The Effect of Asian Dust Aerosols on Cloud Properties and Radiative Forcing from MODIS and CERES

The effects of dust storms on cloud properties and radiative forcing are analyzed over northwestern China from April 2001 to June 2004 using data collected by the Moderate Resolution Imaging Spectroradiometer (MODIS) and Clouds and the Earth's Radiant Energy System (CERES) instruments on the Aqua and Terra satellites. On average, ice cloud effective particle diameter, optical depth and ice water path of the cirrus clouds under dust polluted conditions are 11%, 32.8%, and 42% less, respectively, than those derived from ice clouds in dust-free atmospheric environments. The humidity differences are larger in the dusty region than in the dust-free region, and may be caused by removal of moisture by wet dust precipitation. Due to changes in cloud microphysics, the instantaneous net radiative forcing is reduced from -71.2 W/m2 for dust contaminated clouds to -182.7 W/m2 for dust-free clouds. The reduced cooling effects of dusts may lead to a net warming of 1 W/m2, which, if confirmed, would be the strongest aerosol forcing during later winter and early spring dust storm seasons over the studied region.

Huang, Jianping↗

Investigation of Rotor Wake Effects on Film Cooling

The following are conclusions and recomendations from the study. Primary wake effect is linear reduction in (eta) with St. Secondary wake effect is skewing of suction/pressure side cooling. Steady computations match experimental Nu, but overpredict (eta). Unsteady computations elucidate wake/film interaction. Model may be used to estimate wake passing effect. Need boundary layer and full stage experiments. Need resolved film hole and full stage unsteady computations. Need validated turbulence models for film cooling.

Heidmann, James D.↗

Regeneratively Cooled Liquid Oxygen/Methane Technology Development

The National Aeronautics & Space Administration (NASA) has identified Liquid Oxygen (LOX)/Liquid Methane (LCH4) as a potential propellant combination for future space vehicles based upon exploration studies. The technology is estimated to have higher performance and lower overall systems mass compared to existing hypergolic propulsion systems. NASA-Marshall Space Flight Center (MSFC) in concert with industry partner Pratt & Whitney Rocketdyne (PWR) utilized a Space Act Agreement to test an oxygen/methane engine system in the Summer of 2010. PWR provided a 5,500 lbf (24,465 N) LOX/LCH4 regenerative cycle engine to demonstrate advanced thrust chamber assembly hardware and to evaluate the performance characteristics of the system. The chamber designs offered alternatives to traditional regenerative engine designs with improvements in cost and/or performance. MSFC provided the test stand, consumables and test personnel. The hot fire testing explored the effective cooling of one of the thrust chamber designs along with determining the combustion efficiency with variations of pressure and mixture ratio. The paper will summarize the status of these efforts.

Robinson, Joel W.↗

Regeneratively Cooled Liquid Oxygen/Methane Technology Development Between NASA MSFC and PWR

The National Aeronautics & Space Administration (NASA) has identified Liquid Oxygen (LOX)/Liquid Methane (LCH4) as a potential propellant combination for future space vehicles based upon exploration studies. The technology is estimated to have higher performance and lower overall systems mass compared to existing hypergolic propulsion systems. NASA-Marshall Space Flight Center (MSFC) in concert with industry partner Pratt & Whitney Rocketdyne (PWR) utilized a Space Act Agreement to test an oxygen/methane engine system in the Summer of 2010. PWR provided a 5,500 lbf (24,465 N) LOX/LCH4 regenerative cycle engine to demonstrate advanced thrust chamber assembly hardware and to evaluate the performance characteristics of the system. The chamber designs offered alternatives to traditional regenerative engine designs with improvements in cost and/or performance. MSFC provided the test stand, consumables and test personnel. The hot fire testing explored the effective cooling of one of the thrust chamber designs along with determining the combustion efficiency with variations of pressure and mixture ratio. The paper will summarize the status of these efforts.

Robinson, Joel W.↗

The simulation of the impact of the spatial distribution of vegetation on the urban microclimate: A case study in Mostaganem

Increasing vegetation is one of the solutions proposed to mitigate the phenomenon of urban heat islands. The present research aims to study the effect of the spatial distribution of vegetation on the urban microclimate during the summer period. The city of Mostaganem with its Mediterranean climate was chosen as a case study. Based on meteorological data collected on a hot day in July, the study is carried out using the ENVI-met 4.4.5. Scenarios of different vegetation layouts were carried out. Air, mean radiant and surface temperatures are the microclimatic parameters that have been analyzed for each of the scenarios, and in order to study the outdoor thermal comfort, the Predicted Mean Vote (PMV) is chosen as the comfort index, it compares the average value of the votes of a large group of people on the thermal sensation scale. The study revealed that tree alignments can have a cooling effect on the city temperature close to 1.2◦C. However, its impact on reducing the surface temperature can reach up to 4 ◦C. The introduction of vegetation on the site had the overall effect of lowering the air temperature and therefore relatively improving the level of comfort compared to the reference scenario. But, in order to reduce discomfort to an acceptable level during the day, vegetation can be simultaneously accommodated by city parameters such as urban form.

Nora Bachir↗

A study of Sabatier reactor operation in zero 'G'

The results of zero-g computer model simulation of the operation of a Sabatier reactor, which relies on the effects of buoyant forces, are presented. The reactor was also operated in an experiment with inlet flow rates of carbon dioxide that correspond to continuous operation of the reactor at three, five, eight, and ten-man loading conditions; the three and five-man conditions are noted to be within the design capabilities of the reactor. The loss of carbon dioxide conversion predicted by the model for zero-g environment is noted to be substantial, ranging from 12 to 18.2 percent for five-man to ten-man loading. The simulated normal-gravity values are within 0.9 percent of the experimental conversions. Finally, the results indicate a much hotter operation of the reactor in zero-g due to the loss of natural convective cooling effect.

Forsythe, R. K.↗

Effect of Liner Cooling Flow on Combustor Emissions for Commercial Supersonics Technology

An overview is provided of a parametric study conducted to study the effect of liner cooling airflow rates on NOx emissions of a seven-element lean-direct injection (LDI) module with radial airflow main swirlers. The goal of the CFD study was to determine the increase in cooling flow rate at which the NOx emissions would exceed 20% of the predicted emissions with zero liner cooling flow. The Open version of the National Combustion Code (OpenNCC) was used to perform two-phase reacting flow computations with a new LDI injection module design with radial airflow swirlers instead of axial airflow swirlers. CFD analysis with OpenNCC predicted a 20% increase in EINOx emissions was reached when the liner cooling airflow rate was increased to 15% of the baseline combustor airflow rate. The liner cooling flow rate was predicted to have a non-linear effect on increase in overall EINOx of the seven element LDI injection module.

CFD↗

Effect of Liner Cooling Flow on Combustor Emissions for Commercial Supersonics Technology

An overview is provided of a parametric study conducted to study the effect of liner cooling airflow rates on NOx emissions of a seven-element lean-direct injection (LDI) module with radial airflow main swirlers. The goal of the CFD study was to determine the increase in cooling flow rate at which the NOx emissions would exceed 20% of the predicted emissions with zero liner cooling flow. The Open version of the National Combustion Code (OpenNCC) was used to perform two-phase reacting flow computations with a new LDI injection module design with radial airflow swirlers instead of axial airflow swirlers. CFD analysis with OpenNCC predicted a 20% increase in EINOx emissions was reached when the liner cooling airflow rate was increased to 15% of the baseline combustor airflow rate. The liner cooling flow rate was predicted to have a non-linear effect on increase in overall EINOx of the seven element LDI injection module.

CFD↗

A Study of Direct and Cloud-Mediated Radiative Forcing of Climate Due to Aerosols

The Intergovernmental Panel on Climate Change (IPCC) has reported that in the southeastern US and eastern China, the general greenhouse warming due to anthropogenic gaseous emissions is dominated by the cooling effect of anthropogenic aerosols. To verify this model prediction in eastern China and southeastern US, we analyzed regional patterns of climate changes at 72 stations in eastern China during 1951- 94 (44 years), and at 52 stations in the southeastern US during 1949-94 (46 years) to detect the fingerprint of aerosol radiative forcing. It was found that the mean rates of change of annual mean daily, maximum, minimum temperatures and diurnal temperature range (DTR) in eastern China were 0.8, -0.2, 1.8, and -2.0 C/100 years respectively, while the mean rates of change of annual mean daily, maximum, minimum temperatures and DTR in the southeastern US were -0.2, -0.6, 0.2, and -0.8 C/100 years, respectively. This indicates that the high rate of increase in annual mean minimum temperature in eastern China results in a slightly warming trend of daily temperature, while the high rate of decrease in annual mean maximum temperature and low rate of increase in annual mean minimum temperature lead to the cooling trend of daily temperature in the southeastern US. We found that the warming from the longwave forcing due to both greenhouse gases and aerosols was completely counteracted by the shortwave aerosol forcing in the southeastern US in the past 46 years. A slightly overall warming trend in eastern China is evident; winters have become milder. This finding is explained by hypothesizing that increasing energy usage during the past 44 years has resulted in more coal and biomass burning, thus increasing the emission of absorbing soot and organic aerosols in eastern China. Such emissions, in addition to well-known Asia dust and greenhouse gases, may be responsible for the winter warming trend in eastern China that we have reported here. The sensitivity of aerosol radiative properties to aerosol composition, size distribution, relative humidity (RH) is examined for the following aerosol systems: inorganic and organic ions (Cl-, Br-, NO3 -, SO4 2-, Na+, NH4 +, K+, Ca2+, Mg2+, HCOO-, CH3COO-, CH3CH2COO-, CH3COCOO-, OOCCOO2-, MSA-1); water-insoluble inorganic and organic compounds (elemental carbon, n-alkanes, SiO2, Al2O3, Fe2O3 and other organic compounds). The partial molar refraction method was used to calculate the real part of the refractive index. It was found that the asymmetry factor increased by approximately 48% with the real part varying from 1.40 to 1.65, and the single scattering albedo decreased by 24% with the imaginary part varying from -0.005 to -0.1. The asymmetry factor increased by 5.4 times with the geometric standard deviation varying from 1.2 to 3.0. The radiation transmission is very sensitive to the change in size distribution; other factors are not as significant. To determine the aerosol direct radiative forcing (ADRF), the aerosol optical depth (AOD) values at the three operational wavelengths (415, 500 and 673 nm) were determined at a regionally representative site, namely, Mt. Gibbs (35.78 deg N, 82.29 deg W, elevation 2006 m) in Mt. Mitchell State Park, NC, and a site located in an adjacent valley (Black Mountain, 35.66 deg N, 82.38 deg W, elevation 951 m) in the southeastern US. The two sites are separated horizontally by 10 km and vertically by 1 km. It was found that the representative total AOD values at 500 nm at the valley site for highly polluted (HP), marine (M) and continental (C) air masses were 0.68 +/- 0.33, 0.29 +/- 0.19 and 0.10 +/- 0.04, respectively. A search-graph method was used to retrieve the columnar size distribution (number concentration N, effective radius reff and geometric standard deviation=?g) from the optical depth observations at three operational wavelengths. The ground albedo, single scattering albedo and imaginary part of the refractive index were calculated using a mathematically unique procedure involving a Mie code and a radiative transfer code in conjunction with the retrieved aerosol size distribution, AOD, and diffuse-direct irradiance ratio. It was found that N, r(eff) and sigma(g) were in the ranges of 10 to 1.7 x 10(exp 4)/cubic cm, 0.09 to 0.68 micrometers and 1.12 to 2.95, respectively. The asymmetry factor and single scattering albedo were in the ranges of 0.63 to 0.75 and 0.74 to 0.97 respectively. The ground albedo for the forested terrain and imaginary part of refractive index were found to be in the ranges of 0.06 to 0.29 and 0.005 to 0.051 respectively. On the basis of these aerosol radiative properties obtained at the research sites and computations using the Column Radiation Model (CRM) of National Center of Atmospheric Research (NCAR) Community Climate Model (CCM3), it was found that the average cloud-free 24-hour ADRF values were -13 +/- 8, -8 +/- 3, -33 +/- 16 W/square m for marine, continental, and polluted air masses, respectively. On the assumption that the fractional coverage of clouds is 0.61, it was estimated that the annual mean ADRF was 7 +/- 2 W/square m in the southeastern US. The review with respect to the current knowledge of organic acids shows that aerosol formate and acetate concentrations range from 0.02 to 5.3 nmol/cubic m and from 0.03 to 12.4 nmol/cubic m respectively, and that between 34% to 77% of formate and between 21% to 66% of acetate are present in the fine fraction of aerosols. It was found that although most (98-99%) of these volatile organic acids were present in the gas phase, their concentrations in the aerosol particles were sufficient to make them a good candidate for cloud condensation nuclei (CCN). It is hypothesized that organic acids are at least one of the primary sources of CCN in the atmosphere due to their ubiquitous presence in the troposphere, especially over the continental forested areas. The results of our measurements at Palmer Station, Antarctica show that the daily average CCN concentrations at 0.3% and 1% supersaturations ranged from 0.3 to 160/cubic cm and from 4 to 168/cubic cm, respectively, during the period from 17 January to 26 February, 1994. New evidence for substantial and definitive CCN enhancement near and within cloud has been observed at Mt. Mitchell, North Carolina. The results show that the average monthly CCN concentrations were 460 +/- 217, 386 +/- 286, 429 +/- 228 and 238 +/- 134/cubic cm for in-cloud, overcast, clear and rainy conditions, respectively. The typical CCN spectra show that there were a lot of small CCN produced and the ion concentrations (especially H+ and SO4 2-) were very high during the CCN enhancement period. The significantly positive correlation between black carbon (BC) and CCN at 1% supersaturation indicates that a percentage of the BC measured at the site may be in the form of an internal mixture and participated in the formation of CCN.

Yu, Shao-Cai↗

Carbon dioxide catastrophes: Past and future menace

Carbon dioxide is important in its role as coupler of the terrestrial biosphere to inorganic chemical processes and as the principal greenhouse gas controlling Earth's surface temperature. The hypothesis that atmospheric CO2 levels have diminished with time, with the resulting cooling effect offsetting an increase in the solar constant, seems firmly established, and it is shown that feedback mechanisms exist which can maintain the terrestrial surface in a relatively narrow temperature range over geological time. Of the factors involved in such CO2 variation, the oceanic reservoir appears the most important. Surface waters are probably in approximate equilibrium with regard to CO2 exchange with the ambient atmosphere in most regions, but data from deep-ocean water sampling indicates that such waters are somewhat undersaturated in the sense that they would tend to absorb CO2 from the atmosphere if brought to the surface without change in composition or temperature. If major impacts into the ocean can result in loss of a substantial portion of the atmospheric CO2 reservoir, then any such future event could imperil the continuation of most higher forms of life on Earth. The most likely candidate for an inverse Nyos global event in previous Earth history is the Cretaceous-Tertiary terminal extinction event. The Cretaceous was characterized by warm, equable temperatures presumably indicative of relatively high CO2 levels and an intense greenhouse heating. Cooling of the oceans in absence of massive transfer of CO2 to the oceanic reservoir in itself would promote a condition of CO2 undersaturation in abyssal waters, and this is made even more extreme by the pattern of ocean water circulation. It is possible to envision a situation in which deep ocean waters were at least occasionally profoundly undersaturated with regard to CO2. Turnover of a major fraction of such an ocean would then remove, on a very short time scale, as much as 90 percent of the atmospheric CO2 inventory.

Baur, Mario E.↗

Comparison of heat transfer characteristics of three cooling configurations for air-cooled turbine vanes tested in a turbojet engine

A comparison was made of the heat transfer characteristics of three air cooled vanes. The vanes incorporated cooling schemes such as impingement cooling, film cooling, and convection cooling with and without extended surfaces. A redesign study was made for two vanes to improve the cooling effectiveness. An average impingement heat transfer coefficient was calculated on the bases of experimentally determined temperatures at the leading edge and a one dimensional heat transfer calculation. This heat transfer coefficient was compared with existing impingement heat transfer correlations.

Yeh, F. C.↗