water under various LOCA scenarios that are representative of US PWR RCB pool water: boric acid only, boric acid with trisodium phosphate, boric acid with sodium hydroxide, and boric acid with sodium tetraborate. The specimens used in this work are machined from 99.6% pure zinc rods that are used as a surrogate for the high purity zinc layer of galvanized steel. Prior to the experiment, the specimens are first polished and then left exposed to the atmosphere for approximately one day at room temperature. Prior to each test, the zinc specimen are sequentially rinsed with deionized water and acetone, and then dried by evaporation in air at room temperature. Prepared samples are then mounted in the glass cell test apparatus and rotated on a spindle at a desired velocity for a specified duration. Instantaneous corrosion rate as a function of time and total zinc mass corroded, which may either be released into solution or incorporated into surface scale, is determined by electrochemical impedance spectroscopy (EIS) analysis. Corrosion rates after 24 hours of immersion are determined from a full potential dynamic scan and from weight loss measurements of descaled post-test samples. The solution zinc concentration resulting from zinc corrosion is determined by inductively coupled plasma optical emission spectroscopy (ICP-OES). Preliminary results show that zinc corrosion with a zinc surface area-to-liquid volume ratio of 0.0003 m2/L in a borated, buffered solution (55 deg. C, pH 7.2) exposed to a velocity of 0.5 ft/s is between 4.9 X to 2.3 X less than that obtained by the Kyrk et al study, which examines a lower temperature, lower pH with a 5.5 X larger surface area-to-volume ratio. This initial finding suggests that the corrosion of zinc, which supplies a zinc source term to form zinc borates, may not be insignificant under conditions of interest (borated, buffered post-LOCA solutions). Further experiments are currently underway that evaluate the influence of pH, velocity, temperature, buffer type, boron concentration and surface area-to-volume ratio on zinc corrosion. Preliminary results suggest two of the three buffer types examined as conditions of interest to US PWRs likely produce zinc corrosion within the range observed by Kyrk et al. Current preliminary results indicate that buffer type, temperature, pH and velocity each have an impact on the zinc corrosion rate. Quantification of zinc mass lost to solution and incorporated into scale is currently underway, as is the characterization of velocity and boric acid effects on zinc corrosion.

36 MATERIALS SCIENCE↗