Search NASA⌕ Search

SEARCH · Search NASA

Results for “DIAMONDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Superior wear resistance of diamond and DLC coatings

As the hardest known material, diamond and its coatings continue to generate significant attention for stringent applications involving extreme tribological conditions. Likewise, diamond-like carbon (DLC, especially the tetragonal amorphous carbon, ta-C) coatings have also maintained a high level interest for numerous industrial applications where efficiency, performance, and reliability are of great importance. Additionally, the strong covalent bonding or sp 3 -hybridizaiton in diamond and ta-C coatings assures high mechanical hardness, stiffness, chemical and thermal stability that make them well-suited for harsh tribological conditions involving high-speeds, loads, and temperatures. In particular, unique chemical and mechanical nature of diamond and ta-C surfaces plays an important role in their unusual friction and wear behaviors. As with all other tribomaterials, both diamond and ta-C coatings strongly interact with the chemical species in their surroundings during sliding and hence produce a chemically passive top surface layer which ultimately determines the extent of friction and wear. Thick micro-crystalline diamond films are most preferred for tooling applications, while thinner nano/ultranano-crysalline diamond films are well-suited for mechanical devices ranging from nano- (such as NEMS) to micro- (MEMS and AFM tips) as well as macro-scale devices including mechanical pump seals. The ta-C coatings have lately become indispensable for a variety of automotive applications and are used in very large volumes in tappets, piston pins, rings, and a variety of gears and bearings, especially in the Asian market. This paper is intended to provide a comprehensive overview of the recent developments in tribology of super-hard diamond and DLC (ta-C) films with a special emphasis on their friction and wear mechanisms that are key to their extraordinary tribological performance under harsh tribological conditions. Finally, based on the results of recent studies, the paper will also attempt to highlight what lies ahead for these films in tribology and other demanding industrial applications.

36 MATERIALS SCIENCE↗

Strength and deformation of shocked diamond single crystals: Orientation dependence

Understanding and quantifying the strength or elastic limit of diamond single crystals is of considerable scientific and technological importance, and has been a subject of long standing theoretical and experimental interest. To examine the effect of crystalline anisotropy on strength and deformation of shocked diamond single crystals, plate impact experiments were conducted to measure wave profiles at various elastic impact stresses up to ~120 GPa along [110] and [111] crystal orientations. Using laser interferometry, particle velocity histories and shock velocities in the diamond samples were measured and were compared with similar measurements published previously for shock compression along the [100] direction. Wave profiles for all three orientations showed large elastic wave amplitudes followed by time-dependent inelastic deformation. From the measured wave profiles, the elastic limits were determined under well characterized uniaxial strain loading conditions. The measured elastic wave amplitudes for the [110] and [111] orientations were lower for higher elastic impact stress (stress attained for an elastic diamond response), consistent with the result reported previously for [100] diamond. The maximum resolved shear stress (MRSS) on the {111}<110> slip systems was determined for each orientation, revealing significant orientation dependence. The MRSS values for the [100] and [110] orientations (~33 GPa) are 25-30% of theoretical estimates; the MRSS value for the [111] orientation is significantly lower (~23 GPa). Our results demonstrate that the MRSS depends strongly on the stress component normal to the {111} planes or the resolved normal stress (RNS), suggesting that the RNS plays a key role in inhibiting the onset of inelastic deformation. Lower elastic wave amplitudes at higher peak stress and the effect of the RNS are inconsistent with typical dislocation slip mechanisms of inelastic deformation, suggesting instead an inelastic response characteristic of shocked brittle solids. The present results show that the elastic limit (or material strength) of diamond single crystals cannot be described using traditional isotropic approaches, and typical plasticity models cannot be used to describe the inelastic deformation of diamond. Analysis of the measured wave profiles beyond the elastic limit, including characterization of the peak state, requires numerical simulations that incorporate a time-dependent, anisotropic, inelastic deformation response. Development of such a material description for diamond is an important need.

36 MATERIALS SCIENCE↗

Shock compression of diamond single crystals to 120 GPa: Refractive index and nonlinear photoelasticity

The optical response of transparent solids at extreme conditions is important for both fundamental science and many applications. Strong transparent solids are of particular interest for use as optical windows in dynamic compression experiments. Due to diamond’s exceptional strength and optical properties, laser-driven shock experiments and plate impact experiments were carried out to examine the diamond optical response for shock wave compression along two different crystal orientations. Using laser interferometry at 532 nm and 1550 nm wavelengths, optical transparency was observed and refractive indices were determined for [100] diamond at stresses up to 119 GPa and for [111] diamond at stresses up to 87 GPa. From these results, the nonlinear photoelastic response for [100] and [111] diamond was determined, revealing significant dependence on both crystal orientation and laser wavelength. To enable [100] diamond as an interferometry window in dynamic compression experiments, the requisite window corrections were determined for 532 nm and 1550 nm wavelengths. Because of diamond’s excellent x-ray transparency, the present findings will be particularly useful for incorporating [100] diamonds as windows in dynamic compression experiments involving x-ray diffraction or other x-ray diagnostics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Diamond thin film temperature and heat-flux sensors

Diamond film temperature and heat-flux sensors are developed using a technology compatible with silicon integrated circuit processing. The technology involves diamond nucleation, patterning, doping, and metallization. Multi-sensor test chips were designed and fabricated to study the thermistor behavior. The minimum feature size (device width) for 1st and 2nd generation chips are 160 and 5 micron, respectively. The p-type diamond thermistors on the 1st generation test chip show temperature and response time ranges of 80-1270 K and 0.29-25 microseconds, respectively. An array of diamond thermistors, acting as heat flux sensors, was successfully fabricated on an oxidized Si rod with a diameter of 1 cm. Some problems were encountered in the patterning of the Pt/Ti ohmic contacts on the rod, due mainly to the surface roughness of the diamond film. The use of thermistors with a minimum width of 5 micron (to improve the spatial resolution of measurement) resulted in lithographic problems related to surface roughness of diamond films. We improved the mean surface roughness from 124 nm to 30 nm by using an ultra high nucleation density of 10(exp 11)/sq cm. To deposit thermistors with such small dimensions on a curved surface, a new 3-D diamond patterning technique is currently under development. This involves writing a diamond seed pattern directly on the curved surface by a computer-controlled nozzle.

Aslam, M.↗

Application of Chlorine-Assisted Chemical Vapor Deposition of Diamond at Low Temperatures

Low temperature deposition of diamond has been achieved by a chlorine-assisted diamond chemical vapor deposition (CA-CVD) process. This method begins with the thermal dissociation of molecular chlorine into atomic chlorine in a resistively heated graphite furnace at temperatures between 1300 and 1500 deg. C. The atomic chlorine, upon mixing, subsequently reacts with molecular hydrogen and hydrocarbons. The rapid exchange reactions between the atomic chlorine, molecular hydrogen, and hydrocarbons give rise to the atomic hydrogen and carbon precursors required for diamond deposition. Homoepitaxial diamond growth on diamond substrates has been studied over the substrate temperature range of 100-950 C. It was found that the diamond growth rates are approximately 0.2 microns/hr in the temperature range between 102 and 300 C and that the growth rates do not decrease significantly with a decrease in substrate temperature. This is unique because the traditional diamond deposition using H2/CH4 systems usually disappears at substrate temperatures below approx. 500 deg. C. This opens up a possible route to the deposition of diamond on low-melting point materials such as aluminum and its alloys.

Pan, Chenyu↗

Mechanical design of thin-film diamond crystal mounting apparatus with optimized thermal contact and crystal strain for coherence preservation x-ray optics

A method and mechanical design for a thin-film diamond crystal mounting apparatus for coherence preservation x-ray optics with optimized thermal contact and minimized crystal strain are provided. The novel thin-film diamond crystal mounting apparatus mounts a thin-film diamond crystal supported by a thick chemical vapor deposition (CVD) diamond film spacer with a thickness slightly thicker than the thin-film diamond crystal, and two groups of thin film thermal conductors, such as thin CVD diamond film thermal conductor groups separated by the thick CVD diamond spacer. The two groups of thin CVD film thermal conductors provide thermal conducting interface media with the thin-film diamond crystal. A piezoelectric actuator is integrated into a flexural clamping mechanism generating clamping force from zero to an optimal level.

42 ENGINEERING↗

X-ray quantification of oxygen groups on diamond surfaces for quantum applications

Abstract Identifying the surface chemistry of diamond materials is increasingly important for device applications, especially quantum sensors. Oxygen-related termination species are widely used because they are naturally abundant, chemically stable, and compatible with stable nitrogen vacancy centres near the diamond surface. Diamond surfaces host a mixture of oxygen-related species, and the precise chemistry and relative coverage of different species can lead to dramatically different electronic properties, with direct consequences for near-surface quantum sensors. However, it is challenging to unambiguously identify the different groups or quantify the relative surface coverage. Here we show that a combination of x-ray absorption and photoelectron spectroscopies can be used to quantitatively identify the coverage of carbonyl functional groups on the { 100 } diamond surface. Using this method we reveal an unexpectedly high fraction of carbonyl groups ( > 9%) on a wide range of sample surfaces. Furthermore, through a combination of ab initio calculations and spectroscopic studies of engineered surfaces, we reveal unexpected complexities in the x-ray spectroscopy of oxygen terminated diamond surfaces. Of particular note, we find the binding energies of carbonyl-related groups on diamond differs significantly from other organic systems, likely resulting in previous misestimation of carbonyl fractions on diamond surfaces.

36 MATERIALS SCIENCE↗

Extreme Enhancement-Mode Operation Accumulation Channel Hydrogen-Terminated Diamond FETs with V th < -6 V and High on-Current

In this work, a new Field Effect Transistor device concept based on hydrogen-terminated diamond (H-diamond) is demonstrated that operates in an Accumulation Channel rather than a Transfer Doping regime. The FET devices demonstrate both extreme enhancement-mode operation and high on-current with improved channel charge mobility compared to Transfer-Doped equivalents. Electron-beam evaporated Al 2 O 3 is used on H-diamond to suppress the Transfer Doping mechanism and produce an extremely high ungated channel resistance. A high-quality H-diamond surface with an unpinned Fermi level is crucially achieved, allowing for the formation of a high-density hole accumulation layer by gating the entire device channel which is encapsulated in dual-stacks of Al 2 O 3 . Completed devices with gate/channel length of 1 µm demonstrate record threshold voltage < -6 V with on-current > 80 mA mm -1 . Carrier density and mobility figures extracted by CV analysis indicate a high 2D charge density of ≈ 2 × 10 12 cm -2 and increased hole mobility of 110 cm 2 V -1 s -1 in comparison with more traditional Transfer-Doped H-diamond FETs. These results demonstrate the most negative threshold voltage yet reported for H-diamond FETs and highlight a powerful new strategy to greatly improve carrier mobility and enable enhanced high power and high frequency diamond transistor performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Atomistic evidence of nucleation mechanism for the direct graphite-to-diamond transformation

The direct graphite-to-diamond transformation mechanism has been a subject of intense study and remains debated concerning the initial stages of the conversion, the intermediate phases, and their transformation pathways. Here, we successfully recover samples at the early conversion stage by tuning high-pressure/high-temperature conditions and reveal direct evidence supporting the nucleation-growth mechanism. Atomistic observations show that intermediate orthorhombic graphite phase mediates the growth of diamond nuclei. Furthermore, we observe that quenchable orthorhombic and rhombohedra graphite are stabilized in buckled graphite at lower temperatures. These intermediate phases are further converted into hexagonal and cubic diamond at higher temperatures following energetically favorable pathways in the order: graphite → orthorhombic graphite → hexagonal diamond, graphite → orthorhombic graphite → cubic diamond, graphite → rhombohedra graphite → cubic diamond. Furthermore, these results significantly improve our understanding of the transformation mechanism, enabling the synthesis of different high-quality forms of diamond from graphite.

Graphite-diamond phase transformation↗

Transient current induced in thin film diamonds by swift heavy ions

Single crystal diamond is a suitable material for the next generation particle detectors because of the superior electrical properties and the high radiation tolerance. In order to investigate charge transport properties of diamond particle detectors, transient currents generated in diamonds by single swift heavy ions (26 MeV O 5 + and 45 MeV Si 7 + ) are investigated. We also measured two dimensional maps of transient currents by single ion hits. In the case of 50 μm-thick diamond, both the signal height and the collected charge are reduced by the subsequent ion hits and the charge collection time is extended. Our results are thought to be attributable to the polarization effect in diamond and it appears only when the transient current is dominated by hole current. In the case of 6 μm-thick diamond membrane, an “island” structure is found in the 2D map of transient currents. Signals in the islands shows different applied bias dependence from signals in other regions, indicating different crystal and/or metal contact quality. Simulation study of transient currents based on the Shockley-Ramo theorem clarifies that accumulation of space charges changes distribution of electric field in diamond and causes the polarization effect.

36 MATERIALS SCIENCE↗

The transformation of diamond to graphite: Experiments reveal the presence of an intermediate linear carbon phase

Natural diamonds that have been partially replaced by graphite have been observed to occur in natural rocks. While the graphite-to-diamond phase transition has been extensively studied the opposite of this (diamond to graphite) remains poorly understood. We performed high-pressure and temperature hydrous and anhydrous experiments up to 1.0 GPa and 1300 °C using Amplex premium virgin synthetic diamonds (20–40 μm size) as the starting material mixed with Mg(OH) 2 as a source of H 2 O for the hydrous experiments. The experiments revealed that the diamond-to-graphite transformation at P = 1.0 GPa and T = 1300 °C was triggered by the presence of H 2 O and was accomplished through a three-stage process. Stage 1: diamond reacts with a supercritical H 2 O producing an intermediate 200–500 nm size “globular carbon” phase. This phase is a linear carbon chain; i.e. a polyyne or carbyne. Stage 2: the linear carbon chains are unstable and highly reactive, and they decompose by zigzagging and cross-linking to form sp 2 -hybridized structures. Stage 3: normal, disordered, and onion-like graphite is produced by the decomposition of the sp-hybridized carbon chains which are re-organized into sp 2 bonds. Our experiments show that there is no direct transformation from sp 3 C-bonds into sp 2 C-bonds. Our hydrous high-pressure and high-temperature experiments show that the diamond-to-graphite transformation requires an intermediate metastable phase of a linear hydrocarbon. This process also provides a simple mechanism for the substitution of other elements into the graphite structure (e.g. H, S, O).

36 MATERIALS SCIENCE↗

Diamond Electronic Devices

For high-power and high-voltage applications, silicon is by far the dominant semiconductor material. However, silicon has many limitations, e.g. a relatively low thermal conductivity, electric breakdown occurs at relatively low fields and the bandgap is 1.1 eV which effectively limits operation to temperatures below 175 deg.n C. Wide-bandgap materials, such as silicon carbide (SiC), gallium nitride (GaN) and diamond offer the potential to overcome both the temperature and power handling limitations of silicon. Diamond is the most extreme in this class of materials. By the fundamental material properties alone, diamond offers the largest benefits as a semiconductor material for power electronic applications. On the other hand, diamond has a problem with a large carrier activation energy of available dopants which necessitates specialised device concepts to allow room temperature (RT) operation. In addition, the role of common defects on the charge transport properties of diamond is poorly understood. Notwithstanding this, many proof-of-principle two-terminal and three-terminal devices have been made and tested. Two-terminal electronic diamond devices described in the literature include: p-n diodes, p-i-n diodes, various types of radiation detectors, Schottky diodes and photoconductive or electron beam triggered switches. Three terminal devices include e.g. MISFETs and JFETs. However, the development of diamond devices poses great challenges for the future. A particularly interesting way to overcome the doping problem, for which there has been some recent progress, is to make so-called delta doped (or pulse-doped) devices. Such devices utilise very thin ({approx}1 nm) doped layers in order to achieve high RT activation.

36 MATERIALS SCIENCE↗

Direct observation of electron emission from the grain boundaries of chemical vapour deposition diamond films by tunneling atomic force microscopy

The emission of electrons from diamond in vacuum occurs readily as a result of the negative electron affinity of the hydrogenated surface due to features with nanoscale dimensions, which can concentrate electric fields high enough to induce electron emission from them. Electrons can be emitted as a result of an applied electric field (field emission) with possible uses in displays or cold-cathode devices. Alternatively, electrons can be emitted simply by heating the diamond in vacuum to temperatures as low as 350 °C (thermionic emission), and this may find applications in solar energy generation or energy harvesting devices. Electron emission studies usually use doped polycrystalline diamond films deposited onto Si or metallic substrates by chemical vapor deposition, and these films have a rough, faceted morphology on the micron or nanometer scale. Electron emission is often improved by patterning the diamond surface into sharp points or needles, the idea being that the field lines concentrate at the points lowering the barrier for electron emission. However, there is little direct evidence that electrons are emitted from these sharp tips. The few reports in the literature that have studied the emission sites suggested that emission came from the grain boundaries and not the protruding regions. We now present direct observation of the emission sites over a large area of polycrystalline diamond using tunneling atomic force microscopy. We confirm that the emission current comes mostly from the grain boundaries, which is consistent with a model for emission in which the non-diamond phase is the source of electrons with a threshold that is determined by the surrounding hydrogenated diamond surface.

36 MATERIALS SCIENCE↗

Nitrogen termination of single crystal (100) diamond surface by radio frequency N{sub 2} plasma process: An in-situ x-ray photoemission spectroscopy and secondary electron emission studies

In this letter, we report the electronic and chemical properties of nitrogen terminated (N-terminated) single crystal (100) diamond surface, which is a promising candidate for shallow NV{sup −} centers. N-termination is realized by an indirect RF nitrogen plasma process without inducing a large density of surface defects. Thermal stability and electronic property of N-terminated diamond surface are systematically investigated under well-controlled conditions by in-situ x-ray photoelectron spectroscopy and secondary electron emission. An increase in the low energy cut-off of the secondary electron energy distribution curve (EDC), with respect to a bare diamond surface, indicates a positive electron affinity of the N-terminated diamond. Exposure to atomic hydrogen results in reorganization of N-terminated diamond to H-terminated diamond, which exhibited a negative electron affinity surface. The change in intensity and spectral features of the secondary electron EDC of the N-terminated diamond is discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hydrogen-terminated diamond vertical-type metal oxide semiconductor field-effect transistors with a trench gate

The hydrogen-terminated diamond surface (C-H diamond) has a two-dimensional hole gas (2DHG) layer independent of the crystal orientation. A 2DHG layer is ubiquitously formed on the C-H diamond surface covered by atomic-layer-deposited-Al{sub 2}O{sub 3}. Using Al{sub 2}O{sub 3} as a gate oxide, C-H diamond metal oxide semiconductor field-effect transistors (MOSFETs) operate in a trench gate structure where the diamond side-wall acts as a channel. MOSFETs with a side-wall channel exhibit equivalent performance to the lateral C-H diamond MOSFET without a side-wall channel. Here, a vertical-type MOSFET with a drain on the bottom is demonstrated in diamond with channel current modulation by the gate and pinch off.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

XPS analysis of molecular contamination and sp 2 amorphous carbon on oxidized (100) diamond

The efficacy of oxygen (O) surface terminations on diamond is an important factor for the performance and stability for diamond-based quantum sensors and electronics. Given the wide breadth of O-termination techniques, it can be difficult to discern which method would yield the highest and most consistent O coverage. Furthermore, the interpretation of surface characterization techniques is complicated by surface morphology and purity, which if not accounted for will yield inconsistent determination of the oxygen coverage. We present a comprehensive approach to consistently prepare and analyze oxygen termination of surfaces on (100) single-crystalline diamond. We report on x-ray photoelectron spectroscopy (XPS) characterization of diamond surfaces treated with six oxidation methods that include various wet chemical oxidation techniques, photochemical oxidation with UV illumination, and steam oxidation using atomic layer deposition (ALD). Our analysis entails a rigorous XPS peak-fitting procedure for measuring the functionalization of O-terminated diamond. The findings herein have provided molecular-level insights on oxidized surfaces in (100) diamond, including the demonstration of clear correlation between the measured oxygen atomic percentage and the presence of molecular contaminants containing nitrogen, silicon, and sulfur. We also provide a comparison of the sp 2 carbon content with the O1s atomic percentage and discern a correlation with the diamond samples treated with dry oxidation which eventually tapers off at a max O1s atomic percentage value of 7.09 ± 0.40%. Given these results, we conclude that the dry oxidation methods yield some of the highest oxygen amounts, with the ALD water vapor technique proving to be the cleanest technique out of all the oxidation methods explored in this work.

XPS↗

Characterization of a synthetic single crystal diamond Schottky diode for radiotherapy electron beam dosimetry

Purpose: To investigate the dosimetric properties of synthetic single crystal diamond based Schottky diodes under irradiation with therapeutic electron beams from linear accelerators. Methods: A single crystal diamond detector was fabricated and tested under 6, 8, 10, 12, and 15 MeV electron beams. The detector performances were evaluated using three types of commercial detectors as reference dosimeters: an Advanced Markus plane parallel ionization chamber, a Semiflex cylindrical ionization chamber, and a p-type silicon detector. Preirradiation, linearity with dose, dose rate dependence, output factors, lateral field profiles, and percentage depth dose profiles were investigated and discussed. Results: During preirradiation the diamond detector signal shows a weak decrease within 0.7% with respect to the plateau value and a final signal stability of 0.1% (1{sigma}) is observed after about 5 Gy. A good linear behavior of the detector response as a function of the delivered dose is observed with deviations below {+-}0.3% in the dose range from 0.02 to 10 Gy. In addition, the detector response is dose rate independent, with deviations below 0.3% in the investigated dose rate range from 0.17 to 5.45 Gy/min. Percentage depth dose curves obtained from the diamond detector are in good agreement with the ones from the reference dosimeters. Lateral beam profile measurements show an overall good agreement among detectors, taking into account their respective geometrical features. The spatial resolution of solid state detectors is confirmed to be better than that of ionization chambers, being the one from the diamond detector comparable to that of the silicon diode. A good agreement within experimental uncertainties was also found in terms of output factor measurements between the diamond detector and reference dosimeters. Conclusions: The observed dosimetric properties indicate that the tested diamond detector is a suitable candidate for clinical electron beam dosimetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-570: Comparison of Synthetic Diamond, Microionization Chamber, and Radiochromic Film for Absolute Dosimetry of VMAT Radiosurgery

Purpose: Patient specific quality assurance of stereotactic radiosurgery (SRS) plans is challenging because of small target sizes and high dose gradients. We compared three detectors for dosimetry of VMAT SRS plans. Methods: The dose at the center of seventeen targets was measured using a synthetic diamond detector (2.2 mm diameter, 1 µm thickness), a 0.007 cm{sup 3} ionization chamber, and radiochromic film. Measurements were made in a PMMA phantom in the clinical geometry – all gantry and table angles were delivered as planned. The diamond and chamber positions were offset by 1 cm from the film plane, so the isocenter was shifted accordingly to place the center of the target at the detector of interest. To ensure accurate detector placement, the phantom was positioned using kV images. To account for the shift-induced difference in geometry and differing prescription doses between plans, the measurements were normalized to the expected dose calculated by the treatment planning system. Results: The target sizes ranged from 2.8 mm to 34.8 mm (median 14.8 mm). The mean measurement-to-plan ratios were 1.054, 1.076, and 1.023 for RCF, diamond, and chamber, respectively. The mean difference between the chamber and film was −3.2% and between diamond and film was 2.2%. For targets larger than 15 mm, the mean difference relative to film was −0.8% and 0.1% for chamber and diamond, respectively, whereas for targets smaller than 15 mm, the difference was −5.3% and 4.2% for chamber and diamond, respectively. The difference was significant (p=0.005) using the two-sample Kolmogorov-Smirnov test. Conclusion: The detectors agree for target sizes larger than 15 mm. Relative to film, for smaller targets the diamond detector over-responds, whereas the ionization chamber under-responds. Further work is needed to characterize detector response in modulated SRS fields.

60 APPLIED LIFE SCIENCES↗