Search NASA⌕ Search

SEARCH · Search NASA

Results for “Computational Method Validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

SU-E-J-246: A Deformation-Field Map Based Liver 4D CBCT Reconstruction Method Using Gold Nanoparticles as Constraints

Purpose: To investigate the feasibility of using nanoparticle markers to validate liver tumor motion together with a deformation field map-based four dimensional (4D) cone-beam computed tomography (CBCT) reconstruction method. Methods: A technique for lung 4D-CBCT reconstruction has been previously developed using a deformation field map (DFM)-based strategy. In this method, each phase of the 4D-CBCT is considered as a deformation of a prior CT volume. The DFM is solved by a motion modeling and free-form deformation (MM-FD) technique, using a data fidelity constraint and the deformation energy minimization. For liver imaging, there is low contrast of a liver tumor in on-board projections. A validation of liver tumor motion using implanted gold nanoparticles, along with the MM-FD deformation technique is implemented to reconstruct onboard 4D CBCT liver radiotherapy images. These nanoparticles were placed around the liver tumor to reflect the tumor positions in both CT simulation and on-board image acquisition. When reconstructing each phase of the 4D-CBCT, the migrations of the gold nanoparticles act as a constraint to regularize the deformation field, along with the data fidelity and the energy minimization constraints. In this study, multiple tumor diameters and positions were simulated within the liver for on-board 4D-CBCT imaging. The on-board 4D-CBCT reconstructed by the proposed method was compared with the “ground truth” image. Results: The preliminary data, which uses reconstruction for lung radiotherapy suggests that the advanced reconstruction algorithm including the gold nanoparticle constraint will Resultin volume percentage differences (VPD) between lesions in reconstructed images by MM-FD and “ground truth” on-board images of 11.5% (± 9.4%) and a center of mass shift of 1.3 mm (± 1.3 mm) for liver radiotherapy. Conclusion: The advanced MM-FD technique enforcing the additional constraints from gold nanoparticles, results in improved accuracy for reconstructing on-board 4D-CBCT of liver tumor. Varian medical systems research grant.

60 APPLIED LIFE SCIENCES↗

Adaptive Breast Radiation Therapy Using Modeling of Tissue Mechanics: A Breast Tissue Segmentation Study

Purpose: To validate and compare the accuracy of breast tissue segmentation methods applied to computed tomography (CT) scans used for radiation therapy planning and to study the effect of tissue distribution on the segmentation accuracy for the purpose of developing models for use in adaptive breast radiation therapy. Methods and Materials: Twenty-four patients receiving postlumpectomy radiation therapy for breast cancer underwent CT imaging in prone and supine positions. The whole-breast clinical target volume was outlined. Clinical target volumes were segmented into fibroglandular and fatty tissue using the following algorithms: physical density thresholding; interactive thresholding; fuzzy c-means with 3 classes (FCM3) and 4 classes (FCM4); and k-means. The segmentation algorithms were evaluated in 2 stages: first, an approach based on the assumption that the breast composition should be the same in both prone and supine position; and second, comparison of segmentation with tissue outlines from 3 experts using the Dice similarity coefficient (DSC). Breast datasets were grouped into nonsparse and sparse fibroglandular tissue distributions according to expert assessment and used to assess the accuracy of the segmentation methods and the agreement between experts. Results: Prone and supine breast composition analysis showed differences between the methods. Validation against expert outlines found significant differences (P<.001) between FCM3 and FCM4. Fuzzy c-means with 3 classes generated segmentation results (mean DSC = 0.70) closest to the experts' outlines. There was good agreement (mean DSC = 0.85) among experts for breast tissue outlining. Segmentation accuracy and expert agreement was significantly higher (P<.005) in the nonsparse group than in the sparse group. Conclusions: The FCM3 gave the most accurate segmentation of breast tissues on CT data and could therefore be used in adaptive radiation therapy-based on tissue modeling. Breast tissue segmentation methods should be used with caution in patients with sparse fibroglandular tissue distribution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hydrodynamic Analysis of a Suspended Cylinder Under Regular Wave Loading Based on Computational Fluid Dynamics

An investigation into the computation of hydrodynamic loads on a suspended cylinder in regular waves is presented. The primary goal was to perform a three-way validation of the loads between experimental measurements and simulations from two computational methods. Experimental measurements of the longitudinal in-line force on a cylinder suspended at a fixed position were available from the Offshore Code Comparison Collaboration, Continued, with Correlation (OC5) project, Phase Ia. These measurements were compared to computational fluid dynamics (CFD) simulations based on the solution of Reynolds-averaged Navier-Stokes (RANS) equations, as implemented in STAR-CCM+. The study encompassed a sensitivity analysis of the loads computed in STAR-CCM+ based on wave modeling, boundary conditions, turbulence modeling, and spatial and temporal discretization. The analysis was supplemented by results generated with the offshore wind turbine engineering software OpenFAST, based on a hybrid combination of second-order potential flow and viscous drag from Morison's equation. The focus of the investigation was on the assessment of the accuracy of the computation of first- and higher-order hydrodynamic loads. Substantial differences were observed in the numerical prediction of the second and third harmonic force contribution. Local flow field analysis with CFD was applied to study the physics of wave run-up and diffraction dynamics to identify the causes.

16 TIDAL AND WAVE POWER↗

Hydrodynamic Analysis of a Suspended Cylinder Under Regular Wave Loading Based on Computational Fluid Dynamics: Preprint

An investigation into the computation of hydrodynamic loads on a suspended cylinder in regular waves is presented. The primary goal was to perform a three-way-validation of the loads between experimental measurements and simulations from two computational methods. Experimental measurements of the longitudinal inline force on a cylinder suspended at a fixed po- sition were available from the Offshore Code Comparison Col- laboration, Continued, with Correlation (OC5) project, Phase Ia. These measurements were compared to Computational Fluid Dynamics (CFD) simulations based on the solution of Reynolds- averaged Navier-Stokes (RANS) equations, as implemented in STAR-CCM plus. The study encompassed a sensitivity analysis of the loads computed in STAR-CCM plus based on wave modeling, boundary conditions, turbulence modeling, and spatial and tem- poral discretization. The analysis was supplemented by results generated with the offshore wind turbine engineering software OpenFAST, based on a hybrid combination of second-order po- tential flow and viscous drag fromMorison's equation. The focus of the investigation was on the assessment of the accuracy of the computation of first- and higher-order hydrodynamic loads. Sub- stantial differences were observed in the numerical prediction of the second and third harmonic force contribution. Local flow field analysis with CFD was applied to study the physics of wave run-up and diffraction dynamics to identify the causes.

16 TIDAL AND WAVE POWER↗

Cone-Beam Computed Tomography Internal Motion Tracking Should Be Used to Validate 4-Dimensional Computed Tomography for Abdominal Radiation Therapy Patients

Purpose: To demonstrate that fiducial tracking during pretreatment Cone-Beam CT (CBCT) can accurately measure tumor motion and that this method should be used to validate 4-dimensional CT (4DCT) margins before each treatment fraction. Methods and Materials: For 31 patients with abdominal tumors and implanted fiducial markers, tumor motion was measured daily with CBCT and fluoroscopy for 202 treatment fractions. Fiducial tracking and maximum-likelihood algorithms extracted 3-dimensional fiducial trajectories from CBCT projections. The daily internal margin (IM) (ie, range of fiducial motion) was calculated for CBCT and fluoroscopy as the 5th-95th percentiles of displacement in each cardinal direction. The planning IM from simulation 4DCT (IM{sub 4DCT}) was considered adequate when within ±1.2 mm (anterior–posterior, left–right) and ±3 mm (superior–inferior) of the daily measured IM. We validated CBCT fiducial tracking as an accurate predictive measure of intrafraction motion by comparing the daily measured IM{sub CBCT} with the daily IM measured by pretreatment fluoroscopy (IM{sub pre-fluoro}); these were compared with pre- and posttreatment fluoroscopy (IM{sub fluoro}) to identify those patients who could benefit from imaging during treatment. Results: Four-dimensional CT could not accurately predict intrafractional tumor motion for ≥80% of fractions in 94% (IM{sub CBCT}), 97% (IM{sub pre-fluoro}), and 100% (IM{sub fluoro}) of patients. The IM{sub CBCT} was significantly closer to IM{sub pre-fluoro} than IM{sub 4DCT} (P<.01). For patients with median treatment time t < 7.5 minutes, IM{sub CBCT} was in agreement with IM{sub fluoro} for 93% of fractions (superior–inferior), compared with 63% for the t > 7.5 minutes group, demonstrating the need for patient-specific intratreatment imaging. Conclusions: Tumor motion determined from 4DCT simulation does not accurately predict the daily motion observed on CBCT or fluoroscopy. Cone-beam CT could replace fluoroscopy for pretreatment verification of simulation IM{sub 4DCT}, reducing patient setup time and imaging dose. Patients with treatment time t > 7.5 minutes could benefit from the addition of intratreatment imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TADSim: Discrete Event-based Performance Prediction for Temperature Accelerated Dynamics

Next-generation high-performance computing will require more scalable and flexible performance prediction tools to evaluate software--hardware co-design choices relevant to scientific applications and hardware architectures. Here, we present a new class of tools called application simulators—parameterized fast-running proxies of large-scale scientific applications using parallel discrete event simulation. Parameterized choices for the algorithmic method and hardware options provide a rich space for design exploration and allow us to quickly find well-performing software--hardware combinations. We demonstrate our approach with a TADSim simulator that models the temperature-accelerated dynamics (TAD) method, an algorithmically complex and parameter-rich member of the accelerated molecular dynamics (AMD) family of molecular dynamics methods. The essence of the TAD application is captured without the computational expense and resource usage of the full code. We accomplish this by identifying the time-intensive elements, quantifying algorithm steps in terms of those elements, abstracting them out, and replacing them by the passage of time. We use TADSim to quickly characterize the runtime performance and algorithmic behavior for the otherwise long-running simulation code. We extend TADSim to model algorithm extensions, such as speculative spawning of the compute-bound stages, and predict performance improvements without having to implement such a method. Validation against the actual TAD code shows close agreement for the evolution of an example physical system, a silver surface. Finally, focused parameter scans have allowed us to study algorithm parameter choices over far more scenarios than would be possible with the actual simulation. This has led to interesting performance-related insights and suggested extensions.

97 MATHEMATICS AND COMPUTING↗

STRUCTURAL ANNOTATION OF EM IMAGES BY GRAPH CUT

Biological images have the potential to reveal complex signatures that may not be amenable to morphological modeling in terms of shape, location, texture, and color. An effective analytical method is to characterize the composition of a specimen based on user-defined patterns of texture and contrast formation. However, such a simple requirement demands an improved model for stability and robustness. Here, an interactive computational model is introduced for learning patterns of interest by example. The learned patterns bound an active contour model in which the traditional gradient descent optimization is replaced by the more efficient optimization of the graph cut methods. First, the energy function is defined according to the curve evolution. Next, a graph is constructed with weighted edges on the energy function and is optimized with the graph cut algorithm. As a result, the method combines the advantages of the level set method and graph cut algorithm, i.e.,"topological" invariance and computational efficiency. The technique is extended to the multi-phase segmentation problem; the method is validated on synthetic images and then applied to specimens imaged by transmission electron microscopy(TEM).

60 APPLIED LIFE SCIENCES↗

Physics-based model for electro-chemical process

Considering the kinetics of electrochemical reactions and mass transfer at the surface and near-surface of the electrode, a physics-based separation model for separating actinides from fission products in an electro-refiner is developed. The model, taking into account the physical, chemical and electrochemical processes at the electrode surface, can be applied to study electrorefining kinetics. One of the methods used for validation has been to apply the developed model to the computation of the cyclic voltammetry process of PuCl{sub 3} and UCl{sub 3} at a solid electrode in molten KCl-LiCl. The computed results appear to be similar to experimental measures. The separation model can be applied to predict materials flows under normal and abnormal operation conditions. Parametric studies can be conducted based on the model to identify the most important factors that affect the electrorefining processes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Computing resonant modes of accelerator cavities by solving nonlinear eigenvalue problems via rational approximation

Here, we present an efficient and reliable algorithm for solving a class of nonlinear eigenvalue problems arising from the modeling of particle accelerator cavities. The eigenvalue nonlinearity in these problems results from the use of waveguides to couple external power sources or to allow certain excited electromagnetic modes to exit the cavity. We use a rational approximation to reduce the nonlinear eigenvalue problem first to a rational eigenvalue problem. We then apply a special linearization procedure to turn the rational eigenvalue problem into a larger linear eigenvalue problem with the same eigenvalues, which can be solved by existing iterative methods. By using a compact scheme to represent both the linearized operator and the eigenvectors to be computed, we obtain a numerical method that only involves solving linear systems of equations of the same dimension as the original nonlinear eigenvalue problem. We refer to this method as a compact rational Krylov (CORK) method. We implemented the CORK method in the Omega3P module of the Advanced Computational Electromagnetic 3D Parallel (ACE3P) simulation suite and validated it by comparing the computed cavity resonant frequencies and damping Q factors of a small model problem to those obtained from a fitting procedure that uses frequency responses computed by another ACE3P module called S3P. We also used the CORK method to compute trapped modes damped in an ideal eight 9-cell SRF cavity cryomodule. This was the first time it was possible to compute these modes directly. The damping Q factors of the computed modes match well with those measured in experiments and the difference in resonant frequencies is within the range introduced by cavity imperfection. Therefore, the CORK method is an extremely valuable tool for computational cavity design.

43 PARTICLE ACCELERATORS↗

Fluid simulations with atomistic resolution: a hybrid multiscale method with field-wise coupling

We present a new hybrid method for simulating dense fluid systems that exhibit multiscale behaviour, in particular, systems in which a Navier–Stokes model may not be valid in parts of the computational domain. We apply molecular dynamics as a local microscopic refinement for correcting the Navier–Stokes constitutive approximation in the bulk of the domain, as well as providing a direct measurement of velocity slip at bounding surfaces. Our hybrid approach differs from existing techniques, such as the heterogeneous multiscale method (HMM), in some fundamental respects. In our method, the individual molecular solvers, which provide information to the macro model, are not coupled with the continuum grid at nodes (i.e. point-wise coupling), instead coupling occurs over distributed heterogeneous fields (here referred to as field-wise coupling). This affords two major advantages. Whereas point-wise coupled HMM is limited to regions of flow that are highly scale-separated in all spatial directions (i.e. where the state of non-equilibrium in the fluid can be adequately described by a single strain tensor and temperature gradient vector), our field-wise coupled HMM has no such limitations and so can be applied to flows with arbitrarily-varying degrees of scale separation (e.g. flow from a large reservoir into a nano-channel). The second major advantage is that the position of molecular elements does not need to be collocated with nodes of the continuum grid, which means that the resolution of the microscopic correction can be adjusted independently of the resolution of the continuum model. This in turn means the computational cost and accuracy of the molecular correction can be independently controlled and optimised. The macroscopic constraints on the individual molecular solvers are artificial body-force distributions, used in conjunction with standard periodicity. We test our hybrid method on the Poiseuille flow problem for both Newtonian (Lennard-Jones) and non-Newtonian (FENE) fluids. The multiscale results are validated with expensive full-scale molecular dynamics simulations of the same case. Very close agreement is obtained for all cases, with as few as two micro elements required to accurately capture both the Newtonian and non-Newtonian flowfields. Our multiscale method converges very quickly (within 3–4 iterations) and is an order of magnitude more computationally efficient than the full-scale simulation.

97 MATHEMATICS AND COMPUTING↗

Simulation of kinematic Kikuchi diffraction patterns from atomistic structures

One of the limitations of atomistic simulations is that many of the computational tools used to extract structural information from atomic trajectories provide metrics that are not directly compatible with experiments for validation. In this work, to bridge between simulation and experiment, a method is presented to produce simulated Kikuchi diffraction patterns using data from atomistic simulations, without requiring a priori specification of the crystal structure or defect periodicity. The Kikuchi pattern simulation is based on the kinematic theory of diffraction, with Kikuchi line intensities computed via a discrete structure factor calculation. Reciprocal lattice points are mapped to Kikuchi lines using a geometric projection of the reciprocal space data. This method is validated using single crystal atomistic models, and the novelty of this approach is emphasized by simulating kinematic Kikuchi diffraction patterns from an atomistic model containing a nanoscale dislocation loop. Deviations in kinematic Kikuchi line intensities are explained considering the displacement field of the dislocation loop, as is done in diffraction contrast theory.

42 ENGINEERING↗

Cross-source sensing data fusion for building occupancy prediction with adaptive lasso feature filtering

Fusing various sensing data sources can significantly improve the accuracy and reliability of building occupancy detection. Fusing environmental sensors and wireless network signals are seldom studied for its computational and technical complexity. Here, this study aims to propose an integrated adaptive lasso model that is able to extract critical data features for environmental and Wi-Fi probe dual sensing sources. Through rapid feature extraction and process simplification, the proposed method aims to improve the computational efficiency of occupancy detecting models. To validate the proposed model, an onsite experiment was conducted to examine two occupancy data resolutions, (real-time and four-level occupancy resolutions). The results suggested that, among all twelve features, eight features are most relevant. The mean absolute error of the real-time occupancy can be reduced to 2.18 and F1_accuracy is about 84.36% for the four-level occupancy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Morphometric Atlas Selection for Automatic Brachial Plexus Segmentation

Purpose: The purpose of this study was to determine the effects of atlas selection based on different morphometric parameters, on the accuracy of automatic brachial plexus (BP) segmentation for radiation therapy planning. The segmentation accuracy was measured by comparing all of the generated automatic segmentations with anatomically validated gold standard atlases developed using cadavers. Methods and Materials: Twelve cadaver computed tomography (CT) atlases (3 males, 9 females; mean age: 73 years) were included in the study. One atlas was selected to serve as a patient, and the other 11 atlases were registered separately onto this “patient” using deformable image registration. This procedure was repeated for every atlas as a patient. Next, the Dice and Jaccard similarity indices and inclusion index were calculated for every registered BP with the original gold standard BP. In parallel, differences in several morphometric parameters that may influence the BP segmentation accuracy were measured for the different atlases. Specific brachial plexus-related CT-visible bony points were used to define the morphometric parameters. Subsequently, correlations between the similarity indices and morphometric parameters were calculated. Results: A clear negative correlation between difference in protraction-retraction distance and the similarity indices was observed (mean Pearson correlation coefficient = −0.546). All of the other investigated Pearson correlation coefficients were weak. Conclusions: Differences in the shoulder protraction-retraction position between the atlas and the patient during planning CT influence the BP autosegmentation accuracy. A greater difference in the protraction-retraction distance between the atlas and the patient reduces the accuracy of the BP automatic segmentation result.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Robust second-order approximation of the compressible Euler equations with an arbitrary equation of state

Here, this paper is concerned with the approximation of the compressible Euler equations supplemented with an arbitrary or tabulated equation of state. The proposed approximation technique is robust, formally second-order accurate in space, invariant-domain preserving, and works for every equation of state, tabulated or analytic, provided the pressure is nonnegative. An entropy surrogate functional that grows across shocks is proposed. The numerical method is verified with novel analytical solutions and then validated with several computational benchmarks seen in the literature including problems with composite waves.

97 MATHEMATICS AND COMPUTING↗

Vision-based inspection of prefabricated components using camera poses: Addressing inherent limitations of image-based 3D reconstruction

Modular construction can lead to additional cost overruns and delays when a defect is found on the construction site and is not easily repairable. Researchers have developed various methods that use image-based 3D reconstruction for quality assessment, but they have inherent limitations, such as inconsistency and dealing with surfaces with reflectivity and limited visual features. Therefore, this paper presents a vision-based quality assessment method using cameras for prefabricated components by addressing these limitations. Specifically, this paper proposes a novel quality inspection method with sub-millimeter accuracy using cameras focused on leveraging camera poses (as opposed to 3D point clouds that are often not consistent in quality) from the image-based 3D reconstruction. The 3D point estimation by computing triangulation was used for achieving accurate measurement. The proposed method is validated using six different variances and two case studies – an aluminum pipe with a reflective surface and a fabricated concrete column. Furthermore, the results demonstrate the accuracy and effectiveness of the proposed method.

42 ENGINEERING↗

Assessing High-Throughput Descriptors for Prediction of Transparent Conductors

The growth of materials databases has offered significant quantities of data to mine for new energy materials using high-throughput screening methodologies. One application of interest to energy and optoelectronics is the prediction of new high performing p-type transparent conductors (TCs). Yet, screening methods for such materials have never been validated over the breadth of computed materials properties. In this study, we compile an experimental data set of 74 bulk crystal structures corresponding to known state-of-the-art n-type and p-type TCs and compute a series of corresponding computational descriptor properties. Our goals are to (1) compare computational descriptors to experimentally demonstrated properties of real materials in the data set, (2) determine the ability of ground state, density functional theory (DFT)-based computational screening methodologies to identify these experimentally realized TCs, and (3) use this understanding to estimate reasonable screening cutoffs for four commonly used descriptors. First, stability calculations demonstrate that most materials in the data set have an energy above the convex hull ( E hull ) of <100 meV/atom, and we also propose a Pourbaix analysis technique to estimate moisture stability. Second, we find a lenient cutoff for the DFT PBE band gap of 0.5 eV is sufficient to include a majority of the wide gap candidates and exclude narrow gap compounds. Next, the effective mass, m *, is found to correlate weakly to conductivity in the p-type materials as compared with n-type materials, which may motivate an increase in the m * cutoff as well. Lastly, we perform an uncertainty analysis and literature comparison for the branch point energy (BPE), a qualitative descriptor for dopability. We discover the BPEs of most n-type materials to lie near the conduction band and those of most p-type materials to lie at midgap; this is a significant distinction, implying BPE to be a more definitive descriptor for n-type TC materials. By assessing the validity of this simple screening methodology via comparing experimental data to computational descriptors, we aim to motivate and strengthen future materials discovery efforts in the field of transparent conductors and beyond.

36 MATERIALS SCIENCE↗

Modeling Structural Colors from Disordered One-Component Colloidal Nanoparticle-Based Supraballs Using Combined Experimental and Simulation Techniques

Bright, saturated structural colors in birds have inspired synthesis of self-assembled, disordered arrays of assembled nanoparticles with varied particle spacings and refractive indices. However, predicting colors of assembled nanoparticles, and thereby guiding their synthesis, remains challenging due to the effects of multiple scattering and strong absorption. In this work, we use a computational approach to first reconstruct the nanoparticles’ assembled structures from small-angle scattering measurements and then input the reconstructed structures to a finite-difference time-domain method to predict their color and reflectance. This computational approach is successfully validated by comparing its predictions against experimentally measured reflectance and provides a pathway for reverse engineering colloidal assemblies with desired optical and photothermal properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Droplet formation simulation using mixed finite elements

Droplet formation happens in finite time due to the surface tension force. The linear stability analysis is useful to estimate the size of a droplet but fails to approximate the shape of the droplet. This is due to a highly nonlinear flow description near the point where the first pinch-off happens. A one-dimensional axisymmetric mathematical model was first developed by Eggers and Dupont [“Drop formation in a one-dimensional approximation of the Navier–Stokes equation,” J. Fluid Mech. 262, 205–221 (1994)] using asymptotic analysis. This asymptotic approach to the Navier–Stokes equations leads to a universal scaling explaining the self-similar nature of the solution. Numerical models for the one-dimensional model were developed using the finite difference [Eggers and Dupont, “Drop formation in a one-dimensional approximation of the Navier–Stokes equation,” J. Fluid Mech. 262, 205–221 (1994)] and finite element method [Ambravaneswaran et al., “Drop formation from a capillary tube: Comparison of one-dimensional and two-dimensional analyses and occurrence of satellite drops,” Phys. Fluids 14, 2606–2621 (2002)]. The focus of this study is to provide a robust computational model for one-dimensional axisymmetric droplet formation using the Portable, Extensible Toolkit for Scientific Computation. The code is verified using the Method of Manufactured Solutions and validated using previous experimental studies done by Zhang and Basaran [“An experimental study of dynamics of drop formation,” Phys. Fluids 7, 1184–1203 (1995)]. The present model is used for simulating pendant drops of water, glycerol, and paraffin wax, with an aspiration of extending the application to simulate more complex pinch-off phenomena.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗