Search NASA⌕ Search

SEARCH · Search NASA

Results for “DRY HEAT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Initial Assessment of CTF for Time-at-Temperature Applications

The US nuclear industry is interested in improving the economics of their fleet of light-water reactors (LWRs) by uprating US plants. One option being considered is to regain lost margin from overly conservative fuel safety limits. The current limit requires avoidance of critical heat flux (CHF) and prevents further operation of fuel that experiences a dry-out in boiling water reactors (BWRs) or departure from nucleate boiling (DNB) in pressurized water reactors (PWRs); however, it has been shown that temporary, mild dry-out of the fuel does not necessarily increase the risk of fuel failure during its normal anticipated operating life. Such mild dry-out or DNB events may occur during a plant anticipated operational occurrence (AOO), such as a locked rotor in a PWR or a pump trip in a BWR. The time-at-temperature (TAT) approach to regulating fuel operation aims to demonstrate that the fuel rod’s integrity is not challenged during such a mild transient that leads to CHF in which the fuel operates at an elevated temperature for a brief period of time. However, implementing this approach will require extensive fuel material experimental data, as well as supporting modeling and simulation (M&S) predictions, to ensure that the predicted fuel response during AOOs, with all applicable uncertainty considered, will not threaten the safety of the fuel during the transient or the remainder of its anticipated lifecycle. To address this need, a comprehensive effort is being proposed that includes generating cladding material data under TAT conditions, assessment of available code capabilities for TAT conditions, development of new mechanistic models, and demonstration of the M&S capabilities for AOOs of interest. This will require a joint effort between the Nuclear Energy Advanced Modeling and Simulation (NEAMS) and Advanced Fuels Campaign (AFC) programs, as well as close collaboration with nuclear industry stakeholders. The outcome of this collaboration will result in development and assessment of capabilities that can be used by the nuclear industry to support qualification of a TAT-based fuel failure criteria safety limit. This report focuses on the thermal hydraulics (T/H) modeling capabilities and summarizes currently available data for validating the T/H subchannel code CTF for TAT conditions, as well as preliminary assessment results of the code. The initial assessment also resulted in implementation of an alternative post-CHF heat transfer package, which has been shown to significantly improve accuracy. This report is not a final assessment and does not consider all available validation data; it is intended that a future assessment will more fully validate the code for this application.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Process for the Recovery of Actinide and Lanthanide Oxides via Thermal Decomposition and Calcination of Loaded Diglycolamide Resin

Diglycolamide (DGA) resin, a product produced by Eichrom Technologies, Inc. employs TODGA (N,N,N',N'-tetraoctyldiglycolamide) as the active extractant, which will be used by Savannah River National Laboratory to extract trivalent actinides and lanthanides from dissolved irradiated Mark-18A targets. The final form of the extracted material will be an oxide suitable for shipment. A two-step process was developed and validated for the direct recovery of actinides and lanthanides loaded on I-grade DGA resin as nitrates by thermally drying and decomposing resin loaded with Nd(III), a surrogate for trivalent actinides and lanthanides, under inert conditions followed by calcining the resultant residue in air to provide an oxide product. Further, a stepwise heating profile up to 385°C under argon gas flow resulted in 85% to 89% mass loss during the resin drying and decomposition step, and calcination of the resultant Nd-loaded resin residue provided an overall material mass loss of ≥ 98%. Recoveries from resin saturated with Nd(III) from 7 M and 0.35 M nitric acid subjected to this process were 30.7 mg and 27.6 mg Nd/g dry resin, respectively, representing an average of 96.1% of Nd retained in the resin bed.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Fatigue Test Result for High Burnup Pressurized Water Reactor Rods

The High Burnup Spent Fuel Data Project, sponsored by DOE-NE, is focused on understanding the effects of long-term storage and transportation on high burnup (HBU) (>45 gigawatt days per metric ton uranium) light water reactor fuel. The experiment includes 32 HBU spent nuclear fuel (SNF) assemblies that will be stored in a typical Independent Spent Fuel Storage Installation (ISFSI) and 25 sister rods - nine SNF rods that were removed from the fuel assemblies prior to insertion to the ISFSI and 16 SNF rods removed from similar HBU assemblies. The sister rods provide a baseline of the condition of the HBU rods prior to loading, drying, and long-term dry storage. Destructive examinations of the sister rods are focused on understanding overall SNF rod strength and durability. Both composite fuel and empty cladding will be tested to derive material properties. While the data generated can be used for multiple purposes, a primary goal of the sister rod PIE data and associated measured mechanical properties is to support existing fuel storage licensing and relicensing activities by addressing identified knowledge gaps, and enhance the technical basis for post-storage transportation, handling, and consolidation activities. Fatigue tests of HBU M5-clad, ZIRLO-clad, Zircaloy-4, and low tin Zircaloy-4 segments have been completed using ORNL’s Cyclic Integral Reversible Fatigue Tester (CIRFT). This is the first time ZIRLO-clad rods have been tested. Some of the segments were heat-treated to understand the effects of thermal transients such as those encountered during dry storage vacuum drying on the fatigue lifetime. This paper presents results of the fatigue tests obtained to date and discusses planned future tests.

Montgomery, Rose↗

Impact of size and thermal gradient on supercooling of phase change materials for thermal energy storage

Phase change material based thermal energy storage has many current and potential applications in the heating and cooling of buildings, battery and electronics thermal management, thermal textiles, and dry cooling of power plants. However, connecting lab scale thermal data obtained with differential scanning calorimetry (DSC) to the performance of large-scale practical systems has been a major challenge primarily due to the dependence of supercooling on the size and temperature gradient of the system. Here we show how a phase change material’s supercooling behavior can be characterized experimentally using common lab scale thermal analysis techniques. We then develop a statistics based theoretical model that uses the lab-scale data on small samples to quantitatively predict the supercooling performance for a general thermal energy storage application of any size, including also allowing for the possibility of temperature gradients. Finally, we validate the modeling methodology by comparing to experimental results for solid-solid phase change in neopentyl glycol, which shows how the model successfully predicts the changes in supercooling temperature across a large range of cooling rates (2 orders of magnitude) and volumes (3 orders of magnitude). By accounting for thermal gradients, the model avoids ~2x error incurred by lumped approximations.

36 MATERIALS SCIENCE↗

Can N95 Respirators Be Reused after Disinfection? How Many Times?

The coronavirus disease 2019 (COVID-19) pandemic has led to a major shortage of N95 respirators, which are essential for protecting healthcare professionals and the general public who may come into contact with the virus. Thus, it is essential to determine how we can reuse respirators and other personal protective equipment in these urgent times. We investigated multiple commonly used disinfection schemes on media with particle filtration efficiency of 95%. Heating was recently found to inactivate the virus in solution within 5 min at 70 °C and is among the most scalable, user-friendly methods for viral disinfection. We found that heat (≤85 °C) under various humidities (≤100% relative humidity, RH) was the most promising, nondestructive method for the preservation of filtration properties in meltblown fabrics as well as N95-grade respirators. At 85 °C, 30% RH, we were able to perform 50 cycles of heat treatment without significant changes in the filtration efficiency. At low humidity or dry conditions, temperatures up to 100 °C were not found to alter the filtration efficiency significantly within 20 cycles of treatment. Ultraviolet (UV) irradiation was a secondary choice, which was able to withstand 10 cycles of treatment and showed small degradation by 20 cycles. However, UV can potentially impact the material strength and subsequent sealing of respirators. Finally, treatments involving liquids and vapors require caution, as steam, alcohol, and household bleach all may lead to degradation of the filtration efficiency, leaving the user vulnerable to the viral aerosols.

60 APPLIED LIFE SCIENCES↗

A Parameterization of Turbulent Dissipation and Pressure Damping Time Scales in Stably Stratified Inversions, and its Effects on Low Clouds in Global Simulations

Abstract It is difficult for coarse‐resolution global models of the atmosphere to accurately simulate the observed distribution of low clouds. In particular, it is difficult for moist turbulence closure models to simulate sufficiently bright near‐coastal stratocumulus (Sc) without simulating overly bright marine shallow cumuli (Cu). To parameterize bright Sc, a turbulence parameterization must damp the turbulent fluxes of heat and moisture above cloud top in order to prevent excessive entrainment of dry air into cloud top. To parameterize dim shallow Cu, the subgrid variances of temperature and moisture must remain large, in order to permit partial cloudiness. However, damping the fluxes but not the variances just above cloud top is difficult if a parameterization uses a single “master” time scale to damp both. In nature, the above‐cloud fluxes are damped by pressure fluctuations, whereas scalar variances are damped by a different process, namely, turbulent dissipation. In a stably stratified inversion above cloud, pressure damping is large but turbulent dissipation is small. To avoid this problem, a multitime scale parameterization for damping has been developed. The damping parameterization has been implemented in a global model and evaluated. The parameterization is capable of dimming shallow Cu while producing adequately bright Sc.

54 ENVIRONMENTAL SCIENCES↗

Boundary layer moisture variability at the Atmospheric Radiation Measurement (ARM) Eastern North Atlantic observatory during marine conditions

Abstract. Boundary layer moisture variability at the Eastern North Atlantic (ENA) site during marine conditions is examined at monthly and daily timescales using 5 years of ground-based observations and output from the European Center for Medium range Weather Forecast (ECMWF) reanalysis model. The annual cycle of the mixed-layer total water budgets is presented to estimate the relative contribution of large-scale advection, local moisture tendency, entrainment, and precipitation to balance the moistening due to surface latent heat flux on monthly timescales. When marine conditions prevail, advection of colder and dry air from the north acts as an important moisture sink (∼ 50 % of the overall budget) during fall and winter driving the seasonality of the budget. Entrainment and precipitation contribute to the drying of the boundary layer (∼ 25 % and ∼ 15 % respectively), and the local change in moisture contributes to a small residual part. On a daily temporal scale, moist and dry mesoscale columns of vapor (∼ 10 km) are analyzed during 10 selected days of precipitating stratocumulus clouds. Adjacent moist and dry columns present distinct mesoscale features that are strongly correlated with clouds and precipitation. Dry columns adjacent to moist columns have more frequent and stronger downdrafts immediately below the cloud base. Moist columns have more frequent updrafts, stronger cloud-top cooling, and higher liquid water path and precipitation compared to the dry columns. This study highlights the complex interaction between large-scale and local processes controlling the boundary layer moisture and the importance of spatial distribution of vapor to support convection and precipitation.

54 ENVIRONMENTAL SCIENCES↗

Assessing impacts of selective logging on water, energy, and carbon budgets and ecosystem dynamics in Amazon forests using the Functionally Assembled Terrestrial Ecosystem Simulator

Abstract. Tropical forest degradation from logging, fire, and fragmentation not only alters carbon stocks and carbon fluxes, but also impacts physical land surface properties such as albedo and roughness length. Such impacts are poorly quantified to date due to difficulties in accessing and maintaining observational infrastructures, as well as the lack of proper modeling tools for capturing the interactions among biophysical properties, ecosystem demography, canopy structure, and biogeochemical cycling in tropical forests. As a first step to address these limitations, we implemented a selective logging module into the Functionally Assembled Terrestrial Ecosystem Simulator (FATES) by mimicking the ecological, biophysical, and biogeochemical processes following a logging event. The model can specify the timing and aerial extent of logging events, splitting the logged forest patch into disturbed and intact patches; determine the survivorship of cohorts in the disturbed patch; and modifying the biomass and necromass (total mass of coarse woody debris and litter) pools following logging. We parameterized the logging module to reproduce a selective logging experiment at the Tapajós National Forest in Brazil and benchmarked model outputs against available field measurements. Our results suggest that the model permits the coexistence of early and late successional functional types and realistically characterizes the seasonality of water and carbon fluxes and stocks, the forest structure and composition, and the ecosystem succession following disturbance. However, the current version of FATES overestimates water stress in the dry season and therefore fails to capture seasonal variation in latent and sensible heat fluxes. Moreover, we observed a bias towards low stem density and leaf area when compared to observations, suggesting that improvements are needed in both carbon allocation and establishment of trees. The effects of logging were assessed by different logging scenarios to represent reduced impact and conventional logging practices, both with high and low logging intensities. The model simulations suggest that in comparison to old-growth forests the logged forests rapidly recover water and energy fluxes in 1 to 3 years. In contrast, the recovery times for carbon stocks, forest structure, and composition are more than 30 years depending on logging practices and intensity. This study lays the foundation to simulate land use change and forest degradation in FATES, which will be an effective tool to directly represent forest management practices and regeneration in the context of Earth system models.

54 ENVIRONMENTAL SCIENCES↗

Testing Various Cement Formulations under Temperature Cycles and Drying Shrinkage for Low-Temperature Geothermal Wells

Low-enthalpy geothermal wells are considered a sustainable energy source, particularly for district heating in the Netherlands. The cement sheath in these wells experiences thermal cycles. The stability of cement recipes under such conditions is not well understood. In this work, thermal cycling experiments for intermediate- and low-temperature geothermal well cements have been conducted. The samples were cured either under ambient conditions or under realistic pressure and temperature for 7 days. The samples did not show any signs of failure after performing 10 cycles of thermal treatment between 100 °C and 18 °C. We also tested cement formulations under drying conditions. Drying shrinkage is caused by a reduction in the water content of cement, which leads to capillary forces that can damage cement. Such circumstances lead to tensile stresses causing radial cracks. Most samples exhibited cracks under low humidity conditions (drying). Fiber reinforcement, especially using short PP fibers, improved the cement’s resilience to temperature and humidity changes. Such additives can improve the longevity of cement sheaths in geothermal wells.

36 MATERIALS SCIENCE↗

Characterizing the effect of incrementally increasing dry bulb temperature on linear and nonlinear measures of heart rate variability in nonpregnant, mid-gestation, and late-gestation sows

Abstract Characterizing the sow physiological response to an increased heat load is essential for effective heat stress mitigation. The study objective was to characterize the effects of a 400-min heating episode on sow heart rate variability (HRV) at different reproductive stages. HRV is a commonly used noninvasive proxy measure of autonomic function. Twenty-seven sows were enrolled in the study according to their gestation stage at time of selection: 1) nonpregnant (NP; n = 7), 2) mid-gestation (MID; 57.3 ± 11.8 d gestation; n = 11), and 3) late-gestation (LATE; 98.8 ± 4.9 d gestation; n = 8). The HRV data utilized in the study were collected from each pig as the dry bulb temperature in the room increased incrementally from 19.84 ± 2.15 °C to 35.54 ± 0.43 °C (range: 17.1–37.5 °C) over a 400-min period. After data collection, one 5-min set of continuous heart rate data were identified per pig for each of nine temperature intervals (19–20.99, 21–22.99, 23–24.99, 25–26.99, 27–28.99, 29–30.99, 31–32.99, 33–34.99, and 35–36.99 °C). Mean inter-beat interval length (RR), standard deviation of r-r intervals (SDNN), root mean square of successive differences (RMSSD), high frequency spectral power (HF), sample entropy (SampEn), short-term detrended fluctuation analysis (DFAα1), and three measures (%REC, DET, LMEAN) derived from recurrence quantification analysis were calculated for each data set. All data were analyzed using the PROC GLIMMIX procedure in SAS 9.4. Overall, LATE sows exhibited lower RR than NP sows (P < 0.01). The standard deviation of r–r intervals and RMSSD differed between each group (P < 0.01), with LATE sows exhibiting the lowest SDNN and RMSSD and NP sows exhibiting the greatest SDNN and RMSSD. Late-gestation sows exhibited lower HF than both MID and NP sows (P < 0.0001), greater DFA values than NP sows (P = 0.05), and greater DET compared to MID sows (P = 0.001). Late-gestation also sows exhibited greater %REC and LMEAN compared to MID (P < 0.01) and NP sows (all P < 0.01). In conclusion, LATE sows exhibited indicators of greater autonomic stress throughout the heating period compared to MID and NP sows. However, temperature by treatment interactions were not detected as dry bulb increased. Future studies are needed to fully elucidate the effect of gestational stage and increasing dry bulb temperature on sow HRV.

Agriculture↗

Modeling Land-Atmosphere Coupling at Cloud-Resolving Scale Within the Multiple Atmosphere Multiple Land (MAML) Framework in SP-E3SM

Representing subgrid variabilities of land surface processes and their upscaled effects is crucial for global climate modeling. Here, we implement a Multiple Atmosphere Multiple Land (MAML) framework in the superparamaterized version of E3SM (SP32 E3SM) to explicitly simulate the subgrid variabilities of land states and fluxes at cloud-resolving scale and their interactions with atmosphere. Comparing to the standard SP-E3SM in which all the atmospheric columns of the cloud resolving model embedded within the global atmospheric model grid interact with the same land surface (i.e., Multiple Atmosphere Single Land (MASL)), the impact of MAML on the strength of land-atmosphere coupling is limited, partly because the current implementation mainly facilitates one-way coupling between the cloud-resolving model and the land surface model. Despite such limitation, MAML increases the surface latent heat flux at the expense of sensible heat flux, and increases precipitation in India, Amazon, and Central Africa, reducing the model dry bias compared to the standard SP-E3SM. By employing a normalized gross moist stability (NGMS) diagnostic framework, we find that the increase in precipitation minus evaporation (PE) is primarily driven by the change in large-scale moisture convergence, particularly by the increase of water vapor in the lower atmosphere, while the local effect of total surface energy flux plays a minor role in the P-E change. More specifically, MAML changes the surface energy partitioning (evaporative fraction), increases the atmosphere water vapor, and further increases P-E by decreasing the NGMS. Finally, future development in the MAML framework is discussed.

54 ENVIRONMENTAL SCIENCES↗

An Energetic Diagnostic of Tropical Cyclone Size in f –Plane Simulations

As a major feature of tropical cyclones (TCs), controlling factors of TC outer size or size scaling remains a fundamental scientific question. The Rossby deformation radius and a natural extent associated with potential intensity have been proposed as two scalings of TC size. But neither of them satisfactorily captures the sensitivity of TC size to sea surface temperature (SST) in idealized f-plane simulations. Inspired by the studies of the Hadley circulation, here we proposed a new TC scaling based on an energetic diagnostic scaling. TC size is primarily a ratio of the secondary circulation strength to subsidence velocity, further determined by the total atmospheric heating in the ascending area, the gross moist stability, the diabatic cooling, and the dry static stability. The former two is based on the moist energetic budget applied to the whole storm structure, while the latter two is based on the dry thermodynamic budget applied to the subsidence areas. The new scaling well captured the sensitivity of TC size to SST in idealized f-plane simulations, partly resulted from expanded ascending area, increased surface moisture deficit, and weakened subsidence with increased SST.

58 GEOSCIENCES↗

Solid electrolyte technology with rearrangeable bonds for metal and metal-ion batteries

In an embodiment, a metal or metal-ion battery cell, includes anode and cathode electrodes, a separator electrically separating the anode and the cathode, and a solid electrolyte ionically coupling the anode and the cathode, wherein the solid electrolyte comprises a material having one or more rearrangeable chalcogen-metal-hydrogen groups that are configured to transport at least one metal-ion or metal-ion mixture through the solid electrolyte, wherein the solid electrolyte exhibits a melting point below about 350° C. In an example, the solid electrolyte may be produced by mixing different dry metal-ion compositions together, arranging the mixture inside of a mold, and heating the mixture while arranged inside of the mold at least to a melting point (e.g., below about 350° C.) of the mixture so as to produce a material comprising one or more rearrangeable chalcogen-metal-hydrogen groups.

Yushin, Gleb↗

Thermal-hydraulic and Fuel Performance Scoping Studies of a Flowing Water Capsule in TREAT

The restart of the Transient Reactor Test (TREAT) facility has provided a much needed capability for integral transient testing of nuclear fuel. This testing is necessary to qualify new fuel concepts such as those developed under the Accident Tolerant Fuel (ATF) program, increasing the burnup limit of light water reactor (LWR) fuels, or a variety of other programs under the Advanced Fuels Campaign (AFC). The ATF campaign has been the main driver behind the development and implementation of a variety of capsules for TREAT experiments. The Separate-Effect Test Holder (SETH) was a dry capsule that enabled testing of ATF concepts under reactivity-initiated accident (RIA) heating conditions. Following SETH, the Static Environment Rodlet Transient Test Apparatus (SERTTA) was developed to enable RIA testing in a static water environment. In efforts to support the need for future Loss-of-Coolant Accident (LOCA) tests, the Transient Water Irradiation System for TREAT (TWIST) capsule has been developed that allows for water to drain from around the fuel rod and lower the pressure to simulate LOCA conditions. All these capsules that have been developed for LWR fuel testing all lack the capability for forced convective cooling which in some applications may limit their ability to test under prototypic conditions. A design and modeling effort has been started to modify the TWIST capsule by adding a flow tube and impeller that can create flowing coolant conditions for the fuel rod. RELAP5-3D and BISON models are being used to study the differences between RIA, LOCA, Anticipated Operational Occurrences (AOO), LWR power cycling, and other transient scenarios under flowing conditions capable in the flowing capsule and the current stagnant water capsules (SERTTA and TWIST). The scoping study will provide guidance on the needed capabilities for the flowing capsule and the limitations of the currently developed capsule for LWR testing in TREAT.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Lignetics CRADA closeout report

Lignetics is one of the leading domestic producers of wood pellet fuels used for domestic heating. The company also produces pellets for other applications including animal bedding. The primary feedstock used for the production of Lignetics products is woody biomass. To improve the economics of pellet production, Lignetics is evaluating advanced preprocessing technologies developed by researchers at INL. In the proposed project, INL and Lignetics will work collaboratively to assess the feasibility of integrating INL’s advanced preprocessing technologies (fractional milling, high moisture pelleting and low temperature drying) in Lignetics production facilities. The successful completion of the project relies on the integration of the fractional milling and high moisture pelleting (HMP) process and low temperature drying to improve the economics of woody biomass pellet production for use in biofuel and bioproduct applications. In the HMP process, the biomass loses some moisture during compression and extrusion through the pellet die due frictional heat developed. Also, as pellets have a definite size and shape, they can be further dried in low temperature grain or belt dryers. Belt dryers are better suited to take advantage of low-grade and waste heat because they operate at lower temperatures than rotary dryers (Tumuluru et al.) Rotary dryers, for example, typically require inlet temperatures of 260°C, but more optimally operate around 400°C. In contrast, the inlet temperature of a belt dryer, such as a commercially available vacuum dryer, can be as low as 10°C above the ambient temperature, although more typically they operate at higher temperatures, between 90°C and 200°C. Because of their lower temperature operation, fire hazards and emissions to the air are lower for belt dryers in addition to reducing drying and overall pelleting costs, INL’s technology also has potential to reduce emissions at Lignetics facilities.

09 BIOMASS FUELS↗

Newton trust-region methods with primary variable switching for simulating high temperature multiphase porous media flow

Coupling multiphase flow with energy transport due to high temperature heat sources introduces significant new challenges since boiling and condensation processes can lead to dry-out conditions with subsequent re-wetting. The transition between two-phase and single-phase behavior can require changes to the primary dependent variables adding discontinuities as well as extending constitutive nonlinear relations to extreme physical conditions. Practical simulations of large-scale engineered domains lead to Jacobian systems with a very large number of unknowns that must be solved efficiently using iterative methods in parallel on high-performance computers. Performance assessment of potential nuclear repositories, carbon sequestration sites and geothermal reservoirs can require numerous Monte-Carlo simulations to explore uncertainty in material properties, boundary conditions, and failure scenarios. Due to the numerical challenges, standard NR iteration may not converge over the range of required simulations and require more sophisticated optimization method like trust-region. In this study, we use the open-source simulator PFLOTRAN for the important practical problem of the safety assessment of future nuclear waste repositories in the U.S. DOE geologic disposal safety assessment Framework. The simulator applies the PETSc parallel framework and a backward Euler, finite volume discretization. We demonstrate failure of the conventional NR method and the success of trust-region modifications to Newton’s method for a series of test problems of increasing complexity. Trust-region methods essentially modify the Newton step size and direction under some circumstances where the standard NR iteration can cause the solution to diverge or oscillate. Furthermore, we show how the Newton Trust-Region method can be adapted for Primary Variable Switching (PVS) when the multiphase state changes due to boiling or condensation. The simulations with high-temperature heat sources which led to extreme nonlinear processes with many state changes in the domain did not converge with NR, but they do complete successfully with the trust-region methods modified for PVS. This implementation effectively decreased weeks of simulation time needing manual adjustments to complete a simulation down to a day. Finally, we show the strong scalability of the methods on a single node and multiple nodes in an HPC cluster.

54 ENVIRONMENTAL SCIENCES↗

Experimental warming and drying increase older carbon contributions to soil respiration in lowland tropical forests

Tropical forests account for over 50% of the global terrestrial carbon sink, but climate change threatens to alter the carbon balance of these ecosystems. We show that warming and drying of tropical forest soils may increase soil carbon vulnerability, by increasing degradation of older carbon. In situ whole-profile heating by 4 °C and 50% throughfall exclusion each increased the average radiocarbon age of soil CO 2 efflux by ~2–3 years, but the mechanisms underlying this shift differed. Warming accelerated decomposition of older carbon as increased CO 2 emissions depleted newer carbon. Drying suppressed decomposition of newer carbon inputs and decreased soil CO 2 emissions, thereby increasing contributions of older carbon to CO 2 efflux. These findings imply that both warming and drying, by accelerating the loss of older soil carbon or reducing the incorporation of fresh carbon inputs, will exacerbate soil carbon losses and negatively impact carbon storage in tropical forests under climate change.

54 ENVIRONMENTAL SCIENCES↗

Wildfire-Power Grid Interactions: Feedback, Impacts, Monitoring, Modeling, and Mitigation Strategies

Wildfires are increasingly interacting with electric power systems through a two-way hazard chain: fires damage grid assets and trigger cascading outages, while grid faults can ignite new fires under hot, dry, and windy conditions. This review synthesizes the state of knowledge across five domains: (i) physical impacts of flames, heat, and smoke on lines, towers, insulators, and substations; (ii) power-infrastructure-initiated ignitions via conductor clash, high-impedance faults, and corona discharge; (iii) widespread blackouts and disproportionate societal impacts; (iv) multi-scale monitoring spanning laboratory tests, in-situ and grid-integrated sensors, and Earth observation; (v) coupled modeling that links fire behavior with grid operations; and (vi) technological and strategic mitigation pathways spanning prevention, response, and recovery. We integrate these domains into a novel 'feedback-aware' socio-technical framework. Through a longitudinal analysis (2005-2025) of global incidents, we identify that while vegetation contact remains the most frequent ignition source, aging infrastructure failure has emerged as a critical driver of catastrophic 'mega-fires'. We further identify persistent gaps, including limited interoperability of high-frequency grid and environmental data, scarce real-time data assimilation, and under-developed equity metrics for outage management. We conclude by outlining a research agenda to (1) deploy interoperable sensing architectures, (2) advance feedback-coupled fire-grid simulations, and (3) evaluate mitigation portfolios through techno-economic and fairness lenses. Recognizing wildfire-grid interactions as coupled socio-technical systems is essential for protecting infrastructure and communities and for ensuring reliable, sustainable electricity in a changing world.

24 POWER TRANSMISSION AND DISTRIBUTION↗