Search NASA⌕ Search

SEARCH · Search NASA

Results for “Collective levels”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

The Operational MODIS Cloud Optical and Microphysical Property Product: Overview of the Collection 6 Algorithm and Preliminary Results

Operational Moderate Resolution Imaging Spectroradiometer (MODIS) retrievals of cloud optical and microphysical properties (part of the archived products MOD06 and MYD06, for MODIS Terra and Aqua, respectively) are currently being reprocessed along with other MODIS Atmosphere Team products. The latest "Collection 6" processing stream, which is expected to begin production by summer 2012, includes updates to the previous cloud retrieval algorithm along with new capabilities. The 1 km retrievals, based on well-known solar reflectance techniques, include cloud optical thickness, effective particle radius, and water path, as well as thermodynamic phase derived from a combination of solar and infrared tests. Being both global and of high spatial resolution requires an algorithm that is computationally efficient and can perform over all surface types. Collection 6 additions and enhancements include: (i) absolute effective particle radius retrievals derived separately from the 1.6 and 3.7 !-lm bands (instead of differences relative to the standard 2.1 !-lm retrieval), (ii) comprehensive look-up tables for cloud reflectance and emissivity (no asymptotic theory) with a wind-speed interpolated Cox-Munk BRDF for ocean surfaces, (iii) retrievals for both liquid water and ice phases for each pixel, and a subsequent determination of the phase based, in part, on effective radius retrieval outcomes for the two phases, (iv) new ice cloud radiative models using roughened particles with a specified habit, (v) updated spatially-complete global spectral surface albedo maps derived from MODIS Collection 5, (vi) enhanced pixel-level uncertainty calculations incorporating additional radiative error sources including the MODIS L1 B uncertainty index for assessing band and scene-dependent radiometric uncertainties, (v) and use of a new 1 km cloud top pressure/temperature algorithm (also part of MOD06) for atmospheric corrections and low cloud non-unity emissivity temperature adjustments.

Platnick, Steven↗

Preliminary Sensorimotor and Cardiovascular Results from the Joint Russian and U.S. Pilot Field Test with Planning for the Full Field Test Beginning with the Year Long Intenational Space Station

Ongoing collaborative research efforts between NASA's Neuroscience and Cardiovascular Laboratories, and the Institute of Biomedical Problems' (IBMP) Sensory-Motor and Countermeasures Laboratories have been measuring functional sensorimotor, cardiovascular and strength responses following bed rest, dry immersion, short duration (Space Shuttle) and long duration (Mir and International Space Station) space flights. While the unloading paradigms associated with dry immersion and bed rest does serve as acceptable flight analogs, testing of crew responses following the long duration flights previously has not been possible until a minimum of 24 hours after landing. As a result, it is not possible to estimate the nonlinear trend of the early (<24 hr) recovery process, nor is it possible to accurately assess the full impact of the decrements associated with long duration flight. To overcome these limitations, both the Russian and U.S. sides have implemented testing at landing site. By joint agreement, this research effort has been identified as the functional Field Test (FT). For practical reasons the FT has been divided into two phases: the full FT and a preliminary pilot version (PFT) of the FT that is reduced in both length and scope. The primary goal of this research is to determine functional abilities in long duration space flight crews beginning as soon after landing as possible (< 2 hr) with one to three immediate follow-up measurements on the day of landing. This goal has both sensorimotor and cardiovascular elements, including evaluations of NASA's new anti-orthostatic compression garment and the Russian Kentavr garment. Functional sensorimotor measurements will include, but are not limited to, assessment of hand/eye coordination, ability to egress from a seated position, walk normally without falling, measurement of dynamic visual acuity, ability to discriminate different forces generated with both the hands and legs, recovery from a fall, a coordinated walk involving tandem heel-to-toe placement, and determination of postural ataxia while standing. The cardiovascular portion of the investigation includes blood pressure and heart rate measurements during a timed stand test in conjunction with postural ataxia testing (quiet stance sway) as well as cardiovascular responses during other functional tasks. In addition to the immediate post-landing collection of data for the full FT, postflight data will be acquired at a minimum of one to three more other times within the 24 hr following landing and continue until functional sensorimotor and cardiovascular responses have returned to preflight normative values. The PFT represents a single trial run comprised of jointly agreed upon subset of tests from the full FT and relies heavily on IBMP's Sensory-Motor and Countermeasures Laboratories for content and implementation. The PFT was first conducted following the September 2013 landing of the Soyuz spacecraft (34S) and again following the landing of Soyuz 35S in November. Testing included: (1) a sit-tostand test, (2) recovery from a fall where the crewmember began in the prone position on the ground and then stood for 3 min while cardiovascular stability was determined and postural ataxia data were acquired, and (3) a tandem heel-to-toe walk test to determine changes in the central locomotor program. Video, cardiovascular parameters (heart rate and blood pressure), data from body-worn inertial sensors and severity of postflight motion sickness were collected for analysis. In summary, the level of functional deficit is expected to be most profound during the acquisition of gravity loads immediately after landing when the demands for crew intervention in response to emergency operations will be greatest. Clearly measureable performance parameters such as ability to perform a seat egress, recover from a fall or the ability to see clearly when walking, and related physiological data (orthostatic responses) are required to provide an evidence base for characterizing programmatic risks and the degree of variability among crewmembers for exploration missions where the crew will be unassisted after landing. Overall, these early functional and related physiological measurements will allow estimation of nonlinear sensorimotor and cardiovascular recovery trends to an accuracy that has not been previously captured in over 50 years of space flight.

Reschke, M. F.↗

Perfluorinated Alkyl Acids and Fecundity Assessment in Striped Mullet (Mugil Cephalus) at Merritt Island National Wildlife Refuge

This study investigated wild caught Striped mullet (Mugil cephalus) at Merritt Island National Wildlife Refuge (MINWR) for levels of 15 perfluoroalkyl acids (PFAAs) in tandem with fecundity measurements (n 42) and oocyte developmental stages (n 128). PFAAs measurements were undertaken for liver (n 128), muscle (n 49), and gonad (n 10). No significant negative impacts of liver PFAA burden on wild-caught, mullet fecundity endpoints are observed in this study; however, changes in PFAAs are seen in the liver as mullet progress through different sub-stages of oocyte development. Of the PFAAs with significant changes by sub-stage of oocyte development, the carboxylic acids (perfluorooctanoic acid, perfluorononanoic acid, and perfluorotridecanoic acid) increase in the liver with increasing sub-stage while the sulfonic acid and its precursor (perfluorooctanesulfonic acid (PFOS) and perfluorooctanesulfonamide, respectively) decrease in the liver with increasing stage of oocyte development. This is a unique find and suggests PFAAs change location of compartmentalization as mullet progress towards spawning. Investigations also revealed higher than expected median muscle and gonad levels of PFOS in Striped mullet collected at MINWR (9.01 ngg and 80.2 ngg, respectively).

Jacqueline T Bangma↗

MODIS Reflective Solar Band Calibration Improvements using Pseudo-Invariant Desert Targets

To provide the best science data quality, an accurate characterization of the response versus scan angle (RVS) function is critical for the MODIS reflective solar bands (RSB) on-orbit calibration. In every MODIS operational scan, the Earth’s surface, referred to here as Earth view (EV), the space view (SV) port, and the onboard calibrators are viewed via a two-sided scan mirror. The RVS is defined as the sensor’s relative response as a function the angle of incidence (AOI) to the scan mirror. Many different approaches have been developed to derive the time-dependent RVS and its look-up table (LUT) applied to MODIS Level 1B (L1B) products since calibration Collection 4. For most MODIS RSB, the on-board calibrators can reasonably track the RVS change with time. In practice, their RVS is derived using data from on-board calibrators and the EV mirror side ratio (for mirror side 2). For Terra bands 1-4, 8-10 and Aqua bands 1-4, 8-9, an enhancement has been employed in Collections 6 and 6.1 (C6/C6.1) by using Earth scene response trending from pseudo-invariant desert sites in addition to the onboard calibrators. The current C6/C6/1 RVS algorithm is focused on fitting the EV data at each AOI over time and then deriving the relative change at different AOI. The EV response trending is currently fitted with multiple segments over time. Alternatively, the EV responses can be fit first as a function of AOI before fitting temporally in order to reduce the dependence on the stability of the desert site. These pre-treatment methods on the EV data provide improvement in the derived calibration coefficients. However, evidence of insufficient calibration is still observed in the MODIS L1B reflectance data, especially in the form of differences between the mirror sides. In this paper, we review the current methodologies that utilize the EV response trends from the pseudo-invariant Libyan desert targets to supplement the gain derived from the onboard calibrators. An improvement is then proposed and investigated such that a sliding window average (SWA) is used to pre-process the raw EV data. The SWA parameters are carefully selected using trade-off studies to accurately track the Earth scene response trending in multiple cases to overcome the reflectance differences between two mirror sides. Calibration results show improvements for both Aqua and Terra MODIS RSB L1B data products. This new adjustment has been included in the recently delivered Collection 7 LUT that will be evident in the L1B products expected to be released in late 2021.

MODIS↗

Observation Impact and Information Retention in the Lower Troposphere of the GMAO GEOS Data Assimilation System

In this study, we have assessed the effectiveness of the use of existing observing systems in the lower troposphere in the GEOS hybrid–4DEnVar data assimilation system through a set of observing system experiments. The results show that microwave radiances have a large impact in the Southern Hemisphere and Tropical ocean, but the large influence is mostly observed above 925 hPa and dissipates relatively quickly with longer forecast lead times. Conventional data information holds better in the forecast ranging from the surface to 100 hPa, depending on the field evaluated, in the Northern Hemisphere and lowest model levels in the Tropics. Infrared radiances collectively have much less impact in the lower troposphere. Removing surface observations has small but persistent impact on specific humidity in the upper atmosphere, but small or negligible impact on planetary boundary layer (PBL) height and temperature. The model responses to the incremental analysis update (IAU) forcing are also analyzed. In the IAU assimilation window, the physics responds strongly to the IAU forcing in the lower troposphere, and the changes of physics tendency in the lower troposphere and hydrodynamics tendency in the mid- and upper troposphere are viewed as beneficial to the reduction of state error covariance. In the subsequent forecast, the model tendencies continue to deviate further from the original free forecast with forecast lead times around 300–400 hPa, but physics tendency has showed signs of returning to its original free forecast mechanisms at 1-day forecast in the lower troposphere.

GEOS↗

Preparation for an Earth Independent Medical Operations Demonstration using the Tempus ALS™ Medical Device

NASA’s exploration-class missions have severe resource constraints, long return trip durations, significant communication delays and limited resupply opportunities. Validation on the International Space Station (ISS) of medical devices that fit within Earth-Independent Medical Operations (EIMO) systems is a necessary preparation step. Key features of an EIMO medical system include: 1) technologies that support the prevention, diagnosis, and treatment of spaceflight medical events; 2) components that meet mass, volume, power and crew time/training constraints; 3) consideration of the medical skill level of the astronaut caregiver; 4) collection, storage and analysis of medical data within a central data architecture; and 5) incorporation of appropriate guidance and support tools that allow crew autonomy. The Human Research Program’s (HRP) Exploration Medical Capability (ExMC) Element and the Exploration Medical Integrated Product Team (XM-IPT) are planning an ISS technology demonstration to determine the feasibility of including a multifunctional medical device into an EIMO medical system. Demonstration Preparations: The Tempus ALS (Remote Diagnostic Technologies, Ltd., Philips Corp., Farnborough, UK) is a commercial-off-the-shelf medical device, with United States Food and Drug Administration clearance and is Conformité Européene marked in Europe. Several thousand units have been sold and are successfully operating in pre-hospital and in remote settings, such as by European Space Agency (ESA) flight surgeons and some of NASA’s commercial partners during post-flight medical operations. The Tempus ALS provides vital sign measurements such as blood pressure, electrocardiograms, heart rate, end tidal CO2, respiration rate, pulse oximetry and temperature. The device has ultrasound imaging and video laryngoscopy capabilities and has automatic or manual defibrillation modes for treating cardiac arrhythmias. It includes procedural guidance capabilities to assist in the collection of the vital sign measurements and it has various data transmission and report generation features. NASA’s HRP ExMC and XM-IPT are partnering with the ESA to demonstrate the Tempus ALS on ISS, with ESA manifesting the Tempus ALS and its accessories. ESA will compare performance of periodic health status exams and medical contingency drills performed nominally and with the Tempus ALS. NASA’s EIMO demonstration will include the use of Tempus ALS to diagnose a complaint of abdominal pain under increasingly independent circumstances. The caregiver must assess the present illness, collect vital sign measurements, and perform an abdominal ultrasound, under one of three communication situations, including real-time, with a several second delay and with a delay on the order of minutes. Expected Outcomes: Information will be gained about the feasibility, benefits, and challenges of using a multifunctional, all-in-one, medical device for medical diagnosis instead of separate devices with singular functionalities. Information will also be collected about performance differences as communication delays increase and available ground support decreases. Gaining this understanding will allow for further development of exploration medical system capabilities which takes the EIMO construct into consideration.

Beth Lewandowski↗

A Multi-Faceted Approach to Demonstrating Multi-Functional Integrated Medical Devices to Advance Earth-Independent Medical Operations

INTRODUCTION TO MIM DEVICES Multi-functional Integrated Medical (MIM) devices conveniently incorporate multiple medical system capabilities within one device. The NASA Exploration Medical Integrated Product Team (XM-IPT) sponsored a market survey and trade study which identified the Tempus ProTM and the LifeBot 10® as the MIM devices that best met the evaluation criteria of the trade study. The Tempus ProTM (Remote Diagnostic Technologies, Ltd., Philips Corp., Farnborough, UK) and LifeBot 10® (LifeBot Health, Chicago, IL) both provide vital sign measurements such as blood pressure, electrocardiograms, heart rate, end tidal CO2, respiration rate, pulse oximetry and temperature along with ultrasound imaging. A video laryngoscopy capability is unique to the Tempus ProTM, while the LifeBot 10® supports connectivity with a digital stethoscope, otoscope, eye exam camera, and dermatoscope. Both devices include procedural guidance capabilities and have various data transmission and report generation features. TECHNOLOGY DEMONSTRATIONS NASA’s exploration-class missions will have severe resource constraints, long return trip durations, significant communication delays, and limited resupply opportunities. The medical systems of these missions will need to fit within an Earth-Independent Medical Operations (EIMO) construct. Key features of an EIMO medical system include: 1) technologies that support the prevention, diagnosis, and treatment of spaceflight medical events; 2) components that meet mass, volume, power and crew time/training constraints; 3) consideration of the medical skill level of the astronaut caregiver; 4) collection, storage and analysis of medical data within a central data architecture; and 5) incorporation of appropriate guidance and support tools that allow crew autonomy. Evaluations are underway to determine if it will be beneficial to include MIM devices within exploration medical systems by conducting a series of planned technical demonstrations. Exploration Atmosphere Chamber studies are being performed to determine MIM functionality in a high oxygen concentration atmosphere. A side-by-side comparison of the Tempus ProTM and LifeBot 10® will be performed during ground-based demonstrations. Use of the MIM devices within an EIMO medical scenario simulation will be practiced during ground-based demonstrations in preparation for International Space Station (ISS) demonstrations of the MIM device. These various demonstrations are designed to gather evidence for or against the inclusion of MIM devices within an EIMO medical system. EXPECTED DEMONSTRATION OUTCOMES Information will be gained about the feasibility, benefits, and challenges of using a multifunctional, all-in-one, medical device for medical diagnosis. Information will also be collected about performance differences as available ground support decreases. Gaining this understanding will allow for further development of exploration medical system capabilities, which take the EIMO construct into consideration.

B. E. Lewandowski↗

BOREAS AFM-2 King Air 1994 Aircraft Flux and Moving Window Data

The BOREAS AFM-2 team collected pass-by-pass fluxes (and many other statistics) for a large number of level (constant altitude), straight-line passes used in a variety of flight patterns. The data were collected by the University of Wyoming King Air in 1994 BOREAS IFCs 1-3. Most of these data were collected at 60-70 m above ground level, but a significant number of passes were also flown at various levels in the planetary boundary layer, up to about the inversion height. This documentation concerns only the data from the straight and level passes that are presented as original (over the NSA and SSA) and moving window values (over the Transect). Another archive of King Air data is also available, containing data from all the soundings flown by the King Air 1994 IFCs 1-3. The data are stored in tabular ASCII files. The data files are available on a CD-ROM (see document number 20010000884) or from the Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC).

Kelly, Robert D.↗

Cardiovascular Responses to Simulated Spaceflight: Molecular Signatures and Surrogate Outputs to Measure CVD Risk

During extended space missions beyond low Earth orbit, astronauts will encounter prolonged periods of weightlessness and low dose space radiation. Previous studies have shown that exposure to small doses of high LET radiation (< 50 cGy) can lead to both short-term and long-term alterations in heart function, structure and underlying molecular mechanisms. In this study, we aim to identify the molecular signature associated with the cardiovascular response to simulated galactic cosmic radiation (5-ion GCR) alone or in combination with simulated weightlessness at time intervals relevant to mission length and recovery. Additionally, we aim to determine whether sex impacts cardiovascular responses to these spaceflight factors. Our overarching goal is to enhance our understanding of the cardiovascular risks associated with extended space missions and the clinical endpoints they suggest. We hypothesize that exposure to simulated space radiation leads to enduring alterations in the transcriptome, redox signaling and cytokine environment of cardiovascular tissue, some which have known links with reduced cardiovascular performance, aging, and increased risk of cardiovascular disease (CVD). Furthermore, we posit that simulated space radiation exposure in combination with simulated microgravity exacerbates cardiovascular deficits compared to single factor exposure. Female and male C57BL/6J mice, aged 23-24 weeks, were exposed to a single dose of 5, 15, or 50 cGy of 5-ion GCR, or sham-treated (0 cGy). Euthanasia was performed at 14 days and ~4 months post-irradiation. Hearts, aorta and blood plasma were collected shortly thereafter. RNA-sequencing of left ventricles at ~4 months post-GCR exposure revealed sex differences in the heart transcriptome with a few genes showing radiation-dependent changes in expression levels. Notably, some of the differentially expressed genes in 15 and 50 cGy GCR groups are known to play roles in the development of CVD. Analysis of protein levels of a subset of inflammatory cytokines in the heart indicated sex differences but no differences between sham and 50 cGy groups. Results also showed correlations among differentially expressed genes and a subset of inflammatory cytokines, with some correlations altered by GCR exposure. These findings suggest that GCR exposure can modify protein and gene networks linked to inflammation and CVD progression. In the aorta, telomere lengths were comparable across treatment groups sexes. Mitochondrial copy number is a biomarker for mitochondrial function with decreased copy numbers associated with cardiometabolic disease traits. Mitochondrial copy numbers of aorta also showed no sex nor dose differences. In a second study, mice underwent one week of simulated microgravity by hindlimb unloading (HU) and then exposed to a single dose of 15 cGy of 5-ion GCR. HU was conducted for an additional two weeks following GCR exposure. Single factor exposure groups (HU or GCR only) also were included in the study. Euthanasia was then performed and the same tissues were collected. Protein levels of select inflammatory cytokines in the heart showed sex-dependent differences in expression. In the aorta, telomere lengths and mitochondrial copy number also showed sex differences. In summary, our results indicate differences between sexes in biomarkers related to cardiovascular health. Exposure to 5-ion GCR or HU, alone or in combination, did not result in changes in most of the cardiovascular biomarkers that were examined. However, in the heart, simulated space radiation at doses of 15 and 50 cGy led to long-term alterations in the expression levels of a small group of genes known to be associated with the progression of CVD. The long-term transcriptomic changes resulting from exposure to simulated space radiation should be carefully investigated to mitigate adverse cardiovascular events during and after deep space missions. Our results also highlight the importance of sex-specific strategies in monitoring and maintaining cardiovascular health during and after deep space missions.

cardiovascular↗

Monitoring of streamflow in the Verde River by ERTS-1 Data Collection System (DCS)

The Verde River watershed in central Arizona furnishes municipal, industrial, and agricultural water to the Salt River Valley --an area that contains more than half of Arizona's population and about one-fourth of the State's irrigated land. Water-management decisions related to the operation of large multiple-use reservoirs require accurate and continuous monitoring of moisture conditions over large remote areas. The U.S. Geological Survey in cooperation with the Salt River Valley Water Users' Association installed a specially designed gaging station on the Verde River near the town of Camp Verde to evaluate near-real time streamflow data furnished by the ERTS-1 Data Collection System (DCS). On Nov. 3, 1972, the installation was equipped with a Stevens digital water-level recorder, modified for telemetry, and an ERTS-1 data collection platform operating in the digital-parallel mode.

Schumann, H. H.↗

Nonlinear effects in thermal stress analysis of a solid propellant rocket motor

Direct characterization procedures were used to determine the relaxation modulus as a function of time, temperature, and state of strain. Using the quasi-elastic method of linearviscoelasticity, these properties were employed in a finite element computer code to analyze a thick-walled, nonlinear viscoelastic cylinder in the state of plane strain bonded to a thin (but stiff) elastic casing and subjected to slow thermal cooling. The viscoelastic solution is then expressed as a sequence of elastic finite element solutions. The strain-dependent character of the relaxation modulus is included by replacing the single relaxation curve used in the linear viscoelastic theory by a family of relaxation functions obtained at various strain levels. These functions may be regarded as a collection of stress histories or responses to specific loads (in this case, step strains) with which the cooldown solution is made to agree by iterations on the modulus and strain level.

Francis, E. C.↗

Sensitivity of wheat and rice to low levels of atmospheric ethylene

Ethylene (C2H4) gas is produced throughout the life cycle of plants and can accumulate in closed growth chambers to levels 100 times higher than in outside environments. Elevated atmospheric C2H4 can cause a variety of abnormal responses, but the sensitivity to elevated C2H4 is not well characterized. We evaluated the C2H4 sensitivity of wheat (Triticum aestivum L.) and rice (Oryza sativa L.) in five studies. The first three studies compared the effects of continuous C2H4 levels ranging from 0 to 1000 nmol mol-1 (ppb) in a growth chamber throughout the life cycle of the plants. A short-term 1000 nmol mol-1 treatment was included in which exposure was stopped at anthesis. Yield was reduced by 36% in wheat and 63% in rice at 50 nmol mol-1 and both species were virtually sterile when continuously exposed to 1000 nmol mol-1. However, the yield reductions were much less with exposure that stopped at anthesis, suggesting the detrimental effect of C2H4 on yield was greatest around the time of seed set. Two additional studies evaluated the differential sensitivity of two wheat cultivars (Super Dwarf and USU-Apogee) to 50 nmol mol-1 C2H4 at three CO2 levels [350, 1200, 5000 micromoles mol-1 (ppm)] in a greenhouse. Yield of USU-Apogee was not significantly reduced by C2H4 but the yield of Super Dwarf was reduced by 60%. Elevated CO2 did not influence the sensitivity to C2H4. A difference in the C2H4 sensitivity of USU-Apogee between greenhouse and growth chamber trials suggests that C2H4 sensitivity is dependent on the environment. Collectively, the data suggest that relatively low levels of C2H4 could induce anomalous plant responses by accumulation in greenhouses and growth chambers with inadequate ventilation. The data also suggest that C2H4 sensitivity can be reduced by both genetic and environmental manipulations. 2002 Crop Science Society of America.

NASA Discipline Life Sciences Technologies↗

Field Test: Results of Tandem Walk Performance Following Long-Duration Spaceflight

BACKGROUND: Coordinated locomotion has proven to be challenging for many astronauts following long duration spaceflight. As NASA's vision for spaceflight points toward interplanetary travel, we must prepare for unassisted landings, where crewmembers may need to perform mission critical tasks within minutes of landing. Thus, it is vital to develop a knowledge base from which operational guidelines can be written that define when astronauts can be expected to safely perform certain tasks. Data obtained during the Field Test experiment (FT) will add important insight to this knowledge base. Specifically, we aim to develop a recovery timeline of functional sensorimotor performance during the first 24 hours and several days after landing. METHODS: FT is an ongoing study of 30 long-duration ISS crewmembers. Thus far, 9 have completed the full FT (5 U.S. Orbital Segment [USOS] astronauts and 4 Russian cosmonauts) and 4 more consented and launching within the next year. This is in addition to the eighteen crewmembers that participated in the pilot FT (11 USOS and 7 Russian crewmembers). The FT is conducted three times preflight and three times during the first 24 hours after landing. All crewmembers were tested in Kazakhstan in either the medical tent at the Soyuz landing site (~one hour post-landing), or at the airport (~four hours post-landing). The USOS crewmembers were also tested at the refueling stop (~12 hours post-landing) and at the NASA Johnson Space Center (~24 hours post-landing) and a final session 7 days post-landing. Crewmembers are instrumented with 9 inertial measurement unit sensors that measure acceleration and angular displacement (APDM's Emerald Sensors) and foot pressure-sensing insoles that measure force, acceleration, and center of pressure (Moticon GmbH, Munich, Germany) along with heart rate and blood pressure recording instrumentation. The FT consists of 12 tasks, but here we will focus on the most challenging task, the Tandem Walk, which was also performed as part of pilot FT. To perform the Tandem Walk, subjects begin with their feet together, their arms crossed at their chest and eyes closed. When ready, they brought one foot forward and touched the heel of their foot to their toe, repeating with the other foot, and continuing for about 10 steps. Three trials were collected with the eyes closed and a fourth trial was collected with eyes open. There are four metrics which are used to determine the performance level of the Tandem Walk. The first is percent correct steps. For a step to be counted as correct, the foot could not touch the ground while bringing it forward (no side stepping), eyes must stay closed during the eyes closed trials, the heel and toe should be touching, or almost touching (no large gaps) and there shouldn't be more than a three second pause between steps. Three judges score each step and the median of the three scores is kept. The second metric is the average step speed, or the number of steps/time to complete them. Thirdly, the root mean squared (RMS) error in the resultant trunk acceleration is used to determine the amount of upper body instability observed during the task. Finally, the RMS error of the mediolateral center of pressure as measured by the Moticon insoles is used to determine the mediolateral instability at the foot level. These four parameters are combined into a new overall Tandem Walk Parameter. RESULTS: Preliminary results show that crewmembers perform the Tandem Walk significantly worse the first 24 hours after landing as compared to their baseline performance. We find that each of the four performance metrics is significantly worse immediately after landing. We will present the results of tandem walk performance during the FT thus far. We will also combine these with the 18 crewmembers that participated in the pilot FT, concentrating on the level of performance and recovery rate. CONCLUSION: The Tandem Walk data collected as part of the FT experiment will provide invaluable information on the performance capabilities of astronauts during the first 24 hours after returning from long-duration spaceflight that can be used in planning future Mars, or other deep-space missions with unassisted landings. FT will determine the average sensorimotor recovery timeline and inform return-to-duty guidelines for unassisted landings.

Rosenberg, M. J. F.↗

Quantitation of Trace Water in ISS Atmosphere Samples Recovered from CO2-Removal Systems

As crewed spaceflight continues to push the limits of exploration, instruments and hardware used to maintain and monitor crew and vehicle health, must become more integrated, reliable, and efficient. By combining a carbon dioxide (CO2) removal system with a resource recovery system like a Sabatier or Bosch reactor, the waste gas from the removal system can be converted into valuable resources that help reduce reliance on ground resupply. Due to the high-pressure nature of the Sabatier and Bosch reactions, the vent gas from most CO2 removal systems will need to be compressed before it can be processed. In order to prevent condensation in the compressor of the recovery system, it is critical to ensure that the vent stream from the CO2 removal system does not contain an excess of water. There are currently two different CO2 removal systems that are being developed as candidates for exploration missions. Each of these systems will be evaluated as a technology demonstration on ISS, and vent gas samples will be collected in Summa sampling canisters fitted with Entech valves for ground analysis. Due to the need to measure low levels of water in these samples, it was not possible to use the current ISS mini-grab sample containers (m-GSC) to collect these samples. The Summa containers, which were used to collect archive samples during Shuttle missions, have a different surface treatment that makes it possible to measure the low levels of water in samples collected in these containers. This paper will provide some background on the CO2 removal systems being evaluated for exploration missions as well as results from ground-based testing of the Summa canisters. Details on the development of the analytical method and the plan for preparing the canisters that will be used for in-flight sampling are also discussed.

William M. King↗

Induction of Three-Dimensional Growth of Human Liver Cells in Simulated Microgravity

We previously reported that a NASA-developed bioreactor that simulates microgravity environment and creates the unique environment of low shear force and high-mass transfer is conducive for maintaining long term 3-D cell cultures of functional hepatocytes (60 days). However, significant further expansion of liver mass, or the remodeling of liver in vitro was jeopardized by the appearance of apoptotic zones in the center of large cell aggregates. To optimize oxygenation and nutritional uptake within growing cellular aggregates we cultured primary human liver cells (HLC) in a bioreactor in the presence or absence of microcarriers and biodegradable scaffolds. Also, to promote angiogenesis, HLC were cultured with or without microvascular endothelial cells. HLC were harvested from human livers by collagenase perfusion. While microcarriers did not affect cell growth, HLC cultured with biodegradable scaffolds made from polyglycolic acid (PGA) formed aggregates up to 3 cm in length. Culturing cells with PGA scaffolds increased the efficiency of cell self-assembly and the formation of larger cell aggregates. Based on histological evaluation it appears that the degree of apoptotic cells was diminished as compared to cultures without scaffolds. Histology of HLC with PGA-scaffolds revealed cell distribution between the fibers of the scaffolds, and cell-cell and cell-fiber interactions. Analyses of HLC spheroids revealed tissue-like structures comprised of hepatocytes, biliary epithelial cells and/or progenitor liver cells that were arranged as bile duct-like structures along nascent vascular sprouts. Electron microscopy revealed groups of cohesive hepatocytes and bile canaliculi with multiple microvilli and tight cellular junctions. Hepatocytes were further organized into tight clusters surrounded by complex stromal structures and reticulin fibers. Also, we observed higher levels of albumin mRNA expression when hepatocytes were co-cultured with endothelial cells. To evaluate viability and microsomal deethylation activity of hepatocytes we assessed the metabolism of midazolam by gas chromatography. Samples that were collected from HLC cultured in the bioreactor contained higher levels of midazolam metabolites (1-OH-midazolam and 4-OH-midazolam) than samples collected from conventional cultures. In summary, we have shown that co-culture of HLC with endothelial cells and/or culturing in the presence of PGA scaffolds provides additional advantages in maintaining functional activity of 3-D hepatocyte cultures that resemble liver tissue. This cell culture system may facilitate studies of liver regeneration and cell-to-cell interactions that occur in vivo and suggest the feasibility of using this approach for pre-clinical metabolic screening of novel drug candidates.

Pellis, Neal R.↗

BOREAS Level-0 C-130 Aerial Photography

For BOReal Ecosystem-Atmosphere Study (BOREAS), C-130 and other aerial photography was collected to provide finely detailed and spatially extensive documentation of the condition of the primary study sites. The NASA C-130 Earth Resources aircraft can accommodate two mapping cameras during flight, each of which can be fitted with 6- or 12-inch focal-length lenses and black-and-white, natural-color, or color-IR film, depending upon requirements. Both cameras were often in operation simultaneously, although sometimes only the lower resolution camera was deployed. When both cameras were in operation, the higher resolution camera was often used in a more limited fashion. The acquired photography covers the period of April to September 1994. The aerial photography was delivered as rolls of large format (9 x 9 inch) color transparency prints, with imagery from multiple missions (hundreds of prints) often contained within a single roll. A total of 1533 frames were collected from the C-130 platform for BOREAS in 1994. Note that the level-0 C-130 transparencies are not contained on the BOREAS CD-ROM set. An inventory file is supplied on the CD-ROM to inform users of all the data that were collected. Some photographic prints were made from the transparencies. In addition, BORIS staff digitized a subset of the tranparencies and stored the images in JPEG format. The CD-ROM set contains a small subset of the collected aerial photography that were the digitally scanned and stored as JPEG files for most tower and auxiliary sites in the NSA and SSA. See Section 15 for information about how to acquire additional imagery.

Newcomer, Jeffrey A.↗

Development and Validation of Sensorimotor Assessment Tasks Using Spaceflight Analogs

INTRODUCTION Exploration class missions will require a new level of crew autonomy to self-assess and treat their sensorimotor dysfunction around periods of gravitational transition, where sensorimotor disturbances are at their highest. There is a need to define sensorimotor assessment thresholds that indicate when performance in early extravehicular activities (EVAs) might be impacted or unsafe. The purpose of this study was to develop and validate a set of assessment tasks using sensorimotor spaceflight analogs including the Sensorimotor Disorientation Analog (SDA) and +3G x sustained centrifugation. METHODS For the SDA, forty-one healthy non-astronaut subjects (21 males, 20 females; Mean ± SD, Age: 34.0 ± 7.8 years) volunteered to participate in this study. Subjects attended two testing sessions: 1) familiarization to the tasks and baseline data collection, and 2) tasks completed under two levels of sensorimotor disorientation. Subjects performed a series of seven sensorimotor assessment tasks followed by two operationally relevant EVA analog tasks. The sensorimotor assessments tasks, ordered from least to most provocative of the sensorimotor system, included: postural stability, step test, prone/supine recovery from fall (RFF), four-square-step-test, obstacle negotiation with turns (OTT), kneel-and-reach, and augmented reality full-body coordination. The operational analog tasks included a top-hatch capsule egress and a 5-minute EVA traversal. Disorientation was applied via the SDA which utilized galvanic vestibular stimulation and weighted trunk, wrists, and ankles to target the vestibular and proprioceptive systems such that performance while wearing the SDA mimicked astronaut postflight performance at R+0 and R+1. Sixteen healthy non-astronaut subjects (10 males, 6 females; Age: 35.0 ± 9.5 years) completed +3G x 60-minute sustained centrifugation as an established spaceflight analog replicating the vestibular disruptions seen postflight. Subjects completed a pre-session which included familiarization to the tasks and a 5-minute centrifuge spin. The data collection session included, in order, a baseline data collection, 60-minute centrifuge spin, immediate post-centrifuge data collection, 45-minute seated recovery, and a final data collection. The same assessment and operational analog tasks were conducted as described above. RESULTS Pearsons’ correlation r-values were calculated between assessment and operational analog tasks. The two assessment tasks with the strongest correlations to the operational analog tasks were the RFF (SDA: r≥ 0.57, Centrifuge: r ≥0.55) and OTT (SDA: r≥ 0.66, Centrifuge: r ≥ 0.49). For brevity, repeated measures ANOVA with follow-up paired t-tests are discussed for these two assessment tasks. The SDA found significant differences between all three levels of disorientation for both RFF and OTT (p < 0.001). Significant differences were also found between baseline and immediate post centrifuge testing for both the RFF (p≤ 0.011) and OTT (p = 0.001). Additional results are forthcoming for both disorientation paradigms. DISCUSSION These validation studies provide evidence for down-selection of the assessment tasks that were able to distinguish between levels of sensorimotor disorientation and correlate to performance in operationally relevant tasks for use in upcoming Artemis missions.

S C Moudy↗