Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diagnostic Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Imaging velocity interferometer system for any reflector (VISAR) diagnostics for high energy density sciences

Two variants of optical imaging velocimetry, specifically the one-dimensional streaked line-imaging and the two-dimensional time-resolved area-imaging versions of the Velocity Interferometer System for Any Reflector (VISAR), have become important diagnostics in high energy density sciences, including inertial confinement fusion and dynamic compression of condensed matter. Here, we give a brief review of the historical development of these techniques, then describe the current implementations at major high energy density (HED) facilities worldwide, including the OMEGA Laser Facility and the National Ignition Facility. We illustrate the versatility and power of these techniques by reviewing diverse applications of imaging VISARs for gas-gun and laser-driven dynamic compression experiments for materials science, shock physics, condensed matter physics, chemical physics, plasma physics, planetary science and astronomy, as well as a broad range of HED experiments and laser-driven inertial confinement fusion research.

47 OTHER INSTRUMENTATION↗

Fiber-Based Multi-Resolution Imaging and Multidimensional X-ray Diagnostics for Ejecta Dynamics in Plume Surface Interactions

The interaction of a rocket exhaust plume with a particulate-laden surface creates a complex, multiphase flow field that can destabilize the vehicle and damage nearby equipment. This study investigates two methods for capturing the particulate dynamics of plume-surface interaction (PSI): optical fiber-based multi-resolution Mie scattering and multi-dimensional X-ray radiography. Mie scattering was used to track PSI-interacted particles, trace their paths, and measure velocities. While effective for the jet periphery and early PSI stages, the technique becomes limited as the scattering cross-section increases over time due to particle displacement from the soil bed, causing the core to become optically dense and appear as a luminous, opaque region. To address this, X-ray radiography was explored as a complementary method for visualizing the optically dense core. PSI experiments were conducted with both reacting and non-reacting jets to evaluate these approaches across a range of optical and flow parameters. The results demonstrated the capability of the fiber-based multi-resolution imaging system to capture simultaneous fields of view at varying magnifications (1x, 2x, 4x), and the ability of X-ray imaging to penetrate the optically dense plume, revealing flow structures that would otherwise be obscured in scattering-based methods. Data were collected for various PSI parameters, including three different heights above the surface, to analyze the ejecta properties and the plume’s temporal evolution. These results provide the first imaging strategy capable of resolving flow structures over a wide spatial dynamic range while also offering the first visualization of the optically dense core.

Ejecta↗

Path-Integrated Stereo X-Ray Digital Image Correlation: Resolving the Violation of Conservation of Intensity

In this study, x-ray imaging addresses many challenges with visible light imaging in extreme environments, where optical diagnostics such as digital image correlation (DIC) and particle image velocimetry (PIV) suffer biases from index of refraction changes and/or cannot penetrate visibly occluded objects. However, conservation of intensity—the fundamental principle of optical image correlation algorithms—may be violated if ancillary components in the X-ray path besides the surface or fluid of interest move during the test. The test series treated in this work sought to characterize the safe use of fiber-epoxy composites in aerospace and aviation industries during fire accident scenarios. Stereo X-ray DIC was employed to measure test unit deformation in an extreme thermal environment involving a visibly occluded test unit, incident surface heating to temperatures above 600°C, and flames and soot from combusting epoxy decomposition gasses. The objective of the current work is to evaluate two solutions to resolve the violation of conservation of intensity that resulted from both the test unit and the thermal chamber deforming during the test. The first solution recovered conservation of intensity by pre-processing the path-integrated X-ray images to isolate the DIC pattern of the test unit from the thermal chamber components. These images were then correlated with standard, optical DIC software. The second solution, called Path-Integrated Digital Image Correlation (PI-DIC), modified the fundamental matching criterion of DIC to account for multiple, independently-moving components contributing to the final image intensity. The PI-DIC algorithm was extended from a 2D framework to a stereo framework and implemented in a custom DIC software. Both solutions accurately measured the cylindrical shape of the undeformed test unit, recovering radii values of R = 76.20±0.12 mm compared to the theoretical radius of R theor = 76.20 mm. During the test, the test unit bulged asymmetrically as decomposition gasses pressurized the interior and eventually burned in a localized jet. Both solutions measured the heterogeneous radius of this bulge, which reached a maximum of approximately R = 91 mm, with a discrepancy of 2–3% between the two solutions. Two solutions that resolve the violation of conservation of intensity for path-integrated X-ray images were developed. Both were successfully employed in a stereo X-ray DIC configuration to measure deformation of an aluminum-skinned, fiber-epoxy composite test unit in a fire accident scenario.

47 OTHER INSTRUMENTATION↗

NucD-23 Nuclear Diagnostics Development: The future of neutron imaging and gamma reaction history

The Neutron Imaging team has deployed novel, active detection systems along two lines of sight at NIF. Studies aimed to characterize NIS sensitivity to implosion shape will be carried out to further extend reconstruction capabilities. Additionally, an improved camera timing system that will reduce uncertainties stemming from bang time jitter will also be fielded. The NIF GRH data recording system is more then 10 years old needs to be updated. Bandwidth and noise are a key limiting factor for improving data quality. New high bandwidth and low noise components will be tested at OMEGA in advance before fielding the components at NIF.

42 ENGINEERING↗

X-ray phase-contrast imaging of strong shocks on OMEGA EP

The ongoing improvement in laser technology and target fabrication is opening new possibilities for diagnostic development. An example is x-ray phase-contrast imaging (XPCI), which serves as an advanced x-ray imaging diagnostic in laser-driven experiments. In this work, we present the results of the XPCI platform that was developed at the OMEGA EP Laser-Facility to study multi-Mbar single and double shocks produced using a kilojoule laser driver. Two-dimensional radiation-hydrodynamic simulations agree well with the shock progression and the spherical curvature of the shock fronts. It is demonstrated that XPCI is an excellent method to determine with high accuracy the front position of a trailing shock wave propagating through an expanding CH plasma that was heated by a precursor Mbar shock wave. Furthermore, the interaction between the rarefaction wave and the shock wave results in a clear signature in the radiograph that is well reproduced by radiation-hydrodynamic simulations.

47 OTHER INSTRUMENTATION↗

Image processing methods for Rayleigh scattering measurements of diesel spray mixing at high repetition rate

This work describes the diagnostic implementation and image processing methods to quantitatively measure diesel spray mixing injected into a high-pressure, high-temperature environment. We used a high-repetition-rate pulse-burst laser developed in-house, a high-speed CMOS camera, and optimized the optical configuration to capture Rayleigh scattering images of the vaporized fuel jets inside a constant volume chamber. The experimental installation was modified to reduce reflections and flare levels to maximize the images’ signal-to-noise ratios by anti-reflection coatings on windows and surfaces, as well as series of optical baffles. Because of the specificities of the high-speed system, several image processing techniques had to be developed and implemented to provide quantitative fuel concentration measurements. We find that these methods involve various correction procedures such as camera linearity, laser intensity fluctuation, dynamic background flare, as well as beam-steering effects. Image inpainting was also applied to correct the Rayleigh scattering signal from large scatterers (e.g. particulates). The experiments demonstrate that applying planar laser Rayleigh scattering at high repetition rate to quantitatively resolve the mixing of fuel and ambient gases in diesel jets is challenging, but possible. The thorough analysis of the experimental uncertainty and comparisons to past data prove that such measurements can be accurate, whilst providing valuable information about the mixing processes of high-pressure diesel jets.

47 OTHER INSTRUMENTATION↗

Polarization-separated double-imaging spectroscopy for weakly-ionized plasma diagnostics

Laser Thomson scattering, which provides thermal properties of electrons, has been extensively utilized in plasma diagnostics. However, being a non-resonant linear light scattering technique, it often encounters several challenges in weakly-ionized plasma diagnostics due to spectral overlap with different scatterings induced from other existing species, including Mie, Rayleigh, and rotational Raman scatterings. To address this challenge, we propose an imaging spectroscopy technique, polarization-separated double-imaging spectroscopy (PoDIS), which selectively separates specific scatterings based on their polarization characteristics. Using an atmospheric plasma jet as a plasma source for demonstration, we show that PoDIS can effectively separate rotational Raman and Thomson scatterings from a superimposed spectrum without prior knowledge or assumptions about the thermal properties of neutrals or electrons. This separation enables independent fitting of the rotational Raman and Thomson scattering spectra, allowing for precise determination of the thermal properties of neutral particles and electrons separately.

Bak, Junhwi [Texas A&M University, College Station↗

Image-Capture Devices Extend Medicine's Reach

Johnson Space Center, Henry Ford Hospital in Detroit, and Houston-based Wyle Laboratories collaborated on NASA's Advanced Diagnostic Ultrasound in Microgravity (ADUM) experiment, which developed revolutionary medical ultrasound diagnostic techniques for long-distance use. Mediphan, a Canadian company with U.S. operations in Springfield, New Jersey drew on NASA expertise to create frame-grabber and data archiving technology that enables ultrasound users with minimal training to send diagnostic-quality ultrasound images and video to medical professionals via the Internet in near real time allowing patients as varied as professional athletes, Olympians, and mountain climbers to receive medical attention as soon as it is needed.

Source record↗

Focal-Plane Imaging of Crossed Beams in Nonlinear Optics Experiments

An application of focal-plane imaging that can be used as a real time diagnostic of beam crossing in various optical techniques is reported. We discuss two specific versions and demonstrate the capability of maximizing system performance with an example in a combined dual-pump coherent anti-Stokes Raman scattering interferometric Rayleigh scattering experiment (CARS-IRS). We find that this imaging diagnostic significantly reduces beam alignment time and loss of CARS-IRS signals due to inadvertent misalignments.

Bivolaru, Daniel↗

Contrast and harmonic imaging improves accuracy and efficiency of novice readers for dobutamine stress echocardiography

BACKGROUND: Newer contrast agents as well as tissue harmonic imaging enhance left ventricular (LV) endocardial border delineation, and therefore, improve LV wall-motion analysis. Interpretation of dobutamine stress echocardiography is observer-dependent and requires experience. This study was performed to evaluate whether these new imaging modalities would improve endocardial visualization and enhance accuracy and efficiency of the inexperienced reader interpreting dobutamine stress echocardiography. METHODS AND RESULTS: Twenty-nine consecutive patients with known or suspected coronary artery disease underwent dobutamine stress echocardiography. Both fundamental (2.5 MHZ) and harmonic (1.7 and 3.5 MHZ) mode images were obtained in four standard views at rest and at peak stress during a standard dobutamine infusion stress protocol. Following the noncontrast images, Optison was administered intravenously in bolus (0.5-3.0 ml), and fundamental and harmonic images were obtained. The dobutamine echocardiography studies were reviewed by one experienced and one inexperienced echocardiographer. LV segments were graded for image quality and function. Time for interpretation also was recorded. Contrast with harmonic imaging improved the diagnostic concordance of the novice reader to the expert reader by 7.1%, 7.5%, and 12.6% (P < 0.001) as compared with harmonic imaging, fundamental imaging, and fundamental imaging with contrast, respectively. For the novice reader, reading time was reduced by 47%, 55%, and 58% (P < 0.005) as compared with the time needed for fundamental, fundamental contrast, and harmonic modes, respectively. With harmonic imaging, the image quality score was 4.6% higher (P < 0.001) than for fundamental imaging. Image quality scores were not significantly different for noncontrast and contrast images. CONCLUSION: Harmonic imaging with contrast significantly improves the accuracy and efficiency of the novice dobutamine stress echocardiography reader. The use of harmonic imaging reduces the frequency of nondiagnostic wall segments.

Non-NASA Center↗

Retrieval of Temperature and Species Distributions from Multispectral Image Data of Surface Flame Spread in Microgravity

Weight, size, and power constraints severely limit the ability of researchers to fully characterize temperature and species distributions in microgravity combustion experiments. A powerful diagnostic technique, infrared imaging spectrometry, has the potential to address the need for temperature and species distribution measurements in microgravity experiments. An infrared spectrum imaged along a line-of-sight contains information on the temperature and species distribution in the imaged path. With multiple lines-of-sight and approximate knowledge of the geometry of the combustion flowfield, a three-dimensional distribution of temperature and species can be obtained from one hyperspectral image of a flame. While infrared imaging spectrometers exist for collecting hyperspectral imagery, the remaining challenge is retrieving the temperature and species information from this data. An initial version of an infrared analysis software package, called CAMEO (Combustion Analysis Model et Optimizer), has been developed for retrieving temperature and species distributions from hyperspectral imaging data of combustion flowfields. CAMEO has been applied to the analysis of multispectral imaging data of flame spread over a PMMA surface in microgravity that was acquired in the DARTFire program. In the next section of this paper, a description of CAMEO and its operation is presented, followed by the results of the analysis of microgravity flame spread data.

Annen, K. D.↗

Smart Ultrasound Remote Guidance Experiment (SURGE) Preliminary Findings

To date, diagnostic quality ultrasound images were obtained aboard the International Space Station (ISS) using the ultrasound of the Human Research Facility (HRF) rack in the Laboratory module. Through the Advanced Diagnostic Ultrasound in Microgravity (ADUM) and the Braslet-M Occlusion Cuffs (BRASLET SDTO) studies, non-expert ultrasound operators aboard the ISS have performed cardiac, thoracic, abdominal, vascular, ocular, and musculoskeletal ultrasound assessments using remote guidance from ground-based ultrasound experts. With exploration class missions to the lunar and Martian surfaces on the horizon, crew medical officers will necessarily need to operate with greater autonomy given communication delays (round trip times of up to 5 seconds for the Moon and 90 minutes for Mars) and longer periods of communication blackouts (due to orbital constraints of communication assets). The SURGE project explored the feasibility and training requirements of having non-expert ultrasound operators perform autonomous ultrasound assessments in a simulated exploration mission outpost. The project aimed to identify experience, training, and human factors requirements for crew medical officers to perform autonomous ultrasonography. All of these aims pertained to the following risks from the NASA Bioastronautics Road Map: 1) Risk 18: Major Illness and Trauna; 2) Risk 20) Ambulatory Care; 3) Risk 22: Medical Informatics, Technologies, and Support Systems; and 4) Risk 23: Medical Skill Training and Maintenance.

Hurst, Victor↗

A Look from the Inside

NASA's Hubble Space Telescope has given the world amazing images of the distant stars, planets, and galaxies. The cutting-edge imaging technology that enhances the Hubble images also extends its benefits to life here on Earth, from deciphering previously unreadable portions of the Dead Sea Scrolls to improving digital mammographies for advanced cancer detection. This imaging technology is now helping physicians to perform micro-invasive arthroscopic surgery, which is the visual examination of an interior joint such as the knee. In 1997, NASA's Glenn Research Center signed a Space Act Agreement with Micro Medical Devices, Inc. (MMD), a medical device engineering company that licenses miniature surgical devices. At that time, MMD was in the process of developing a new micro-endoscope. This tool enables surgeons to view what is happening inside the body on a screen, eliminating the need for a more invasive diagnostic procedure. The images from the micro-endoscope needed to be extremely clear, a challenge with the tool s small size. The images also needed to be viewed in real time to allow surgeons to see what was happening in the body at that very moment. MMD established Clear Image Technology, LLC, of Elyria, Ohio, to commercialize the miniature endoscope. Clear Image Technology then partnered with Arthrotek, Inc., a sports medicine subsidiary of Biomet, Inc., to introduce the tool to the commercial market as the InnerVue[TM] Diagnostic Scope System. The InnerVue system is designed for use in a diagnostic environment, such as an office or outpatient service, to evaluate conditions within a joint. While the InnerVue scope is primarily being applied to the knee and shoulder, other small joints such as the wrist, elbow, and ankle are being investigated. A physician can use the system alone or in conjunction with magnetic resonance imaging (MRI) to determine the next treatment step for each patient. The procedure can be more accurate than MRI, particularly with diagnosing cartilage and articular surface damage and assessing arthritis severity.

Source record↗

An extended focused assessment with sonography in trauma ultrasound tissue-mimicking phantom for developing automated diagnostic technologies

Medical imaging-based triage is critical for ensuring medical treatment is timely and prioritized. However, without proper image collection and interpretation, triage decisions can be hard to make. While automation approaches can enhance these triage applications, tissue phantoms must be developed to train and mature these novel technologies. Here, we have developed a tissue phantom modeling the ultrasound views imaged during the enhanced focused assessment with sonography in trauma exam (eFAST). The tissue phantom utilized synthetic clear ballistic gel with carveouts in the abdomen and rib cage corresponding to the various eFAST scan points. Various approaches were taken to simulate proper physiology without injuries present or to mimic pneumothorax, hemothorax, or abdominal hemorrhage at multiple locations in the torso. Multiple ultrasound imaging systems were used to acquire ultrasound scans with or without injury present and were used to train deep learning image classification predictive models. Performance of the artificial intelligent (AI) models trained in this study achieved over 97% accuracy for each eFAST scan site. We used a previously trained AI model for pneumothorax which achieved 74% accuracy in blind predictions for images collected with the novel eFAST tissue phantom. Grad-CAM heat map overlays for the predictions identified that the AI models were tracking the area of interest for each scan point in the tissue phantom. Overall, the eFAST tissue phantom ultrasound scans resembled human images and were successful in training AI models. Tissue phantoms are critical first steps in troubleshooting and developing medical imaging automation technologies for this application that can accelerate the widespread use of ultrasound imaging for emergency triage.

60 APPLIED LIFE SCIENCES↗

Advancing the science of explosive fragmentation and afterburn fireballs though experiments and simulations at the benchtop scale

Detonation of explosive devices produces extremely hazardous fragments and hot, luminous fireballs. Prior experimental investigations of these post-detonation environments have primarily considered devices containing hundreds of grams of explosives. While relevant to many applications, such large- scale testing also significantly restricts experimental diagnostics and provides limited data for model validation. As an alternative, the current work proposes experiments and simulations of the fragmentation and fireballs from commercial detonators with less than a gram of high explosive. As demonstrated here, reduced experimental hazards and increased optical access significantly expand the viability of advanced imaging and laser diagnostics. Notable developments include the first known validation of MHz-rate optical fragment tracking and the first ever Coherent Anti-Stokes Raman Scattering (CARS) measures of post-detonation fireball temperatures. While certainly not replacing the need for full-scale verification testing, this work demonstrates new opportunities to accelerate developments of diagnostics and predictive models of post-detonation environments.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗