Electric vehicle post-crash Recovery—Stranded energy issues and mitigation strategy

In post-crash situations, passengers, bystanders, and first responders are exposed to the immediate safety risks of stranded energy in electric vehicle (EV) batteries. Stranded energy is the energy remaining inside any undamaged or damaged battery following an accident. A potentially damaged battery with an unknown state of safety might go into thermal runaway in the absence of proper monitoring, diagnostics, controls, and handling—thereby leading to potential loss of life and property damage. Therefore, it is imperative to develop standard guidelines, diagnostic methods, and tools to handle stranded energy appropriately and minimize safety risks from immediately after an EV accident to final disposal or re-entry to the road. This perspective paper identifies the challenges associated with handling stranded energy and proposes some potential solution pathways. Further, we hope to draw attention of the research and development community, original equipment manufacturers, and policymakers for motivating new insights and research needs in mitigating safety implications associated with stranded energy.

25 ENERGY STORAGE↗

A Wide Dynamic-Range Halo Monitor for 8 GeV Proton Beams at FNAL

Eliminating harmful beam halos is the most important technique for high-intensity proton accelerators. Therefore, beam halo diagnosis is indispensable and becomes more and more important. At J-PARC, a wide dynamic range monitor was installed in the beam transport line in 2012. The device is a two-dimensional beam profile monitor [*, **], and it has a dynamic range of approximately six digits of magnitude by using Optical Transition Radiation and fluorescence screens. The FNAL accelerator complex has been upgrading through increased beam intensity and beam quality. A new beam halo diagnostic device is required in the beam transport line between the booster and recycler. It will be manufactured in a collaboration between J-PARC and FNAL as a part of the U.S.-Japan Science and Technology Cooperation Program in High Energy Physics. We are redesigning the monitor to satisfy FNAL specifications for beam energy, intensity, and size. The equipment will be manufactured at J-PARC and then shipped to FNAL in 2024. In this report, the design of the device will be described.

43 PARTICLE ACCELERATORS↗

Evaluation of Human Research Facility Ultrasound With the ISS Video System

Most medical equipment on the International Space Station (ISS) is manifested as part of the U.S. or the Russian medical hardware systems. However, certain medical hardware is also available as part of the Human Research Facility. The HRF and the JSC Medical Operations Branch established a Memorandum of Agreement for joint use of certain medical hardware, including the HRF ultrasound system, the only diagnostic imaging device currently manifested to fly on ISS. The outcome of a medical contingency may be changed drastically, or an unnecessary evacuation may be prevented, if clinical decisions are supported by timely and objective diagnostic information. In many higher-probability medical scenarios, diagnostic ultrasound is a first-choice modality or provides significant diagnostic information. Accordingly, the Clinical Care Capability Development Project is evaluating the HRF ultrasound system for its utility in relevant clinical situations on board ISS. For effective management of these ultrasound-supported ISS medical scenarios, the resulting data should be available for viewing and interpretation on the ground, and bidirectional voice communication should be readily available to allow ground experts (sonographers, physicians) to provide guidance to the Crew Medical Officer. It may also be vitally important to have the capability of real-time guidance via video uplink to the CMO-operator during an exam to facilitate the diagnosis in a timely fashion. In this document, we strove to verify that the HRF ultrasound video output is compatible with the ISS video system, identify ISS video system field rates and resolutions that are acceptable for varying clinical scenaiios, and evaluate the HRF ultrasound video with a commercial, off-the-shelf video converter, and compare it with the ISS video system.

Melton, Shannon↗

Lunar Surface Reference Missions: A Description of Human and Robotic Surface Activities

Most medical equipment to the International Space Station (ISS) is manisfested as part of the U.S. or the Russian medical hardware systems. However, certain medical hardware is also available as part of the Human Research Facility. The HRF and the JSC Medical Operations Branch established a Memorandum of Agreement for joint use of certain medical hardware, including the HRF ultrasound system, the only diagnostic imaging device currently manifested to fly on ISS. The outcome of a medical contingency may be changed drastically, or an unnecessary evacuation may be prevented, if clinical decisions are supported by timely and objective diagnostic information. In many higher-probability medical scenarios, diagnostic ultrasound is a first-choice modality or provides significant diagnostic information. Accordingly, the Clinical Care Capability Development Project is evaluating the HRF ultrasound system for its utility in relevant clinical siruations on board ISS. For effective management of these ultrasound-supported ISS medical scenarios, the resulting data should be available for viewing and interpretation on the ground, and bidirectional voice communication should be readily available to allow ground experts (sonographers, physicians) to provide guidance to the Crew Medical Officer. It may also be vitally important to have the capability of real-time guidance via video uplink to the CMO-opertor during an exam to facilitate the diagnosis in a timely fashion.

Duke, Michael B.↗

The potential for plasma diagnostics from stellar extreme-ultraviolet observations

A description of the lines from the most abundant ions in the EUV spectrum in the range 50-500 A that have special diagnostic significance is presented. These lines are from plasmas in the temperature range from 10 exp 5 to 10 exp 7 K. Their utility for determining temperature, density, and abundances is demonstrated. An objective grating spectrometer, based on the Skylab slitless spectrograph, for making celestial observations in the EUV spectral region with high spectral resolution is also described. Such an instrument, if equipped with a multilayer grating, can achieve efficiencies over limited EUV wavelength ranges that rival much larger telescope-spectrometer instruments for the observation of stars and other celestial objects.

Feldman, U.↗

Subspace-Driven Learning for Anomaly Detection in Process Transients

Nuclear power plant (NPP) monitoring and diagnostic centers are actively investigating and implementing automated anomaly detection algorithms to help plants catch anomalies sooner, thereby preventing or reducing the duration of unexpected shutdowns. Current machine learning-based anomaly detection methods are expected to be highly effective during stable, full-power operations because NPPs typically operate as baseload power generators, meaning there are extensive operating data available from plant equipment. However, it is expected that anomaly detection methods will face significant challenges during transient conditions (i.e., when power output falls below full power) because plants only occasionally operate at these lower power levels, generating sparse transient operational data, and resulting in false alarms or missed detections. Here, to address this issue, transfer learning is used, which for this problem leverages knowledge (in the form of learned features) from stable, full-power operations to improve detection accuracy during transient conditions, even with limited data. In this effort, a novel subspace approach is developed to transfer a subset of the data features from full power operation to transients. This approach is validated through experiments using synthetic data and was found to outperform two baseline transfer learning approaches in anomaly detection performance across a range of amounts of transient data used in the training process.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Technology Development to Support Human Health and Performance in Exploration Beyond Low Earth Orbit

In the course of defining the level of risks and mitigating the risks for exploration missions beyond low Earth orbit, NASA s Human Research Program (HRP) has identified the need for technology development in several areas. Long duration missions increase the risk of serious medical conditions due to limited options for return to Earth; no resupply; highly limited mass, power, volume; and communication delays. New space flight compatible medical capabilities required include: diagnostic imaging, oxygen concentrator, ventilator, laboratory analysis (saliva, blood, urine), kidney stone diagnosis & treatment, IV solution preparation and delivery. Maintenance of behavioral health in such an isolated, confined and extreme environment requires new sensory stimulation (e.g., virtual reality) technology. Unobtrusive monitoring of behavioral health and treatment methods are also required. Prolonged exposure to weightlessness deconditions bone, muscle, and the cardiovascular system. Novel exercise equipment or artificial gravity are necessary to prevent deconditioning. Monitoring of the degree of deconditioning is required to ensure that countermeasures are effective. New technologies are required in all the habitable volumes (e.g., suit, capsule, habitat, exploration vehicle, lander) to provide an adequate food system, and to meet human environmental standards for air, water, and surface contamination. Communication delays require the crew to be more autonomous. Onboard decision support tools that assist crew with real-time detection and diagnosis of vehicle and habitat operational anomalies will enable greater autonomy. Multi-use shield systems are required to provide shielding from solar particle events. The HRP is pursuing the development of these technologies in laboratories, flight analog environments and the ISS so that the human health and performance risks will be acceptable with the available resources.

Kundrot, C.E.↗

Smart connected worker edge platform for smart manufacturing: Part 2—Implementation and on‐site deployment case study

Abstract In this paper, we describe specific deployments of the Smart Connected Worker (SCW) Edge Platform for Smart Manufacturing through implementation of four instructive real‐world use cases that illustrate the role of people in a Smart Manufacturing paradigm through which affordable, scalable, accessible, and portable (ASAP) information technology (IT) acquires and contextualizes data into information for transmission to operation technologies (OT). For case one, the platform captures the relationships between energy consumption and human workflows for improved energy productivity while workers interact with machines during semiconductor manufacturing. The platform utilizes human cognition to identify anomalous machine behavior for root cause analysis of system faults via neural network (NN) that recognize alarm postures of workers with cameras. For case two, a smart assembly line is demonstrated for state monitoring and fault detection. Machine learning (ML) models are used to recognize system states and identify fault scenarios with human intervention. For case three, the platform monitors human–machine interactions to classify manufacturing machine states for proper operations and energy productivity. Internal energy states of individual or collections of manufacturing equipment are determined via NN based algorithms that disaggregate signals associated with smart metering typically deployed at manufacturing facilities. These methods predict the real time energy profile of each machine from the total energy profile of a manufacturing site. For case four, a software defined sensor system built with scientific workflow engines is demonstrated for contextualizing data from laser surface refraction for characterization, and diagnostics in the processing of additively manufactured titanium alloy.

Donovan, Richard P.↗

Evolution of radiation protection for medical workers

Within a few months of discovery, X-rays were being used worldwide for diagnosis and within a year or two for therapy. It quickly became clear that while there were significant benefits, there were significant associated hazards, not only for the patients, but also for the operators of the equipment. Simple radiation protection measures were implemented within a decade or two and radiation protection for physicians and other operators has continued to evolve over the last century driven by cycles of widening uses, new technologies, realization of previously unidentified effects, development of recommendations and regulations, along with the rise of related societies and professional organizations. Today, the continue acceleration of medical radiation uses in diagnostic imaging and in therapeutic modalities not imagined at the turn of this century, such as positron emission tomography, calls for constant vigilance and flexibility to provide adequate protection for the growing numbers of medical radiation workers.

61 RADIATION PROTECTION AND DOSIMETRY↗

Fluid Physics and Macromolecular Crystal Growth in Microgravity

The first protein crystallization experiment in microgravity was launched in April, 1981 and used Germany's Technologische Experimente unter Schwerelosigkeit (TEXUS 3) sounding rocket. The protein P-galactosidase (molecular weight 465Kda) was chosen as the sample with a liquid-liquid diffusion growth method. A sliding device brought the protein, buffer and salt solution into contact when microgravity was reached. The sounding rocket gave six minutes of microgravity time with a cine camera and schlieren optics used to monitor the experiment, a single growth cell. In microgravity a strictly laminar diffusion process was observed in contrast to the turbulent convection seen on the ground. Several single crystals, approx 100micron in length, were formed in the flight which were of inferior but of comparable visual quality to those grown on the ground over several days. A second experiment using the same protocol but with solutions cooled to -8C (kept liquid with glycerol antifreeze) again showed laminar diffusion. The science of macromolecular structural crystallography involves crystallization of the macromolecule followed by use of the crystal for X-ray diffraction experiments to determine the three dimensional structure of the macromolecule. Neutron protein crystallography is employed for elucidation of H/D exchange and for improved definition of the bound solvent (D20). The structural information enables an understanding of how the molecule functions with important potential for rational drug design, improved efficiency of industrial enzymes and agricultural chemical development. The removal of turbulent convection and sedimentation in microgravity, and the assumption that higher quality crystals will be produced, has given rise to the growing number of crystallization experiments now flown. Many experiments can be flown in a small volume with simple, largely automated, equipment - an ideal combination for a microgravity experiment. The term "protein crystal growth" is often historically used to describe these microgravity experiments. This is somewhat inaccurate as the field involves the study of many varied biological molecules including viruses, proteins, DNA, RNA and complexes of those structures. For this reason we use the term macromolecular crystal growth. In this chapter we review a series of diagnostic microgravity crystal growth experiments carried out principally using the European Space Agency (ESA) Advanced Protein Crystallization Facility (APCF). We also review related research, both experimental and theoretical, on the aspects of microgravity fluid physics that affect microgravity protein crystal growth. Our experiments have revealed some surprises that were not initially expected. We discuss them here in the context of practical lessons learnt and how to maximize the limited microgravity opportunities available.

Helliwell, John R.↗

Traffic-Light-Preemption Vehicle-Transponder Software Module

A prototype wireless data-communication and control system automatically modifies the switching of traffic lights to give priority to emergency vehicles. The system, which was reported in several NASA Tech Briefs articles at earlier stages of development, includes a transponder on each emergency vehicle, a monitoring and control unit (an intersection controller) at each intersection equipped with traffic lights, and a central monitoring subsystem. An essential component of the system is a software module executed by a microcontroller in each transponder. This module integrates and broadcasts data on the position, velocity, acceleration, and emergency status of the vehicle. The position, velocity, and acceleration data are derived partly from the Global Positioning System, partly from deductive reckoning, and partly from a diagnostic computer aboard the vehicle. The software module also monitors similar broadcasts from other vehicles and from intersection controllers, informs the driver of which intersections it controls, and generates visible and audible alerts to inform the driver of any other emergency vehicles that are close enough to create a potential hazard. The execution of the software module can be monitored remotely and the module can be upgraded remotely and, hence, automatically

Bachelder, Aaron↗

Potential New Sensor for Use With Conventional Gas Carburizing

Diagnostics developed for in-situ monitoring of rocket combustion environments have been adapted for use in heat treating furnaces. Simultaneous, in-situ monitoring of the carbon monoxide, carbon dioxide, methane, water, nitrogen and hydrogen concentrations in the endothermic gas of a heat treating furnace has been demonstrated under a Space Act Agreement between NASA Lewis, the Heat Treating Network, and Akron Steel Treating Company. Equipment installed at the Akron Steel Treating Company showed the feasibility of the method. Clear and well-defined spectra of carbon monoxide, nitrogen and hydrogen were obtained by means of an optical probe mounted on the endothermic gas line of a gas generator inside the plant, with the data reduction hardware located in the basement laboratory. Signals to and from the probe were transmitted via optical fibers.

deGroot, W. A.↗

Simulation and Experimental Measurements of Inductively Coupled CF4 and CF4/Ar Plasmas

The recently developed code SEMS (semiconductor equipment modeling software)is applied to the simulation of CF4 and CF4/Ar inductively coupled plasmas (ICP). This work builds upon the earlier nitrogen, transformer coupled plasma (TCP) SEMS research by demonstrating its accuracy for more complex reactive mixtures, moving closer to the realization of a virtual plasma reactor. Attention is given to the etching of and/or formation of carbonaceous films on the quartz dielectric window and diagnostic aperatures. The simulations are validated through comparisons with experimental measurements using FTIR (Fourier Transform Infrared) and UV absorption spectroscopy for CFx and SiFx neutral radicals, QMS (quadrupole mass spectrometry) for the ions, and Langmuir probe measurements of electron number density and temperature in an ICP GEC reference cell.

Hash, D. B.↗

Space Shuttle Main Engine radio frequency emissions

Several approaches to develop a diagnostics system for monitoring the operational health of the Space Shuttle Main Engine (SSME) are being evaluated. The ultimate goal is providing protection for the SSME as well as improving ground and flight test techniques. One scenario with some potential is measuring radio frequency (RF) emissions (if present) in the exhaust plume and correlating the data to engine health. An RF emissions detection system was therefore designed, the equipment leased, and the components integrated and checked out to conduct a quick-look investigation of RF emissions in the SSME exhaust plume. The system was installed on the A-1 Test Stand at Stennis Space Center, MS, and data were successfully acquired during SSME firings from May 3 to September 15, 1988. The experiments indicated that emitted radiation in the RF (20 to 470 MHz) spectrum definitely exists in the SSME exhaust plume, and is of such magnitude that it can be distinguished during the firing from background noise. Although additional efforts are necessary to assess the merit of this approach as a health monitoring technique, the potential is significant, and additional studies are recommended.

Rester, A. W.↗

The characterization of wear-causing particles and silica sand in particular

Erodants and abradants are two types of wear-causing particles (WCP). Despite their effects on the severity and rate of wear, WCP are inadequately characterized in a surprising number of publications, especially those involving impingement erosion and three-body abrasion. That shortfall makes it difficult to correlate features of WCP with the details of worn surfaces, or to develop wear models that account for those features. It is argued that the documentation of WCP should go beyond simply reporting their composition and mean particle size. In late 1985, ASTM Committee G2 on Wear and Erosion established a task group on the characterization of WCP. At that time, image analysis was slower and less sophisticated than it is today. While that ASTM task group failed to produce a consensus standard, computerized particle characterization methods were developing in fields other than tribology, fields like geoscience, heavy sand mining, materials processing, and pharmaceuticals. A notable exception to this is ferrography, which is a widely-used diagnostic for lubricated tribosystems. In the context of dry wear, it is useful to identify which features of WCP would be beneficial to document, and to identify some techniques and scales of detail appropriate to particular tribosystems. In this paper, examples are presented for the morphological and mechanical characterization of silica sand grains, as prompted by a triboanalysis of the abrasive and erosive wear of biomass pre-processing equipment. The authors propose a minimum level of documentation for WCP, one that can enrich tribosystem analysis both in laboratory tests and field studies.

36 MATERIALS SCIENCE↗

Upgrades to the Thomson Scattering Diagnostic on the Lithium Tokamak eXperiment-Beta (LTX-$β$)

We describe the upgrades to the Thomson scattering (TS) diagnostic on the Lithium Tokamak eXperiment-beta (LTX- β ) to provide complete radial coverage of the plasma. LTX- β is a spherical tokamak with plasma limited at a major radius of R = 14 cm and R = 66 cm. Flat temperature profiles with peaked density were observed in LTX- β using an existing multipoint TS diagnostic with radial coverage of the plasma core. There is a need for more comprehensive core and edge TS measurements to thoroughly examine beam fueling, beam heating, and transport under low recycling conditions with liquid lithium walls and a lower collisionality scrape-off layer (SOL). The core TS set up provides plasma profiles from R = 40–60 cm. To extend the TS diagnostic coverage: 1) we added a TS viewing optics to cover the SOL region at five radial points from R = 57–64 cm, and 2) another TS viewing optics in the HFS region from R = 15–45 cm to obtain TS data from ten radial positions while making use of the original laser beam. The main focus of this article is on the new HFS TS setup that is equipped with better-matched collection optics located in the horizontal midplane where the laser polarization lies and views from a scattering angle of 130°–150° with respect to the laser path. A set of unequal-length Y-branched fiber bundles transports the TS light from two radial points to each polychromator. The new HFS view is better matched in spot size, scattering angle, and throughput to the laser and polychromators and has new V-grooved style viewing dumps. The new HFS TS view, along with the core and SOL TS views, will provide a full radial measurement coverage from R = 15–64 cm to explore the flat temperature profiles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electrical-Impedance-Based Ice-Thickness Gauges

Langley Research Center has developed electrical-impedance-based ice-thickness gauges and is seeking partners and collaborators to commercialize them. When used as parts of active monitoring and diagnostic systems, these gauges make it possible to begin deicing or to take other protective measures before ice accretes to dangerous levels. These gauges are inexpensive, small, and simple to produce. They can be adapted to use on a variety of stationary and moving structures that are subject to accumulation of ice. Examples of such structures include aircraft, cars, trucks, ships, buildings, towers, power lines (see figure), power-generating equipment, water pipes, freezer compartments, and cooling coils. A gauge of this type includes a temperature sensor and two or more pairs of electrically insulated conductors embedded in a surface on which ice could accumulate. The electrical impedances of the pairs of conductors vary with the thickness of any ice that may be present. Somewhat more specifically, when the pairs of conductors are spaced appropriately, the ratio between their impedances is indicative of the thickness of the ice. Therefore, the gauge includes embedded electronic circuits that measure the electrical impedances, plus circuits that process the combination of temperature and impedance measurements to determine whether ice is present and, if so, how thick it is. Of course, in the processing of the impedance measurements, the temperature measurements help the circuitry to distinguish between liquid water and ice. The basic design of a gauge of this type can be adapted to local conditions. For example, if there is a need to monitor ice over a wide range of thickness, then the gauge can include more than two sets of conductors having various spacings.

Weinstein, Leonard↗

Testing of the J-2X Augmented Spark Igniter (ASI) and Its Electronics

Reliable operation of the spark ignition system electronics in the J‐2X Augmented Spark Igniter (ASI) is imperative in assuring ASI ignition and subsequent Main Combustion Chamber (MCC) ignition events are reliable in the J‐2X Engine. Similar to the man‐rated J‐2 and RS‐25 engines, the J‐2X ignition system electronics are equipped with spark monitor outputs intended to indicate that the spark igniters are properly energized and sparking. To better understand anomalous spark monitor data collected on the J‐2X development engines at NASA Stennis Space Center (SSC), a comprehensive subsystem study of the engine's low‐ and high‐tension spark ignition system electronics was conducted at NASA Marshall Space Flight Center (MSFC). Spark monitor output data were compared to more detailed spark diagnostics to determine if the spark monitor was an accurate indication of actual sparking events. In addition, ignition system electronics data were closely scrutinized for any indication of an electrical discharge in some location other than the firing tip of the spark igniter ‐ a problem not uncommon in the development of high voltage ignition systems.