Search NASA⌕ Search

SEARCH · Search NASA

Results for “Casting Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Magnetostrictive loss reduction through stress relief annealing in an FeNi-based metal amorphous nanocomposite

FeNi-based metal amorphous nanocomposite alloys are emerging soft magnetic materials with promise for high-speed motor applications. Here we demonstrate a technique to optimize magnetic properties in toroidal cores wound from strain annealed (Fe 70 Ni 30 ) 80 Nb 4 Si 2 B 14 amorphous metal ribbon (AMR). In-line strain annealing (SA) of the AMR yields a strip permeability that monotonically decreases with increasing SA tensions. After winding into toroidal cores, dramatic changes in magnetic properties are observed and determined to be of magnetostrictive origin. A procedure to re-anneal wound toroidal cores to reduce hysteresis and reverse magnetostrictive effects is developed inclusive of casting curvature effects. Here, we investigate re-annealing temperatures between 300 – 470 °C for cores produced from each SA condition. Magnetic core loss, W L , coercivity, H c , squareness ratio, K r , and permeability, µ r , are measured as a function of (stress relief) re-annealing temperature to optimally achieve W 1T,400Hz = 0.51 W/kg, H c = 2.42 A/m, K r = 0.22, and µ r = 35,300.

36 MATERIALS SCIENCE↗

A grating-based single-shot x-ray phase contrast and diffraction method for in vivo imaging

Purpose: The purpose of this study is to develop a single-shot version of the grating-based phase contrast x-ray imaging method and demonstrate its capability of in vivo animal imaging. Here, the authors describe the principle and experimental results. They show the source of artifacts in the phase contrast signal and optimal designs that minimize them. They also discuss its current limitations and ways to overcome them. Methods: A single lead grid was inserted midway between an x-ray tube and an x-ray camera in the planar radiography setting. The grid acted as a transmission grating and cast periodic dark fringes on the camera. The camera had sufficient spatial resolution to resolve the fringes. Refraction and diffraction in the imaged object manifested as position shifts and amplitude attenuation of the fringes, respectively. In order to quantify these changes precisely without imposing a fixed geometric relationship between the camera pixel array and the fringes, a spatial harmonic method in the Fourier domain was developed. The level of the differential phase (refraction) contrast as a function of hardware specifications and device geometry was derived and used to guide the optimal placement of the grid and object. Both ex vivo and in vivo images of rodent extremities were collected to demonstrate the capability of the method. The exposure time using a 50 W tube was 28 s. Results: Differential phase contrast images of glass beads acquired at various grid and object positions confirmed theoretical predictions of how phase contrast and extraneous artifacts vary with the device geometry. In anesthetized rats, a single exposure yielded artifact-free images of absorption, differential phase contrast, and diffraction. Differential phase contrast was strongest at bone-soft tissue interfaces, while diffraction was strongest in bone. Conclusions: The spatial harmonic method allowed us to obtain absorption, differential phase contrast, and diffraction images, all from a single raw image and is feasible in live animals. Because the sensitivity of the method scales with the density of the gratings, custom microfabricated gratings should be superior to off-the-shelf lead grids.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Matrimid substrates with bicontinuous surface and macrovoids in the bulk: A nearly ideal substrate for composite membranes in CO 2 capture

Scalable fabrication of thin-film composite (TFC) membrane for post-combustion carbon capture is often limited by the availability of high-performance nanoporous substrate. Ideally, the substrate should allow for fast gas transport at the selective layer/substrate interface as well as in the bulk of the substrate. In this study, highly permeable Matrimid substrates were prepared via vapor- and nonsolvent-induced phase separations. The phase separation mechanism of the Matrimid®/N-methyl-2-pyrrolidone casting solution was modulated by the addition of LiCl to control the solution thermodynamic stability, and nanoporous Matrimid substrates were formed with a bicontinuous surface and macrovoids in the bulk. This hierarchically optimized structure resulted in a CO 2 permeance of 2.60 × 10 5 GPU (1 GPU = 1 × 10 –6 cm 3 (STP) cm –2 s –1 cmHg –1 = 3.349 × 10 –10 mol m –2 s –1 Pa –1 ), which was ca. 11 times more permeable than a benchmark polyethersulfone substrate with cellular pores. The benefit of using this new substrate was demonstrated by coating a 170-nm amine-containing polymer to form a TFC facilitated transport membrane. The membrane exhibited a CO 2 permeance of 932 GPU at 57°C, which was 72 GPU higher than the counterpart coated on the benchmark substrate. Meanwhile, the CO 2 /N 2 selectivity was remained at 158. This permeance improvement could be well explained by the resistance-in-series model, where the improved permeance was attributed to the reductions in substrate and lateral diffusion mass transfer resistances. The upper bound (UB) analysis indicates that the Matrimid substrate is nearly ideal for the state-of-the-art polymers for CO 2 /N 2 separation. Here, the substrate improvement could also reduce the parasitic energy associated with the membrane process due to the reduced membrane cost and flue gas compression requirement.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Global solutions of restricted open-shell Hartree-Fock theory from semidefinite programming with applications to strongly correlated quantum systems

We present a density matrix approach for computing global solutions of restricted open-shell Hartree-Fock theory, based on semidefinite programming (SDP), that gives upper and lower bounds on the Hartree-Fock energy of quantum systems. While wave function approaches to Hartree-Fock theory yield an upper bound to the Hartree-Fock energy, we derive a semidefinite relaxation of Hartree-Fock theory that yields a rigorous lower bound on the Hartree-Fock energy. We also develop an upper-bound algorithm in which Hartree-Fock theory is cast as a SDP with a nonconvex constraint on the rank of the matrix variable. Equality of the upper- and lower-bound energies guarantees that the computed solution is the globally optimal solution of Hartree-Fock theory. The work extends a previously presented method for closed-shell systems [S. Veeraraghavan and D. A. Mazziotti, Phys. Rev. A 89, 010502–R (2014)]. For strongly correlated systems the SDP approach provides an alternative to the locally optimized Hartree-Fock energies and densities with a certificate of global optimality. Applications are made to the potential energy curves of C{sub 2}, CN, Cr {sub 2}, and NO {sub 2}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Miscibility-Function Relations in Organic Solar Cells: Significance of Optimal Miscibility in Relation to Percolation

Polymer solar cells (PSCs) continue to be a promising low-cost and lead-free photovoltaic technology. Of critical importance to PSCs is understanding and manipulating the composition of the amorphous mixed phase, which is governed by the thermodynamic molecular interactions of the polymer donor and acceptor molecules and the kinetics of the casting process. This progress report clarifies and defines nomenclature relating to miscibility and its relevance and implications to PSC devices in light of new developments. Utilizing a scanning transmission X-ray microscopy method, the temperature dependences of “molecular miscibility” in the presence of fullerene crystals, now referred to liquidus miscibility, are presented for a number of representative blends. An emphasis is placed on relating the amorphous miscibility of high-efficiency PSC blends at a given processing temperature with their actual device performance and stability. It is shown and argued that a system with an amorphous miscibility close to percolation exhibits the most stable morphology. Furthermore, an approach is outlined to convert liquidus miscibility to an effective Flory–Huggins interaction parameter χ. Crucially, determination of temperature-dependent amorphous miscibility paves a way to rationally optimize the stability and mixing behaviors of PSCs at actual processing and operating temperatures.

14 SOLAR ENERGY↗

Data-driven projection pursuit adaptation of polynomial chaos expansions for dependent high-dimensional parameters

Uncertainty quantification (UQ) and inference involving a large number of parameters are valuable tools for problems associated with heterogeneous and non-stationary behaviors. The difficulty with these problems is exacerbated when these parameters are statistically dependent requiring statistical characterization over joint measures. Probabilistic modeling methodologies stand as effective tools in the realms of UQ and inference. Among these, polynomial chaos expansions (PCE), when adapted to low-dimensional quantities of interest (QoI), provide effective yet accurate approximations for these QoI in terms of an adapted orthogonal basis. These adaptation techniques have been cast as projection pursuits in Gaussian Hilbert space in what has been referred to as a projection pursuit adaptation (PPA) by Xiaoshu Zeng and Roger Ghanem (2023). The PPA method efficiently identifies an optimal low-dimensional space for representing the QoI and simultaneously evaluates an optimal PCE within that space. The quality of this approximation clearly depends on the size of the training dataset, which is typically a function of the adapted reduced dimension. Here, the complexity of the problem is thus mediated by the complexity of the low-dimensional quantity of interest and not the complexity of the high-dimensional parameter space.

Data-driven↗

4D Imaging of ZnO-Coated Nanoporous Al 2 O 3 Aerogels by Chemically Sensitive Ptychographic Tomography: Implications for Designer Catalysts

The 3D chemical structure (4D spectromicroscopy) of nanoporous Al 2 O 3 aerogels coated with ZnO by atomic layer deposition (ALD) was studied by multienergy scanning transmission X-ray microscopy. These materials are representative of a class of designer catalysts in which the nanoporous support is prepared separately from the active catalyst material, which is subsequently introduced by ALD, thereby allowing independent optimization of the morphology, chemistry, and spatial distribution of the support and catalyst. The samples studied were prepared by Ga ion and Xe plasma focused ion beam (FIB) milling as well as drop casting from water suspension. Zn L and Al K edge spectra of six samples with three different ZnO loadings were measured to investigate how loading and different sample preparation methods affect the 3D distribution of the ZnO and Al 2 O 3 . Scanning transmission X-ray microscopy (STXM) and ptychographic imaging at two energies each at the Zn L 3 and Al K edge were measured. The ptychography data were analyzed by using the SHARP reconstruction code to generate quantitative 2D chemical maps of the Al 2 O 3 and the ZnO. The STXM and ptychography maps were then measured at a sequence of tilt angles, covering up to 160° of rotation. The 3D structure of the ZnO and Al 2 O 3 was derived from the tilt series data by tomographic reconstruction using a compressed sensing algorithm. A twodimensional spatial resolution (half-period) of 6 nm, measured by Fourier ring correlation, and a 3D spatial resolution (half-period) of 9 nm, measured by Fourier shell correlation, were achieved when using the COSMIC beamline at the Advanced Light Source (ALS). The results show that for all of the ZnO loadings studied there is nonuniform coverage of the ZnO on the Al 2 O 3 aerogel framework. In addition, we found that both FIB methods create sample artifacts, although the distortion was less with Xe plasma than Ga ion FIB.

36 MATERIALS SCIENCE↗

Quantitative Assessment of Image-Guided Radiotherapy for Paraspinal Tumors

Purpose: To evaluate stereotactic positioning uncertainties of patients with paraspinal tumors treated with fractionated intensity-modulated radiotherapy; and to determine whether target-point correction via rigid registration is sufficient for daily patient positioning. Patients and Methods: Forty-five patients with tumors at the cervical, thoracic, and lumbar spine received regular control computed-tomography (CT) scans using an in-room CT scanner. All patients were immobilized with the combination of Scotch cast torso and head masks. The positioning was evaluated regarding translational and rotational errors by applying a rigid registration algorithm based on mutual information. The registration box was fitted to the target volume for optimal registration in the high-dose area. To evaluate the suitability of the rigid registration result for correcting the target volume position we subsequently registered three small subsections of the upper, middle, and lower target volume. The resulting residual deviations reflect the extent of the elastic deformations, which cannot be covered by the rigid-body registration procedure. Results: A total of 321 control CT scans were evaluated. The rotational errors were negligible. Translational errors were smallest for cervical tumors (-0.1 +- 1.1, 0.3 +- 0.8, and 0.1 +- 0.9 mm along left-right, anterior-posterior, and superior-inferior axes), followed by thoracic (0.8 +- 1.1, 0.3 +- 0.8, and 1.1 +- 1.3 mm) and lumbar tumors (-0.7 +- 1.3, 0.0 +- 0.9, and 0.5 +- 1.6 mm). The residual deviations of the three subsections were <1 mm. Conclusions: The applied stereotactic patient setup resulted in small rotational errors. However, considerable translational positioning errors may occur; thus, on the basis of these data daily control CT scans are recommended. Rigid transformation is adequate for correcting the target volume position.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computational Design of a Novel Medium-Carbon, Low-Alloy Steel Microalloyed with Niobium

The design of a new steel with specific properties is always challenging owing to the complex interactions of many variables. In this work, this challenge is dealt with by combining metallurgical principles with computational thermodynamics and kinetics to design a novel steel composition suitable for thermomechanical processing and induction heat treatment to achieve a hardness level in excess of 600 HV with the potential for good fracture toughness. CALPHAD-based packages for the thermodynamics and kinetics of phase transformations and diffusion, namely Thermo-Calc{sup ®} and JMatPro{sup ®}, have been combined with an interdendritic segregation tool (IDS) to optimize the contents of chromium, molybdenum and niobium in a proposed medium-carbon low-manganese steel composition. Important factors taken into account in the modeling and optimization were hardenability and as-quenched hardness, grain refinement and alloying cost. For further investigations and verification, the designed composition, i.e., in wt.% 0.40C, 0.20Si, 0.25Mn, 0.90Cr, 0.50Mo, was cast with two nominal levels of Nb: 0 and 0.012 wt.%. The results showed that an addition of Nb decreases the austenite grain size during casting and after slab reheating prior to hot rolling. Validation experiments showed that the predicted properties, i.e., hardness, hardenability and level of segregation, for the designed composition were realistic. It is also demonstrated that the applied procedure could be useful in reducing the number of experiments required for developing compositions for other new steels.

36 MATERIALS SCIENCE↗

Deep Reinforcement Learning for Distribution System Restoration Using Distributed Energy Resources and Tie-Switches

Distributed energy resources (DERs), such as solar PVs and energy storage, can be used to restore distribution system critical loads after the extreme weather events to increase grid resilience. However, coordinating multiple DERs together with tie-switches for multi-step restoration process under renewable uncertainty is challenging. This paper proposes a deep reinforcement learning to control discrete actions of switching on/off tie switches and DERs for critical load restoration. The restoration problem is first cast into the Markov decision process suitable for DRL. Then, the original soft actor critic (SAC) method for continuous actions has been extended to handle discrete and continuous actions. Numerical comparison results with other stochastic optimization-based approaches on the modified IEEE 33-bus system show that the proposed method can achieve fast critical load restoration in the presence of substation power outage while maintaining system voltage limit throughout the restoration process.

active distribution systems↗

Sensitivity and variability of Presage dosimeter formulations in sheet form with application to SBRT and SRS QA

Purpose: To measure sensitivity and stability of the Presage dosimeter in sheet form for various chemical concentrations over a range of clinical photon energies and examine its use for stereotactic body radiation therapy (SBRT) and stereotactic radiosurgery (SRS) QA. Methods: Presage polymer dosimeters were formulated to investigate and optimize their sensitivity and stability. The dosimeter is composed of clear polyurethane base, leucomalachite green (LMG) reporting dye, and bromoform radical initiator in 0.9–1.0 mm thick sheets. The chemicals are mixed together for 2 min, cast in an aluminum mold, and left to cure at 60 psi for a minimum of two days. Dosimeter response was characterized at energies Co-60, 6 MV, 10 MV flattening-filter free, 15 MV, 50 kVp (mean 19.2 keV), and Ir-192. The dosimeters were scanned by a Microtek Scanmaker i800 at 300 dpi, 2{sup 16} bit depth per color channel. Red component images were analyzed with ImageJ and RIT. SBRT QA was done with gamma analysis tolerances of 2% and 2 mm DTA. Results: The sensitivity of the Presage dosimeter increased with increasing concentration of bromoform. Addition of tin catalyst decreased curing time and had negligible effect on sensitivity. LMG concentration should be at least as high as the bromoform, with ideal concentration being 2% wt. Gamma Knife SRS QA measurements of relative output and profile widths were within 2% of manufacturer’s values validated at commissioning, except the 4 mm collimator relative output which was within 3%. The gamma pass rate of Presage with SBRT was 73.7%, compared to 93.1% for EBT2 Gafchromic film. Conclusions: The Presage dosimeter in sheet form was capable of detecting radiation over all tested photon energies and chemical concentrations. The best sensitivity and photostability of the dosimeter were achieved with 2.5% wt. LMG and 8.2% wt. bromoform. Scanner used should not emit any UV radiation as it will expose the dosimeter, as with the Epson 10000 XL scanner. Presage dosimeter in this form was sensitive enough for use in SRS and SBRT QA. The lower gamma pass rate for Presage compared to Gafchromic film can be attributed to the simple equipment used in the fabrication process, which limited the dosimeter’s sensitivity uniformity by agglomeration of air bubbles in the material, nonuniform concentration of chemicals throughout the material, and thickness variations. This demands improvements in mixing tools and molds.

60 APPLIED LIFE SCIENCES↗

Design, Optimization, and Control of a 100 kW Electric Traction Motor Meeting or Exceeding DOE 2025 Targets

The overall objective of the electric motor portion of the Electric Drives Technology consortium is to research, develop, and test electric motors for use in electric vehicle applications capable of a peak power greater than 100 kW, power density greater than or equal to 50 kW/l, and a cost less than 3.3 $/kW. To meet the electric traction motor power density and cost targets a number of approaches were pursued simultaneously throughout the course of this project which address all of the major volumetric power density variables. The specific research thrusts at the Illinois Institute of Technology (IIT) are the following: multiphysics design for increased power density through maximum utilization of active materials, synthesis of electric machine windings and PM flux barriers with controlled space harmonics, high slot fill windings for increased current loadings or efficiency, aggressive cooling strategies, and design studies and prototype construction of candidate electric machines.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a Castable High Strength Secondary Aluminum Alloy from Recycled Wrought Aluminum Scrap

A new process for recycling scrap AA7075 aerospace alloys directly into a high strength castable secondary alloy is demonstrated. The process involves enhancing the castability of the utilized primary wrought aluminum scrap feedstock by scrap alloy chemistry optimization and zirconium additions in order to mitigate the inherent hot tearing tendency of 7075 alloys. By utilizing the new process, the hot tearing index of scrap AA7075 was reduced from 26 to 4. Defect-free castings were obtained in pilot-scale castings trials. The developed secondary 7075 alloy also satisfied preset target mechanical properties with strength levels exceeding 250 MPa and elongation levels higher than 3%. The validity of the new approach and its readiness for transition to commercial practice was demonstrated by casting cylinder heads directly from the modified 7075 scrap.

36 MATERIALS SCIENCE↗

Bipolar Membranes With Controlled, Microscale 3D Junctions Enhance the Rates of Water Dissociation and Formation

A soft lithographic method is developed for making bipolar membranes (BPMs) with catalytic junctions formed from arrays of vertically oriented microscale cylinders. The membranes are cast from reusable polydimethylsiloxane (PDMS) molds made from silicon masters, which are fabricated on 2" to 4" wafer scales by nanosphere lithography. High-aspect-ratio junctions are made on a length scale similar to the thickness of optimized catalyst layers for water dissociation, creating a platform for probing the dual effects of catalysis and local electric field at the microscale BPM junction. Optimized polymer materials and nanoscale metal oxide catalysts are used in this study. 3D BPMs are tested under reverse and forward bias conditions, exhibiting superior performance relative to their 2D counterparts. Under forward bias in H 2- O 2 fuel cells, 3D BPMs achieve a current density of 1500 mA cm –2 , ≈7 times higher than 2D membranes made from the same materials.

25 ENERGY STORAGE↗

AI-Batt (Autonomous Identification of Battery Life Models) [SWR 21-36]

Autonomous Identification of Battery Life Models (AI-Batt) AI-Batt is a MATLAB code base for developing lifetime models for batteries from accelerated aging data. The code base provides many functions for processing, visualizing, and modeling battery aging data, making the data processing, exploration, and modeling workflow substantially faster. These tools are tailored for working with battery aging data sets, which usually consist of many separate time-series for each cell, with many test conditions and possible replicates at each condition, which makes it difficult to simply process or visualize the data set. Complex modeling tasks, such as cross-validation, sensitivity analysis, and uncertainty quantification have been implemented to enable thorough statistical investigation of model predictions. Additionally, several machine-learning algorithms are implemented to autonomously identify suitable models via symbolic regression. Data processing functions automatically cast data from the struct data type, which is commonly used to store experimental data, but is not an acceptable input for most algorithms, to the table data type, which can be easily used as input to any optimization algorithm. Also, the data can be separated into time-invariant and time-variant data tables, which is helpful for exploring the data set as well as developing separate models for time-variant and time-invariant aging mechanisms. For example, in aging tests with constant temperature, temperature is a time-invariant experimental condition. Visualization tools enable plotting of data, model fits, and model simulations possible with single-line function calls, empowering data exploration of complex data sets with both time-varying and time-invariant trends. Plots can be automatically generated for the whole data set, or separated by data group (groups of test replicates) or individual data series. Data points or data series can be automatically colored by the value of a variable with a variety of color maps, and model predictions can also be colored by the value of a fit statistic. Comparisons between data sets and the predictions/simulations of different models on the same data set can be easily plotted as well. Distributions of parameter values from bootstrap resampling can be plotted to visualize the reliability of parameter estimation, or determine any correlations between parameters. Modeling tools handle the complex task of creating and parsing symbolic equations for modeling battery lifetime. Equations are parsed to grab relevant data variables, parameter values, or specified sub-models for input into optimization, evaluation, or simulation functions. Models can be optimized locally (one set of parameters for each data series), bi-level (some parameters shared across the data set), or globally (single set of parameters for all data). Functions implementing symbolic regression algorithms help users to discover effective model equations, even in poorly sampled, high-dimensional data.

Smith, Kandler↗

Enabling Bipolar Membrane Manufacturing Using Microscopy

Bipolar membranes (BPMs) used for water treatment suffer from interface instabilities, causing premature failure and decreased performance. Recent research has highlighted the impacts of membrane morphology on mechanical behavior and performance. Improved material performance of thin film membranes requires enhanced transport properties coupled with better control of the mechanical characteristics to avoid premature failure of the film. Thus, morphology is a key parameter when developing and evaluating novel membrane materials. Microscopy offers unique advantages for nano-scale characterization of thin film membrane interfaces and morphologies. In this study, the interface junction of BPMs was evaluated using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDX). BPMs were fabricated using (1) hot pressing lamination, (2) bench-scale solution casting, and (3) roll-to-roll sequential casting (R2R). Both commercial and in-house fabricated ion exchange membranes were used in the BPMs. The BPMs were comprised of a cation exchange membrane and an anion exchange membrane with a catalyst layer sandwiched in between. Cross sectional SEM and EDX images of the membrane interface junction were compared among the different fabrication techniques and materials. The bench cast catalyst layers were nonuniform compared to the R2R and hot pressed membranes, demonstrating the importance of precise catalyst application conditions. Different thicknesses of the BPMs and individual membrane layers revealed that polymer solution concentration needs to be optimized during manufacturing. This work shows that microscopy can identify key processing parameters that affect BPM interface junction quality at the microscale to enable manufacturing of high performance BPMs.

36 MATERIALS SCIENCE↗

Enabling Roll-to-Roll Manufacturing of Bipolar Membranes Using Microscopy

Bipolar membranes (BPMs) used for water treatment suffer from interface instabilities, causing premature failure and decreased performance. Recent research has highlighted the impacts of membrane morphology on mechanical behavior and performance. Improved material performance of thin film membranes requires enhanced transport properties coupled with better control of the mechanical characteristics to avoid premature failure of the film. Thus, morphology is a key parameter when developing and evaluating novel membrane materials. Microscopy offers unique advantages for nano-scale characterization of thin film membrane interfaces and morphologies. In this study, the interface junction of BPMs was evaluated using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDX). BPMs were fabricated using (1) hot pressing lamination, (2) bench-scale solution casting, and (3) roll-to-roll sequential casting (R2R). Both commercial and in-house fabricated ion exchange membranes were used in the BPMs. The BPMs were comprised of a cation exchange membrane and an anion exchange membrane with a catalyst layer sandwiched in between. Cross sectional SEM and EDX images of the membrane interface junction were compared among the different fabrication techniques and materials. The bench cast catalyst layers were nonuniform compared to the R2R and hot pressed membranes, demonstrating the importance of precise catalyst application conditions. Different thicknesses of the BPMs and individual membrane layers revealed that polymer solution concentration needs to be optimized during manufacturing. This work shows that microscopy can identify key processing parameters that affect BPM interface junction quality at the microscale to enable manufacturing of high performance BPMs.

36 MATERIALS SCIENCE↗

Control of the positional relationship between a sample collection instrument and a surface to be analyzed during a sampling procedure with image analysis

A system and method utilizes an image analysis approach for controlling the collection instrument-to-surface distance in a sampling system for use, for example, with mass spectrometric detection. Such an approach involves the capturing of an image of the collection instrument or the shadow thereof cast across the surface and the utilization of line average brightness (LAB) techniques to determine the actual distance between the collection instrument and the surface. The actual distance is subsequently compared to a target distance for re-optimization, as necessary, of the collection instrument-to-surface during an automated surface sampling operation.

47 OTHER INSTRUMENTATION↗