Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cherenkov”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Cherenkov-Vavilov Formulation of X Waves

The field from a supersonic (or equivalently superluminal) point source in uniform motion [i.e., the Cherenkov-Vavilov (CV) effect] is shown to be equivalent to the diffractionless X-wave field. It is demonstrated that the power required to support an X wave is equivalent to the power dissipated by a CV source. In the context of the CV solution, it is clear that any supersonic or superluminal properties exhibited by X waves are purely phase effects. As a consequence, X waves cannot propagate a signal faster than the speed of waves, and thus necessarily obey the law on the finiteness of information transfer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A proposed measurement of the reverse Cherenkov radiation effect in a metamaterial-loaded circular waveguide

The authors have recently proposed an experiment on verification of the Reverse Cherenkov Radiation (RCR) effect in a Left-Handed-Material-loaded waveguide. Applications of the RCR effect may range from novel higher-order-mode suppressors in microwave and millimeter-wave sources to improved particle detectors for satellite non-proliferation missions. The experimental configuration includes a circular waveguide filled with an artificial metamaterial with simultaneously negative permittivity and permeability, in which the electromagnetic wave with a frequency of 95 GHz will interact with an electron beam. They have demonstrated that for certain values of effective permittivity and permeability only the backward-propagating mode can be exited by the electron beam. At the conference they will present some newly developed metamaterial designs, which they plan to employ for producing the proper effective medium parameters for this experiment.

36 MATERIALS SCIENCE↗

Time-Resolved Measurements of Cygnus X-ray Production Using Aerogel Cherenkov Detector

Aerogel Cherenkov Detector for Cygnus (ACD/C) has been developed to provide time-dependent x-ray spectral information from Cygnus – an intense flash x-ray source operated at the Nevada National Security Site. Time-resolved Cygnus x-ray signals were measured at three energy thresholds: 1.3 MeV (by 197 mg/cc aerogel), 1.1 MeV (by 260 mg/cc aerogel), and 0.3 MeV (by quartz). ACD/C data qualitatively suggest that the high-energy x-ray peak exists on a shorter timescale than the Cygnus voltage or current pulse. A time-dependent, x-ray spectral information can improve the understanding of the physics of dense objects radiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Plutonium Mass Uncertainty Assessment Using a Cherenkov-Based Neutron Multiplicity Water Detector

We present a new analysis of the sensitivity of a water Cherenkov-based neutron multiplicity counter for nondestructive assay of trace quantities of 240 Pu. The multiplicity counter [water-based neutron detector (WaND)] contains 1.0 m 3 of water doped with 0.2% gadolinium in the form of a gadolinium salt (0.4% GdCl 3 ). It can be used for testing the presence of trace quantities of 240 Pu within a sample of unknown material by observing the correlated timing behavior of neutron capture candidates in the detector. The new analysis takes advantage of the fact that the detector is comprised almost entirely of a homogeneous medium, which permits the use of a simple model to reproduce the observed neutron capture timing behavior. Finally, the results of this analysis indicate that the detector has an absolute neutron detection efficiency of 23.4 ± 1.1% and is sensitive to a 240 Pu mass as small as 2.3 mg (at 1σ) after a 1-h data acquisition.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Fielding the LANL Gas Cherenkov Detector (GCD-3) at the National Ignition Facility: The engineering challenges of designing, analyzing, fabricating, testing, and commissioning the next-generation GCD detector and WellDIM3.9m insertion manipulator for use at NIF

We report that fielding the LANL third-generation Gas Cherenkov Detector (GCD-3) at the National Ignition Facility (NIF) revealed an array of complex engineering challenges. Fielding the GCD-3 Detector in a 3.9 meter re-entrant Well on the NIF Target Chamber required the development of a specialized detector deployment system named the WellDIM3.9m Diagnostic Manipulator (WellDIM). The most stringent design requirement entailed a no-load/no-contact condition with the Well, which dictated that all seismic loads be transferred to the Target Chamber port flange. The WellDIM transports the GCD-3 into the Well at a distance of 3.9m from Target Chamber Center. Finally, the GCD-3 Detector, outfitted with additional shielding to mitigate higher NIF backgrounds, will serve as a prototype for the future, heavily shielded “Super-GCD”.

42 ENGINEERING↗

TH-C-17A-04: Shining Light On the Implementation of Cherenkov Emission in Radiation Therapy

Purpose: We hypothesize that Cherenkov emission (CE) by radiotherapy beams is correlated with radiation dose, CE detection can be maximized by a spectral shift towards the near-infrared (NIR) window of biological tissue, and in certain tissue types (ex. breast/oropharynx), it could prove superior to mega-voltage (MV) imaging. Therefore, we compare CE imaging to onboard MV imaging. Methods: Dose-CE correlation was investigated via simulation and experiment. A Monte Carlo (MC) CE simulator was designed using Geant4. Experimental phantoms include: water; tissuesimulating phantom composed of water, fat emulsion, and beef blood; plastic phantom with solid water insert. The optical spectrometry system consisted of a multi-mode optical fiber and diffraction-grating spectrometer incorporating a front/back-illuminated charge-coupled device (CCD). CdSe/ZnS quantum dots (QDs), emitting at (650±10) nm, were used to achieve NIR shift of the CE signal. CE and MV images were acquired with a complementary metal-oxide-semiconductor (CMOS) camera and an electronic portal imaging device (EPID), respectively. Results: MC and experimental studies indicate a strong linear correlation between radiation dose and CE (Pearson coefficient > 0.99). CE by an 18 MeV beam was effectively shifted towards the NIR in water and in a tissue-simulating phantom, exhibiting a 50% increase at 650 nm for QD depths of ∼3 mm. CE images exhibited relative contrast superior to EPID images by a factor of 30. Conclusion: Our work supports the potential for application of CE in radiotherapy online imaging for patient setup and treatment verification, since CE is intrinsic to the beam and non-ionizing, and QDs can be used to improve CE detectability, yielding image quality superior to MV imaging for the case of low density variability, low optical attenuation materials, such as breast or oropharyngeal cavities. Ongoing work involves microenvironment functionalization of QDs and application of multichannel spectrometry for simultaneous acquisition of dosimetric and tumor oxygenation signals. Funding received from the following organizations: Natural Sciences and Engineering Research Council of Canada, McGill University. YZ acknowledges partial support by the CREATE Medical Physics Research Training Network grant of the Natural Sciences and Engineering Research Council (Grant number: 432290)

07 ISOTOPE AND RADIATION SOURCES↗

Poster — Thur Eve — 18: Cherenkov Emission By High-Energy Radiation Therapy Beams: A Characterization Study

We investigate Cherenkov emission (CE) by radiotherapy beams via radiation dose-versus-CE correlation analyses, CE detection optimization by means of a spectral shift towards the near-infrared (NIR) window of biological tissue, and comparison of CE to on-board MV imaging. Dose-CE correlation was investigated via simulation and experiment. A Monte Carlo (MC) CE simulator was designed using Geant4. Experimental phantoms include: water; tissue-simulating phantom composed of water, Intralipid®, and beef blood; plastic phantom with solid water insert. The detector system comprises an optical fiber and diffraction-grating spectrometer incorporating a front/back-illuminated CCD. The NIR shift was carried out with CdSe/ZnS quantum dots (QDs), emitting at (650±10) nm. CE and MV images were acquired with a CMOS camera and electronic portal imaging device. MC and experimental studies indicate a strong linear dose-CE correlation (Pearson coefficient > 0.99). CE by an 18-MeV beam was effectively NIR-shifted in water and a tissue-simulating phantom, exhibiting a significant increase at 650 nm for QD depths up to 10 mm. CE images exhibited relative contrast superior to MV images by a factor of 30. Our work supports the potential for application of CE in radiotherapy online imaging for patient setup and treatment verification, since CE is intrinsic to the beam and non-ionizing and QDs can be used to improve CE detectability, potentially yielding image quality superior to MV imaging for the case of low-density-variability, low-optical-attenuation materials (ex: breast/oropharynx). Ongoing work involves microenvironment functionalization of QDs and application of multi-channel spectrometry for simultaneous acquisition of dosimetric and tumor oxygenation signals.

07 ISOTOPE AND RADIATION SOURCES↗

Cherenkov radiation of a Josephson vortex moving in a sandwich embedded in a dielectric medium

A motion of a Josephson vortex in a long sandwich embedded in a dielectric medium is described. If the velocity of the vortex is greater than the velocity of light in the dielectric, terahertz-band Cherenkov radiation is generated and emitted from the lateral surface of the sandwich. The radiation loss power is determined. In the case when radiation loss is compensated for by the energy gain due to transport current, a relation between the current and the velocity of the vortex is obtained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Vavilov–Cherenkov radiation when cosmic rays pass through the relic photon gas and when fast charged particles traverse an optical laser beam

Using a new [9, 10] quantum theory of Vavilov–Cherenkov radiation (VCR) based on Abraham’s theory, we show that a threshold VCR effect can be excited by the relic photon gas when relativistic charged cosmic-ray particles with γ ≥ γ{sub th} ≈ 1.9 × 10{sup 10} (where γ{sup –2} = 1–v{sup 2}/c{sup 2}, v is the particle speed, and c is the speed of light in a vacuum) pass through it. This is compatible with the well-known GZK cutoff [7, 8] at γ ≈ 10{sup 11}. We have obtained the condition γ > γ{sub th} ≈ 2.1 × 10{sup 2} for the appearance of VCR when a sufficiently fast charged particle (an electron, a proton, or a nucleus) passes through intense laser radiation. This condition ensures that VCR can be observed experimentally (e.g., on the Large Hadron Collider) without invoking any additional conditions required from the currently existing estimate of γth > 8.8 × 10{sup 4} [13] based on the now universally accepted quantum theory of VCR, which follows from Minkowski’s theory (and which gives an estimate of γ > 10{sup 21} when excited by the relic photon gas).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Employing Cherenkov radiation and fluorescence light in calibrating the energy of giant air showers

A classic procedure for estimating the energy of giant air showers in terms of the parameter s(600) (density of energy deposition in a scintillator at a distance of 600 m from the shower axis) is analyzed on the basis of the model of quark-gluon strings. A simulation of the signal s(600) by means of the CORSIKA code leads to estimates of energy that are approximately 1.6 times lower than those adopted at the Yakutsk array. Estimates of energy on the basis of Cherenkov radiation agree with experimental data within the errors. Calculations of the distributions of energy deposited in the atmosphere indicate that more than 20% of this energy can be deposited at distances in excess of 100 m from the shower axis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Restoration of parameters of high-energy cascades in Cherenkov water calorimeter with a dense array of quasispherical modules

A problem concerning the restoration of the parameters of a cascade shower with an unknown axis originating by muons in a Cherenkov water calorimeter is considered. A method for estimating the direction and geometric position of the cascade’s axis, which is based on the analysis of responses of quasispherical modules, and the criteria of selection of the events with cascades among the events with a large energy liberation are proposed. The method and the criteria are tested on events with cascades generated by near-horizontal muons of high energies detected by a DECOR coordinate-track detector. The preliminary results of measurements of the energy spectrum of cascade showers are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum theory of stimulated Cherenkov emission and stimulated compton scattering of electromagnetic waves by a low-density relativistic electron beam

A quantum theory of instabilities of a relativistic electron beam due to the stimulated Cherenkov effect in a dielectric and the stimulated Compton effect in vacuum is presented. The instability growth rates are found in a linear approximation and are shown to go over to the familiar growth rates in the classical approximation. A nonlinear theory of instabilities in the quantum case is developed. Analytic solutions are obtained that describe the nonlinear saturation of the amplitudes of the electromagnetic waves emitted by the beam.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cherenkov Radiation Generated by an Electron Bunch in a Rectangular Dielectric Waveguide Filled with a Transversely Isotropic Medium

Dielectric waveguides are being intensively studied as accelerating structures excited by an electron bunch. Rectangular dielectric structures are used both to test the principles of new accelerating schemes and to study the electric properties of filling materials. Several dielectric materials used as fillers of waveguides have anisotropic properties (sapphire, ceramic films). Anisotropy can have a significant effect on the wakefields generated by an electron bunch in a structure. The paper presents an analytical calculation of Vavilov–Cherenkov radiation generated by a relativistic electron bunch in a rectangular waveguide filled with a transversely inhomogeneous transversely isotropic dielectric. A method for constructing an orthogonal basis of the transverse operator with its subsequent use to find the wakefield is presented. A dispersion relation for the structure and expressions for the wakefield created by a point electron bunch in a transversely isotropic rectangular dielectric structure are obtained. Based on the formalism presented, parameters of an accelerating structure based on sapphire, allowing the generation of fields above 100 MV/m, are calculated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Diagnosing Thermonuclear Burn in Fusion Implosions using Ultra-Fast Gas Cherenkov Detectors [Slides]

This presentations addresses these questions. What is fusion and what is ignition? How does LASER driven Inertial Confinement Fusion work? What can we measure and what does it tell us about fusion? How do Gas Cherenkov detectors work and what do they tell us? What are our plans for the future? In brief, the take away messages for this presentation are as follows: DT fusion reaction history provides crucial physics for ICF; gamma reaction history diagnostics are ready to resolve burn width on ignition shots; and GCDs have a lot of potential solving some of the questions related to fusion science.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

UPPER LIMITS FROM FIVE YEARS OF BLAZAR OBSERVATIONS WITH THE VERITAS CHERENKOV TELESCOPES

Between the beginning of its full-scale scientific operations in 2007 and 2012, the VERITAS Cherenkov telescope array observed more than 130 blazars; of these, 26 were detected as very-high-energy (VHE; E > 100 GeV) γ -ray sources. In this work, we present the analysis results of a sample of 114 undetected objects. The observations constitute a total live-time of ∼570 hr. The sample includes several unidentified Fermi -Large Area Telescope (LAT) sources (located at high Galactic latitude) as well as all the sources from the second Fermi -LAT catalog that are contained within the field of view of the VERITAS observations. We have also performed optical spectroscopy measurements in order to estimate the redshift of some of these blazars that do not have spectroscopic distance estimates. We present new optical spectra from the Kast instrument on the Shane telescope at the Lick observatory for 18 blazars included in this work, which allowed for the successful measurement or constraint on the redshift of four of them. For each of the blazars included in our sample, we provide the flux upper limit in the VERITAS energy band. We also study the properties of the significance distributions and we present the result of a stacked analysis of the data set, which shows a 4 σ excess.

79 ASTRONOMY AND ASTROPHYSICS↗