Search NASA⌕ Search

SEARCH · Search NASA

Results for “Damage characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Breakdown characteristics and conditioning of carbon and refractory metal electrodes

High voltage carbon and refractory metal electrodes employed in devices used in space, such as ion thrusters and traveling wave tubes, can be easily damaged by electrical breakdown and arcing events. Modification of the electrode surfaces due to these events can impact the voltage hold off capability of the surfaces, which could lead to additional arcing, further damage, and the potential for device failure. On the cathode-potential surface, the arc energy is deposited by all of the processes at the surface ultimately responsible for net electron emission, such as melting, vapor and particulate formation, sputtering, ion bombardment, etc. On the anode-potential surface, the energy is deposited from the plasma or electron stream that crosses the gap, which causes surface damage by local heating. In spite of this energy dependence on the damage, many systems that use arc discharges characterize the amount of material removed from the surfaces and the lifetime of the device for voltage hold-off by the amount of current that passes through the arc, or the 'Coulomb-rating'. The results of a series of tests that were preformed on the boltage hold off capability and damage to carbon-carbon composite surfaces and molybdenum surfaces due to induced arcing will be presented and discussed. Damage to the surfaces was characterized by the field emission performance after the arc initiation and SEM photographs for the different energy and coulomb-transfer arc conditions. Both conditioning and damage to the surfaces were observed, and will be related to the characteristics of the electrical breakdown.

high voltage breakdown↗

Health Monitoring for Airframe Structural Characterization

This study established requirements for structural health monitoring systems, identified and characterized a prototype structural sensor system, developed sensor interpretation algorithms, and demonstrated the sensor systems on operationally realistic test articles. Fiber-optic corrosion sensors (i.e., moisture and metal ion sensors) and low-cycle fatigue sensors (i.e., strain and acoustic emission sensors) were evaluated to validate their suitability for monitoring aging degradation; characterize the sensor performance in aircraft environments; and demonstrate placement processes and multiplexing schemes. In addition, a unique micromachined multimeasure and sensor concept was developed and demonstrated. The results show that structural degradation of aircraft materials could be effectively detected and characterized using available and emerging sensors. A key component of the structural health monitoring capability is the ability to interpret the information provided by sensor system in order to characterize the structural condition. Novel deterministic and stochastic fatigue damage development and growth models were developed for this program. These models enable real time characterization and assessment of structural fatigue damage.

Munns, Thomas E.↗

Cohesive Laws and Progressive Damage Analysis of Composite Bonded Joints, a Combined Numerical/Experimental Approach

The results of an experimental/numerical campaign aimed to develop progressive damage analysis (PDA) tools for predicting the strength of a composite bonded joint under tensile loads are presented. The PDA is based on continuum damage mechanics (CDM) to account for intralaminar damage, and cohesive laws to account for interlaminar and adhesive damage. The adhesive response is characterized using standard fracture specimens and digital image correlation (DIC). The displacement fields measured by DIC are used to calculate the J-integrals, from which the associated cohesive laws of the structural adhesive can be derived. A finite element model of a sandwich conventional splice joint (CSJ) under tensile loads was developed. The simulations, in agreement with experimental tests, indicate that the model is capable of predicting the interactions of damage modes that lead to the failure of the joint.

Girolamo, Donato↗

Fatigue behavior of adhesively bonded joints

The fatigue damage mechanism of composite to composite adhesively bonded joints was characterized. The mechanics of the possible modes of fatigue damage propagation in these joints when subjected to constant amplitude cyclic mechanical loading were investigated. The possible failure modes in composite bonded joints may be cyclic debonding (i.e., progressive separation of the adhesive), interlaminar damage (delamination), adherend fatigue or a combination of these. Two composite systems - graphite/epoxy adhesively bonded to graphite/epoxy and Kevlar 49/epoxy adhesively bonded to Kevlar 49/epoxy were investigated. Both composite systems consisted of quasi-isotropic lay-ups, i.e., 0 deg/-45 deg/+45 deg/90 degs. The two adhesives, employed in the study were (1) EC 3445 with cure temperature of 250 F for secondary bonding and (2) FM 300 with cure temperature of 350 F for co-cure bonding.

Mall, S.↗

Synchrotron/crystal sample preparation

The Center for Applied Optics (CAO) of the University of Alabama in Huntsville (UAH) prepared this final report entitled 'Synchrotron/Crystal Sample Preparation' in completion of contract NAS8-38609, Delivery Order No. 53. Hughes Danbury Optical Systems (HDOS) is manufacturing the Advanced X-ray Astrophysics Facility (AXAF) mirrors. These thin-walled, grazing incidence, Wolter Type-1 mirrors, varying in diameter from 1.2 to 0.68 meters, must be ground and polished using state-of-the-art techniques in order to prevent undue stress due to damage or the presence of crystals and inclusions. The effect of crystals on the polishing and grinding process must also be understood. This involves coating special samples of Zerodur and measuring the reflectivity of the coatings in a synchrotron system. In order to gain the understanding needed on the effect of the Zerodur crystals by the grinding and polishing process, UAH prepared glass samples by cutting, grinding, etching, and polishing as required to meet specifications for witness bars for synchrotron measurements and for investigations of crystals embedded in Zerodur. UAH then characterized these samples for subsurface damage and surface roughness and figure.

Johnson, R. Barry↗

Certification of damage tolerant composite structure

A reliability based certification testing methodology for impact damage tolerant composite structure was developed. Cocured, adhesively bonded, and impact damaged composite static strength and fatigue life data were statistically analyzed to determine the influence of test parameters on the data scatter. The impact damage resistance and damage tolerance of various structural configurations were characterized through the analysis of an industry wide database of impact test results. Realistic impact damage certification requirements were proposed based on actual fleet aircraft data. The capabilities of available impact damage analysis methods were determined through correlation with experimental data. Probabilistic methods were developed to estimate the reliability of impact damaged composite structures.

Rapoff, Andrew J.↗

An Efficient Single Frequency Ho:YLF Laser for IPDA Lidar Applications

A highly efficient, versatile, single frequency 2-micron pulsed laser can be used in a pulsed Differential Absorption Lidar (DIAL) / Integrated Path Differential Absorption (IPDA) instrument to make precise, high-resolution measurements to investigate sources and sinks of CO2. For a direct detection IPDA lidar, the desired 2 m Ho:YLF laser should generate 30-40 mJ pulses at the repetition rate of 100 to 200 Hz, with short pulse length (<100 ns) and better than 2% wall plug efficiency. A Tm fiber laser in-band pumped Ho:YLF laser has been developed to meet this technical challenge. This Ho:YLF laser is designed in a four mirror ring resonator with bow tie configuration, which helps to obtain high beam quality. It is end-pumped by a 40 W linearly polarized Tm fiber laser at 1.94μm. The resonator length is 1.10 meters with output coupler reflectivity at 45%. The laser crystal size is 3 x 3 x 60 mm (w, h, l) with a doping concentration of 0.5% Holmium. The laser beam and pump beam are mode-matched in the active medium. Thus, the pump and laser beams have the same confocal parameters. Mode-matching is also helpful for operating the laser in a single transverse mode. The laser beam waist is slightly less than 0.5 mm at the center of the laser crystal. Based on quasi-four level modeling, pump absorption and saturation depend on laser intensity. Laser amplification and saturation also depend on the pump intensity in the crystal. The laser is injection seeded to obtain the single frequency required by an IPDA lidar measurement. The seed beam is entered into the resonator through an output coupler. The laser is mounted on a water cooled optical bench for stable and reliable operation. The size of the optical bench is 22.16 x 9.20 x 1.25 inches. It is stiffened so that the laser can be operated in any orientation of the optical bench. This packaged Ho:YLF laser is designed for either mobile trailer or airborne platform operation. The engineering prototype Ho:YLF laser has been fully characterized to demonstrate laser performance. Figure 1 shows the laser output power as a function of pump power at different pulse repetition rates from 100 Hz to 333 Hz. The threshold of the laser is less than 14 W. The slope efficiencies are 28%, 40%, 41% and 43% for pulse repetition rates of 100, 200, 250 and 333 Hz, respectively. Maximum power increases with the pulse repetition rate. Output power of 4.2 W, 6 W, 6.7 W, and 7.7 W is achieved for pulse repetition rates of 100, 200, 250 and 333Hz, respectively. This represents the optical conversion efficiency of 16.7%, 22.4%, 23.7%, and 26.5% at these various pulse repletion rates. It is the most efficient and compact Ho:YLF laser demonstrated in the high pulse energy (>20mJ) and moderate pulse repetition rate (100's Hz) operation range. As shown in Figure 1, the maximum pulse energy at 100 Hz is 42 mJ. This is limited due to optical damage. The laser stability is characterized and found to be very stable. A relative pulse energy standard deviation of 2% was measured. The beam quality of the Ho:YLF was measured by a Spiricon infrared laser beam camera. Figure 2 shows the beam profile image of the laser. Both the X-profile of the beam (horizontal direction) and the Y-profile of the beam (vertical direction) are well fitted by a Gaussian profile. The qualitative beam quality measurement shows excellent beam quality in both axis. The M-square value for the laser beam is measured at 1.06 and 1.09 for the x and y axis respectively.-

Yu, J.↗

Understanding spectral dependance of laser-induced damage precursors in dielectric materials (Full report_23-ERD-006)

The performance of high-energy laser systems is constrained by laser-induced damage in dielectric coatings, particularly those containing hafnium oxide (HfO 2 ). While thresholds at fundamental Nd harmonics are well studied, the spectral dependence of damage initiation—especially under dual-wavelength irradiation—remains poorly characterized. This project provides the first systematic investigation of wavelength-dependent laser damage in hafnia coatings, focusing on nanoscale precursors such as craze lines, nanobubbles, stoichiometric variations, nodules, and controlled crystallization. Coatings were fabricated via ion beam sputtering and electron-beam deposition and characterized using spectrophotometry, ellipsometry, AFM, GI-XRD, RBS, PCI absorption, and fs/ns laser damage testing. Results show that craze lines, benign under infrared light, strongly initiate damage under UV due to wavelength-selective field intensification. Substituting xenon for argon suppresses nanobubbles and improves UV thresholds by up to 32%. Oxygen modulation reveals that fully oxidized films maximize UV resistance, though at the cost of porosity and stress in multilayers. HfO 2 –SiO 2 composites resist crystallization and defects while achieving ppm-level absorption and elevated thresholds, whereas full crystallization of HfO 2 enhances LIDT by reducing defects and improving thermal transport. Collectively, these findings link photon energy, defect states, and bandgap collapse, providing a predictive framework for wavelength-dependent laser damage. The outcomes directly inform the design of durable, multi-wavelength coatings for facilities such as NIF, MEC, HAPLS, and DPAL, advancing the readiness of next-generation optics.

36 MATERIALS SCIENCE↗

An advanced test technique to quantify thermomechanical fatigue damage accumulation in composite materials

A mechanical test technique was developed to assist in quantifying the accumulation of damage in composite materials during thermomechanical fatigue (TMF) cycling. This was accomplished by incorporating definitive elastic mechanical property measurements into an ongoing load-controlled TMF test without disturbing the test specimen or significantly altering the test conditions. The technique allows two fundamental composite properties consisting of the isothermal elastic static moduli and the macroscopic coefficient of thermal expansion (CTE) to be measured and collected as functions of the TMF cycles. The specific implementation was incorporated into the commonly employed idealized in-phase and out-of-phase TMF cycles. However, the techniques discussed could be easily implemented into any form of load-controlled TMF mission cycle. By quantifying the degradations of these properties, tremendous insights are gained concerning the progression of macroscopic composite damage and often times the progression of damage within a given constituent. This information should also be useful for the characterization and essential for the verification of analytical damage modeling methodologies. Several examples utilizing this test technique are given for three different fiber lay-ups of titanium metal matrix composites.

Castelli, Michael G.↗

Synergistic Effects of Physical Aging and Damage on Long-Term Behavior of Polymer Matrix Composites

The research consisted of two major parts, first modeling and simulation of the combined effects of aging and damage on polymer composites and secondly an experimental phase examining composite response at elevated temperatures, again activating both aging and damage. For the simulation, a damage model for polymeric composite laminates operating at elevated temperatures was developed. Viscoelastic behavior of the material is accounted for via the correspondence principle and a variational approach is adopted to compute the temporal stresses within the laminate. Also, the effect of physical aging on ply level stress and on overall laminate behavior is included. An important feature of the model is that damage evolution predictions for viscoelastic laminates can be made. This allows us to track the mechanical response of the laminate up to large load levels though within the confines of linear viscoelastic constitutive behavior. An experimental investigation of microcracking and physical aging effects in polymer matrix composites was also pursued. The goal of the study was to assess the impact of aging on damage accumulation, in ten-ns of microcracking, and the impact of damage on aging and viscoelastic behavior. The testing was performed both at room and elevated temperatures on [+/- 45/903](sub s) and [02/903](sub s) laminates, both containing a set of 90 deg plies centrally located to facilitate investigation of microcracking. Edge replication and X-ray-radiography were utilized to quantify damage. Sequenced creep tests were performed to characterize viscoelastic and aging parameters. Results indicate that while the aging times studied have limited ]Influence on damage evolution, elevated temperature and viscoelastic effects have a profound effect on the damage mode seen. Some results are counterintuitive, including the lower strain to failure for elevated temperature tests and the catastrophic failure mode observed for the [+/- 45/9O3](sub s), specimens. The fracture toughness for transverse cracks increases with increasing temperature for both systems: transverse cracking was completely absent prior to failure in [+/- 45/903](sub s), and was suppressed for [02/903](sub s). No significant effect of damage on aging or viscoelastic parameters was observed.

Brinson, L. Cate↗

Tailoring additive manufacturing to optimize dynamic properties in 316L stainless steel

With the advent of additive manufacturing, manipulation of typical microstructural elements such as grain size, texture, and defect densities is now possible at a faster time scale. While the processing–structure–property relationship in additive manufactured metals has been well studied over the past decade, little work has been done in understanding how this process affects the dynamic behavior of materials. We postulate that additive manufacturing can be used to alter the material microstructure and used to enhance its dynamic strength. In this work, 316L stainless steel (SS) was manufactured via selected laser melting and its microstructure was altered through changing build parameters like laser power, speed, and hatch spacing systematically. These samples were then subjected to spall recovery experiments to measure the spall strength and quantify the amount of damage as a function of build parameters. By mapping the spall strength as a function of build parameters, this work demonstrated that indeed additive manufacturing can be used to tailor the spall strength of 316L SS. This work also determined the optimum build parameters (laser power=195W; scanning speed=1083mm/s; hatch spacing=0.09mm; layer thickness=0.02mm) to obtain the highest spall strength and the least amount of total damage in 316L SS. Microstructural characterization of the pre- and post-mortem samples revealed that increased grain average misorientation and textural index were the main driving force behind this higher spall strength. This work aims to enhance microstructural engineering techniques to design materials with greater resistance to dynamic shock loading.

36 MATERIALS SCIENCE↗

Embedded gage impact study

Impact damage in graphite/epoxy laminates was characterized and transient strain history during impact was correlated. The material investigated was AS-4/3501-6 graphite/epoxy. Eight-ply and sixteen-ply quasi-isotropic laminates of 45/0/-45/90 sub s and 45/0/-45/90 sub 2s layups were fabricated with strain gages embedded between plies during the strain gages and leads from the highly conductive graphite fibers. The specimens were circular plates 12.7 cm (5 in.) in diameter and clamped along their circumference. The specimens were impacted with a 185 gm impactor, dropped from heights of 1.20 m and 1.65 m. An accelerometer was attached to the back surface of the specimen opposite the impact point and was used to trigger the recording instrumentation. The transient strain data were recorded with an eight channel waveform digitizer capable of sampling data at 0.5 microsec intervals. The data were stored, processed, and plotted by means of a microcomputer. Transient strain data were correlated with results from ultrasonic inspection of the specimens.

Schramm, S. W.↗