Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data acquisition circuits”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

NASA F-106B lightning tests

Lightning simulation ground tests conducted on the NASA F-106B research aircraft to elicit natural strikes are summarized. The purpose of the test program was to measure the response of the aircraft's electromagnetic sensors and interior wire circuits to a controlled ground test environment that simulates the electromagnetic effects of a lightning strike. Both direct attachment and radiated field tests were conducted. In most cases, the aircraft's engine was running and test data were gathered simultaneously from NASA and MCAIR sensors on both the aircraft's own instrumentation system and the remote MCAIR computer-controlled data acquisition system. During the direct attachment tests, the input inductance, output condition (hard-wired or spark gap), and the output location were varied to provide a wide variety of test conditons. The radiated tests to the isolated aircraft were conducted to excite and measure the natural resonances of the F-106B aircraft.

Heady, B. D.↗

Magnetic Field Response Measurement Acquisition System

This paper presents a measurement acquisition method that alleviates many shortcomings of traditional measurement systems. The shortcomings are a finite number of measurement channels, weight penalty associated with measurements, electrical arcing, wire degradations due to wear or chemical decay and the logistics needed to add new sensors. Wire degradation has resulted in aircraft fatalities and critical space launches being delayed. The key to this method is the use of sensors designed as passive inductor-capacitor circuits that produce magnetic field responses. The response attributes correspond to states of physical properties for which the sensors measure. Power is wirelessly provided to the sensing element by using Faraday induction. A radio frequency antenna produces a time-varying magnetic field used to power the sensor and receive the magnetic field response of the sensor. An interrogation system for discerning changes in the sensor response frequency, resistance and amplitude has been developed and is presented herein. Multiple sensors can be interrogated using this method. The method eliminates the need for a data acquisition channel dedicated to each sensor. The method does not require the sensors to be near the acquisition hardware. Methods of developing magnetic field response sensors and the influence of key parameters on measurement acquisition are discussed. Examples of magnetic field response sensors and the respective measurement characterizations are presented. Implementation of this method on an aerospace system is discussed.

Woodard, Stanley E.↗

Contour Detector and Data Acquisition System for the Left Ventricular Outline

A real-time contour detector and data acquisition system is described for an angiographic apparatus having a video scanner for converting an X-ray image of a structure characterized by a change in brightness level compared with its surrounding into video format and displaying the X-ray image in recurring video fields. The real-time contour detector and data acqusition system includes track and hold circuits; a reference level analog computer circuit; an analog compartor; a digital processor; a field memory; and a computer interface.

Reiber, J. H. C.↗

Software For A Laser Vibrometer

Vibration Pattern Imager (VPI) system and software designed to control and acquire data from laser vibrometer sensors. Based on personal computer, includes digital signal-processing (DSP) board and analog input/output (I/O) circuit board to control sensors and process data. Originally developed for use with Ometron VPI Sensor, adapted to any commercially available sensor that provides analog output signal and requires analog inputs for control of mirror position. VPI system includes graphical user interface providing for interactive control through keyboard and mouse-selected menu options. Main menu controls all functions for setup, acquisition of data, display, file operations, and leaving program. Two types of data acquired with system: single point or "full field". Written in C language and Texas Instrument' TMS320C30 assembly language.

Rizzi, Stephen A.↗

Pressure Measurement Systems

System 8400 is an advanced system for measurement of gas and liquid pressure, along with a variety of other parameters, including voltage, frequency and digital inputs. System 8400 offers exceptionally high speed data acquisition through parallel processing, and its modular design allows expansion from a relatively inexpensive entry level system by the addition of modular Input Units that can be installed or removed in minutes. Douglas Juanarena was on the team of engineers that developed a new technology known as ESP (electronically scanned pressure). The Langley ESP measurement system was based on miniature integrated circuit pressure-sensing transducers that communicated pressure information to a minicomputer. In 1977, Juanarena formed PSI to exploit the NASA technology. In 1978 he left Langley, obtained a NASA license for the technology, introduced the first commercial product, the 780B pressure measurement system. PSI developed a pressure scanner for automation of industrial processes. Now in its second design generation, the DPT-6400 is capable of making 2,000 measurements a second and has 64 channels by addition of slave units. New system 8400 represents PSI's bid to further exploit the $600 million U.S. industrial pressure measurement market. It is geared to provide a turnkey solution to physical measurement.

Source record↗

3x3 array module of 8×8×32 mm 3 position-sensitive virtual frisch-grid CdZnTe detectors for imaging and spectroscopy of cosmic gamma-rays

Here, we evaluated the performance of the 3x3 array of 32-mm long position-sensitive virtual Frisch-grid (VFG) CdZnTe (CZT) detectors read out by the IDEAS GDS-100 data acquisition system. The array is a mechanically solid module designed for integration into a large effective area gamma-ray telescope proposed for imaging and spectroscopy of cosmic gamma-rays. The array employs the bar-shaped 8x8x32 mm 3 CZT crystals which recently became available from Redlen Technologies, Inc. and Kromek-eV Group PLC at affordable costs. The waveform sampling IDE3421 application-specific integrated circuit (ASIC), developed by the University of Michigan and IDEAS for CZT pixel detectors, was adapted to capture the signals from the array's VFG detectors. We showed good spectral performance of the Redlen detectors with an energy resolution of <1% FWHM at 662 keV and slightly poorer performance of the Kromek-eV detectors with a resolution of <2% measured at a reduced temperature of 13 °C. By testing the same detectors as single devices using hybrid charge-sensitive preamplifiers, we demonstrated improved energy resolutions at a normal temperature of ~25°C: <1% and 1.3-1.7%, respectively. However, the Kromek-eV detectors did not perform as well as the Redlen ones. We explained this by the space charge formation (polarization) decreasing the electric field and the electron drift times. The polarization was likely caused by the high injections of holes from the anode contacts. The absence of polarization in Redlen detectors suggested that the quality of the contacts might have played a role in this case.

47 OTHER INSTRUMENTATION↗

NASA Tech Briefs, October 2005

Topics covered include: Insect-Inspired Optical-Flow Navigation Sensors; Chemical Sensors Based on Optical Ring Resonators; A Broad-Band Phase-Contrast Wave-Front Sensor; Progress in Insect-Inspired Optical Navigation Sensors; Portable Airborne Laser System Measures Forest-Canopy Height; Deployable Wide-Aperture Array Antennas; Faster Evolution of More Multifunctional Logic Circuits; Video-Camera-Based Position-Measuring System; N-Type delta Doping of High-Purity Silicon Imaging Arrays; Avionics System Architecture Tool; Updated Chemical Kinetics and Sensitivity Analysis Code; Predicting Flutter and Forced Response in Turbomachinery; Upgrades of Two Computer Codes for Analysis of Turbomachinery; Program Facilitates CMMI Appraisals; Grid Visualization Tool; Program Computes Sound Pressures at Rocket Launches; Solar-System Ephemeris Toolbox; Data-Acquisition Software for PSP/TSP Wind-Tunnel Cameras; Corrosion-Prevention Capabilities of a Water-Borne, Silicone-Based, Primerless Coating; Sol-Gel Process for Making Pt-Ru Fuel-Cell Catalysts; Making Activated Carbon for Storing Gas; System Regulates the Water Contents of Fuel-Cell Streams; Five-Axis, Three-Magnetic-Bearing Dynamic Spin Rig; Modifications of Fabrication of Vibratory Microgyroscopes; Chamber for Growing and Observing Fungi; Electroporation System for Sterilizing Water; Thermoelectric Air/Soil Energy-Harvesting Device; Flexible Metal-Fabric Radiators; Actuated Hybrid Mirror Telescope; Optical Design of an Optical Communications Terminal; Algorithm for Identifying Erroneous Rain-Gauge Readings; Condition Assessment and End-of-Life Prediction System for Electric Machines and Their Loads; Lightweight Thermal Insulation for a Liquid-Oxygen Tank; Stellar Gyroscope for Determining Attitude of a Spacecraft; and Lifting Mechanism for the Mars Explorer Rover.

Source record↗

Data-Acquisition Software for PSP/TSP Wind-Tunnel Cameras

Wing-Viewer is a computer program for acquisition and reduction of image data acquired by any of five different scientificgrade commercial electronic cameras used at Langley Research center to observe wind-tunnel models coated with pressure or temperature-sensitive paints (PSP/TSP). Wing-Viewer provides full automation of camera operation and acquisition of image data, and has limited data-preprocessing capability for quick viewing of the results of PSP/TSP test images. Wing- Viewer satisfies a requirement for a standard interface between all the cameras and a single personal computer: Written by use of Microsoft Visual C++ and the Microsoft Foundation Class Library as a framework, Wing-Viewer has the ability to communicate with the C/C++ software libraries that run on the controller circuit cards of all five cameras.

Amer, Tahani R.↗

ADC evaluation boards design and test framework for LCLS-II precision receiver

In the low-level RF control field, ADC acquisition accuracy and noise set the boundary of our control ability, making it important to develop low-noise acquisition systems. From the design to test stage, all the noise terms should be understood and characterized. The specific need addressed here is the precision acquisition system for the second Linac Coherent Light Source (LCLS-II), led by SLAC National Accelerator Laboratory. Test circuit boards for the LTC2174 and AD9268 ADCs are designed and fabricated by LBNL. An ADC test framework based on FPGA evaluation board to assess performance has been developed. The ADC test framework includes both DSP (Digital Signal Processing) firmware and processing software. It is useful for low-level RF control and other synchronization projects. Investigating the clock jitter between two channels give us an understanding of that noise source. Working with the test framework, the raw ADC data are transferred to a computer through a Gigabit Ethernet interface. Then short-term error signal can be calculated based on a sine wave fit. By changing low-pass filter bandwidth, relative long-term performance can also be obtained. Amplitude jitter and differential phase jitter are the key issues for ADCs. This paper will report the test results for LTC2174 and AD9268 chips. The integral amplitude jitter is smaller than 0.003 %, and the integral phase noise is smaller than 0.0015° (measured at 47 MHz RF, 100 MHz clock, bandwidth 1 Hz to 100 kHz) for both ADC chips.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accelerating fissile material detection with a neutron source

A neutron detector system for discriminating fissile material from non-fissile material wherein a digital data acquisition unit collects data at high rate, and in real-time processes large volumes of data directly to count neutrons from the unknown source and detecting excess grouped neutrons to identify fission in the unknown source. The system includes a Poisson neutron generator for in-beam interrogation of a possible fissile neutron source and a DC power supply that exhibits electrical ripple on the order of less than one part per million. Certain voltage multiplier circuits, such as Cockroft-Walton voltage multipliers, are used to enhance the effective of series resistor-inductor circuits components to reduce the ripple associated with traditional AC rectified, high voltage DC power supplies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accelerating fissile material detection with a neutron source

A neutron detector system for discriminating fissile material from non-fissile material wherein a digital data acquisition unit collects data at high rate, and in real-time processes large volumes of data directly to count neutrons from the unknown source and detecting excess grouped neutrons to identify fission in the unknown source. The system includes a Poisson neutron generator for in-beam interrogation of a possible fissile neutron source and a DC power supply that exhibits electrical ripple on the order of less than one part per million. Certain voltage multiplier circuits, such as Cockroft-Walton voltage multipliers, are used to enhance the effective of series resistor-inductor circuits components to reduce the ripple associated with traditional AC rectified, high voltage DC power supplies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interconnection Standard Grid-Support Function Evaluations Using an Automated Hardware-in-the-Loop Testbed

Grid operators are increasingly turning to advanced grid-support functions in distributed energy resources (DER) to assist with distribution circuit voltage regulation, bulk system frequency control, and power system protection. The U.S. DER certification standard, Underwriters Laboratories (UL) 1741, was revised in September 2016 to add test procedures for multiple grid-support functions. Sandia National Laboratories, SunSpec Alliance, and growing community of collaborators have undertaken a multiyear effort to create an open-source system validation platform (SVP) that automates DER interconnection and interoperability test procedures by communicating with grid simulators, photovoltaic (PV) simulators, data acquisition systems, and interoperable equipment under test. However, the power hardware required for generating the test conditions may be untenable for many organizations. In this paper, we discuss development of the SVP testing capabilities for UL 1741 tests utilizing a controller hardware-in-the-loop testbed that precludes the need for power hardware using a 34.5 kW Austrian Institute of Technology smart grid controller. Finally, analysis of normal ramp rate, soft start ramp rate, specified power factor, volt-VAr, and frequency-watt advanced grid functions, and the effectiveness of the UL 1741 test protocols are included.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fault detection in PV systems

A practical fault detection approach for PV systems intended for online implementation is developed. The fault detection model here is built using artificial neural network. initially the photovoltaic system is simulated using MATLAB software and output power is collected for various combinations of irradiance and temperature. Data is first collected for normal operating condition and then four types of faults are simulated and data are collected for faulty conditions. Four faults are considered here and they are: Line to Line faults with a small voltage difference, Line to line faults with a large voltage difference, degradation fault and open-circuit fault. This data is then used to train the neural network and to develop the fault detection model. The fault detection model takes irradiance, temperature and power as the input and accurately gives the type of fault in the PV system as the output. This system is a generalized one as any PV module datasheet can be used to simulate the Photovoltaic system and also this fault detection system can be implemented online with the use of data acquisition system.

14 SOLAR ENERGY↗

Spatio-Temporal Anomaly Detection with Graph Networks for Data Quality Monitoring of the Hadron Calorimeter

The Compact Muon Solenoid (CMS) experiment is a general-purpose detector for high-energy collision at the Large Hadron Collider (LHC) at CERN. It employs an online data quality monitoring (DQM) system to promptly spot and diagnose particle data acquisition problems to avoid data quality loss. In this study, we present a semi-supervised spatio-temporal anomaly detection (AD) monitoring system for the physics particle reading channels of the Hadron Calorimeter (HCAL) of the CMS using three-dimensional digi-occupancy map data of the DQM. We propose the GraphSTAD system, which employs convolutional and graph neural networks to learn local spatial characteristics induced by particles traversing the detector and the global behavior owing to shared backend circuit connections and housing boxes of the channels, respectively. Recurrent neural networks capture the temporal evolution of the extracted spatial features. We validate the accuracy of the proposed AD system in capturing diverse channel fault types using the LHC collision data sets. The GraphSTAD system achieves production-level accuracy and is being integrated into the CMS core production system for real-time monitoring of the HCAL. We provide a quantitative performance comparison with alternative benchmark models to demonstrate the promising leverage of the presented system.

43 PARTICLE ACCELERATORS↗

The revolution in data gathering systems

This paper gives a review of the data-acquisition systems used in NASA's wind tunnels from the 1950's to the present as a basis for assessing the impact of minicomputers and microcomputers on data acquisition and processing. The operation and disadvantages of wind-tunnel data systems are summarized for the period before 1950, the early 1950's, the early and late 1960's, and the early 1970's. Some significant advances discussed include the use or development of solid-state components, minicomputer systems, large central computers, on-line data processing, autoranging DC amplifiers, MOS-FET multiplexers, MSI and LSI logic, computer-controlled programmable amplifiers, solid-state remote multiplexing, integrated circuits, and microprocessors. The distributed system currently in use with the 40-ft by 80-ft wind tunnel at Ames Research Center is described in detail. The expected employment of distributed systems and microprocessors in the next decade is noted.

Cambra, J. M.↗

A Frequency Domain Multiplexing Technique for Multi-Channel Detector Instrumentation

Radiation detection often requires several detectors to be employed at once. Normally, each detector outputs a signal that must be transported, digitized, and stored. One common format for these signals is a finite, aperiodic pulse. Since the detector and data acquisition system are not necessarily physically close, transporting signals from several detectors to a central data acquisition system often requires the use of many cables. The technique presented here allows for the combination and later recovery of a number of analog detector signals using a single cable, by shifting their content to narrow bands in the frequency domain and summing them together into a single channel for transmission. The output is a linear combination of decaying sinusoids, whose peak frequencies and bandwidths in the frequency domain are controlled by inductor, resistor, and capacitor values in the circuit. By separating the outputs by several megahertz, and lowering the bandwidth to about 1 MHz, we can isolate each signal. The timing of the original input can be recovered by taking the inverse Fourier transform of the isolated peak and identifying the start time of the resulting single decaying sinusoid. The energy of the input signal is proportional to the square root of the integral of the corresponding power spectrum peak. We show that energy spectra can be reconstructed with minimal additions to energy resolution. We also show that coincidence timing measurements can be performed with an uncertainty smaller than 2 ns. The result is an N to 1 reduction in cabling, with obvious cost and complexity gains. Since most of the signal content exists only in a band around each peak frequency, noise outside of these bands does not impact the performance.

Belling, Samuel↗

High-speed electromechanical chutter for imaging spectrographs

The present invention presents a high-speed electromechanical shutter which has at least two rotary beam choppers that are synchronized using a phase-locked loop electronic control to reduce the duty cycle. These choppers have blade means that can comprise discs or drums, each having about 60 (+/- 15) slots which are from about 0.3 to about 0.8 mm wide and about 5 to about 20 nun long (radially) which are evenly distributed through out 360 deg, and a third rotary chopper which is optically aligned has a small number of slots, such as for example, 1 to 10 slots which are about 1 to about 2 mm wide and about 5 to about 20 mm long (radially). Further the blade means include phase slots that allow the blade means to be phase locked using a closed loop control circuit. In addition, in a preferred embodiment, the system also has a leaf shutter. Thus the invention preferably achieves a gate width of less than about 100 microseconds, using motors that operate at 3000 to 10,OOO rpm, and with a phase jitter of less than about 1.5 microseconds, and further using an aperture with more than about 75% optical transmission with a clear aperture of about 0.8 -10 nun. The system can be synchronized to external sources at 0 6 kHz lasers, data acquisition systems, and cameras.

Quang-Viet Nguyen↗

Conductance measurement circuit with wide dynamic range

A conductance measurement circuit to measure conductance of a solution under test with an output voltage proportional to conductance over a 5-decade range, i.e., 0.01 uS to 1000 uS or from 0.1 uS to 10,000 uS. An increase in conductance indicates growth, or multiplication, of the bacteria in the test solution. Two circuits are used each for an alternate half-cycle time periods of an alternate squarewave in order to cause alternate and opposite currents to be applied to the test solution. The output of one of the two circuits may be scaled for a different range optimum switching frequency dependent upon the solution conductance and to enable uninterrupted measurement over the complete 5-decade range. This circuitry provides two overlapping ranges of conductance which can be read simultaneously without discontinuity thereby eliminating range switching within the basic circuitry. A VCO is used to automatically change the operating frequency according to the particular value of the conductance being measured, and comparators indicate which range is valid and also facilitate computer-controlled data acquisition. A multiplexer may be used to monitor any number of solutions under test continuously.

Mount, Bruce E.↗