Search NASA⌕ Search

SEARCH · Search NASA

Results for “Criticality Safety Benchmark Experiments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

INDEN Fissile Actinide Issues [Slides]

This presentation addresses the outlook for the International Nuclear Data Evaluation Network (INDEN), specifically regarding general issues that have been solved, including Thermal Neutron Constants (TNC) and Prompt Fission Neutron Spectra (PFNS). Other topics discussed include outstanding issues in fissile evaluations, comments on the RPI quasi-differential experiment, and reaction rate testing of trial evaluations in fast assemblies. The presentation concludes by discussing how INDEN interactions strongly helped to find deficiencies in existing evaluations and highlighted potential solutions to existing challenges, that updated trial evaluations for U-235, U-233, Pu-239 are available for testing, that further work is expected on U-235, Pu-239, and U-233, and that performance was tested on the ICSBEP and/or SINBAD benchmarks, during which significant improvement was demonstrated. The INDEN scheme of international collaboration on nuclear data evaluation is working well.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Pulsed Sphere Time of Flight Neutron Spectrum Measurements: Blank Run and 1.8 Mean-Free-Path thick Polyethylene Moderating Sphere

From the late 1960s to 1985, Lawrence Livermore National Laboratory (LLNL) undertook a series of ‘pulsed sphere’ experiments for 32 materials involving 148 different experiments using 75 different spheres to measure the neutron leakage spectra for different materials from 14-MeV neutrons generated by 3 H(d, n) 4 He reactions induced by an incident D+ beam from the Insulated Core Transformer (ICT) accelerator at LLNL. This deuteron beam was focused to impinge on tritium loaded onto a titanium substrate within a low mass target assembly placed within the center of a spherical shell constructed from the material of interest. The neutron time of flight was measured at a detector outside a collimator. The program was intended to be comprehensive with numerous targets of various thicknesses spanning the periodic table from H to 239 Pu. Five different neutron detectors were utilized to avoid possible systematic errors due to differences in detector responses. Further, these measurements were designed with the aim that the simple geometry of the measurements could be easily simulated to validate Monte Carlo transport codes and nuclear data libraries. As a result, these benchmarks have been extensively used in the validation of ENDL, ENDF and other libraries. Two experiments selected as benchmark cases in this evaluation are: 1) target assembly without material sphere (blank run), and 2) target assembly with a hollow polyethylene sphere, 1.8 mean free path (mfp) or 16.56 cm thick.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Verification of Flux Sensitivity Estimates Using the MCNP Tally Perturbation Tool

Nuclear data is commonly used in applications such as nuclear nonproliferation, safeguards, and criticality safety. More specifically, nuclear data is used in predictive simulation codes like the Monte-Carlo N-Particle (MCNP ® ) transport code, Serpent, and similar radiation transport codes. The improvement of nuclear data enables more precise and accurate simulations, which result in higher fidelity designs and reduced operational/procedural costs. Therefore, the improvement of nuclear data is of paramount importance across the nuclear community. Nuclear data is improved and validated through integral benchmark experiments. The design of benchmark experiments is an extensive process; therefore, these experiments are often optimized on multiple characteristics, including sensitivity to the nuclear data, during the design process. Sensitivity is a measure of how much a quantity changes due to changes in independent variables such as experimental configuration. An experimental design that has a larger sensitivity to the nuclear data of interest will have a larger impact on the accuracy and precision of the validated data. Past integral benchmark experiments have primarily used the effective multiplication factor ($k_{eff}$) as the predominant measured quantity; however, experiments designed with other quantities in mind would be able to optimize on validating different areas of the nuclear data. A primary goal of the EUCLID project is to design, constrain, and reduce compensating errors in experiments focused on quantities other than $k_{eff}$ to better validate nuclear data across the board. Currently, there is a capability in MCNP to easily calculate the sensitivity of $k_{eff}$ to specific nuclear data of numerous reactions types and isotopes (KSEN card); however, the sensitivity of other quantities must be estimated in more strenuous manners. For example, the perturbation feature (PERT card) of MCNP can be used to estimate first-order sensitivities of some response in fixed source simulations. A recent announcement revealed that the first- and second-order perturbation features in previous releases of MCNP contained a bug. It was identified that particles were being scored into the wrong energy bin. The bug is in the most recent public release (MCNP6.2); however, a patch has been added to the most up to date version (MCNP6.2.2) that has not been released publicly. A direct comparison of the PERT card results for an F4 (neutron flux averaged over a cell) tally before and after the patch are shown in figure 1. All simulations used in the sensitivity estimates in this report were performed with MCNP6.2.2. This work verifies the patched MCNP perturbation tool by comparing first order sensitivities made using the PERT card to estimates made using manual perturbation of the compact ENDF (ACE) files.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Estimating List-Mode Data Sensitivities to Nuclear Data with MCNP6

Nuclear data are a vital component of predictive simulations used in applications like experiment design, stockpile stewardship, nuclear nonproliferation/safeguards, health physics, and criticality safety. A singular simulation requires the coalescence of different areas of nuclear data such as cross sections, angular distributions, and energy distributions of emitted neutrons for different materials and energy ranges. Improving nuclear data and thus reducing the uncertainty in simulated parameters could enable smaller, better-informed safety factors and ultimately reduce operational and procedural costs. There is a constant effort to garner a better understanding of the physical quantities represented by nuclear data through experiments. Integral experiment benchmarks use simulated and measured results to validate current nuclear data values. In the past, benchmarks primarily focused on the effective multiplication factor (k eff ); however, this limited scope has caused compensating errors and areas of nuclear data that lack validation. Compensating errors are inaccuracies in nuclear data that are obfuscated by cancellation when observing integrated values such as k eff . Diverse integral benchmark experiments that look for quantities of interest other than k eff and include multiple responses minimize the possibility of compensating errors and provides validation to areas of nuclear data previously lacking experimental validation. Benchmark experiments can be optimized during the design process to be highly dependent on specific areas of nuclear data. The dependence of a response in an experiment to a specific area/type of nuclear data is defined as sensitivity. A larger sensitivity means that nuclear data uncertainties will play a larger role in the response(s) resulting in larger bias. Currently, the sensitivity capabilities of the Monte Carlo N-Particle (MCNP ®1 ) transport code are limited to responses of k eff and tallied values (e.g., flux, surface current). As a part of the EUCLID project, this work explores estimating list-mode nuclear data sensitivities that can be used to design experiments aimed to constrain and reduce compensating errors in nuclear data by focusing on responses other than k eff . Tallied values are ideal quantities that are estimated with detectors during experiments. List-mode data (a list of neutron collection times) are the direct output of detector systems in subcritical neutron noise experiments. Expanding MCNP sensitivity capabilities to include the sensitivity of responses estimated from list-mode data, such as the prompt neutron decay constant (α) and multiplicity estimates (S and D), enables more direct comparison of simulated and measured experimental quantities. Additionally, deterministic tools such as SENSMG are capable of obtaining sensitivities to a wide variety of responses; however, these tools cannot handle complex geometries due to the assumptions made in discretizing the phase-space variables of the Boltzman transport equation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

IER 500: AWE-LLNL Measurement Campaign at DAF [Slides]

Presentation Hosted at Device Assembly Facility (DAF). Joint collaboration by Atomic Weapons Establishment (AWE) and Lawrence Livermore National Laboratory (LLNL). Multiple measurements were recorded through a two-week period with 12 unique objects measured. LLNL deployed Machine learning software program for diagnostic assessments. Current status notes the dedicated DAF team LLNL maintains. Additionally, LLNL is compiling a report on the AWE-LLNL measurements and designing security benchmark experiments. The presentation concludes with future work envisioned.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reproducible benchmark for the SNAP 8 experimental reactor at dry conditions

Here, this work provides fully reproducible benchmark models of the Systems for Nuclear Auxiliary Power (SNAP) 8 Experimental Reactor. Validation benchmarks of the criticality configuration experiments under dry conditions with no coolant are presented. In addition, relevant reactivity worth experiments, and measurement of power distributions are validated and presented here. Discrepancies between modeled and experimental results are at most 110 pcm for fuel and poison worths, and critical configurations that do not manipulate control elements are within 50 pcm. Larger discrepancies found in reflector element worth experiments are due to experimental methodology which was noted as being simplified due to limited calculational capabilities at the time, while discrepancy in the control element manipulated critical configuration is due the absence of structural components for modeling simplification. Power distributions closely follow what was observed in experiment with expected peaking in reflecting elements. All models are well documented with cited references describing and justifying assumptions, simplifications, and adjustments to reproduce the models with any nuclear safety codes; model inputs and outputs are stored in the snapReactors GitHub repository.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

PMT-004 Validation Testing for Thermal Scattering Laws and Some Interesting Temperature-Dependent Implications [Slides]

This presentation finds that PMT-004 has four new benchmark cases highly sensitive to PE TSL (2 cases) and PMMA TSL (2 Cases). Additionally discovered was that the PE cases were well predicted using MCNP6.2 and ENDF/B-VIII.0. PMMA cases overpredicted by approximately 0.6-0.7% in k eff likely due to the lack of integral benchmarks sensitive to PMMA. The NCSU ENDF/B-VIII.1 PMMA TSL is an improvement over VIII.0. This was Accepted at last ICSBEP meeting pending comment resolution, should be published in 2024 version of the Handbook. It was found that temperature had a large impact on reactivity of the critical configuration. This has Implications for validation work for thermal cases- need to adjust TSL data to correct temperature as it can have hundreds of pcm effects for a few °C. Future thermal experiments should try and measure reactivity at multiple temperatures to add in data testing and benchmark adjustment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Update on NNL TSL Evaluations and Validation [Slides]

12 new/revised TSL evaluations were contributed to ENDF/B-VIII.1. The thermal diffusion length $L$ is an integral property of a single material’s absorption and scattering cross sections (both differential and integral). No other neutron reactions or materials are involved. The MC21-calculated $L$ for water is consistent with the spread of experimental data and is sufficiently sensitive to different H-H 2 O TSL physics models to use the method as a TSL integral performance benchmark. Modern high-quality diffusion experiments at elevated $T$ would allow direct low-cost physics benchmarking of water TSLs when public elevated-$T$ critical benchmarks are limited. NNL is working with LLNL and RPI to develop experimental PNDA capability. An ICSBEP Fundamental Physics benchmark of the Nassar and Murphy PNDA experiment is being developed to provide an example of how to evaluate these type of benchmarks.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Godiva 4 CAAS Shielding Benchmark: Pre CED-3A Overview [Slides]

Thiis presentation shows the character of an integral experiment. It covers the question why Godiva 4? Additionally, this presentation touches on the IER 498 benchmark quantity, activities facilitated by IER 498, proposed CED-2 test matrix, and what happened during the IER 498’s gap year.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Completion of Critical Experiments with Molybdenum Sleeves at Sandia

Sandia National Laboratories (SNL) and the Institut de Radioprotection et de Sûreté Nucléaire (IRSN) have collaborated on the design and execution of a set of critical experiments that explore the effects of molybdenum in water moderated fuel-rod arrays. The molybdenum is included as sleeves (tubes) on some of the fuel rods in the arrays. The fuel used in the experiments is known at Sandia as the Seven Percent Critical Experiment (7uPCX) fuel. This fuel has been used is several published benchmark evaluations in including LEU-COMP-THERM-78 and LEU-COMP THERM-080.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Verified, Archived Library of Inputs and Data (VALID) Online Repository [Slides]

VALID continues to serve as a library of high-quality models used for evaluating SCALE and nuclear data. Large number of cases are in the pipeline. Online repository is available for use. Future plans include simplifying the process for adding cases, including additional models outside the ICSBEP Handbook (HTC models, DNCSH models, International Handbook of Evaluated Reactor Physics Benchmark Experiments [IRPhE], SINBAD, etc.), and increasing the availability of models and results for external users.

KENO↗

TEX-HEU Baseline Assemblies: Highly Enriched Uranium Plates with Polyethylene Moderator and Polyethylene Reflector (IER-297 CED-4b Report)

This experiment provides the baseline experimental configurations for TEX-HEU. The purpose of the TEX-HEU design is to provide multiple configurations that span the entire neutron energy spectrum and can be easily modified to incorporate diluent materials. Future experiments utilizing the TEX-HEU design are planned to incorporate hafnium, lithium, and chlorine as diluent materials. Five experimental configurations were judged to be acceptable critical benchmark experiments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Zirconium Scattering Sensitivity in Neutron Transport Calculations of Multiplying Systems [Slides]

This presentation touches on motivation and applications of Zirconium. Performance of evaluated libraries on double and quasi differential experiments is considered. Additionally, the performance of evaluated libraries in select ICSBEP benchmarks is considered. Provided is a detailed look in the performance of evaluated libraries in preliminary benchmark configurations for IER-516: Zirconium Test Assembly (ZTA). Conclusions and recommended experiments to satisfy Zirconium scattering nuclear data needs are presented.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Subcriticality Measurements for a Changing Concentration Uranyl Nitrate Solution Tank by Californium Source-Driven Noise Analysis

Subcritical californium source-driven noise analysis (CSDNA) measurements were performed at the Oak Ridge Critical Experiments Facility in 1983 using a stainless-steel tank with an inside diameter of 76.2 cm and a height of 91.4 cm but only filled with a uranyl (93.16 wt.% 235 U) nitrate solution to a height of 76.2 cm for all measurements. The free acid content of the uranyl nitrate solution was less than 0.01 N to minimize hazards in handling. The total available highly enriched uranium for these measurements was 5,296 g. The concentration of the solution was varied from the highest density of 14.71 grams of uranium per liter (g U/L) initially in 16 steps, lowering the concentration to 0.3492 g U/L, and finally using a tank filled with only water. The tank had a Plexiglas lid to minimize evaporation. The Cf source was contained in a re-entrant Lexan tube which could be in the solution parallel to the axis of the cylindrical tank. The detectors were 3 He proportional counters in the solution in shrink-fit tubing to isolate the counters from the fissile solution and adjacent to the outside of the tank. In some cases, the detectors were scintillators adjacent to the outside of the tank. In other cases, the source was external to the tank. Some data presented in this report are from notes and are not in the logbook. The prompt neutron decay constant was obtained from fitting the date from the CSDNA measurements. The purpose of this report is to document the experimental information for the measurements performed so that later, researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Nuclear Criticality Safety Benchmark Program (ICSBEP) or a Nuclear Energy Agency benchmark. The prompt neutron decay measurements could be the basis of as International Reactor Physic Benchmark Program. The data from these measurements are available from the Records Management Services Department of Oak Ridge National Laboratory, and the logbook is also available from the ICSBEP at Idaho National Laboratory. Preparation of the present report is part of a larger cooperative effort between Idaho National Laboratory (INL) and Oak Ridge National Laboratory (ORNL) to document more than 15 undocumented critical and subcritical experiments enumerated in ORNL/TM-2019/18 and performed by ORNL at ORCEF and other USDOE critical experiments facilities using more than 500 operational days of critical facility time.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

HALEU Experiments [Slides]

The DNCSH, through the HALEU Availability Program, needs publicly available benchmarks supporting Advanced Reactor Fuel Cycle and Transportation. LANL is uniquely positioned to support this goal, with its past experiments at TA-18, planned experiments at NCERC, experiment design capability, and ties to industry. The Deimos experiment will be executed soon and serve as a premier benchmark for the program. LANL expects to submit proposals to the call when issued (soon). Additional experiments supporting DNCSH have already been designed

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Preliminary RAM-RODD results for the MUSiC subcritical configurations

The Measurement of Uranium Subcritical and Critical (MUSiC) was performed at the DOE’s National Criticality Experiments Research Center (NCERC) located in the Nevada National Security Site (NNSS). The measurement utilized the Rocky Flats shells to perform benchmark measurements of similar highly enriched uranium (HEU) systems that span a wide range of reactivities. The Rocky Flats (RF) shells are 93.16% U-235 enriched metal hemishells that can be stacked concentrically. Ten configurations were measured with effective multiplication factors spanning between deeply subcritical (~ 0.64) through delayed critical. Details of the measured configurations are listed in Table 1. This unique set of measurements with its large span of reactivies is being used to determine the range over which neutron noise techniques such as Feynman variance-to-mean, Rossi-alpha, and pulsed neutron source techniques can be accurately employed for a bare HEU system. The results of the measurements will be published as a benchmark in The International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The results will support the growing amount of subcritical benchmark data, such as the SCRaP measurements, that is available to the community. The measurements were performed using several different detector systems for the purposes of cross-validation and obtaining detector independent results. Four detector systems were deployed, three by the NCERC team and one from the University of Michigan. The detector systems included a Neutron Multiplicity Array Detector (NoMAD) system (similar to the MC-15), four small volume 0.635 cm (Ø) × 7.59 cm 3 He detectors (ideal for measuring prompt neutron decay constants due to their fast recovery speed), the Rossi Alpha Measurements – Rapid Organic (n, γ) Discrimination Detector (RAM-RODD), and the Organic Scintillator Array (OSCAR). RAM-RODD is an array of eight 5.08 cm (Ø) × 5.08 cm EJ-309 organic scintillator detectors. OSCAR is a University of Michigan system and is an array of twelve 5.08 cm (Ø) × 5.08 cm stilbene detectors. Details of measurements performed with OSCAR will be discussed in a separate talk. The focus of this work is preliminary results obtained by RAM-RODD for the 8 subcritical configurations. Additional details on the measurements and on the setup and deployment of RAM-RODD will be discussed. Preliminary neutron noise analysis results including Rossi-alpha and Feynman-alpha will also be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements for Flattop-HEU Benchmark Reevaluation

In June 2022, high-fidelity measurements of the Flattop critical assembly were taken at the National Criticality Experiments Research Center (NCERC) at the Nevada National Security Site by a team from Los Alamos National Laboratory, Figure 1. Flattop-HEU is composed of a sphere of highly enriched uranium (HEU) surrounded by a thick spherical natural uranium (NU) reflector as shown in Figure 2 and Figure 3. These measurements were taken as part of the reevaluation of the Flattop-HEU benchmark evaluation for the International Criticality Safety Benchmark Evaluation Program (ICSBEP) Handbook. This reevaluation is being completed to update the benchmark to modern standards with significantly improved fidelity and uncertainty analysis. [1] The measurements address the largest identified uncertainties determined during a preliminary reevaluation in 2015. [2]

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗