Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data acquisition systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Portable High-Frequency Data-Acquisition System

Compact unit made of readily available solid-state components. Proposed system for acquisition of rapidly changing data self-contained and portable. Conceived for monitoring such aerodynamic effects as flutter, vibration, shock, sound, and pressure. Offers precise and fast acquisition of data and large data-storage capacity: has maximum sampling rate of 125 kHz, access time of 15 ns, and 1-million-bit memory. Measures time with "smart" (microprocessor-controlled) watch that maintains calendar time for more than 10 years without external power. Provides standby power from "smart" battery furnishing up to 1 ampere-hour of charge if power from main batteries lost.

Mustain, Roy W.↗

The IceCube data acquisition system: Signal capture, digitization,and timestamping

IceCube is a km-scale neutrino observatory under construction at the South Pole with sensors both in the deep ice (InIce) and on the surface (IceTop). The sensors, called Digital Optical Modules (DOMs), detect, digitize and timestamp the signals from optical Cherenkov-radiation photons. The DOM Main Board (MB) data acquisition subsystem is connected to the central DAQ in the IceCube Laboratory (ICL) by a single twisted copper wire-pair and transmits packetized data on demand. Time calibration ismaintained throughout the array by regular transmission to the DOMs of precisely timed analog signals, synchronized to a central GPS-disciplined clock. The design goals and consequent features, functional capabilities, and initial performance of the DOM MB, and the operation of a combined array of DOMs as a system, are described here. Experience with the first InIce strings and the IceTop stations indicates that the system design and performance goals have been achieved.

79 ASTRONOMY AND ASTROPHYSICS↗

Data Acquisition System for RF Cavity Hadron Monitor

As Fermilab pursues intensity frontier physics, the conventional detectors are not up to the challenge of higher radiation exposure. The detectors in the NuMI beamline rely on knowing the beam composition in order to infer properties of the resultant neutrino beam. Anovel gas-filled RF cavity beam detector is proposed that will be simple and radiation robust in high-radiation environments. Charged particles passing through the cavity produce ionized plasma, which changes the permittivity of the gas and modulate the stored RF field in the cavity. The recent preliminary beam result demonstrates the proof of principle of the beam detector. In an effort to acquire a large amount of data for various cavity parameters, an automatic data acquisition(DAQ)system is designed in LabVIEW. The DAQ system utilizes a Real-Time Power meter from Boonton to acquire RF power data from the cavity.

43 PARTICLE ACCELERATORS↗

Data Acquisition System for RF Cavity Hadron Monitor

As Fermilab pursues intensity frontier physics, the conventional detectors are not up to the challenge of higher radiation exposure. The detectors in the NuMI beamline rely on knowing the angular distribution of the secondary hadrons in order to infer properties of the resultant neutrino beam. A novel gas-filled RF cavity beam detector is proposed that will be simple and radiation robust in high-radiation environments. Charged particles passing through the cavity produce ionized plasma, which changes the permittivity of the gas and modulate the stored RF field in the cavity. The preliminary beam test of an RF cavity demonstrates the proof of principle of the beam detector. In an effort to acquire a large amount of data for various cavity parameters, an automatic data acquisition (DAQ) system is designed in LabVIEW. The DAQ system utilizes a Real-Time Power meter from Boonton to acquire RF power data from the cavity.

43 PARTICLE ACCELERATORS↗

Development and test of a mini-Data Acquisition system for the High-Luminosity LHC upgrade of the ATLAS Monitored Drift Tube detector

New front-end electronics including ASICs and FPGA boards are under development for the ATLAS Monitored Drift Tube (MDT) detector to handle the large data rates and harsh environment expected at high-luminosity LHC runs. A mobile Data Acquisition (miniDAQ) system is designed to perform integration tests of these front-end electronics. In addition, it will be used for surface commissioning of 96 small-radius MDT (sMDT) chambers and for integration and commissioning of new front-end electronics on the present ATLAS MDT chambers. Details of the miniDAQ hardware and firmware are described in this article. Here, the miniDAQ system is also used to read out new front-end electronics on an sMDT prototype chamber using cosmic muons and results obtained are shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The SciBooNE Data Acquisition System

SciBooNE started in June 2007 primarily to study neutrino and anti-neutrino interactions in the energy region below 1 GeV. The SciBooNE detector is located in Booster Neutrino Beamline at Fermi National Accelerator Laboratory. The SciBooNE data aquisition system consists of the readout software and an event builder, which collects data from each detector component (SciBar detector, an electromagnetic calorimeter, Muon Range Detector and GPS). The typical DAQ readout time per trigger is 20 ms, which is fast enough to take every beam spill. The system is also very stable and the probability of missing a beam spill due to the readout time is less than 0.002 %.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrade of the CAESium-iodide scintillator ARray (CAESAR) electronics and data acquisition system for optimized performance at FRIB

Here, we report on the upgrade of the electronics and data acquisition (DAQ) of the high-efficiency CAESium-iodide scintillator ARray (CAESAR) at the Facility for Rare Isotope Beams (FRIB). With the on-going capability ramp-up of FRIB, CAESAR is expected to continue to be an in-demand -ray spectrometer owing to its high detection efficiency, compactness, and modularity, enabling easy integration with additional detection and DAQ systems. Within this context, the CAESAR electronics and DAQ were upgraded to remove obsolete modules, enhance the ease of integration with external instruments, and optimize the DAQ live time. We present the comprehensive results from offline (γ-ray sources) and online (in-beam experiment) commissioning, characterizing the performance of CAESAR’s new electronics and DAQ.

CsI(Na) scintillator array↗

Data acquisition system for NASA LaRC impact dynamics research facility

A data system is designed to permit the simultaneous recording of 90 data channels on one 28 track magnetic tape recorder using a constant bandwidth FM multiplexing technique. Dynamic signals from transducers located in the test aircraft are amplified and fed to voltage controlled oscillators where they are converted to discrete FM signals. The signals from each group of five VCO's are fed to a mixer/distribution amplifier where they are combined into one composite signal and recorded, using direct recording techniques, on one magnetic tape recorder track. Millivolt signals from the recorders reproduce heads are amplified to one volt and then electronically switched to an FM demultiplexing system where appropriate frequency discrimination and signal filtering recover the original analog information.

Mccormick, R. F.↗

Calibration of a compact ASIC-based data acquisition system for neutron/$γ$ discrimination and spectroscopy with organic scintillators

Segmented neutron detectors that use silicon photomultipliers (SiPMs) are receiving significant attention in nuclear security applications. Some of these detectors employ hundreds of channels and would therefore benefit from the use of high-channel-density and low-cost-per-channel data acquisition (DAQ) systems. Candidate DAQ systems that meet these requirements exist, but few perform full waveform digitization, which permits neutron and gamma-ray interaction discrimination via pulse shape. In this work, we study the performance of the TOFPET2 (PETsys Electronics), an ASIC-based DAQ designed for positron emission tomography, which has been adapted to provide sensitivity to pulse shape by the use of variable-period charge integration. We use a light-emitting diode to calibrate a combination of an ON Semiconductor (SensL) 60035-64P J-Series SiPM and TOPFET2 DAQ and evaluate the linearity of their response and dynamic range. Here, the calibration curve was obtained by comparing the DAQ response to that measured with a photodiode interfaced with a traditional waveform digitizer. This calibration process was used for rudimentary spectroscopy of various neutron and sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast integrator based data acquisition system for the SST-1 Thomson scattering system

An operational transconductance amplifier based fast charge-integrating module (FCIM) is designed and developed for an easy acquisition of fast Thomson scattered and background signal. FCIM based data acquisition technique can be used for the measurement of charge pulses of <20 ns duration. The response of the module is tested using a standard pulsed charge-generating module. The measuring charge range of the module depends on the integrating capacitor. Comparison of the performance of FCIM to commercially available module shows that it has better dynamic range with higher sensitivity and less measurement error. The module is quite cost effective and has many new features.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A faster and more reliable data acquisition system for the full performance of the SciCRT

The SciBar Cosmic Ray Telescope (SciCRT) is a massive scintillator tracker to observe cosmic rays at a very high-altitude environment in Mexico. The fully active tracker is based on the Scintillator Bar (SciBar) detector developed as a near detector for the KEK-to-Kamioka long-baseline neutrino oscillation experiment (K2K) in Japan. Since the data acquisition (DAQ) system was developed for the accelerator experiment, we determined to develop a new robust DAQ system to optimize it to our cosmic-ray experiment needs at the top of Mt. Sierra Negra (4600 m). One of our special requirements is to achieve a 10 times faster readout rate. We started to develop a new fast readout back-end board (BEB) based on 100 Mbps SiTCP, a hardware network processor developed for DAQ systems for high energy physics experiments. Then we developed the new BEB which has a potential of 20 times faster than the current one in the case of observing neutrons. Lastly, we installed the new DAQ system including the new BEBs to a part of the SciCRT in July 2015. The system has been operating since then. In this article, we describe the development, the basic performance of the new BEB, the status after the installation in the SciCRT, and the future performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flow visualization using a computerized data acquisition system

A computer-driven traversing mechanism combined with mass data storage, data reduction programs, and general-purpose graphics programs permits a visualization of complex flows. A unique seven-hole probe is used which permits reasonably accurate measurements of all average flow properties if the local flow angle does not exceed 80 degrees. A description is given of the wake of a lifting canard surface as this wake passes over a wing. The flow includes concentrated and dissipating vortices, large regions of reduced total pressure, and local flow angles up to 60 deg. All these features can be clearly seen and accurately located in the graphical output.

Gallington, R.↗

A scaler-based data acquisition system for measuring parity-violating asymmetry in deep inelastic scattering

An experiment that measured the parity violating asymmetries in deep inelastic scattering was completed at the Thomas Jefferson National Accelerator Facility in experimental Hall A. From these asymmetries, a combination of the quark weak axial charge could be extracted with a factor of five improvement in precision over world data. To achieve this, asymmetries at the 10^-4 level needed to be measured at event rates up to 500 kHz and the high pion background typical to deep inelastic scattering experiments needed to be rejected efficiently. A specialized data acquisition (DAQ) system with intrinsic particle identification (PID) was successfully developed and used: The pion contamination in the electron samples was controlled at the order of 2 × 10^-4 or below with an electron efficiency of higher than 91% throughout the production period of the experiment, the systematic uncertainty in the measured asymmetry due to DAQ deadtime was below 0.2%, and the statistical quality of the asymmetry measurement agreed with the Gaussian distribution to over five orders of magnitudes. The DAQ system is presented here with an emphasis on its design scheme, the achieved PID performance, deadtime effect and the capability of measuring small asymmetries.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A fast data acquisition system for the study of transient events by high repetition rate time-of-flight mass spectrometry

Recent advances in commercially available data acquisition electronics embodying high speed A/D conversion coupled to increased memory storage have now made practical (at least within time intervals of a third of a millisecond or more) the capturing of all of the data generated by a high repetition rate time-of-flight mass spectrometer producing complete spectra every 25 to 35 microseconds. Such a system was assembled and interfaced with a personal computer for control and management of data. The applications are described for recording time-resolved spectra of individual vapor plumes induced from the pulsed-laser heating of material. Each laser pulse triggers the system to generate automatically a 3-dimensional (3-D) presentation of the time-resolved spectra with m/z labeling of the major mass peaks, plus an intensity versus time display of both the laser pulse and the resulting vapor pulse. The software also permits storing of data and its presentation in various additional forms.

Lincoln, K. A.↗

Armstrong Flight Research Center Flight Test Capabilities and Opportunities for the Applications of Wireless Data Acquisition Systems

The presentation will overview NASA Armstrong Flight Research Centers flight test capabilities, which can provide various means for flight testing of passive and active wireless sensor systems, also, it will address the needs of the wireless data acquisition solutions for the centers flight instrumentation issues such as additional weight caused by added instrumentation wire bundles, connectors, wire cables routing, moving components, etc., that the Passive Wireless Sensor Technology Workshop may help. The presentation shows the constraints and requirements that the wireless sensor systems will face in the flight test applications.

flight tests↗

Snowmass Topical Group Summary Report: IF04 -- Trigger and Data Acquisition Systems

A trend for future high energy physics experiments is an increase in the data bandwidth produced from the detectors. Datasets of the Petabyte scale have already become the norm, and the requirements of future experiments -- greater in size, exposure, and complexity -- will further push the limits of data acquisition technologies to data rates of exabytes per seconds. The challenge for these future data-intensive physics facilities lies in the reduction of the flow of data through a combination of sophisticated event selection in the form of high-performance triggers and improved data representation through compression and calculation of high-level quantities. These tasks must be performed with low-latency (i.e. in real-time) and often in extreme environments including high radiation, high magnetic fields, and cryogenic temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Snowmass Topical Group Summary Report: IF04 -- Trigger and Data Acquisition Systems

A trend for future high energy physics experiments is an increase in the data bandwidth produced from the detectors. Datasets of the Petabyte scale have already become the norm, and the requirements of future experiments -- greater in size, exposure, and complexity -- will further push the limits of data acquisition technologies to data rates of exabytes per seconds. The challenge for these future data-intensive physics facilities lies in the reduction of the flow of data through a combination of sophisticated event selection in the form of high-performance triggers and improved data representation through compression and calculation of high-level quantities. These tasks must be performed with low-latency (i.e. in real-time) and often in extreme environments including high radiation, high magnetic fields, and cryogenic temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗