Search NASA⌕ Search

SEARCH · Search NASA

Results for “CT images”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Path-Integrated X-Ray Images for Multi-Surface Digital Image Correlation (PI-DIC)

X-ray imaging offers unique possibilities for Digital Image Correlation (DIC), opening the door for full-field deformation measurements of a test article in complex environments where optical DIC suffers severe biases or is impossible. While X-ray DIC has been performed in the past with standard DIC codes designed for optical images, the path-integrated nature of X-ray images places constraints on the experimental setup, predominantly that only a single surface of interest moves/deforms. These requirements are difficult to realize for many practical situations and limit the amount of information that can be garnered in a single test. Other X-ray based diagnostics such as Digital Volume Correlation (DVC) and Projection DVC (P-DVC) overcome these obstacles, but DVC is limited to quasi-static tests, and both DVC and P-DVC necessitate high-resolution computed tomography (CT) scan(s) and often require a potentially invasive pattern throughout the volume of the specimen. Here this work presents a novel approach to measure time-resolved displacements and strains on multiple surfaces from a single series of 2D, path-integrated (PI) X-ray images, called PI-DIC. The principle of optical flow or conservation of intensity—the foundation of DIC—was reframed for path-integrated images, for an exemplar setup comprised of two plates moving and deforming independently. Synthetic images were generated for rigid translations, rigid rotations, and uniform stretches, where each plate underwent a unique motion/deformation. Experimental specimens were fabricated (either an aluminum plate with tantalum features or a plastic plate with steel features) and the two specimens were independently translated. PI-DIC was successfully demonstrated with the synthetic images and validated with the experimental images. Prescribed displacements were recovered for each plate from the single set of path-integrated, deformed images. Errors were approximately 0.02 px for the synthetic images with 1.5% image noise, and 0.05 px for the experimental images. These results provide the foundation for PI-DIC to measure motion and deformation of multiple, independent surfaces with subpixel accuracy from a single series of path-integrated X-ray images.

47 OTHER INSTRUMENTATION↗

DOLCE: A Model-Based Probabilistic Diffusion Framework for Limited-Angle CT Reconstruction

Limited-Angle Computed Tomography (LACT) is a non-destructive evaluation technique used in a variety of applications ranging from security to medicine. The limited angle coverage in LACT is often a dominant source of severe artifacts in the reconstructed images, making it a challenging inverse problem. We present DOLCE, a new deep model-based framework for LACT that uses a conditional diffusion model as an image prior. Diffusion models are a recent class of deep generative models that are relatively easy to train due to their implementation as image denoisers. DOLCE can form high-quality images from severely under-sampled data by integrating data-consistency updates with the sampling updates of a diffusion model, which is conditioned on the transformed limited-angle data. We show through extensive experimentation on several challenging real LACT datasets that, the same pre-trained DOLCE model achieves the SOTA performance on drastically different types of images. Additionally, we show that, unlike standard LACT reconstruction methods, DOLCE naturally enables the quantification of the reconstruction uncertainty by generating multiple samples consistent with the measured data.

Kim, Hyojin↗

Reconstruction of concrete microstructure using complementarity of X-ray and neutron tomography

The concrete microstructure was successfully reconstructed using the complementarity of X-ray and neutron computed tomography (CT). Neither tomogram alone was found to be suitable to properly describe the microstructure of concrete under this study. However, by merging the information revealed by the two modalities, and using image segmentation, noise reduction, and image registration techniques we reconstruct the concrete microstructure. Void, aggregate, and cement paste phases are successfully captured down to the images' spatial resolution, even though the aggregate consists of multiple minerals. The coarse-aggregate volume fraction of the reconstructed microstructure was similar to that of the mixing proportions. Furthermore, image-based finite element analysis is performed to demonstrate the effects of microstructure on stress concentration and strain localization.

36 MATERIALS SCIENCE↗

Examining phase separation and crystallization in glasses with X-ray nano-computed tomography

X-ray nano-computed tomography (nano-CT) is a powerful technique to characterize and visualize 3 dimensional (3D) phenomena in complex glasses at the nanoscale. This technique can offer a unique opportunity to explore the intricate morphology of multicomponent glass and glass-ceramic samples, due to its low X-ray energy and high spatial resolution (down to 50 nm). In the current demonstration paper, nano-CT provided insight into crystallization and phase separation, as well as a variety of other phenomena, including corrosion, fracture, and porosity. At scales ranging from 100 to 20 μm, the microstructures of phase separation in borosilicate, complex silicate, and chalcogenide glass compositions were examined. In addition, crystallites present in simulant nuclear waste glasses, volcanic glasses, and other related samples were explored. Nano-CT analysis can add to the understanding of (1) the formation processes, (2) distributions, interactions, and compositions of phases, and (3) the mechanisms, structures, and growth of crystallization and phase separation. Nano-CT offers wide potential in the field of glass science, especially when (1) common characterization methods are insufficient, (2) simple sample preparation is required, (3) 3D rendering is needed, or (4) compelling images of small, complex features are desired.

36 MATERIALS SCIENCE↗

Constrained GAN-Generated X-Ray CT Data For Self-Supervised And Foundation-Model Segmentation Of Concrete Microstructures

Three-dimensional characterization of materials using X-ray computed tomography (XCT) is challenging due to the complexity of internal structures, noise, and variations in resolution. Traditional computer vision models often struggle to accurately segment these images, particularly in domain-specific applications like materials science. While supervised deep learning approaches have been developed to address the limitations of conventional algorithms, they typically require large amounts of labeled training data and often fail to generalize across different datasets. Self-supervised, few-and zero-shot learning methods have gained prominence in natural image processing and segmentation tasks, but their application to scientific imaging remains limited due to the unique structural complexity, noise, and textural artifacts present in materials science data. In this work, we investigate how domain adaptation, leveraging physics-based and GAN-generated synthetic data, impacts segmentation performance. We introduce a modified Contrastive Unpaired Translation (CUT) model designed to generate realistic labeled data, which can be used for training, pre-training, and fine-tuning segmentation models for real XCT microstructure data. We evaluate the performance of two segmentation approaches: a self-supervised network (SSL-ALPNet) and a foundation model (Segment Anything Model), assessing their improvements when pre-trained and/or fine-tuned on the synthesized data. Our results demonstrate that leveraging synthetic data significantly enhances segmentation performance, particularly in challenging materials science applications.

Ziabari, Amir [ORNL] (ORCID:000000034776457X)↗

A combination interferometric and morphological image processing approach to rapid quality assessment of additively manufactured cellular truss core components

Advanced manufacturing (AM) processes such as laser powder bed fusion (LPBF) are increasingly capable of fabricating components with useful and unprecedented mechanical properties by incorporating complex internal bracing structures. From the standpoint of quality control and assessment, however, internally complex assemblies present significant build-verification challenges. Here we propose a hybrid approach to the inspection involving the application of computer-aided speckle interferometry (CASI) and morphological image processing as a rapid, inexpensive, and facile method for AM quality control. The described methodology has low capital equipment costs, is full-field and non-contact, can be used in an industrial setting, and has very low requirements in terms of operator training and expertise. Consisting primarily of the combination of image processing software with a simple optical system of variable sensitivity, the method is shown to be effective for inspection of a titanium honeycomb component subjected to differential pressure. Results are compared to those achieved with computed tomography (CT), immersion ultrasound testing (UT), and optical holographic interferometry. Here we propose several possible processing strategies for automated quality assessment based on this powerful hybrid approach.

36 MATERIALS SCIENCE↗

State-of-Charge Investigation of Lithium Manganese Dioxide Primary Batteries Utilizing X-ray Computed Tomography

Lithium primary batteries (LPBs) represent a class of energy storage devices, uniquely suited for mission-critical applications including emergency backup power, aerospace and defense electronics, implantable medical devices, and remote sensing. Despite their technological maturity and distinct advantages over rechargeable lithium-ion batteries (i.e., superior shelf life and operational simplicity), state-of-charge (SoC) estimation in these batteries remains a persistent challenge due to the lack of a reliable, quantifiable diagnostic technique. In this work, we investigate X-ray computed tomography (X-CT) as a transformative and accurate SoC estimation technique for LPBs. Results gained through X-CT measurements reveal systematic, quantifiable structural changes in cathode morphology and geometry during discharge, establishing a direct structural basis for SoC estimation, with a maximum relative standard deviation of 2.3%. This work establishes a pathway toward operando, imaging-driven SoC diagnostics that can significantly enhance the reliability of SoC estimation in LPBs.

25 ENERGY STORAGE↗

Deep-ultraviolet ptychographic pocket-scope (DART): mesoscale lensless molecular imaging with label-free spectroscopic contrast

The mesoscale characterization of biological specimens has traditionally required compromises between resolution, field-of-view, depth-of-field, and molecular specificity, with most approaches relying on external labels. Here we present the Deep-ultrAviolet ptychogRaphic pockeT-scope (DART), a handheld platform that transforms label-free molecular imaging through intrinsic deep-ultraviolet spectroscopic contrast. By leveraging biomolecules’ natural absorption fingerprints and combining them with lensless ptychographic microscopy, DART resolves down to 308-nm linewidths across centimeter-scale areas while maintaining millimeter-scale depth-of-field. The system’s virtual error-bin methodology effectively eliminates artifacts from limited temporal coherence and other optical imperfections, enabling high-fidelity molecular imaging without lenses. Through differential spectroscopic imaging at deep-ultraviolet wavelengths, DART quantitatively maps nucleic acid and protein distributions with femtogram sensitivity, providing an intrinsic basis for explainable virtual staining. We demonstrate DART’s capabilities through imaging of tissue sections, cytopathology specimens, blood cells, and neural populations, revealing detailed molecular contrast without external labels. The combination of high-resolution molecular mapping and broad mesoscale imaging in a portable platform opens new possibilities from rapid clinical diagnostics, tissue analysis, to biological characterization in space exploration.

60 APPLIED LIFE SCIENCES↗

A Co-Registered In-Situ and Ex-Situ Dataset of Electrical, Acoustic, and CT Characteristics from Wire Arc Additive Manufacturing Process

Recent progress in sensing techniques and data analytics tools have significantly accelerated the development of Wire Arc Additive Manufacturing (WAAM) systems. This data centric approach emphasizes leveraging available data throughout the production process to optimize performance. Integration of extensive data analysis provides the opportunity to improve precision, reduce waste, and enhance the quality of produced parts. This method relies on AI/ML models and optimization techniques, which are developed using the data collected from various sources, including in-situ sensors, ex-situ imaging, and manufacturing process parameters. The quality and diversity of this data, along with the alignment between different data streams (achieved through spatiotemporal registration) are critical for the successful development of AI/ML and optimization models. In this work, we present a spatiotemporally registered dataset generated during the WAAM process of deposition of a rectangular block. The dataset includes the comprehensive description of deposition process, process parameters, in-situ collected welding characteristics, acoustic data, and X-Ray Computed Tomography analysis data for the build. Dataset A Co-Registered In-Situ and Ex-Situ Dataset of Electrical, Acoustic, and CT Characteristics from Wire Arc Additive Manufacturing Process has arisen under UT-Battelle, LLC’s Prime Contract No. DE-AC05-00OR22725 with the U.S. Department of Energy (DOE) to manage and operate the Oak Ridge National Laboratory. UT-Battelle, LLC will not assert any rights under United States law or under the Prime Contract it has in the dataset against any user of the dataset, including any copyrights or patent rights. UT-Battelle, LLC requests that attribution to the dataset is provided as academically appropriate.

42 ENGINEERING↗

Quantitative Imaging of Cobalt Phthalocyanine Distribution on Carbon Nanotubes: A Deep Learning Approach to Catalyst Characterization

Electrochemical reduction of carbon dioxide (CO 2 ) offers a pathway to valuable products, with catalysts playing a crucial role. This study investigates the distribution of cobalt tetraaminophthalocyanine (CoPc-NH 2 ) immobilized on carbon nanotubes (CNTs), utilizing high-angle annular dark-field scanning transmission electron microscopy (HAADF-STEM) to characterize CoPc-NH 2 distribution. A challenge in the quantitative HAADF-STEM analysis is the introduction of bias from manual Co atom identification. To address this, we developed and trained a convolutional neural network (CNN) using a data set generated from images of CoPc-NH 2 /CNT samples with varying Co loadings. The CNN, implemented in TensorFlow and Keras, facilitated Co atom detections. Analysis of the CNN-generated data confirmed a correlation between Co loading and surface density, consistent with findings from UV–vis spectroscopy. Furthermore, the application of Ripley’s L(d) function highlighted the presence of slight Co atom clustering. Furthermore, this work demonstrates the utility of the combined HAADF-STEM and CNN approach for providing spatially resolved information about catalyst distribution on nonplanar supports, revealing structural details that are typically lost through other characterization methods.

HAADF-STEM↗

Impact of Concurrent Solubilization and Fines Migration on Fracture Aperture Growth in Shales during Acidized Brine Injection

Acidic hydraulic fracturing fluid chemically and physically alters shale rock fabric during injection and shut-in, creating a “reaction-altered zone” along the fracture faces. To better characterize the variable thickness and composition of this reaction-altered zone under advective flow, we take a coupled experimental and modeling approach. A fluidic cell, with six fiducial markers, is first fabricated to keep the rock sample in place during the core floods and to allow image alignment of acquired images. Then, we conduct a series of reactive core floods in a clay-rich siliceous Wolfcamp shale sample with 10 wt % carbonate, using a synthetic fracturing fluid under no confining stress and at room temperature. High-resolution computed tomography (CT) scans are periodically conducted to observe the spatial alteration of the fracture network. We then perform scanning electron microscopy (SEM-EDS) on the two orthogonal surfaces (fracture surface and freshly cut profile face) to generate high-resolution elemental maps that show the change in mineralogy, both with distance along a given flow path along a fracture surface and with depth from the fracture surface into the shale matrix. These results are contrasted against a two-dimensional (2D) advection-diffusion reaction model developed previously for batch reactions between shale and synthetic fracturing fluids. The model simulates the geochemical interaction occurring at the fracture/matrix interface and penetrating into the shale matrix during the reactive core flood. Both model and experimental results show that the acidic brine is neutralized during the core flood, corresponding to an increase in fracture aperture as a function of fluid volume injected with the greatest change near the inlet. SEM-EDS scans reveal significant dissolution of carbonates on the fracture surface without pyrite oxidation. The reactive transport model indicates that carbonate depletion into the shale interior should be observable, yet SEM-EDS shows no discernible loss of carbonate in the orthogonal profile face. The combination of these observations suggests an additional fracture evolution mechanism in the reactive system, i.e., fines migration. We show that fines migration enhances the access of fracturing fluid to the matrix resulting in a more pronounced fracture widening. Finally, we conclude that coupled mineral dissolution and fines migration govern fracture aperture growth during acidized brine injection. In this work, we effectively show the underlying risk of relying solely on models that do not include an important (transport) process that can alter the system significantly and propose a combined chemomechanical mechanism for fracture evolution appropriate for this shale mineralogy.

58 GEOSCIENCES↗

Advanced Instrumentation for Metal Additive Manufacturing

Laser powder bed fusion (LPBF) is the most widely used process for metal additive manufacturing (AM), particularly where complex geometries provide performance advantages unattainable with traditional manufacturing techniques. However, LPBF is highly sensitive to innate variability in both the powder spreading and fusion steps, often leading to defects such as pores that are difficult to detect yet significantly impair component mechanical properties and fatigue life. This thesis presents a range of novel instruments enabling both precise assessment of powder layer characteristics and in-situ thermal metrology of metal AM to advance the quality control of LPBF. First, leveraging a custom X-ray microscope and a radiation-transport model developed through this work, transmission X-ray imaging is used to study spreading of thin metal powder layers. Effective layer depth is directly mapped at a process-relevant size scale, surpassing optical techniques that can only estimate local deposition from layer surface topography. Layer packing density and quality are shown to be influenced by powder flowability and particle size relative to nominal powder layer thickness. Layer quality is additionally connected to the geometry of the spreading implement and its velocity. This technique and its presented findings enable pairing feedstocks with spreading strategies that create layers with consistent packing density and uniformity. Second, a twofold approach is employed to optically interrogate the laser fusion step of LPBF for observing signatures of defect formation. Aperture division multiplexing is conceptualized, providing for simultaneous laser delivery and high-fidelity infrared (IR) process monitoring through a common optic. In-situ microscopy at 50 μm spatial resolution and at mid-wave IR wavelengths is proven readily achievable with the first purpose-built optic of this type. Next, a bespoke imaging spectrometer, along with a temperature-emissivity separation technique, is used to retrieve accurate process temperatures over a 1000 K range. Data from these instruments are correlated to porosity as fine as 4.3 μm in two LPBF test artifacts, as verified using computed tomography (CT), establishing the viability of robust optically-based component qualification.

Penny, Ryan↗

Limited-view Cone Beam CT reconstruction using 3D Patch-based Supervised and Adversarial Learning [Slides]

We present a novel machine learning CNN architecture that can learn from limited data combined appropriately with physics and statistical priors (e.g., forward models and noise models). To address the limited availability of training data we adopt a 3D patch-based approach for our models. Patch-based learning is central to several image reconstruction methods and demands fewer training data than DL approaches, as a single data volume can be broken into several millions of overlapping 3D sub-volumes or patches. This creates a very large number of training sub-volumes from a limited number of overall image volumes. A 3D Generative Adversarial Networks (GAN) is then trained to remove artifacts at the sub-volume level. The combination of a sub-volume-based approach with DL allows us to exploit the richness of the latter in extracting and representing image features, while avoiding risks associated with overfitting due to limited training data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Domain Shift Analysis in Chest Radiographs Classification in a Veterans Healthcare Administration Population

This study aims to assess the impact of domain shift on chest X-ray classification accuracy and to analyze the influence of ground truth label quality and demographic factors such as age group, sex, and study year. We used a DenseNet121 model pre-trained MIMIC-CXR dataset for deep learning-based multi-label classification using ground truth labels from radiology reports extracted using the CheXpert and CheXbert Labeler. We compared the performance of the 14 chest X-ray labels on the MIMIC-CXR and Veterans Healthcare Administration chest X-ray dataset (VA-CXR). The validation of ground truth and the assessment of multi-label classification performance across various NLP extraction tools revealed that the VA-CXR dataset exhibited lower disagreement rates than the MIMIC-CXR datasets. Additionally, there were notable differences in AUC scores between models utilizing CheXpert and CheXbert. When evaluating multi-label classification performance across different datasets, minimal domain shift was observed in the unseen VA dataset, except for the label “Enlarged Cardiomediastinum.” The subgroup with the most significant variations in multi-label classification performance was study year. These findings underscore the importance of considering domain shift in chest X-ray classification tasks, paying particular attention to the temporality of the exam. Our study reveals the significant impact of domain shift and demographic factors on chest X-ray classification, emphasizing the need for improved transfer learning and robust model development. Addressing these challenges is crucial for advancing medical imaging research and improving patient care.

chest X-ray image classification↗

Cross-Modal Guidance for Fast Diffusion-Based Computed Tomography

Diffusion models have emerged as powerful priors for solving inverse problems in computed tomography (CT). In certain applications, such as neutron CT, it can be expensive to collect large amounts of measurements even for a single scan leading to sparse data sets from which it is challenging to obtain high quality reconstructions even with diffusion models. One strategy to mitigate this challenge is to leverage a complementary, easily available imaging modality; however, such approaches typically require retraining the diffusion model with large datasets. In this work, we propose incorporating an additional modality without retraining the diffusion prior, enabling accelerated imaging of costly modalities. We further examine the impact of imperfect side modalities on cross-modal guidance. Our method is evaluated on sparse-view neutron computed tomography, where reconstruction quality is substantially improved by incorporating X-ray computed tomography of the same samples.

Efimov, Timofey [ORNL] (ORCID:000900090098471X)↗

In-situ monitoring of atomically dispersed Pt sites supported on OMS-2 during CO 2 activation

Atomically dispersed catalysts have drawn great interest lately, as they showcase a high density of active sites, selectivity, and high turnover frequencies in oxidation chemistry due to labile oxygen activation. In contrast, the applications of these catalysts have lagged in reduction reactions due to the ambiguity caused by the sintering and restructuring of active sites. To bridge this gap, the evolution of Pt 4+ isomorphically substituted into an octahedral molecular sieve structure (OMS-2) under reductive conditions was correlatively characterized using multiple in-situ analytical techniques such as ambient pressure X-ray photoelectron spectroscopy, environmental transmission electron microscopy, and solid-state nuclear magnetic resonance. The surface dynamics of the Pt single atoms were revealed during the Reverse Water Gas Shift (RWGS) reaction, where the active sites were identified as two-coordinated platinum single atoms. Under reaction, we show nonbinding atoms adjacent to the single atoms restructured the motif of the single atoms to Pt 2+ via ion mobility of potassium, increasing the activation energy by 25.6 kJ/mol. Here, this work also highlights the potential for increased stability of the single atom sites via isomorphic substitution of the metal oxide support, since the Pt-OMS-2 catalyst retained activity for about 33 h before deactivation, after which nanoparticles were observed in TEM images. This work offers a new perspective in single atom synthesis using the metal oxide as the host for the single atom site, instead of adatoms on the surface

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TRINIDI (Time-of-Flight Resonance Imaging with Neutrons for Isotopic Density Inference)

This software is an open-source Python library that provides tools for processing hyperspectral neutron time-of-flight radiography data. This type of data allows material decomposed reconstructions to be generated with the use of material characteristic spectral responses and the algorithms provided in this code library. The software library will contain tools for pre-processing the neutron measurement data, estimating measurement system parameters, reconstructing material decomposed radiographs, and computing material decomposed computed tomography (CT). Furthermore, it will have capability to generate and process simulated neutron time-of-flight data with the goal of benchmarking and demonstrating the tools that are provided. The software will include thorough documentation and application examples.

Balke, Thilo↗