Search NASA⌕ Search

SEARCH · Search NASA

Results for “Count”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Photon Counting Detectors for the 1.0 - 2.0 Micron Wavelength Range

We describe results on the development of greater than 200 micron diameter, single-element photon-counting detectors for the 1-2 micron wavelength range. The technical goals include quantum efficiency in the range 10-70%; detector diameter greater than 200 microns; dark count rate below 100 kilo counts-per-second (cps), and maximum count rate above 10 Mcps.

Krainak, Michael A.↗

In Orbit Performance of Si Avalanche Photodiode Single Photon Counting Modules in the Geoscience Laser Altimeter System on ICESat

Si avalanche photodiode (APD) single photon counting modules (SPCMs) are used in the Geoscience Laser Altimeter System (GLAS) on Ice, Cloud, anti land Elevation Satellite (ICESat), currently in orbit measuring Earth surface elevation and atmosphere backscattering. These SPCMs are used to measure cloud and aerosol backscatterings to the GLAS laser light at 532-nm wavelength with 60-70% quantum efficiencies and up to 15 millions/s maximum count rates. The performance of the SPCMs has been closely monitored since ICESat launch on January 12, 2003. There has been no measurable change in the quantum efficiency, as indicated by the average photon count rates in response to the background light from the sunlit earth. The linearity and the afterpulsing seen from the cloud and surface backscatterings profiles have been the same as those during ground testing. The detector dark count rates monitored while the spacecraft was in the dark side of the globe have increased almost linearly at about 60 counts/s per day due to space radiation damage. The radiation damage appeared to be independent of the device temperature and power states. There was also an abrupt increase in radiation damage during the solar storm in 28-30 October 2003. The observed radiation damage is a factor of two to three lower than the expected and sufficiently low to provide useful atmosphere backscattering measurements through the end of the ICESat mission. To date, these SPCMs have been in orbit for more than three years. The accumulated operating time to date has reached 290 days (7000 hours). These SPCMs have provided unprecedented receiver sensitivity and dynamic range in ICESat atmosphere backscattering measurements.

Sun, X.↗

Effect of Surface Traffic Count on Taxi Time at Dallas-Fort Worth (DFW) International Airport

As the amount of air traffic increases over the years, most airports simply do not have the means of expanding to handle the intensified traffic on the surface that will ensue. Precise surveillance equipment and automation concepts, as well as advanced surface traffic algorithms are being developed to improve airport efficiency. These surface algorithms require inputs unique to each airport to ensure maximum efficiency, and minimal taxi delay. This study analyzes surface traffic at Dallas-Fort Worth International Airport (DFW) to determine the effect of the number of aircraft on the surface and the amount of stop and go situations they experience to the amount of additional taxi time encountered. If the surface capacity of an airport is known, minimal delay can be accomplished by limiting the number of taxiing aircraft to that capacity. This concept is related to highways, where traffic flow drastically decreases as more cars occupy the road. An attempt to minimize this effect on highways is seen with the use of metering lights at freeway on-ramps. Since the surface traffic at airports is highly regulated, and aircraft are less mobile on the ground, limiting the surface count to a certain number can greatly reduce the amount of additional taxi time encountered, as well as reduce hazardous emissions. This study will also find the regions of an airport that encounter the most additional taxi time when the number of aircraft in that area is increased. This could help surface traffic algorithms avoid congesting that area, or re-route aircraft to different runways when that area reaches its capacity. The relationship between the amount of stop and go situations an aircraft encounters and their effect on the taxi time of that aircraft will also be investigated. This will help to determine the effect of holding an aircraft on the taxiway as opposed to re-routing it. The lesser of the two should be used when developing surface traffic algorithms to further minimize the delay encountered. The fields investigated in this study include taxi time, the number of aircraft on the surface, the number of stop and go situations, and the time stopped for each aircraft. Taxi time is defined as spot to runway for departures, and runway to spot for arrivals. It does not include ramp area taxi time because the ramp area is controlled differently, and surface traffic schedulers do not currently incorporate them. Taxi time is found by finding the difference between take-off time (OFF) and spot crossing time for departures, and spot crossing time and landing time (ON) for arrivals. All surface data was either found directly using the Surface Operations Data Analysis and Adaptation (SODAA), a tool to analyze the Surface Management System (SMS) generated log files, or indirectly from SODAA using Matlab to derive values from SODAA data. The number of aircraft on the surface is found by looping through the ON times, OFF times, and spot times for each aircraft during a particular day. For each departure aircraft, surface counts are taken at its spot crossing and OFF time. The average of these two is used as the surface count for that aircraft. For arrivals, surface counts are taken at its ON time and its spot crossing time. The average of these two is used.

Kistler, Matthew Stephen↗

Deep Galex Observations of the Coma Cluster: Source Catalog and Galaxy Counts

We present a source catalog from deep 26 ks GALEX observations of the Coma cluster in the far-UV (FUV; 1530 Angstroms) and near-UV (NUV; 2310 Angstroms) wavebands. The observed field is centered 0.9 deg. (1.6 Mpc) south-west of the Coma core, and has full optical photometric coverage by SDSS and spectroscopic coverage to r-21. The catalog consists of 9700 galaxies with GALEX and SDSS photometry, including 242 spectroscopically-confirmed Coma member galaxies that range from giant spirals and elliptical galaxies to dwarf irregular and early-type galaxies. The full multi-wavelength catalog (cluster plus background galaxies) is 80% complete to NUV=23 and FUV=23.5, and has a limiting depth at NUV=24.5 and FUV=25.0 which corresponds to a star formation rate of 10(exp -3) solar mass yr(sup -1) at the distance of Coma. The GALEX images presented here are very deep and include detections of many resolved cluster members superposed on a dense field of unresolved background galaxies. This required a two-fold approach to generating a source catalog: we used a Bayesian deblending algorithm to measure faint and compact sources (using SDSS coordinates as a position prior), and used the GALEX pipeline catalog for bright and/or extended objects. We performed simulations to assess the importance of systematic effects (e.g. object blends, source confusion, Eddington Bias) that influence source detection and photometry when using both methods. The Bayesian deblending method roughly doubles the number of source detections and provides reliable photometry to a few magnitudes deeper than the GALEX pipeline catalog. This method is also free from source confusion over the UV magnitude range studied here: conversely, we estimate that the GALEX pipeline catalogs are confusion limited at NUV approximately 23 and FUV approximately 24. We have measured the total UV galaxy counts using our catalog and report a 50% excess of counts across FUV=22-23.5 and NUV=21.5-23 relative to previous GALEX measurements, which is not attributed to cluster member galaxies. Our galaxy counts are a better match to deeper UV counts measured with HST.

Hammer, D.↗

Novel Photon-Counting Detectors for Free-Space Communication

We present performance data for novel photon-counting detectors for free space optical communication. NASA GSFC is testing the performance of two types of novel photon-counting detectors 1) a 2x8 mercury cadmium telluride (HgCdTe) avalanche array made by DRS Inc., and a 2) a commercial 2880-element silicon avalanche photodiode (APD) array. We present and compare dark count, photon-detection efficiency, wavelength response and communication performance data for these detectors. We successfully measured real-time communication performance using both the 2 detected-photon threshold and AND-gate coincidence methods. Use of these methods allows mitigation of dark count, after-pulsing and background noise effects. The HgCdTe APD array routinely demonstrated photon detection efficiencies of greater than 50% across 5 arrays, with one array reaching a maximum PDE of 70%. We performed high-resolution pixel-surface spot scans and measured the junction diameters of its diodes. We found that decreasing the junction diameter from 31 micrometers to 25 micrometers doubled the e- APD gain from 470 for an array produced in the year 2010 to a gain of 1100 on an array delivered to NASA GSFC recently. The mean single-photon SNR was over 12 and the excess noise factors measurements were 1.2-1.3. The commercial silicon APD array exhibited a fast output with rise times of 300 ps and pulse widths of 600 ps. On-chip individually filtered signals from the entire array were multiplexed onto a single fast output.

Photons↗

Counts-in-Cylinders in the Sloan Digital Sky Survey with Comparisons to N-Body

Environmental statistics provide a necessary means of comparing the properties of galaxies in different environments and a vital test of models of galaxy formation within the prevailing, hierarchical cosmological model. We explore counts-in-cylinders, a common statistic defined as the number of companions of a particular galaxy found within a given projected radius and redshift interval. Galaxy distributions with the same two-point correlation functions do not necessarily have the same companion count distributions. We use this statistic to examine the environments of galaxies in the Sloan Digital Sky Survey, Data Release 4. We also make preliminary comparisons to four models for the spatial distributions of galaxies, based on N-body simulations, and data from SDSS DR4 to study the utility of the counts-in-cylinders statistic. There is a very large scatter between the number of companions a galaxy has and the mass of its parent dark matter halo and the halo occupation, limiting the utility of this statistic for certain kinds of environmental studies. We also show that prevalent, empirical models of galaxy clustering that match observed two- and three-point clustering statistics well fail to reproduce some aspects of the observed distribution of counts-in-cylinders on 1, 3 and 6-h{sup -1}Mpc scales. All models that we explore underpredict the fraction of galaxies with few or no companions in 3 and 6-h{sup -1} Mpc cylinders. Roughly 7% of galaxies in the real universe are significantly more isolated within a 6 h{sup -1} Mpc cylinder than the galaxies in any of the models we use. Simple, phenomenological models that map galaxies to dark matter halos fail to reproduce high-order clustering statistics in low-density environments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Differential white cell count by centrifugal microfluidics.

We present a method for counting white blood cells that is uniquely compatible with centrifugation based microfluidics. Blood is deposited on top of one or more layers of density media within a microfluidic disk. Spinning the disk causes the cell populations within whole blood to settle through the media, reaching an equilibrium based on the density of each cell type. Separation and fluorescence measurement of cell types stained with a DNA dye is demonstrated using this technique. The integrated signal from bands of fluorescent microspheres is shown to be proportional to their initial concentration in suspension. Among the current generation of medical diagnostics are devices based on the principle of centrifuging a CD sized disk functionalized with microfluidics. These portable 'lab on a disk' devices are capable of conducting multiple assays directly from a blood sample, embodied by platforms developed by Gyros, Samsung, and Abaxis. [1,2] However, no centrifugal platform to date includes a differential white blood cell count, which is an important metric complimentary to diagnostic assays. Measuring the differential white blood cell count (the relative fraction of granulocytes, lymphocytes, and monocytes) is a standard medical diagnostic technique useful for identifying sepsis, leukemia, AIDS, radiation exposure, and a host of other conditions that affect the immune system. Several methods exist for measuring the relative white blood cell count including flow cytometry, electrical impedance, and visual identification from a stained drop of blood under a microscope. However, none of these methods is easily incorporated into a centrifugal microfluidic diagnostic platform.

59 BASIC BIOLOGICAL SCIENCES↗

Count rate limitations in pulsed accelerator fields

This paper discusses various concepts involved in the counting losses of pulse-counting health physics instrumentation when used within the pulsed radiation environments of typical accelerator fields, in order to pre-establish appropriate limitations in use. Discussed are the 'narrow' pulse and the 'wide' pulse cases, the special effect of neutron moderating assemblies, and the effect of pulse microstructure on the counting losses of the pulse-counting instrumentation. Examples are provided which highlight the various concepts and limitations.

43 PARTICLE ACCELERATORS↗

Triangle Counting with Cyclic Distributions

Triangles are the simplest non-trivial subgraphs and triangle counting is used in a number of different applications. The order in which vertices are processed in triangle counting strongly effects the amount of work that needs to be done (and thus the overall performance). Ordering vertices by degree has been shown to be one particularly effective ordering approach. However, for graphs with skewed degree distributions (such as power-law graphs), ordering by degree effects the distribution of work; parallelization must account for this distribution in order to balance work among workers. In this paper we provide an in- depth analysis of the ramifications of degree-based ordering on parallel triangle counting. We present approach for partitioning work in triangle counting, based on cyclic distribution and some surprisingly simple C++ implementations. Experimental results demonstrate the effectiveness of our approach, particularly for power-law (and social network) graphs.

Graph algorithms, parallel algorithms↗

Memory page access counts based on page refresh

A processing system tracks counts of accesses to memory pages using a set of counters located at the memory module that stores the pages, wherein the counts are adjusted at least in part based on refreshes of the memory pages. This approach allows a processing system to efficiently maintain the counts with relatively small counters and with relatively low overhead. Furthermore, the rate at which the counters are adjusted, relative to the page refreshes, is adjustable, so that the access counts are useful for a wide variety of application types.

97 MATHEMATICS AND COMPUTING↗

SQuaD: Smart Quantum Detection for Photon Recognition and Dark Count Elimination

Quantum detectors of single photons are an essential component for quantum information processing across computing, communication and networking. Today's quantum detection system, which consists of single photon detectors, timing electronics, control and data processing software, is primarily used for counting the number of single photon detection events. However, it is largely incapable of extracting other rich physical characteristics of the detected photons, such as their wavelengths, polarization states, photon numbers, or temporal waveforms. This work, for the first time, demonstrates a smart quantum detection system, SQuaD, which integrates a field programmable gate array (FPGA) with a neural network model, and is designed to recognize the features of photons and to eliminate detector dark-count. The SQuaD is a fully integrated quantum system with high timing-resolution data acquisition, onboard multi-scale data analysis, intelligent feature recognition and extraction, and feedback-driven system control. Our \name experimentally demonstrates 1) reliable photon counting on par with the state-of-the art commercial systems; 2) high-throughput data processing for each individual detection events; 3) efficient dark count recognition and elimination; 4) up to 100% accurate feature recognition of photon wavelength and polarization. Additionally, we deploy the SQuaD to an atomic (erbium ion) photon emitter source to realize noise-free control and readout of a spin qubit in the telecom band, enabling critical advances in quantum networks and distributed quantum information processing.

Linne, Karl C. [U. Chicago (main)] (ORCID:00090009↗

Detection of Isotopes in Urban Source Search Low-Count Gamma Spectra Using Hopfield Neural Networks

Source search campaigns involve measurements of background gamma-ray spectra with a mobile detector-spectrometer traveling along arbitrarily chosen trajectories over a wide screening area. Radiation counts are typically measured with a tellurium-doped sodium iodide [NaI(Tl)] scintillator detector-spectrometer in short acquisition intervals, usually 1 s. The objective is to detect orphan isotopes with half-lives shorter than those of the isotopes in the natural background. In principle, radioisotopes can be identified by their unique gamma emission spectrum. However, detecting orphan isotopes in search data is challenging because low counts measured in short acquisition intervals result in incomplete spectral lines. In this study, we investigate the performance of a Hopfield neural network (HNN) that implements an auto-associative memory for the detection of isotopes of interest in an urban search campaign. The HNN is trained on one example of gamma spectra with well-resolved spectral lines of each isotope of interest. During testing, the auto-associative memory implementation of the HNN processes low-count gamma spectra with partially complete isotopic lines by matching incoming measurements to the closest one of its memory-stored patterns. The testing database consisted of almost 10 000 1-s gamma spectra, including measurements of orphan isotopes 137 Cs, 241 Am, and 131 I, obtained during two urban search surveys with a NaI(Tl) detector. The performance of the HNN detection algorithm was evaluated using precision, recall, and F1 scores, and benchmarked with a multiple linear regression (MLR) identification algorithm. In conclusion, the test results demonstrate that HNN outperforms MLR in the detection of all the isotopes of interest.

Auto associative memory↗

235 U Determination using In-Beam Delayed Neutron Counting Technique at the NRU Reactor

This paper describes a collaborative effort that saw the Royal Military College of Canada (RMC)’s delayed neutron and gamma counting apparatus transported to Canadian Nuclear Laboratories (CNL) for use in the neutron beamline at the National Research Universal (NRU) reactor. Samples containing mg quantities of fissile material were re-interrogated, and their delayed neutron emissions measured. This collaboration offers significant advantages to previous delayed neutron research at both CNL and RMC. This paper details the determination of 235 U content in enriched uranium via the assay of in-beam delayed neutron magnitudes and temporal behavior. 235 U mass was determined with an average absolute error of ± 2.7 %. This error is lower than that obtained at RMCC for the assay of 235 U content in aqueous solutions (3.6 %) using delayed neutron counting. Delayed neutron counting has been demonstrated to be a rapid, accurate, and precise method for special nuclear material detection and identification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High precision control and deep learning-based corn stand counting algorithms for agricultural robot

This paper presents high precision control and deep learning-based corn stand counting algorithms for a low-cost, ultra-compact 3D printed and autonomous field robot for agricultural operations. Currently, plant traits, such as emergence rate, biomass, vigor, and stand counting, are measured manually. This is highly labor-intensive and prone to errors. The robot, termed TerraSentia, is designed to automate the measurement of plant traits for efficient phenotyping as an alternative to manual measurements. In this paper, we formulate a Nonlinear Moving Horizon Estimator that identifies key terrain parameters using onboard robot sensors and a learning-based Nonlinear Model Predictive Control that ensures high precision path tracking in the presence of unknown wheel-terrain interaction. Moreover, we develop a machine vision algorithm designed to enable an ultra-compact ground robot to count corn stands by driving through the fields autonomously. The algorithm leverages a deep network to detect corn plants in images, and a visual tracking model to re-identify detected objects at different time steps. We collected data from 53 corn plots in various fields for corn plants around 14 days after emergence (stage V3 - V4). The robot predictions have agreed well with the ground truth with C robot =1.02×C human -0.86 and a correlation coefficient R=0.96. The mean relative error given by the algorithm is -3.78%, and the standard deviation is 6.76%. These results indicate a first and significant step towards autonomous robot-based real-time phenotyping using low-cost, ultra-compact ground robots for corn and potentially other crops.

97 MATHEMATICS AND COMPUTING↗

The Design, Construction, and Initial Characterization of an Ultra-Low-Background Gas-Proportional Counting System

ABSTRACT Over the past several years, the Pacific Northwest National Laboratory (PNNL) has developed an ultra-low background proportional counter (ULBPC) technology. The resulting detector is the product of an effort to produce a low-background, physically robust gas proportional counter for applications like radon emanation measurements, groundwater tritium, and 37Ar. In order to fully take advantage of the inherent low-background properties designed into the ULBPC, a comparably low-background dedicated counting system is required. An ultra-low-background counting system (ULBCS) was recently built in the new shallow underground laboratory at PNNL. With a design depth of 30 meters water-equivalent, the shallow underground laboratory provides approximately 100x fewer fast neutrons and 6x fewer muons than a surface location. The ULBCS itself provides additional shielding in the form of active anti-cosmic veto (via 2-in. thick plastic scintillator paddles) and passive borated poly (1 in.), lead (6 in.), and copper (~3 in.) shielding. This work will provide details on PNNL’s new shallow underground laboratory, examine the motivation for the design of the counting system, and provide results from the characterization of the ULBCS, including initial detector background.

ultra-low-background, proportional counters, shall↗

High pressure Marinelli for counting low activity compressed gas samples

Quantification of low-activity noble gases in air is typically accomplished through separation of the noble gas from air followed by radiometric assay. Here, this work is aimed at quantification of radioactive noble gas in air without extraction. A high pressure aluminum Marinelli counting vessel was designed and fabricated that can be placed on a coaxial high purity germanium detector for gamma counting. Characterization of the performance of this Marinelli using MCNP modeling, large excesses of activity, and low-activity noble gas in air is discussed. Minimum detectable concentrations achieved during a 24 h count are: 5, 10, 50, and 1 Bq/m 3 for 133 Xe, 133m Xe, 131m Xe, and 135 Xe, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An inverse approach to solving zone air infiltration rate and people count using indoor environmental sensor data

Physics-based simulation of energy use in buildings is typically widely used in building design and performance rating, controls design and operations. However, various challenges exist in the modeling process. Model parameters such as people count and air infiltration rate are usually highly uncertain, yet they have significant impacts on the simulation accuracy. With the increasing availability and affordability of sensors and meters in buildings, a large amount of measured data has been collected including indoor environmental parameters, such as room air dry-bulb temperature, humidity ratio, and CO 2 concentration levels. Fusing these sensor data with traditional energy modeling poses new opportunities to improve simulation accuracy. This study develops a set of physics-based inverse algorithms which can solve the highly uncertain and hard-to-measure building parameters such as zone-level people count and air infiltration rate. A simulation-based case study is conducted to verify the inverse algorithms implemented in EnergyPlus covering various sensor measurement scenarios and different modeling use cases. The developed inverse models can solve the zone people count and air infiltration at sub-hourly resolution using the measured zone air temperature, humidity and/or CO 2 concentration given other easy-to-measure model parameters are known.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A zone-level occupancy counting system for commercial office spaces using low-resolution time-of-flight sensors

Understanding the locations of occupants in a commercial built environment is critical for realizing energy savings by delivering lighting, heating, and cooling only where it is needed. In this paper, we present an indoor occupancy counting system using a sparse array of inexpensive, low-resolution, and privacy-preserving time-of-flight sensors. We develop and validate an algorithm for zonal occupancy counting that can deal with multiple people walking underneath the sensors in arbitrary directions, and evaluate the system both in realistic simulations of office spaces and in a real-world installation. Finally, we found that our system has an error rate of around 0.4%, resulting in highly accurate person localization and zone counting using only a few sensors per space.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗