Search NASA⌕ Search

SEARCH · Search NASA

Results for “DOME”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Using virtual environment technology for preadapting astronauts to the novel sensory conditions of microgravity

A unique training device is being developed at the Johnson Space Center Neurosciences Laboratory to help reduce or eliminate Space Motion Sickness (SMS) and spatial orientation disturbances that occur during spaceflight. The Device for Orientation and Motion Environments Preflight Adaptation Trainer (DOME PAT) uses virtual reality technology to simulate some sensory rearrangements experienced by astronauts in microgravity. By exposing a crew member to this novel environment preflight, it is expected that he/she will become partially adapted, and thereby suffer fewer symptoms inflight. The DOME PAT is a 3.7 m spherical dome, within which a 170 by 100 deg field of view computer-generated visual database is projected. The visual database currently in use depicts the interior of a Shuttle spacelab. The trainee uses a six degree-of-freedom, isometric force hand controller to navigate through the virtual environment. Alternatively, the trainee can be 'moved' about within the virtual environment by the instructor, or can look about within the environment by wearing a restraint that controls scene motion in response to head movements. The computer system is comprised of four personal computers that provide the real time control and user interface, and two Silicon Graphics computers that generate the graphical images. The image generator computers use custom algorithms to compensate for spherical image distortion, while maintaining a video update rate of 30 Hz. The DOME PAT is the first such system known to employ virtual reality technology to reduce the untoward effects of the sensory rearrangement associated with exposure to microgravity, and it does so in a very cost-effective manner.

Duncan, K. M.↗

Volcanic Constructs on Ganymede and Enceladus: Topographic Evidence from Stereo Images and Photoclinometry

The morphology of volcanic features on Ganymede differs significantly from that on the terrestrial planets. Few if any major volcanic landforms, such as thick flows or shield volcanoes, have been identified to date. Using new stereo Voyager images, we have searched Ganymede for relief-generating volcanic constructs. We observed seven major types of volcanic structures, including several not previously recognized. The oldest are broad flat-topped domes partially filling many older craters in dark terrain. Similar domes occur on Enceladus. Together with smooth dark deposits, these domes indicate that the volcanic history of the dark terrain is complex. Bright terrain covers vast areas, although the style of emplacement remains unclear. Smooth bright materials embay and flood older terrains, and may have been emplaced as low- viscosity fluids. Associated with smooth bright material are a number of scalloped-shaped, semi- enclosed scarps that cut into preexisting terrain. In planform these structures resemble terrestrial calderas. The youngest volcanic materials identified are a series of small flows that may have flooded the floor of the multiring impact structure Gilgamesh, forming a broad dome, The identification of volcanic constructs up to I km thick is the first evidence for extrusion of moderate-to-high viscosity material on Ganymede. Viscosity and yield strength estimates for these materials span several orders of magnitude, indicating that volcanic materials on Ganymede have a range of compositions and/or were extruded under a wide range of conditions and/or eruptive styles.

Schenk, Paul M.↗

Ferroelectric Fluid Flow Control Valve

An active valve is controlled and driven by external electrical actuation of a ferroelectric actuator to provide for improved passage of the fluid during certain time periods and to provide positive closure of the valve during other time periods. The valve provides improved passage in the direction of flow and positive closure in the direction against the flow. The actuator is a dome shaped internally prestressed ferroelectric actuator having a curvature, said dome shaped actuator having a rim and an apex. and a dome height measured from a plane through said rim said apex that varies with an electric voltage applied between an inside and an outside surface of said dome shaped actuator.

Jalink, Antony, Jr.↗

Stereo Topography of the South Polar of Mar: Volatile Inventory and Mars Polar Landing Landing Site

Viking stereo images and topographic maps reveal that the south polar layered deposits of Mars are topographically complex and morphologically distinct from the north polar layered deposits. The dominant feature is a 500-km-wide topographic dome that rises 3 km above the surrounding plains. This dome underlies the residual ice cap but is at least 50% larger in area. Erosional scarps and terraces indicate that this dome was once more extensive and has undergone erosional retreat. Adjacent to the dome, layered deposits form a vast plateau 1-1.5 km high extending approximately 1000 km beyond and to one side of the residual south polar cap. This plateau is relatively flat at kilometer scales, although it is cut in places by troughs and depressions, which have locally steep scarps up to 2 km high and sloping up to roughly 10 deg. Contiguously flat kilometer-scale regions the size of the Mars Polar Lander (MPL) landing ellipse are present. These are in the form of plateaus 100-300 km wide and 1-2 km high. One of the largest of these plateaus has been proposed as a landing site for the Mars Polar Lander (MPL). The volume associated with the south polar layered deposits may be comparable to those of the layered deposits at the north pole. Although this doubles the current probable inventory of surface ice on Mars, it still falls far short of accounting for the inferred volume of water on Mars in the past.

Schenk, Paul M.↗

Experimental Results on the Feasibility of an Aerospike for Hypersonic Missiles

A series of wind tunnel tests have been performed on an aerospike-protected missile dome at a Mach number of 6 to obtain quantitative surface pressure and temperature-rise data, as well as qualitative flow visualization data. These data were used to determine aerospike concept feasibility and will also provide a database to be used for calibration of computational fluid dynamics codes. Data were obtained on the hemispherical missile dome with and without an aerospike that protrudes ahead of the dome along the axisymmetric center line. Data were obtained on two models (one pressure, one temperature) in the NASA Langley 20-Inch Mach 6 Tunnel at a freestream Reynolds number of 8.0 x 10(exp 6) per feet and angles of attack from 0 to 40 degrees. Surface pressure and temperature-rise results indicate that the aerospike is effective for very low angles of attack (less than 5 degrees) at Mach 6. Above 5 degrees, impingement of the aerospike bow shock and the flow separation shock from the recirculation region created by the aerospike causes pressure and temperature increases on the windward side of the dome which exceed values observed in the same region with the aerospike removed. Flow characterization obtained via oil-flow and schlieren photographs provides some insight into the quantitative surface data results, including vortical flow and shock-wave impingement.

Huebner, Lawrence D.↗

Structural Analysis of Helios Filament-Wound Tanks Subjected to Internal Pressure and Cooling

A finite-element stress analysis is performed on Helios filament-wound hydrogen tanks to examine the stress field and effect of end dome geometry on the stress field. Each tank is composed of a central circular cylindrical section with either geodesic or hemispherical end domes, which have metallic polar bosses. The tanks are subjected to combined and separate internal pressure and temperature loading conditions, and the stress contributions of each loading component are examined. The tank-wall-polar-boss interfacial meridional tensile stress in the hemispherical dome is found to be approximately 27 percent lower than that in the geodesic dome. The effects of both material anisotropy and the aluminum lining on the intensities of tensile meridional stress at the tank-wall-polar-boss bonding interface are examined.

Ko, William L↗

Monitoring Eruptive Activity at Mount St. Helens with TIR Image Data

Thermal infrared (TIR) data from the MASTER airborne imaging spectrometer were acquired over Mount St. Helens in Sept and Oct, 2004, before and after the onset of recent eruptive activity. Pre-eruption data showed no measurable increase in surface temperatures before the first phreatic eruption on Oct 1. MASTER data acquired during the initial eruptive episode on Oct 14 showed maximum temperatures of similar to approximately 330 C and TIR data acquired concurrently from a Forward Looking Infrared (FLIR) camera showed maximum temperatures similar to approximately 675 C, in narrow (approximately 1-m) fractures of molten rock on a new resurgent dome. MASTER and FLIR thermal flux calculations indicated a radiative cooling rate of approximately 714 J/m(exp 2)/s over the new dome, corresponding to a radiant power of approximately 24 MW. MASTER data indicated the new dome was dacitic in composition, and digital elevation data derived from LIDAR acquired concurrently with MASTER showed that the dome growth correlated with the areas of elevated temperatures. Low SO2 concentrations in the plume combined with sub-optimal viewing conditions prohibited quantitative measurement of plume SO2. The results demonstrate that airborne TIR data can provide information on the temperature of both the surface and plume and the composition of new lava during eruptive episodes. Given sufficient resources, the airborne instrumentation could be deployed rapidly to a newly-awakening volcano and provide a means for remote volcano monitoring.

thermal emissions↗

NDE for the ARES I Upper Stage Common Bulkhead

The current design of the ARES 1 Upper Stage uses a common bulkhead to separate the liquid hydrogen and liquid oxygen tanks. The bulkhead consists of aluminum face sheets bonded to a Phenolic honeycomb core. The face sheets, or domes, are friction stir welded to Y-rings that connect the bulkhead to the barrel sections of the liquid hydrogen and liquid oxygen tanks. Load between the Y-rings is carried by an externally attached bolting ring. The development of nondestructive evaluation methods for the ARES I Upper Stage Common Bulkhead are outlined in this presentation. Methods for inspecting the various components of the bulkhead are covered focusing in on the dome skins, core-to-dome bond lines and friction stir welds as well as structural details like the fastener holes. Thermography, shearography and ultrasonic methods are discussed for the bond lines. Eddy current methods are discussed for the fastener holes and dome skins. A combination of phased array ultrasound, liquid penetrant and radiography are to being investigated for use on the friction stir welds. Keywords: Composite materials, NDE, Cryogenic structures

Walker, James↗

Solar Rejection Filter for Large Telescopes

To reject solar radiation photons at the front aperture for large telescopes, a mosaic of large transmission mode filters is placed in front of the telescope or at the aperture of the dome. Filtering options for effective rejection of sunlight include a smaller filter down-path near the focus of the telescope, and a large-diameter filter located in the front of the main aperture. Two types of large filters are viable: reflectance mode and transmittance mode. In the case of reflectance mode, a dielectric coating on a suitable substrate (e.g. a low-thermal-expansion glass) is arranged to reflect only a single, narrow wavelength and to efficiently transmit all other wavelengths. These coatings are commonly referred to as notch filter. In this case, the large mirror located in front of the telescope aperture reflects the received (signal and background) light into the telescope. In the case of transmittance mode, a dielectric coating on a suitable substrate (glass, sapphire, clear plastic, membrane, and the like) is arranged to transmit only a single wavelength and to reject all other wavelengths (visible and near IR) of light. The substrate of the large filter will determine its mass. At first glance, a large optical filter with a diameter of up to 10 m, located in front of the main aperture, would require a significant thickness to avoid sagging. However, a segmented filter supported by a structurally rugged grid can support smaller filters. The obscuration introduced by the grid is minimal because the total area can be made insignificant. This configuration can be detrimental to a diffraction- limited telescope due to diffraction effects at the edges of each sub-panel. However, no discernable degradation would result for a 20 diffraction-limit telescope (a photon bucket). Even the small amount of sagging in each subpanel should have minimal effect in the performance of a non-diffraction limited telescope because the part has no appreciable optical power. If the front aperture filter is integrated with the telescope dome, it will reject heat from the dome and will significantly reduce dome temperature regulation requirements and costs. Also, the filter will protect the telescope optics from dust and other contaminants in the atmosphere. It will be simpler to clean or replace this filter than the telescope primary mirror. It may be necessary to paint the support grid with a highly reflective material to avoid overheating.

Hemmati, Hamid↗

A Second Generation Swirl-Venturi Lean Direct Injection Combustion Concept

A low-NO (sub x) aircraft gas turbine engine combustion concept was developed and tested. The concept is a second generation swirl-venturi lean direct injection (SV-LDI) concept. LDI is a lean-burn combustion concept in which the fuel is injected directly into the flame zone. Three second generation SV-LDI configurations were developed. All three were based on the baseline 9-point SV-LDI configuration reported previously. These second generation configurations had better low power operability than the baseline 9-point configuration. Two of these second generation configurations were tested in a NASA Glenn Research Center flametube; these two configurations are called the at dome and 5-recess configurations. Results show that the 5-recess configuration generally had lower NO (sub x) emissions than the flat dome configuration. Correlation equations were developed for the flat dome configuration so that the landing-takeoff NO (sub x) emissions could be estimated. The flat dome landing-takeoff NO (sub x) is estimated to be 87-88 percent below the CAEP/6 standards, exceeding the ERA project goal of 75 percent reduction.

Tacina, Kathleen M.↗

A Comparison of Three Second-generation Swirl-Venturi Lean Direct Injection Combustor Concepts

Three variations of a low emissions aircraft gas turbine engine combustion concept were developed and tested. The concept is a second generation swirl-venturi lean direct injection (SV-LDI) concept. LDI is a lean-burn combustion concept in which the fuel is injected directly into the flame zone. All three variations were based on the baseline 9- point SV-LDI configuration reported previously. The three second generation SV-LDI variations are called the 5-recess configuration, the flat dome configuration, and the 9- recess configuration. These three configurations were tested in a NASA Glenn Research Center medium pressure flametube. All three second generation variations had better low power operability than the baseline 9-point configuration. All three configurations had low NO(sub x) emissions, with the 5-recess configuration generally having slightly lower NO(x) than the flat dome or 9-recess configurations. Due to the limitations of the flametube that prevented testing at pressures above 20 atm, correlation equations were developed for the at dome and 9-recess configurations so that the landing-takeoff NO(sub x) emissions could be estimated. The flat dome and 9-recess landing-takeoff NO(x) emissions are estimated to be 81-88% below the CAEP/6 standards, exceeding the project goal of 75% reduction.

combustor↗

Summary of Testing Results for the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER)

Testing was completed on the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER) between August 2019 and January 2020. SHIIVER was designed to be a test bed for the scaling of cryogenic fluid management technologies as applied to large upper stages and long duration in-space stages. The baseline SHIIVER design consists of uninsulated structural skirts attached to a propellant tank insulated with polyurethane Spray-On Foam Insulation (SOFI). The initial testing of the SHIIVER hardware was with liquid hydrogen and sought to demonstrate the use of boil-off vapor to intercept heat on a structural skirt, multilayer insulation (MLI) on the tank domes, and the radio frequency mass gauge (RFMG). Testing was completed in four stages: a baseline thermal vacuum test prior to installation of the MLI on the tank domes, a thermal vacuum test after the MLI installation, a reverberant acoustic test, and a subsequent thermal vacuum test to verify that no damage occurred during the reverberant acoustic testing. Each thermal vacuum test with chamber wall at ambient temperature and vacuum level in the 10-6 torr range was conducted continuously between approximately 90% full and 25% full. Test results showed that the vapor cooling reduced the heat load to the tank by approximately 10%, but the boil-off by less than 3% at 50% full, with and without MLI installed on the domes. The MLI installed on the domes reduced the heat load to the tank by approximately 40% at all fill levels, but the boil-off by approximately 25% at 90% full and 45% below 65% full. The RFMG performed well over all fill ranges, and several RF tank modes were used to gauge the mass of fluid in the tank. SHIIVER was then exposed to an acoustic environment of 147 dB OASPL (overall sound pressure level) in a reverberant chamber. The acoustic environment envelopes the upper stage internal acoustic level of several different modern launch vehicles. No structural or thermal performance changes were observed after exposure to the acoustic environment. Final thermal vacuum testing after the acoustic testing showed no degradation to the MLI due to the acoustic environment as measured via system heat loads

SHIIVER↗

Hybrid Thermally Efficient Core (HyTEC) HyTEC Phase 1 – Combustor Final Report

The objective of the HyTEC – Combustor Technology project is to develop technology for a compact, low emissions, rich-burn combustor that maintains a high-level of durability. To accomplish this, the combustor will incorporate CMC liners and a CMC Dome to enable improved air utilization for mixing and NOx reduction. In particular, three technology areas were matured: metallic swirler attachment to the CMC dome, Nickel diffusion in CMC, and EBC advancements with improved durability. The maturation of these technology areas is critical to successfully designing a combustor for an engine intended to demonstrate increased thermal efficiency with integrated high-power density-core engine technologies. As part of the project, multiple swirler attachment architectures were matured through the design process, manufactured, and tested in simulated engine conditions. These architectures utilized two different approaches to attachment: a pressure loaded approach and a clamped approach. Each approach required testing at simulated engine conditions to mature the technology. These tests were developed to ensure that the probable failure mechanisms for each architecture were assessed relative to its long-term durability. After successfully testing both approaches, the pressure loaded approach was chosen based on its simplicity and its similarity to the attachment approach used on lean burn combustors. Finally, this successful testing resulted in the swirler attachment technology achieving TRL 4 status. Another aspect of concern with the metallic swirler attachment is the potential for nickel diffusion into the CMC to cause durability shortfalls. A series of tests were completed to understand both the amount of nickel that is expected to diffuse into the CMC and the effect this diffusion will have on mechanical properties of the CMC. After successfully completing this testing, the reduction in local mechanical properties was found to not have an impact on the overall durability of the CMC Dome. To further improve the overall durability, three different EBC coating architectures were also studied. One of these coatings being the current state of the art for CMC liners with the other two being proposed improvements. Coupons were produced using each coating and subjected to a series of laboratory testing. One coating was found to have an overall superior durability in laboratory testing and survived rig testing without indication of degradation. This successful testing resulted in the EBC technology achieving TRL 5 status. Overall, a design approach was successfully down-selected that achieves both the TPM requirements and the need for TRL 4+ status. This design incorporates a pressure loaded swirler attachment with an improved EBC coating (Architecture 1). This combination allows the continued use of a CMC dome and results in an improved durability for the proposed compact core combustor.

CMC↗

Measuring Local Turbulence Along the Optical Path: Multi-Beam Optical Seeing Sensor

Deflection of light along the optical path is a major source of image degradation for ground-based telescopes. Methods have been developed to measure upper atmospheric seeing based on models of the turbulence in the atmosphere, but due to boundary conditions, transmission within telescope enclosures is more complex. The Multi-beam Optical Seeing Sensor (MOSS) directly measures the component of the image quality degradation from inhomogeneity of the index of refraction within the telescope dome. MOSS outputs four near-parallel beams of light that travel along the optical path and are imaged by the telescope’s detector, landing like starlight on the telescope’s focal plane. By using a strobed light source, we can ‘freeze’ the instantaneous index variations transverse to the optical path. This system captures both ‘dome’ and ‘mirror’ seeing. Through plotting the standard deviation of differential motion between pairs of beams, MOSS enables characterization of the length scale of turbulence within the dome. The temporal coherence of temperature gradients can be probed with different pulse lengths, and the spatial coherence by comparing pairs at different separations across the aperture of the telescope. Optical path turbulence measurements, alongside other telemetry metrics, will guide thermal and airflow management to optimize image quality. A MOSS prototype was installed in the 1.2[Formula: see text]m Auxiliary Telescope (AuxTel) at the Vera C. Rubin Observatory in Chile, and preliminary data constrain the optical path turbulence with a lower bound of 1.4 arcsec. The optical path turbulence varied throughout the night of observing.

Astronomical seeing↗

Normalization Method and Application for MODIS TEB Assessments using Earth Scene Measurements

Selected Earth targets are commonly used for satellite sensor calibration assessments (e.g. sensor stability and inter-comparisons). Moreover, typical scenes used for the calibration assessment of the thermal emissive bands (TEBs) includeDome Concordia (Dome-C), ocean, desert, and deep convective clouds (DCC). Reference data used for these calibration assessments can come from another band, another instrument, or ground measurements. The Dome-C site, covered with uniformly-distributed permanent snow, is normally used for the assessment of the TEBsat cold temperatures. Furthermore, ocean and desert measurements prove useful for scenes with higher temperatures. The DCC, one of the most consistent and coldest targets, can be used for the TEBs calibration and product stability assessments. MODIS band 31 (~ 11 m) can be used as a reference for these scenes. However, measurements over these scenes have seasonal variations, and the DCC brightness temperatures (BTs) have asymmetrical distributions. These features can introduce additional uncertainty to the stability assessments. A normalization method is applied by using an empirical model to derive reference-dependent BTs. Using the developed empirical model, measurements can be normalized to a reference BT in order to enhance the calibration assessment’s accuracy. This method is evaluated using all four scene types (i.e. ocean, desert, snow (Dome-C), and DCC) and applied to all the Terra and Aqua MODIS TEBs. Stability assessments over the instruments’ entire data records are presented and discussed. The technique can be applied in future efforts to support MODIS TEBs calibration assessments.

MODIS TEB↗

Coaxial Direct Ink Writing of Cholesteric Liquid Crystal Elastomers in 3D Architectures

Abstract Cholesteric liquid crystal elastomers (CLCEs) hold great promise for mechanochromic applications in anti‐counterfeiting, smart textiles, and soft robotics, thanks to the structural color and elasticity. While CLCEs are printed via direct ink writing (DIW) to fabricate free‐standing films, complex 3D structures are not fabricated due to the opposing rheological properties necessary for cholesteric alignment and multilayer stacking. Here, 3D CLCE structures are realized by utilizing coaxial DIW to print a CLC ink within a silicone ink. By tailoring the ink compositions, and thus, the rheological properties, the cholesteric phase rapidly forms without an annealing step, while the silicone shell provides encapsulation and support to the CLCE core, allowing for layer‐by‐layer printing of self‐supported 3D structures. As a demonstration, free‐standing bistable thin‐shell domes are printed. Color changes due to compressive and tensile stresses can be witnessed from the top and bottom of the inverted domes, respectively. When the domes are arranged in an array and inverted, they can snap back to their base state by uniaxial stretching, thereby functioning as mechanical sensors with memory. The additive manufacturing platform enables the rapid fabrication of 3D mechanochromic sensors thereby expanding the realm of potential applications for CLCEs.

36 MATERIALS SCIENCE↗

Characterization of runaway electron impact on instrumented sacrificial limiters on DIII-D

Instrumented sacrificial limiter heads, both domed (proud) and flat (flush) are used in DIII-D runaway electron (RE) wall strikes to study the wall impact dynamics with high spatial and time resolution. The approximate structure of the RE wetted area and heating depth on the domed limiter heads were predicted qualitatively using orbit-tracking simulations, although a strong left–right asymmetry (about the magnetic field direction) was not captured well by the simulations. It is hypothesized that this difference is perhaps due to the local 3D magnetic field perturbation of the dome limiter head. The average kinetic energy K and pitch angle θ of REs striking the limiter head were estimated from the spatial distribution of local HXR emission and were estimated to be roughly K ≈ 4 MeV and θ ≈ 0.2 rad. These values are roughly consistent with in-plasma values estimated before the loss event, indicating that RE kinetic energy and pitch angle are not drastically altered when transporting to the wall. Large shot–shot variations (1–10 kJ) in energy deposition into the limiter head were observed and were explained by shot–shot variations in locked magneto-hydrodynamics mode toroidal phase. For the largest deposited energies (10 kJ), graphite material failure and explosive dust release was observed, and the depth of material failure at higher energy deposition was successfully reproduced using modelling of volumetric energy deposition and brittle failure. The presence of energetic (keV) level ion impact during the RE wall strike was confirmed by three different surface analysis techniques. The ratio of energetic ion to RE flux appears to be larger on flat surfaces within the RE wetted area, although the energetic ion flux and total energy flux due to energetic ions have not yet been quantified.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cathodic Protection Modeling for Hanford Underground Double-Shell Tank Farms

Hanford stores millions of gallons of radioactive and chemically hazardous waste from the production of weapon materials in tank farms consisting of underground carbon-steel storage tanks surrounded by reinforced concrete. Six of these Hanford tank farms use double-shell storage tanks (DSTs). The DST farms were constructed from 1968 to 1986 with a planned 40–50 year design life, so some are already operating beyond their initial life expectancy. Ultrasonic testing (UT) has indicated significant thinning on the bottom of the secondary (outer) liner of these tanks, believed to arise from groundwater intrusion driving concrete side corrosion. There is no direct access to the steel/concrete interface between the tank and the concrete pad, making it difficult to apply a chemical-based mitigation strategy or to conduct repairs, but cathodic protection (CP) is a possible method to inhibit further concrete-side corrosion. Hanford already uses CP to protect below grade steel piping within the tank farms and connected to the tanks, but this system was not designed to protect the tank bottoms. CP design must account for the structures surrounding the DSTs, including the steel reinforcing bars (rebar) within the concrete pad and vault, various process lines, and the existing CP system. In this study, finite element analysis (FEA) modeling was carried out to simulate CP protection of 1) a single tank and CP anode to develop options for modeling the rebar and to compare to a simpler circuit model and 2) the entire Hanford AN tank farm as a representative example consisting of seven tanks, associated piping, and both existing and new CP anodes. Both circuit and FEA models predict that significant protective current could be delivered to the bottoms of the tanks with the addition of tank-protection anodes below the depth of the tanks. Simulations with only the existing pipe-protection anodes active confirmed that only a very small current to the tank bottoms is predicted under present conditions. Multiple simplified representations of the dome and wall rebar were tested to reduce the computational complexity of the tank-farm simulations, resulting in modeling the rebar as edge elements with a prescribed effective circumference that matches the real rebar surface area. The geometry of the rebar is also simplified into horizontal hoops around the tank walls and radial rebar over the dome with increased effective circumference to retain the target surface area. This simplification was found to greatly reduce the complexity and solution time of the models without large changes in current distributions, especially to the tank bottom. A range of values were tested for model parameters such as soil and concrete resistivities and polarization resistance to investigate their impact on the current and electric potential distributions. Depending on the parameters used, FEA simulations predict some risk of overprotection, particularly on the piping system; since overprotection can also lead to surface damage associated with hydrogen gas generation at the interface (e.g. hydrogen embrittlement or damage to coatings), this needs to be considered when refining the design of the new CP system. Comparison between the FEA models and the circuit model representation demonstrated that the circuit model could not match the predicted FEA current distribution, even when using the exact same surface areas. This discrepancy appeared to be at least partly attributable to the impact of the relative positions of the tank components and anodes to each other and to the ground surface. The FEA model accounts for the relative positions since it solves the governing equations in three dimensions, but the circuit model cannot account for the positioning. In particular, the circuit model underpredicts the current to the tank bottom and overpredicts the current to the dome compared to FEA for the baseline geometry. The FEA models omitted the electrically isolated rebar in the bottom concrete slab. However, a circuit based stray current model estimated that only 2.1% of the total current through the slab would stray into the rebar, corresponding to ~0.21 A for a target current density of 2 mA/ft2 to the tank bottom. The estimated corrosion driven by this amount of stray current is predicted to yield a lifetime of >400 years for the minimum rebar diameter, assuming an acceptable cross-section area loss of 10%.

d'Entremont, Anna [Savannah River National Laborat↗