Search NASA⌕ Search

SEARCH · Search NASA

Results for “Capacity estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Instantaneous mental workload - Concept and potential methods for measurement

This paper provides an initial conceptual framework for instantaneous workload and describes potential methods for short-term measurement. Many existing estimation techniques can be modified for use as short-term assessment techniques. Techniques in the (1) opinion, (2) spare mental capacity, (3) primary task, and (4) physiological categories are discussed. The limitations involved in instantaneous workload, which are real and fundamental, are also described.

Wierwille, W. W.↗

Distribution of human waste samples in relation to sizing waste processing in space

Human waste processing for closed ecological life support systems (CELSS) in space requires that there be an accurate knowledge of the quantity of wastes produced. Because initial CELSS will be handling relatively few individuals, it is important to know the variation that exists in the production of wastes rather than relying upon mean values that could result in undersizing equipment for a specific crew. On the other hand, because of the costs of orbiting equipment, it is important to design the equipment with a minimum of excess capacity because of the weight that extra capacity represents. A considerable quantity of information that had been independently gathered on waste production was examined in order to obtain estimates of equipment sizing requirements for handling waste loads from crews of 2 to 20 individuals. The recommended design for a crew of 8 should hold 34.5 liters per day (4315 ml/person/day) for urine and stool water and a little more than 1.25 kg per day (154 g/person/day) of human waste solids and sanitary supplies.

Parker, Dick↗

Exploration of Terminal Procedures Enabled by NASA Wake VAS Technologies

The National Aeronautics and Space Administration (NASA) tasked The MITRE Corporation's Center for Advanced Aviation System Development (CAASD) to investigate potential air traffic control (ATC) procedures that could benefit from technology used or developed in NASA's Wake Vortex Advisory System (WakeVAS). The task also required developing an estimate of the potential benefits of the candidate procedures. The main thrust of the investigation was to evaluate opportunities for improved capacity and efficiency in airport arrival and departure operations. Other procedures that would provide safety enhancements were also considered. The purpose of this investigation was to provide input to the WakeVAS program office regarding the most promising areas of development for the program. A two-fold perspective was desired: First, identification of benefits from possible procedures enabled by both incremental components and the mature state of WakeVAS technology; second identification of procedures that could be expected to evolve from the current Federal Aviation Administration (FAA) procedures. The evolution of procedures should provide meaningful increments of benefit and a low risk implementation of the WakeVAS technologies.

Lunsford, Clark R.↗

Estimation of soil moisture from diurnal surface temperature observations

A coupled heat and moisture balance model was used to determine the thermal inertia of a grass covered top soil under different meteorological conditions. Relations between thermal inertia and soil moisture were established using the De Vries models for thermal conductivity and heat capacity to relate soil moisture and thermal inertia as a function of soil type. A sensitivity study of the surface roughness length and thermal inertia on diurnal surface temperature shows the necessity of focusing on the night time surface temperature rather than on the day time surface temperature, in order to estimate the soil moisture content of the top soil.

Vandegriend, A. A.↗

A fast algorithm for control and estimation using a polynomial state-space structure

One of the major problems associated with the control of flexible structures is the estimation of system states. Since the parameters of the structures are not constant under varying loads and conditions, conventional fixed parameter state estimators can not be used to effectively estimate the states of the system. One alternative is to use a state estimator which adapts to the condition of the system. One such estimator is the Kalman filter. This filter is a time varying recursive digital filter which is based upon a model of the system being measured. This filter adapts the model according to the output of the system. Previously, the Kalman filter has only been used in an off-line capacity due to the computational time required for implementation. With recent advances in computer technology, it is becoming a viable tool for use in the on-line environment. A distributed Kalman filter implementation is described for fast estimation of the state of a flexible arm. A key issue, is the sensor structure and initial work on a distributed sensor that could be used with the Kalman filter is presented.

Shults, James R.↗

The thermodynamic properties of oxygen and nitrogen. Part 2: Thermodynamic properties of oxygen from 100 R to 600 R with pressure to 5000 psia

An equation of state is presented for liquid and gaseous oxygen for temperatures from 100 R to 600 R and pressures to 5000 psia. The pressure-density-temperature data available from the published literature have been reviewed, and appropriate corrections have been applied to bring experimental temperatures into accord with the International Practical Temperature Scale of 1968. Representative comparisons of property values calculated from the equation of state to measured values are included to illustrate the accuracy of the equation of state. The coefficients of the equation of state were determined by a weighted least squares fit to selected published data, and simultaneously to isochoric heat capacity data, and to data which define the phase equilibrium for the saturated liquid and saturated vapor. The equation of state is estimated to be accurate for the liquid to within 0.1 percent in density, to within 0.2 percent for the vapor below the critical temperature and for states above the critical temperatures to 250 K, and within 0.1 percent for supercritical states at temperatures from 250 K to 300 K. The vapor pressure equation is accurate to within + or - 0.01 K between the triple point and the critical point.

Stewart, R. B.↗

Energy Conservation Alternatives Study (ECAS): Conceptual Design and Implementation Assessment of a Utility Steam Plant with Conventional Furnace and Wet Lime Stack Gas Scrubbers

A study was performed to estimate the technical/economic characteristics of a steam power plant (3500 pounds per square inch gauge, 1000 degrees Fahrenheit / 1000 degrees Fahrenheit) with a coal-burning radiant furnace and a wet lime stack gas scrubber to control sulfur emissions. Particulate emissions were controlled by an electrostatic precipitator operating at 300 degrees Fahrenheit. The stack gas from the scrubber was reheated from 125 degrees Fahrenheit to 250 degrees Fahrenheit as a base case, and from 125 degrees Fahrenheit to 175 degrees Fahrenheit as an alternate case. The study was performed on a basis consistent with the General Electric ECAS Phase II evaluation of advanced energy conversion systems for electric utility baseload applications using coal or coal-derived fuels. A conceptual design of the power plant was developed, including the on-site calcination of limestone to lime and the provision of sludge ponds to store the products of flue gas scrubbing. From this design, estimates were derived for power plant efficiency, capital cost, environmental intrusion characteristics, natural resource requirements, and cost of electricity at an assumed capacity factor of 65 percent. An implementation assessment was performed where factors affecting applicability of the conceptual design power plant in electric utility generation systems were appraised. At 250 degrees Fahrenheit and 175 degrees Fahrenheit stack gas temperatures respectively, the plants showed a cost of electricity of 39.8 and 37.0 mills per kilowatt-hours and overall plant efficiencies of 32 percent and 34 percent.

Brown, Dale H.↗

The effect of atmospheric drag on the design of solar-cell power systems for low Earth orbit

The feasibility of reducing the atmospheric drag of low orbit solar powered satellites by operating the solar-cell array in a minimum-drag attitude, rather than in the conventional Sun pointing attitude was determined. The weights of the solar array, the energy storage batteries, and the fuel required to overcome the drag of the solar array for a range of design life times in orbit were considered. The drag of the array was estimated by free molecule flow theory, and the system weights were calculated from unit weight estimates for 1990 technology. The trailing, minimum drag system was found to require 80% more solar array area, and 30% more battery capacity, the system weights for reasonable life times were dominated by the thruster fuel requirements.

Kyser, A. C.↗

Capsulation Satellite or CapSat: A Low-Cost, Reliable, Rapid-Response Spacecraft Platform

The National Aeronautics and Space Administration (NASA) Goddard's Rideshare Office estimates that between 2013 and 2022, NASA launches of primary satellites will have left unused more than 20,371 kilograms of excess capacity. This equates to hundreds of millions of dollars in launch-vehicle costs going unutilized. To fill this void with a standard CubeSat or SmallSat spacecraft platform, which when required to be more reliable, still will cost in the neighborhood of $1M a kilogram, making it prohibitively expensive. A newly proposed solution, which NASA is pursuing, is called the Capsulation Satellite or CapSat. CapSat is a modularized, pressurized, thermally controlled spacecraft designed to host ruggedized commercially available instrumentation in a terrestrial like environment on orbit. Using a technique that is under review for a patent, CapSat actively manages internal air temperatures in a manner similar to a household thermostat. This gives CapSat high-thermal stability, which, in turn, provides component longevity. CapSat was specifically designed to take advantage of the United States Air Force (USAF) Rideshare Program and the Evolved Expendable Launch Vehicle Secondary Payload Adaptor, or ESPA ring. The ESPA ring comes in two sizes: standard and Grande. CapSat primarily will take advantage of the ESPA Grande to provide a 300-kilogram payload capability per attachment point, with up to four attachment points per ring. This approach combines a high-mass capability with a proven Rideshare mechanical interface and secondary payload management infrastructure. Opportunities for ESPA based co-manifests are continuing to expand. The CapSat program is currently funded to design and build a limited prototype and perform thermal-vacuum testing. CapSat is currently in the concept/study phase for both single missions and constellation of earth- and space-observing missions. One of these studies includes land imaging using state-of-the-art advanced infrared detector technology. This paper will report on the current status of the CapSat hardware design, testing, and results as well as any openly available advanced concept study results. The CapSat solution is intended to be a game-changing paradigm shift. CapSat will repurpose currently available, already-proven technology to reduce spaceflight hardware costs to less than $50,000 per kilogram.

Burt, Joe↗

Atmospheric helium and geomagnetic field reversals.

The problem of the earth's helium budget is examined in the light of recent work on the interaction of the solar wind with nonmagnetic planets. It is proposed that the dominant mode of helium (He4) loss is ion pumping by the solar wind during geomagnetic field reversals, when the earth's magnetic field is very small. The interaction of the solar wind with the earth's upper atmosphere during such a period is found to involve the formation of a bow shock. The penetration altitude of the shock-heated solar plasma is calculated to be about 700 km, and ionization rates above this level are estimated for a cascade ionization (electron avalanche) process to average 10 to the 9th power ions/sq cm/sec. The calculated ionization rates and the capacity of the solar wind to remove ionized helium (He4) from the upper atmosphere during geomagnetic dipole reversals are sufficient to yield a secular equilibrium over geologic time scales. The upward transport of helium from the lower atmosphere under these conditions is found to be adequate to sustain the proposed loss rate.

Sheldon, W. R.↗

The Dynairship

A feasibility analysis for the construction and use of a combination airplane-airship named 'Dynairship' is undertaken. Payload capacities, fuel consumption, and the structural design of the craft are discussed and compared to a conventional commercial aircraft (a Boeing 747). Cost estimates of construction and operation of the craft are also discussed. The various uses of the craft are examined (i.e, in police work, materials handling, and ocean surveillance), and aerodynamic configurations and photographs are shown.

Miller, W. M., Jr.↗

An integrated study of earth resources in the state of California using remote sensing techniques

The author has identified the following significant results. The effects on estimates of monthly volume runoff were determined separately for each of the following parameters: precipitation, evapotranspiration, lower zone and upper zone tension water capacity, imperviousness of the watershed, and percent of the watershed occupied by riparian vegetation, streams, and lakes. The most sensitive and critical parameters were found to be precipitation during the entire year and springtime evapotranspiration.

Colwell, R. N.↗

Design and calculated performance and cost of the ECAS Phase II open cycle MHD power generation system

A 2000 MWe MHD/steam plant for central station applications has been designed and costed as part of the Energy Conversion Alternatives Study (ECAS). This plant is fueled by Illinois No. 6 coal, rejects heat through mechanical draft wet cooling towers, and includes coal processing equipment, seed reprocessing, electrical inversion of the MHD generator output and emission controls to current EPA standards. It yields an estimated overall efficiency of 0.483 (7066 Btu/kWe-hr), a capital cost of $718 per kWe (1975 dollars), and a cost of electricity at 65% capacity factor of 32 mills per kWe-hr. If the assumed life and reliability could be achieved with these performance parameters, the MHD system should prove attractive.

Harris, L. P.↗

Changes of instability thresholds of rotor due to bearing misalignments

The influence of bearing misalignment upon the dynamic characteristics of statistically indeterminant rotor bearing systems is investigated. Both bearing loads and stability speed limits of a rotor may be changed significantly by magnitude and direction of bearing misalignment. The useful theory of short journal bearings is introduced and simple analytical expressions, governing the misalignment problem, are carried out. Polar plots for the bearing load capacities and stability maps, describing the speed limit in terms of misalignment, are presented. These plots can be used by the designer to estimate deviations between calculation and experimental data due to misalignment effects.

Springer, H.↗

DS-2 Mars Microprobe Battery

In January of 1999 the NM DS-2 Mars microprobe will be launched to impact on Mars in December. The technical objectives of the missions are to demonstrate: key technologies, a passive atmospheric entry, highly integrated microelectronics which can withstand both low temperatures and high decelerations, and the capability to conduct in-situ, surface and subsurface science data acquisition. The scientific objectives are to determine if ice is present below the Martian surface, measure the local atmospheric pressure, characterize the thermal properties of the martian subsurface soil, and to estimate the vertical temperature gradient of the Martian soil. The battery requirements are 2-4 cell batteries, with voltage of 6-14 volts, capacity of 550 mAh at 80C, and 2Ah at 25C, shelf life of 2.5 years, an operating temperature of 60C and below, and the ability to withstand shock impact of 80,000 g's. The technical challenges and the approach is reviewed. The Li-SOCL2 system is reviewed, and graphs showing the current and voltage is displayed, along with the voltage over discharge time. The problems encountered during the testing were: (1) impact sensitivity, (2) cracking of the seals, and (3) delay in voltage. A new design resulted in no problems in the impact testing phase. The corrective actions for the seal problems involved: (1) pre weld fill tube, (2) an improved heat sink during case to cover weld and (3) change the seal dimensions to reduce stress. To correct the voltage delay problem the solutions involved: (1) drying the electrodes to reduce contamination by water, (2) assemblage of the cells within a week of electrode manufacture, (3) ensure electrolyte purity, and (4) provide second depassivation pulse after landing. The conclusions on further testing were that the battery can: (1) withstand anticipated shock of up to 80,000 g, (2) meet the discharge profile post shock at Mars temperatures, (3) meet the required self discharge rate and (4) meet environmental requirements.

Frank, H.↗

Two-Phase Cryogenic Heat Exchanger for the Thermodynamic Vent System

A two-phase cryogenic heat exchanger for a thermodynamic vent system was designed and analyzed, and the predicted performance was compared with test results. A method for determining the required size of the Joule-Thomson device was also developed. Numerous sensitivity studies were performed to show that the design was robust and possessed a comfortable capacity margin. The comparison with the test results showed very similar heat extraction performance for similar inlet conditions. It was also shown that estimates for Joule- Thomson device flow rates and exit quality can vary significantly and these need to be accommodated for with a robust system design.

Christie, Robert J.↗

Satellite estimation of the surface energy balance, moisture availability and thermal inertia

A method for inferring the distribution of surface heat and evaporative fluxes and the ground moisture availability and thermal inertia (ground conductive capacity) is used to analyze two urbanized areas, Los Angeles and St. Louis. The technique employs infrared satellite temperature measurements in conjunction with a one-dimensional boundary-layer model. Results show that there is a marked reduction of evaporation and moisture availability and a corresponding elevation of sensible heat flux over urbanized areas and over cropped areas with low vegetative cover. Conversely, low heat flux and high evaporation characterize vegetated and, especially, forested areas. Warm urban centers appear directly related to a reduction in vegetation, which normally allows for a greater fraction of available radiant energy to be converted into latent heat flux. The distribution of thermal inertia was surprisingly ill-defined and its variation between urban and rural areas was quite small. Thus, the increased heat storage within the urban fabric, which has been proposed as the underlying cause of the nocturnal heat island, may be caused mainly by enhanced daytime surface heating which occurs because of surface dryness, rather than by large spatial variations in the conductivity of the surface.

Carlson, T. N.↗

Estimation of cardiac reserve by peak power: validation and initial application of a simplified index

OBJECTIVES: To validate a simplified estimate of peak power (SPP) against true (invasively measured) peak instantaneous power (TPP), to assess the feasibility of measuring SPP during exercise and to correlate this with functional capacity. DESIGN: Development of a simplified method of measurement and observational study. SETTING: Tertiary referral centre for cardiothoracic disease. SUBJECTS: For validation of SPP with TPP, seven normal dogs and four dogs with dilated cardiomyopathy were studied. To assess feasibility and clinical significance in humans, 40 subjects were studied (26 patients; 14 normal controls). METHODS: In the animal validation study, TPP was derived from ascending aortic pressure and flow probe, and from Doppler measurements of flow. SPP, calculated using the different flow measures, was compared with peak instantaneous power under different loading conditions. For the assessment in humans, SPP was measured at rest and during maximum exercise. Peak aortic flow was measured with transthoracic continuous wave Doppler, and systolic and diastolic blood pressures were derived from brachial sphygmomanometry. The difference between exercise and rest simplified peak power (Delta SPP) was compared with maximum oxygen uptake (VO(2)max), measured from expired gas analysis. RESULTS: SPP estimates using peak flow measures correlated well with true peak instantaneous power (r = 0.89 to 0.97), despite marked changes in systemic pressure and flow induced by manipulation of loading conditions. In the human study, VO(2)max correlated with Delta SPP (r = 0.78) better than Delta ejection fraction (r = 0.18) and Delta rate-pressure product (r = 0.59). CONCLUSIONS: The simple product of mean arterial pressure and peak aortic flow (simplified peak power, SPP) correlates with peak instantaneous power over a range of loading conditions in dogs. In humans, it can be estimated during exercise echocardiography, and correlates with maximum oxygen uptake better than ejection fraction or rate-pressure product.

Non-NASA Center↗