Search NASA⌕ Search

SEARCH · Search NASA

Results for “Design pattern”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

WE-EF-303-03: A New Aperture-Based Imaging System for Prompt-Gamma Range Verification of Proton Beam Therapy

Purpose: To develop and characterize a novel aperture-based imaging system for high-energy gamma-rays. This collimated system will provide 2-dimensional imaging capability for verification of proton beam range and Bragg peak dose via prompt-gamma detection. Methods: A multi-knife-edge slit collimator has been designed, constructed, and characterized via simulations and experimental measurements. The 20×20×7.5 cm{sup 3} tungsten collimator and accompanying LSO scintillation detector were simulated using the TOPAS Geant4 -based Monte Carlo package. Iterative reconstruction methods were combined with point response functions to characterize the imaging performance of the system. The response of the system has begun to be characterized experimentally as well, using 2.6 MeV gamma-rays from Th-228. Results: Both simulation and experimental results indicate that this collimated system provides 2-D imaging capability in the energy range of interest for prompt-gamma dose verification. In the current configuration, with collimator to source distance of 13 cm, image reconstruction of point sources resulted in spatial resolution (FWHM) of approximately 4 mm in both x-and y-directions in the imaging plane. The accuracy of positioning the point sources is less than 1 mm. Conclusion: This work has characterized, via simulation and measurements, a novel multi-knife-edge slit collimator in front of a more conventional position-sensitive LSO scintillator detector. The multi-slit pattern is designed to increase detection efficiency and provide spatial information in 2-dimensions -- an improvement over a single-slit collimator design. The thickness and density of the collimator will allow this detection system to perform well in an environment with high gamma flux, while ultimately providing peak determination accuracy on the order of 1 mm. This material is based upon work supported by the Department of Energy National Nuclear Security Administration under Award Number: DE-NA0000979 through the Nuclear Science and Security Consortium.

60 APPLIED LIFE SCIENCES↗

Expert Consensus Contouring Guidelines for Intensity Modulated Radiation Therapy in Esophageal and Gastroesophageal Junction Cancer

Purpose/Objective(s): Current guidelines for esophageal cancer contouring are derived from traditional 2-dimensional fields based on bony landmarks, and they do not provide sufficient anatomic detail to ensure consistent contouring for more conformal radiation therapy techniques such as intensity modulated radiation therapy (IMRT). Therefore, we convened an expert panel with the specific aim to derive contouring guidelines and generate an atlas for the clinical target volume (CTV) in esophageal or gastroesophageal junction (GEJ) cancer. Methods and Materials: Eight expert academically based gastrointestinal radiation oncologists participated. Three sample cases were chosen: a GEJ cancer, a distal esophageal cancer, and a mid-upper esophageal cancer. Uniform computed tomographic (CT) simulation datasets and accompanying diagnostic positron emission tomographic/CT images were distributed to each expert, and the expert was instructed to generate gross tumor volume (GTV) and CTV contours for each case. All contours were aggregated and subjected to quantitative analysis to assess the degree of concordance between experts and to generate draft consensus contours. The panel then refined these contours to generate the contouring atlas. Results: The κ statistics indicated substantial agreement between panelists for each of the 3 test cases. A consensus CTV atlas was generated for the 3 test cases, each representing common anatomic presentations of esophageal cancer. The panel agreed on guidelines and principles to facilitate the generalizability of the atlas to individual cases. Conclusions: This expert panel successfully reached agreement on contouring guidelines for esophageal and GEJ IMRT and generated a reference CTV atlas. This atlas will serve as a reference for IMRT contours for clinical practice and prospective trial design. Subsequent patterns of failure analyses of clinical datasets using these guidelines may require modification in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Structure Activity Relationship Approach toward the Improved Separation of Rare-Earth Elements Using Diglycolamides

The separation of adjacent lanthanides continues to be a challenge worldwide because of the similar physical and chemical properties of these elements and a necessity to advance the use of clean-energy applications. In this paper, a systematic structure–performance relationship approach toward understanding the effect of N-alkyl group characteristics in diglycolamides (DGAs) on the separation of lanthanides(III) from a hydrochloric acid medium is presented. In addition to the three most extensively studied DGA complexants [N,N,N',N'-tetra(n-octyl)diglycolamide, TODGA; N,N,N',N'-tetra(2-ethylhexyl)diglycolamide, TEHDGA; N,N'-dimethyl-N,N'-di(n-octyl)diglycolamide, DMDODGA], 12 new extracting agents with varying substitution patterns were designed to study the interplay of steric and electronic effects that control rare-earth element extraction. Subtle changes in the structure around diglycolamide carbonyl oxygen atoms result in dramatic shifts in the lanthanide extraction strength and selectivity. The effects of the chain length and branching position of N-alkyl substituents in DGAs are elaborated on with the use of experimental, computational, and solution-structure characterization techniques.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Programmable nanowrinkle-induced room-temperature exciton localization in monolayer WSe2

Abstract Localized states in two-dimensional (2D) transition metal dichalcogenides (TMDCs) have been the subject of intense study, driven by potential applications in quantum information science. Despite the rapidly growing knowledge surrounding these emitters, their microscopic nature is still not fully understood, limiting their production and application. Motivated by this challenge, and by recent theoretical and experimental evidence showing that nanowrinkles generate strain-localized room-temperature emitters, we demonstrate a method to intentionally induce wrinkles with collections of stressors, showing that long-range wrinkle direction and position are controllable with patterned array design. Nano-photoluminescence (nano-PL) imaging combined with detailed strain modeling based on measured wrinkle topography establishes a correlation between wrinkle properties, particularly shear strain, and localized exciton emission. Beyond the array-induced wrinkles, nano-PL spatial maps further reveal that the strain environment around individual stressors is heterogeneous due to the presence of fine wrinkles that are less deterministic. At cryogenic temperatures, antibunched emission is observed, confirming that the nanocone-induced strain is sufficiently large for the formation of quantum emitters. At 300 K, detailed nanoscale hyperspectral images uncover a wide range of low-energy emission peaks originating from the fine wrinkles, and show that the states can be tightly confined to regions <10 nm, even in ambient conditions. These results establish a promising potential route towards realizing room temperature quantum emission in 2D TMDC systems.

36 MATERIALS SCIENCE↗

Enhancement of phonon backscattering due to confinement of ballistic phonon pathways in silicon as studied with a microfabricated phonon spectrometer

In this work, the mechanism for enhanced phonon backscattering in silicon is investigated. An understanding of phonon propagation through substrates has implications for engineering heat flow at the nanoscale, for understanding sources of decoherence in quantum systems, and for realizing efficient phonon-mediated particle detectors. In these systems, phonons that backscatter from the bottom of substrates, within the crystal or from interfaces, often contribute to the overall detector signal. We utilize a microscale phonon spectrometer, comprising superconducting tunnel junction emitters and detectors, to specifically probe phonon backscattering in silicon substrates (∼500 μm thick). By etching phonon “enhancers” or deep trenches (∼90 μm) around the detectors, we show that the backscattered signal level increases by a factor of ∼2 for two enhancers versus one enhancer. Using a geometric analysis of the phonon pathways, we show that the mechanism of the backscattered phonon enhancement is due to confinement of the ballistic phonon pathways and increased scattering off the enhancer walls. Our result is applicable to the geometric design and patterning of substrates that are employed in phonon-mediated detection devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Anderson localization of graphene by helium ion irradiation

Irradiation of a single-layer graphene (SLG) with accelerated helium ions (He{sup +}) controllably generates defect distributions, which create a charge carrier scattering source within the SLG. We report direct experimental observation of metal-insulator transition in SLG on SiO{sub 2}/Si substrates induced by Anderson localization. This transition was investigated using scanning capacitance microscopy by monitoring the He{sup +} dose conditions on the SLG. The experimental data show that a defect density of more than ∼1.2% induced Anderson localization. We also investigated the localization length by determining patterned placement of the defects and estimated the length to be several dozen nanometers. These findings provide valuable insight for patterning and designing graphene-based nanostructures using helium ion microscopy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An interaction scenario of the galaxy pair NGC 3893/96 (KPG 302): A single passage?

Using the data obtained previously from Fabry-Perot interferometry, we study the orbital characteristics of the interacting pair of galaxies KPG 302 with the aim to estimate a possible interaction history, the conditions necessary for the spiral arm formation, and initial satellite mass. We found by performing N-body/smoothed particle hydrodynamics simulations of the interaction that a single passage can produce a grand design spiral pattern in less than 1 Gyr. Although we reproduce most of the features with the single passage, the required satellite to host mass ratio should be ∼1:5, which is not confirmed by the dynamical mass estimate made from the measured rotation curve. We conclude that a more realistic interaction scenario would require several passages in order to explain the mass ratio discrepancy.

79 ASTRONOMY AND ASTROPHYSICS↗

TES development for a frequency selective bolometer camera.

We discuss the development, at Argonne National Laboratory (ANL), of a four-pixel camera with four spectral channels centered at 150, 220, 270, and 360 GHz. The scientific motivation involves photometry of distant dusty galaxies located by Spitzer and SCUBA, as well as the study of other millimeter-wave sources such as ultra-luminous infrared galaxies, the Sunyaev-Zeldovich effect in clusters, and galactic dust. The camera incorporates Frequency Selective Bolometer (FSB) and superconducting Transition-Edge Sensor (TES) technology. The current generation of TES devices we examine utilizes proximity effect superconducting bilayers of Mo/Au, Ti, or Ti/Au as TESs, located along with frequency selective absorbing structures on silicon nitride membranes. The detector incorporates lithographically patterned structures designed to address both TES device stability and detector thermal transport concerns. The membrane is not perforated, resulting in a detector which is comparatively robust mechanically. In this paper, we report on the development of the superconducting bilayer TES technology, the design and testing of the detector thermal transport and device stability control structures, optical and thermal test results, and the use of new materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Direct fabrication of high aspect-ratio metal oxide nanopatterns via sequential infiltration synthesis in lithographically defined SU-8 templates

Nanopatterning high aspect-ratio metal oxide structures remains challenging for conventional nanofabrication methods based on reactive ion etching due to marginal etch selectivity between target oxides and typical mask materials. Here, the authors report the application of sequential infiltration synthesis (SIS) on lithographically defined SU-8 polymer templates for patterning arbitrarily designed, high aspect-ratio metal oxide nanostructures with sub-50 nm linewidths, smooth vertical profiles, and three-dimensional (3D) morphologies difficult to achieve by the conventional fabrication methods. As examples, various AlOx nanostructures with ∼40 nm linewidths and up to 16 aspect ratios were demonstrated, along with TiOx in-plane nanowire arrays of controlled positional registrations. Detailed scanning and transmission electron microscopy studies revealed nanocrystalline and amorphous internal structures of respective AlOx and TiOx, as well as the swelling and contraction behaviors of polymer templates during the SIS process, which allowed the facile fabrication of high aspect-ratio, sub-50 nm-featured oxide nanopatterns with 3D morphologies. These results confirm the potential of vapor-phase material infiltration in directly nanopatterning complexly structured metal oxides.

Nam, Chang-Yong↗

Motion as a perturbation: Measurement-guided dose estimates to moving patient voxels during modulated arc deliveries

Purpose: To present a framework for measurement-guided VMAT dose reconstruction to moving patient voxels from a known motion kernel and the static phantom data, and to validate this perturbation-based approach with the proof-of-principle experiments. Methods: As described previously, the VMAT 3D dose to a static patient can be estimated by applying a phantom measurement-guided perturbation to the treatment planning system (TPS)-calculated dose grid. The fraction dose to any voxel in the presence of motion, assuming the motion kernel is known, can be derived in a similar fashion by applying a measurement-guided motion perturbation. The dose to the diodes in a helical phantom is recorded at 50 ms intervals and is transformed into a series of time-resolved high-density volumetric dose grids. A moving voxel is propagated through this 4D dose space and the fraction dose to that voxel in the phantom is accumulated. The ratio of this motion-perturbed, reconstructed dose to the TPS dose in the phantom serves as a perturbation factor, applied to the TPS fraction dose to the similarly situated voxel in the patient. This approach was validated by the ion chamber and film measurements on four phantoms of different shape and structure: homogeneous and inhomogeneous cylinders, a homogeneous cube, and an anthropomorphic thoracic phantom. A 2D motion stage was used to simulate the motion. The stage position was synchronized with the beam start time with the respiratory gating simulator. The motion patterns were designed such that the motion speed was in the upper range of the expected tumor motion (1-1.4 cm/s) and the range exceeded the normally observed limits (up to 5.7 cm). The conformal arc plans for X or Y motion (in the IEC 61217 coordinate system) consisted of manually created narrow (3 cm) rectangular strips moving in-phase (tracking) or phase-shifted by 90 Degree-Sign (crossing) with respect to the phantom motion. The XY motion was tested with the computer-derived VMAT MLC sequences. For all phantoms and plans, time-resolved (10 Hz) ion chamber dose was collected. In addition, coronal (XY) films were exposed in the cube phantom to a VMAT beam with two different starting phases, and compared to the reconstructed motion-perturbed dose planes. Results: For the X or Y motions with the moving strip and geometrical phantoms, the maximum difference between perturbation-reconstructed and ion chamber doses did not exceed 1.9%, and the average for any motion pattern/starting phase did not exceed 1.3%. For the VMAT plans on the cubic and thoracic phantoms, one point exhibited a 3.5% error, while the remaining five were all within 1.1%. Across all the measurements (N = 22), the average disagreement was 0.5 {+-} 1.3% (1 SD). The films exhibited {gamma}(3%/3 mm) passing rates {>=}90%. Conclusions: The dose to an arbitrary moving voxel in a patient can be estimated with acceptable accuracy for a VMAT delivery, by performing a single QA measurement with a cylindrical phantom and applying two consecutive perturbations to the TPS-calculated patient dose. The first one accounts for the differences between the planned and delivered static doses, while the second one corrects for the motion.

60 APPLIED LIFE SCIENCES↗

SU-E-T-453: Image-Guided Patient-Specific Quality Assurance for Multi-Target Single Isocenter Intracranial VMAT Radiosurgery

Purpose: To demonstrate a patient specific, image-guided quality assurance method that tests both dosimetric and geometric accuracy for single-isocenter multiple-target VMAT radiosurgery (SIMT-VMAT-SRS) Method: We used a new film type, EBT-XD (optimal range 0.4–40Gy), and an in-house PMMA phantom having a coronal plane for film and a 0.125 cm3 ionization chamber (IC). The phantom contained fiducial features for kV image guided setup and for accurate film marking. Five patient plans with multiple targets sizes ranging from 3 to 21mm in diameter and prescribed doses from 14 to 18 Gy were selected. Two verification plans were generated for each case with the film plane passing through the center of the largest and smallest targets. For the four largest targets we obtained an IC measurement. For each case, a calibration film was irradiated using a custom designed step pattern. The films were scanned using a flatbed color scanner and converted to dose using the calibration film and the three channel calibration method. Image registration was performed between film and treatment planning system calculations to evaluate the geometric accuracy. Results: The mean registration vector had an average magnitude of 0.47 mm (range from 0.13mm to 0.64 mm). For the four largest targets, the mean ratio of the IC and film measurement to expected dose was 0.990 (range 0.968 to 1.009) and 1.032 (1.021 to 1.046), respectively. The fraction of pixels having gamma index < 1 for criteria of 3%/3mm, 3%/2mm, 3%/1mm was 98.8%, 97.5% and 87.2% before geometric registration and 99.1%, 98.3% and 94.8% after registration. Conclusion: We have demonstrated an image-guided QA method can assess both geometric and dosimetric accuracy. The phantom was positioned with sub-millimeter accuracy. Absolute film dosimetry using EBT-XD film was sufficiently accurate for assessment of dose to multi-targets too small for IC measurement in SRS VMAT plans.

60 APPLIED LIFE SCIENCES↗

ObstacleSense: Low-Power Neuromorphic Vision for Corridor Obstacle Awareness in Low-Level ADAS

The automotive industry’s pursuit of Level 5 autonomy is constrained by substantial perception-compute power requirements, often reaching 1, 000 + watts in full autonomy stacks. Reducing this energy burden requires rethinking perception not only at the high-end autonomy level, but also at the foundational Advanced Driver Assistance Systems (ADAS) level where low-power, safety-critical sensing can have broad impact. Neuromorphic vision provides a promising starting point: HD Dynamic Vision Sensors (DVS) can operate below 100 mW at the sensor level by reporting only asynchronous brightness changes. However, low-power sensing alone is insufficient if downstream perception reintroduces dense, energy-intensive computation. In particular, many event-driven object-detection pipelines still rely on CNN backbones, while purely spiking alternatives often trade away accuracy or ignore deployment constraints. We introduce ObstacleSense, a highly compact, CNN-free hybrid ANN–SNN framework for Level 0–1 forward-corridor obstacle awareness. Instead of performing full-scene object detection with a convolutional feature backbone, ObstacleSense targets the safety-critical question of whether the ego corridor is occupied and how far the nearest obstacle is. The architecture combines polarity-conditioned event encoding, lightweight temporal spiking dynamics, axial spatial mixing, and coarse-to-fine range estimation within a regular fixed-grid compute pattern. This design avoids the dense CNN backbone commonly used in event-based detection while maintaining a small state footprint suitable for eventual small-FPGA deployment. Before hardware mapping, we evaluate the software implementation using a model-side power proxy derived from MACs, weight and activation traffic, and spiking state updates under shared FP16 assumptions. On simulated CARLA event corpora, the deployment-oriented model achieves 0.9464 objectness F1, 0.9978 grid-level mAP, and 0.8987 m distance Mean Absolute Error at an estimated 1.92 mW proxy cost, while maintaining performance on unseen generalization test sequences.

Johnson-Scott, Zac [ORNL]↗

Single Pass Laser Process for Super-Hydrophobic Flexible Surfaces with Micro/Nano Hierarchical Structures

Wetting has been studied in various fields: chemical industry, automobile manufacturing, food companies, and even life sciences. In these studies, super-hydrophobic surfaces have been achieved through complex steps and processes. To realize super-hydrophobicity, however, we demonstrated a simple and single pass laser process for the fabrication of micro/nano hierarchical structures on the flexible polytetrafluoroethylene (PTFE, Teflon) surface. The fabricated hierarchical structures helped increase the hydrophobicity by augmenting the surface roughness and promoting air-trapping. In addition, we employed a low-cost and high-throughput replication process producing numerous polydimethylsiloxane (PDMS) replicas from the laser-processed PTFE film. Thanks to the anti-adhesive characteristics of PTFE and the elasticity of PDMS, the structure perfectly transferred to the replica without any mechanical failure. Moreover, our designed mesh patterns offered the possibility of large area applications through varying the process parameters (pitch, beam spot size, laser fluence, and scan speed). Even though mesh patterns had relatively large pitch (190 μm), we were able to achieve high contact angle (>150°). Through pneumatically deformed structure, we clearly showed that the shape of the droplets on our laser-processed super-hydrophobic surface was spherical. Based on these outcomes, we can expect our single laser pulse exposure process can overcome many drawbacks and offer opportunities for advancing applications of the wetting phenomena.

36 MATERIALS SCIENCE↗

Acoustic lens is gas-filled

Fluorocarbon gas contained by plastic membrane is effective lens for sound waves. In tests, lens substantially improved accuracy of sound "maps" of turbulent airflow. It could also be used to record sound intensity patterns in design of speakers, lecture halls, and auditoriums. Lens is fabricated by clamping together two membranes of thin plastic and filling enclosed space with fluorocarbon gas. Since speed of sound in gas is considerably less than in air, lens refracts and focuses sound waves, analogous to focusing light by glass lens. Focal length is adjusted simply by changing gas pressure, which changes lens curvature.

Kendall, J. M., Jr.↗

Small Gas Turbine Combustor Primary Zone Study

The combustion research program, small gas turbine combustor primary zone study is summarized. The basic elements of a design methodology program to obtain the maximum performance potential of small reverse-flow annular combustors is described. Three preferred combustion design approaches for internal flame stabilization patterns were selected. Design features are incorporated in the combustors to address the performance limiting problem areas associated with smaller annular combustors. Performance is predicted by using a 3-D aerodynamic/chemical kinetic elliptic flow analysis, initially developed by Garrett Corporation for the USARTL. It is shown that the analytical flow field predictive models provide a useful design tool for understanding the combustion performance of a small reverse flow annular combustor.

Sullivan, R. E.↗

Design and performance of a high-Tc superconductor coplanar waveguide filter

The design of a coplanar waveguide low-pass filter made of YBa2Cu3O(7-delta) (YBCO) on an LaAlO3 substrate is described. Measurements were incorporated into simple models for microwave CAD analysis to develop a final design. The patterned and packaged coplanar waveguide low-pass filter of YBCO, with dimensions suited for integrated circuits, exhibited measured insertion losses when cooled in liquid nitrogen superior to those of a similarly cooled thin-film copper filter throughout the 0 to 9.5 GHz passband. Coplanar waveguide models for use with thin-film normal metal (with thickness either greater or less than the skin depth) and YBCO are discussed and used to compare the losses of the measured YBCO and copper circuits.

Chew, Wilbert↗