Search NASA⌕ Search

SEARCH · Search NASA

Results for “DIAPHRAGM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Optically Driven Deformable Mirrors

Optically driven deformable mirrors may eventually supplant electrically driven deformable mirrors in some adaptive-optics and active-optics applications. Traditionally, the mirror facets in electrically driven deformable mirrors are actuated, variously, by means of piezoelectric, electrostrictive, microelectromechanical, liquid-crystal, or thermal devices. At least one such device must be dedicated to each facet, and there must be at least one wire carrying a control or drive signal to the device. If a deformable mirror comprises many (e.g., thousands) of facets, then wiring becomes a major problem for design, and the problem is compounded in cases of piezoelectric or other actuators for which high drive voltages are required. In contrast, in optically driven mirrors, the wiring problem is eliminated. The basic principle of actuation of an optically driven deformable mirror is to use a laser beam to actuate a material. For example, a laser beam can be used to heat a material to make the material thermally expand to displace a mirror facet. In an experiment to demonstrate this principle, the actuator was a Golay cell having a diameter of approximately equal to 6 mm and a length of approximately equal to 10 mm. The beam from a laser diode was aimed at an absorber in the cell, thereby heating the gas in the cell. A mirror mounted on a 12.5-micron-thick polyethylene terephthalate diaphragm at one end of the cell became displaced as the gas expanded against the diaphragm. In one representative pair of experiments at a laser beam power of 0.23 W, the beam was mechanically chopped at frequencies of 1 and 5 Hz. The mirror exhibited corresponding oscillating displacements having amplitudes of 373 and 83 micron, respectively

Hemmati, Hamid↗

Larger-Stroke Piezoelectrically Actuated Microvalve

A proposed normally-closed microvalve would contain a piezoelectric bending actuator instead of a piezoelectric linear actuator like that of the microvalve described in the preceding article. Whereas the stroke of the linear actuator of the preceding article would be limited to approximately equal to 6 micrometers, the stroke of the proposed bending actuator would lie in the approximate range of 10 to 15 micrometers-large enough to enable the microvalve to handle a variety of liquids containing suspended particles having sizes up to 10 m. Such particulate-laden liquids occur in a variety of microfluidic systems, one example being a system that sorts cells or large biomolecules for analysis. In comparison with the linear actuator of the preceding article, the bending actuator would be smaller and less massive. The combination of increased stroke, smaller mass, and smaller volume would be obtained at the cost of decreased actuation force: The proposed actuator would generate a force in the approximate range of 1 to 4 N, the exact amount depending on operating conditions and details of design. This level of actuation force would be too low to enable the valve to handle a fluid at the high pressure level mentioned in the preceding article. The proposal encompasses two alternative designs one featuring a miniature piezoelectric bimorph actuator and one featuring a thick-film unimorph piezoelectric actuator (see figure). In either version, the valve would consume a power of only 0.01 W when actuated at a frequency of 100 Hz. Also, in either version, it would be necessary to attach a soft elastomeric sealing ring to the valve seat so that any particles that settle on the seat would be pushed deep into the elastomeric material to prevent or reduce leakage. The overall dimensions of the bimorph version would be 7 by 7 by 1 mm. The actuator in this version would generate a force of 1 N and a stroke of 10 m at an applied potential of 150 V. The actuation force would be sufficient to enable the valve to handle a fluid pressurized up to about 50 psi (approximately equal to 0.35 MPa). The overall dimensions of the unimorph version would be 2 by 2 by 0.5 mm. In this version, an electric field across the piezoelectric film on a diaphragm would cause the film to pull on, and thereby bend, the diaphragm. At an applied potential of 20 V, the actuator in this version would generate a stroke of 10 micrometers and a force of 0.01 N. This force level would be too low to enable handling of fluids at pressures comparable to those of the bimorph version. This version would be useful primarily in microfluidic and nanofluidic applications that involve extremely low differential pressures and in which there are requirements for extreme miniaturization of valves. Examples of such applications include liquid chromatography and sequencing of deoxyribonucleic acid.

Yang, Eui-Hyeok↗

Low-Cost, Rugged High-Vacuum System

A need exists for miniaturized, rugged, low-cost high-vacuum systems. Recent advances in sensor technology have led to the development of very small mass spectrometer detectors as well as other analytical instruments such as scanning electron microscopes. However, the vacuum systems to support these sensors remain large, heavy, and power-hungry. To meet this need, a miniaturized vacuum system was developed based on a very small, rugged, and inexpensive-to-manufacture molecular drag pump (MDP). The MDP is enabled by a miniature, very-high-speed (200,000 rpm), rugged, low-power, brushless DC motor optimized for wide temperature operation and long life. The key advantages of the pump are reduced cost and improved ruggedness compared to other mechanical hig-hvacuum pumps. The machining of the rotor and stators is very simple compared to that necessary to fabricate rotor and stator blades for other pump designs. Also, the symmetry of the rotor is such that dynamic balancing of the rotor will likely not be necessary. Finally, the number of parts in the unit is cut by nearly a factor of three over competing designs. The new pump forms the heart of a complete vacuum system optimized to support analytical instruments in terrestrial applications and on spacecraft and planetary landers. The MDP achieves high vacuum coupled to a ruggedized diaphragm rough pump. Instead of the relatively complicated rotor and stator blades used in turbomolecular pumps, the rotor in the MDP consists of a simple, smooth cylinder of aluminum. This will turn at approximately 200,000 rpm inside an outer stator housing. The pump stator comprises a cylindrical aluminum housing with one or more specially designed grooves that serve as flow channels. To minimize the length of the pump, the gas is forced down the flow channels of the outer stator to the base of the pump. The gas is then turned and pulled toward the top through a second set of channels cut into an inner stator housing that surrounds the motor. The compressed gas then flows down channels in the motor housing to the exhaust port of the pump. The exhaust port of the pump is connected to a commercially available diaphragm or scroll pump.

Sorensen, Paul↗

Reducing the Effect of Transducer Mount Induced Noise on Aeroacoustic Wind Tunnel Testing Data with a New Transducer Mount Design

Characterization of launch vehicle unsteady aerodynamics is a field best studied through experimentation, which is often carried out in the form of large scale wind tunnel testing. Measurement of the fluctuating pressures induced by the boundary layer noise is customarily made with miniature pressure transducers installed into a model of the vehicle of interest. Literature shows that noise level increases between two to five decibels (dB referenced to 20 micropascal) can be induced when the transducer surface is not mounted perfectly flush with the model outer surface. To reduce this artificially induced noise, special transducer holders have been used for aeroacoustic wind tunnel testing by NASA. This holder is a sleeve into which the transducer fits, with a cap that allows it to be mounted in a recessed hole in the model. A single hole in the holder allows the transport of the tunnel medium so the transducer can discriminate the fluctuating pressure due to the turbulent boundary layer noise. The holder is first dry fitted into the model and any difference in height between the holder and the model surface can be sanded flush. The holder is then removed from the model, the transducer glued inside the holder, and the holder replaced in the model, secured also with glue, thus eliminating the problem of noise level increases due to lack of flushness. In order to work with this holder design, special transducers have been ordered with their standard screen removed and the diaphragm moved as close to the top of the casing as possible to minimize any cavity volume. Although this greatly reduces induced noise due to the transducers being out of flush, the holders can also induce a cavity resonance that is usually at a very high frequency. This noise is termed transducer mount induced noise (XMIN). The peak of the mode can vary with the cavity depth, boundary layer noise that can excite the mode, tunnel flow medium, and the build of the transducers. Because the boundary layer flow interaction with the microphone holder seems to have some effect on the cavity resonance response, the NASA/Marshall Space Flight Center (MSFC) aeroacoustic team postulated that changing the design of the holder might reduce the cavity resonance response. An experiment was performed at the MSFC Trisonic Wind Tunnel comparing a new holder design with the traditional MSFC holder. The new holder design is intended to mimic the Kulite Semiconductors, Inc. B-screen, where the single hole of the traditional MSFC holder is replaced by a series of ten 0.007 inch diameter holes. This particular design serves to protect the transducer diaphragm as in the manufacturer's B-screen, but also increases the frequency of the XMIN such that it is not apparent in the data collected from aeroacoustic wind tunnel tests. MSFC compared the two holder designs by installing two transducers in standard holders on one side of a ten inch long ten degree cone, and two transducers in B-screen holders on the opposite side for a series of runs at different conditions. Over 11-13 February, 2013, the model was run at Mach numbers between 0.80 and 1.96 at angles of attack at 0 deg, plus or minus 1 deg, plus or minus 2 deg, plus or minus 4 deg, and plus or minus 8 deg. Model roll attitudes at 0 deg, 90 deg, and 180 deg were tested to isolate potential tunnel bias. This paper presents results from the test showing that the proposed holder design significantly reduces the influence of XMIN on measured fluctuating pressure levels.

Herron, A. J.↗

Feature Detection and Curve Fitting Using Fast Walsh Transforms for Shock Tracking: Applications

Walsh functions form an orthonormal basis set consisting of square waves. Square waves make the system well suited for detecting and representing functions with discontinuities. Given a uniform distribution of 2p cells on a one-dimensional element, it has been proven that the inner product of the Walsh Root function for group p with every polynomial of degree < or = (p - 1) across the element is identically zero. It has also been proven that the magnitude and location of a discontinuous jump, as represented by a Heaviside function, are explicitly identified by its Fast Walsh Transform (FWT) coefficients. These two proofs enable an algorithm that quickly provides a Weighted Least Squares fit to distributions across the element that include a discontinuity. The detection of a discontinuity enables analytic relations to locally describe its evolution and provide increased accuracy. Time accurate examples are provided for advection, Burgers equation, and Riemann problems (diaphragm burst) in closed tubes and de Laval nozzles. New algorithms to detect up to two C0 and/or C1 discontinuities within a single element are developed for application to the Riemann problem, in which a contact discontinuity and shock wave form after the diaphragm bursts.

Gnoffo, Peter A.↗

Liquid propulsion systems

Bladder and expulsion devices for spacecraft liquid propulsion systems - pinhole leak test fixture, heat sterilization of ethylene propylene with hydrazine, and metal diaphragms

PROPYLENE↗

Rapid helium-air analyzer can measure other binary gas mixtures

Instrument comprised of an ionization pressure gage and a diaphragm pressure gage consisting of strain gages to make a four-arm bridge, and a ratiometer is constructed for analyzing gas mixtures. The ratio of the outputs of the two gages is proportional to the mixture composition.

Melfi, L. T.↗

A Preliminary Theoretical Study of the Expansion Tube, a New Device for Producing High-Enthalpy Short-Duration Hypersonic Gas Flows

A preliminary theoretical study was conducted of a new technique for producing high-enthalpy gas flows. The device considered utilizes an unsteady expansion process for the purpose of total-enthalpy multiplication. Analyses were conducted for both perfect and real air in equilibrium, assuming idealized diaphragm bursts, centered expansion waves, and continuum flow. Results of the study showed the expansion tube capable of outperforming the conventional shock tunnel by a factor of approximately 2 in velocity for the same test-section ambient density and pressure. The degree of dissociation is low at all phases of the thermodynamic cycle in the expansion tube; thus the test-section air has a good possibility of being in equilibrium. Maximum pressures involved in the cycle for duplicating a typical reentry from, a lunar mission are low enough for existing pressure-vessel techniques. Both the known and anticipated advantages and disadvantages of this new concept are also discussed.

TUBING↗

Pressure transducer 3/8-inch in size can be faired into surface

To measure fluid pressure with minimum disturbance to fluid flow, a miniature pressure transducer can be imbedded and faired into the test surface. Incorporated in the design are piezoresistive elements mounted on a diaphragm, which transform pressure strains into an electrical signal.

Schaffer, R. J.↗

One-shot valve may be remotely actuated

One-shot valve, with spring-loaded plunger and sealing diaphragm, incorporates an emergency release actuated by a remote sensor. The plunger is released by the electrical melting of a fuse link and pierces the valve seal. The valve lowers fluid pressure in a container without losing the contained fluid.

Kami, S.↗