Trilinos software engineering technologies and integration capability area overview.
No abstract prepared.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
No abstract prepared.
The counterflow cooling configuration is a compact, efficient, and relatively low cost thermal management approach for long-length HTS cable systems. In the counter-flow cooling configuration the coolant flow, typically liquid nitrogen, is initially supplied through the center of the cable turning around at the far end of the cable and returning through the annular space between the cable and the inner cryostat wall, using a single cryostat. The temperature distributions along the cable and the nitrogen flow streams are extremely difficult to measure in an operating HTS cable because of the issues associated with installing thermometers on high voltage components. A 5-meter long test loop has been built that simulates a counter-flow cooled, HTS cable using a heated metal tube to simulate the cable. The test loop contains calibrated thermometers to measure the temperature distribution along the tube and the return liquid nitrogen stream. Measured temperature distributions in the return flow stream and along the tube wall for varying flow rates and heating conditions to simulate a HTS cable are presented and discussed.
MixDown is a meta-build tool that orchestrates and manages the building of multiple 3rd party libraries. It can manage the downloading, uncompressing, unpacking, patching, configuration, build, and installation of 3rd party libraries using a variety of configuration and build tools. As a meta-build tool, it relies on 3rd party tools such as GNU Autotools, make, Cmake, scons, etc. to actually confugure and build libraries. MixDown includes an extensive database of settings to be used for general machines and specific leadership class computing resources.
We propose a network architecture with a separate quantum dataplane and a conventional control plane: (a) Quantum Data Plane: The Quantum Data plane consists of links of dark fibers connecting quantum switches and repeaters, which in turn, connect to quantum computers, memory and sensors. Since the current reach is limited to local areas, it will begin as a collection of site networks at laboratories, (b) Conventional Control Plane: The Control plane provides management access to quantum devices for configuration and provisioning via control nodes with firewall and encryption capabilities. Continuous Test and Transition Infrastructure: We propose an infrastructure with a control plane connecting multiple sites via encrypted tunnels over conventional networks consisting of the following: (a) Site Quantum Networks: Individual site networks supported by their fiber plants connect laboratories that house and connect to their quantum devices for testing and interoperability.(b) Site Control Planes: Sites are connected over individual control planes with control hosts with Software Defined Networking capabilities, which can be peered with other networks via ESnet.(c) Progressive Expansion: Initially, sites will develop individual data planes with their specific quantum devices and fiber connections, and mechanisms to interface with conventional networks. They progressively expand and interconnect, under a wide-area ecosystem of peered control planes for device testing, interoperability development and roll off into production environments.
In some embodiments, a battery management system is provided. The battery management system comprises a connector for electrically coupling a battery to the battery management system, at least one sensor configured to detect a battery state, a programmable chip configured to control at least one of charging and discharging of the battery, and a controller device. The controller device is configured to receive at least one battery state from the at least one sensor; provide the at least one battery state as input to a tanks-in-series model that represents the battery; and provide at least one output of the tanks-in-series model to the programmable chip for controlling at least one of charging and discharging of the battery.
Vidi is a Venti proxy that allows certain clients to work when there is no connection to the Venti server. Vidi can be used on computers, such as laptops, to create archives of the file system even when disconnected, and later to transfer the archives to the Venti server. This paper describes an archival configuration used by the author as well the design and implementation of a proxy that allows it to work in a disconnected state.
A thermal management system for a vehicle includes a heat exchanger having a thermal energy storage material provided therein, a first coolant loop thermally coupled to an electrochemical storage device located within the first coolant loop and to the heat exchanger, and a second coolant loop thermally coupled to the heat exchanger. The first and second coolant loops are configured to carry distinct thermal energy transfer media. The thermal management system also includes an interface configured to facilitate transfer of heat generated by an internal combustion engine to the heat exchanger via the second coolant loop in order to selectively deliver the heat to the electrochemical storage device. Thermal management methods are also provided.
A pressure control system may include a plurality of inflatable objects, each of the inflatable objects having a respective pressure sensor and a respective inflation valve, wherein each of the inflation valves has a behavior profile predictive of an amount of current used by the valve when operated. A valve controller of the system may have a pressure management circuit that receives information from the pressure sensors and is configured to automatically maintain a respective selected pressure in each of the inflatable objects by issuing commands to operate the inflation valves. An electrical current management circuit of the valve controller may be configured to predict, based on the valve behavior profiles, what effect the command would have on a total current usage, when executed, and automatically prevent any command that would cause the total current usage to exceed a maximum allowable current.
The Open Science Grid (OSG) relies upon the network as a critical part of the distributed infrastructures it enables. In 2012, OSG added a new focus area in networking with a goal of becoming the primary source of network information for its members and collaborators. This includes gathering, organizing, and providing network metrics to guarantee effective network usage and prompt detection and resolution of any network issues, including connection failures, congestion, and traffic routing. In September of 2015, this service was deployed into the OSG production environment. We will report on the creation, implementation, testing, and deployment of the OSG Networking Service. Starting from organizing the deployment of perfSONAR toolkits within OSG and its partners, to the challenges of orchestrating regular testing between sites, to reliably gathering the resulting network metrics and making them available for users, virtual organizations, and higher level services, all aspects of implementation will be reviewed. In particular, several higher-level services were developed to bring the OSG network service to its full potential. These include a web-based mesh configuration system, which allows central scheduling and management of all the network tests performed by the instances; a set of probes to continually gather metrics from the remote instances and publish it to different sources; a central network datastore (esmond), which provides interfaces to access the network monitoring information in close to real time and historically (up to a year) giving the state of the tests; and a perfSONAR infrastructure monitor system, ensuring the current perfSONAR instances are correctly configured and operating as intended. We will also describe the challenges we encountered in ongoing operations of the network service and how we have evolved our procedures to address those challenges. Finally we will describe our plans for future extensions and improvements to the service.
Figuring out an effective and efficient way to manage not only your Requirement’s Baseline, but also the development of all your individual requirements during a Program’s/Project’s Conceptual and Development Life Cycle Stages can be both daunting and difficult. This is especially so when you are dealing with a complex and large System of Systems (SoS) Program with potentially thousands and thousands of Top Level Requirements as well as an equal number of lower level System, Subsystem and Configuration Item requirements that need to be managed. This task is made even more overwhelming when you have to add in integration with multiple requirements’ development teams (e.g., Integrated Product Development Teams (IPTs)) and/or numerous System/Subsystem Design Teams. One solution for tackling this difficult activity on a recent large System of Systems Program was to develop and make use of a Requirements Screening Group (RSG). This group is essentially a Team made up of co-chairs from the various Stakeholders with an interest in the Program of record that are enabled and accountable for Requirements Development on the Program/Project. The RSG co-chairs, often with the help of individual support team, work together as a Program Board to monitor, make decisions on, and provide guidance on all Requirements Development activities during the Conceptual and Development Life Cycle Stages of a Program/Project. In addition, the RSG can establish and maintain the Requirements Baseline, monitor and enforce requirements traceability across the entire Program, and work with other elements of the Program/Project to ensure integration and coordination.
The Department of Energy (DOE) standardized canister is being re-evaluated to support the management of non-commercial spent nuclear fuel. The standardized canister would allow a broad range of DOE-managed fuels to be loaded, stored, transported, and disposed of while avoiding the need to re-open the canister after initial loading, thus preventing repackaging of the material. A key safety function of this package is to ensure the material maintains a sub-critical configuration for storage, transportation, and disposal. DOE-managed fuels come from a wide range of reactor types, with various cladding materials and enrichments. Many of these reactors, now decommissioned, had unique design features, such as core configuration, fuel element and assembly geometry, moderator and coolant materials, operational characteristics, and neutron spatial and spectral properties resulting in a large diversity of reactor and fuel designs. To adequately address the diversity of DOE spent nuclear fuel (SNF), a number of basket were designed. The basket material needed to have the ability to ensure subcriticality, be structurally sound, and be corrosion resistant. One such option that was investigated in the late-1990s through mid-2000s was a corrosion-resistant, nickel-chromium-molybdenum alloy containing gadolinium, which was termed the advanced neutron absorber (ANA). A number of analyses were performed to verify the structural, corrosive properties, and neutron absorption performances of this material as well as to compare other potential materials to be used for the basket. Gadolinium-containing carbon steel and borated stainless steel were also considered and evaluated. Boral was briefly considered, but due to its corrosive properties. Each of the evaluated materials have strengths and weaknesses. ANA is the best thermal neutron absorber but lacks confirmatory research for corrosion and weldability. Gadolinium containing carbon steel provides excellent moderator exclusion capabilities but does not contain a sufficient supply of phosphate to ensure the gadolinium precipitates. To minimize the probability of a critical configuration, it is highly desirable for the gadolinium to precipate the probability that the materials will remain within the waste packages over the postclosure time periods of interest. Borated stainless steel has structural integrity and impressive corrosion resistance in most environments, but can undergo galvanic corrosion when in close proximity/contact with aluminum and may experience less than desirable corrosion resistance. This report provides an extensive list and comparison of the materials evaluated to ensure sub-criticality of DOE standardized canister in all credible scenarios. More analyses need to be performed using new and updated corrosion information to re-evaluate the neutron absorber that best meets the objectives of the DOE standardized canister.
Traditional building energy modeling with the EnergyPlus building performance simulation engine requires domain expertise, programming skills, and intensive manual efforts limiting its effective adoption. This paper introduces EnergyPlus-MCP, the first open-source Model Context Protocol (MCP) server specifically designed for EnergyPlus simulation workflows, establishing a new foundational infrastructure for AI-driven building energy modeling. The MCP server implements a layered architecture with 35 specialized tools spanning model management, editing and analysis, HVAC and other systems configuration inspection, and simulation execution, enabling Large Language Models to interact with EnergyPlus through conversational interfaces. The server addresses critical workflow barriers by automating model validation, streamlining energy efficiency measures modification, and providing intelligent output management with interactive visualization. Through practical demonstrations using a multi-zone building retrofit analysis, we show how the EnergyPlus-MCP server significantly reduces manual efforts while maintaining full simulation rigor. By providing accessible natural language interfaces to sophisticated building energy analysis, this approach enables scalable deployment of simulation expertise across public and private organizations, educational institutions, and research teams, fundamentally transforming traditional building energy modeling practices.
The 212-N Building at the Hanford Site held fifteen large crates containing glove boxes and process equipment associated with the development and fabrication of mixed oxide (MOX) fuel. The gloveboxes and associated equipment originated from the 308 Building of the Hanford Site and had been placed in the crates after a process upset in the 1960s. The crates were transported to the 212-N Building and had been in storage since 1972. In an effort to reduce the hazard categorization of 212-N the crates were removed from the building and Nondestructive Assay (NDA) was performed to characterize the crate contents meeting both Safeguards and Waste Management interests. A measurement system consisting of four configurable neutron slab detectors and high purity germanium (HPGe) detectors was deployed. Since no viable information regarding the waste matrix and configuration was available it was essential to correct for attenuation with a series of transmission measurements using californium and europium sources for both neutron and gamma applications. The gamma and neutron results obtained during this measurement campaign are compared and discussed in the paper.
Linux is widely used on high-performance computing (HPC) systems, from commodity clusters to Cray su- percomputers (which run the Cray Linux Environment). These platforms primarily differ in their system config- uration: some only use SSH to access compute nodes, whereas others employ full resource management sys- tems (e.g., Torque and ALPS on Cray XT systems). Furthermore, latest improvements in system-level virtualization techniques, such as hardware support, virtual machine migration for system resilience purposes, and reduction of virtualization overheads, enables the usage of virtual machines on HPC platforms. Currently, tools for the management of virtual machines in the context of HPC systems are still quite basic, and often tightly coupled to the target platform. In this docu- ment, we present a new system tool for the management of virtual machines in the context of large-scale HPC systems, including a run-time system and the support for all major virtualization solutions. The proposed solution is based on two key aspects. First, Virtual System Envi- ronments (VSE), introduced in a previous study, provide a flexible method to define the software environment that will be used within virtual machines. Secondly, we propose a new system run-time for the management and deployment of VSEs on HPC systems, which supports a wide range of system configurations. For instance, this generic run-time can interact with resource managers such as Torque for the management of virtual machines. Finally, the proposed solution provides appropriate ab- stractions to enable use with a variety of virtualization solutions on different Linux HPC platforms, to include Xen, KVM and the HPC oriented Palacios.
MOLAR is a multi-institution research effort that concentrates on adaptive, reliable,and efficient operating and runtime system solutions for ultra-scale high-end scientific computing on the next generation of supercomputers. This research addresses the challenges outlined by the FAST-OS - forum to address scalable technology for runtime and operating systems --- and HECRTF --- high-end computing revitalization task force --- activities by providing a modular Linux and adaptable runtime support for high-end computing operating and runtime systems. The MOLAR research has the following goals to address these issues. (1) Create a modular and configurable Linux system that allows customized changes based on the requirements of the applications, runtime systems, and cluster management software. (2) Build runtime systems that leverage the OS modularity and configurability to improve efficiency, reliability, scalability, ease-of-use, and provide support to legacy and promising programming models. (3) Advance computer reliability, availability and serviceability (RAS) management systems to work cooperatively with the OS/R to identify and preemptively resolve system issues. (4) Explore the use of advanced monitoring and adaptation to improve application performance and predictability of system interruptions. The overall goal of the research conducted at NCSU is to develop scalable algorithms for high-availability without single points of failure and without single points of control.
RESTful (REpresentational State Transfer) web services are an alternative implementation to SOAP/RPC web services in a client/server model. BNLs IT Division has started deploying RESTful Web Services for enterprise data retrieval and manipulation. Data is currently used by system administrators for tracking configuration information and as it is expanded will be used by Cyber Security for vulnerability management and as an aid to cyber investigations. This talk will describe the implementation and outstanding issues as well as some of the reasons for choosing RESTful over SOAP/RPC and future directions.
Data centers in the United States consume about two percent of the nation’s electricity. Because heat gains from IT equipment drive cooling demand, data centers offer unique opportunities for energy savings. However, no prototype energy model for data centers is available in the suite of existing U.S. Department of Energy’s Commercial Prototype Building Models. Here we present the development of two new data center prototype models and their implementation in OpenStudio and EnergyPlus. The small-size data center model represents a computer room in a building served by computer room air conditioners (CRACs); while the large-sized model represents stand-alone data centers served by computer room air handlers (CRAHs) with a central chiller plant. For each data center model, two levels of IT equipment (ITE) load density were considered, to cover the wide range of IT power density of data centers: 40 and 100 W/ft 2 (430 and 1076 W/m 2 ) for the computer room, and 100 and 500 W/ft 2 (1076 and 5382 W/m 2 ) for the stand-alone data center. All other assumptions, such as building envelope, lighting, HVAC efficiencies and schedules, were based on the minimal requirements of ASHRAE Standard 90.1 at various vintages. We introduced a novel concept of supply and return air approach temperatures to capture the essential effects of non-uniform airflow and temperature distribution in data centers. The approach temperatures were pre-computed by computational fluid dynamics (CFD) simulations for various configurations of ITE loads and airflow containment management in data centers. A new feature was developed in EnergyPlus to implement the approach temperature method. A case study was conducted to demonstrate the use of the data center models. The two data center models cover all U.S. climate zones and can be used to evaluate energy saving measures for data centers, as well as to support development of data center energy efficiency codes and standards.
Deregulation of the electric utility industry, environmental concerns associated with traditional fossil fuel-based power plants, volatility of electric energy costs, Federal and State regulatory support of “green” energy, and rapid technological developments all support the growth of Distributed Energy Resources (DERs) in electric utility systems and ensure an important role for DERs in the smart grid and other aspects of modern utilities. DERs include distributed generation (DG) systems, such as renewables; controllable loads (also known as demand response); and energy storage systems. This report describes the role of aggregators of DERs in providing optimal services to distribution networks, through DER monitoring and control systems—collectively referred to as a Distributed Energy Resource Management System (DERMS)—and microgrids in various configurations.