Search NASA⌕ Search

SEARCH · Search NASA

Results for “Checking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Checking It Twice: Using [C/N] Masses and Asteroseismic Masses as a Diagnostic of Mass Loss and Transfer on the Red Giant Branch

Red giants experience significant mass loss, but the mechanism is poorly understood. The surface [C/N] of red giants is correlated with birth mass but not directly impacted by mass loss. Exploiting this, we compare asteroseismic masses of red giants with the same [C/N] but different evolutionary states. We find bulk differences between stars at the beginning of the red giant branch (RGB) and in the subsequent evolutionary phase, the red clump, providing a direct constraint on the strength of net RGB mass loss in field stars. We find that net mass loss decreases with metallicity and mass, matching recent studies for field giants but contradicting expectations from the widely used Reimers’s mass-loss formula. We propose a mass- and metallicity-dependent Reimers’s η calibration that reproduces the empirical trends that we see. In addition, we identify 200 stars (3.12% of our sample) that are clear outliers from their population in these birth mass bins, which we believe are likely candidates for mass transfer events. These stars do not show any obvious discrepancies in abundances or binary properties from their counterparts. This population should be accounted for in Galactic archeological studies. Further follow-up is required to quantify their occurrence rate and origin.

Roberts, John D. [The Ohio State Univ., Columbus, ↗

Thermocouples electrically checked while connected to data system

Constant current source is connected across the input of the millivolt measuring system to monitor the electrical continuity and resistance of multiple thermocouple installations without disconnecting them from a data system. This technique monitored gage thermocouple leads during the assembly and preflight testing of the Project Fire reentry packages.

Source record↗

Checking flat conductor cable spacing by means of a moire pattern

Moire tester detects small variations in flat conductor cable spacing by a quick, visual inspection. This device compares the cable to be tested with the negative of a very precise standard cable. The moire, consisting of bands of light and dark zones and its irregularities, can be interpreted as errors in spacing.

Angele, W.↗

Volume-checking tool

Tool, consisting of a graduated storage vessel and a control panel, can determine the amount of gas entrained by fluid in a closed system, the amount of fluid remaining in a dried system of known volume, or the volume of a container of unknown size.

Erbe, C. J.↗

Chatter-free check valve - A concept

Valve head moves in spiral motion away from seat. Motion is controlled by travel of pin along spiral groove in valve guide. Clearances between pin and groove permit free motion of valve, but effectively dampen vibration and chattering.

Dunbar, J. E.↗

Numerical check on the accuracy of spherical-wave expansions.

A simple and sensitive test for evaluating the numerical accuracy of a spherical-wave expansion is presented. The basic idea is to compare two different expansions of the same electromagnetic field, computed with respect to different coordinate origins. The use of the technique is illustrated by an example based on the experimental pattern of a horn antenna.

Ludwig, A. C.↗