Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distortion correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

DEVELOPMENT OF DECISION MAKING ALGORITHM FOR CONTROL OF SEA CARGO CONTAINERS BY 'TAGGED' NEUTRON METHOD

Nowadays in Russia and abroad there are several groups of scientists, engaged in development of systems based on 'tagged' neutron method (API method) and intended for detection of dangerous materials, including high explosives (HE). Particular attention is paid to possibility of detection of dangerous objects inside a sea cargo container. Energy gamma-spectrum, registered from object under inspection is used for determination of oxygen/carbon and nitrogen/carbon chemical ratios, according to which dangerous object is distinguished from not dangerous one. Material of filled container, however, gives rise to additional effects of rescattering and moderation of 14 MeV primary neutrons of generator, attenuation of secondary gamma-radiation from reactions of inelastic neutron scattering on objects under inspection. These effects lead to distortion of energy gamma-response from examined object and therefore prevent correct recognition of chemical ratios. These difficulties are taken into account in analytical method, presented in the paper. Method has been validated against experimental data, obtained by the system for HE detection in sea cargo, based on API method and developed in VNIIA. Influence of shielding materials on results of HE detection and identification is considered. Wood and iron were used as shielding materials. Results of method application for analysis of experimental data on HE simulator measurement (tetryl, trotyl, hexogen) are presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Revealing the atomic and electronic structure of a SrTiO{sub 3}/LaNiO{sub 3}/SrTiO{sub 3} heterostructure interface

The atomic structures of SrTiO{sub 3} (STO)/LaNiO{sub 3} (LNO)/STO heterostructure interfaces were investigated by spherical aberration-corrected (C{sub S}) (scanning) transmission electron microscopy. Atomic displacement and lattice distortion measurements and electron energy loss spectroscopy (EELS) were used to quantitatively analyze the distortion of the interfacial octahedra and the bond length at the interfaces. Combined with high-resolution transmission electron microscopy (HRTEM) and scanning transmission electron microscopy analyses, two distinct interfacial atomic terminating layers are unambiguously determined. Ensuing quantitative HRTEM measurements revealed that the Ni-O bond length in the interfacial octahedral is elongated at the bottom interface (–NiO{sub 2}-SrO–). Atomic displacement shows structural relaxation effects when crossing the interfaces and lattice distortions across the interface is more pronounced in LNO than in STO. The Ti/O atomic ratio, La and Ti relative atomic ratio as derived by EELS quantification indicate non-stoichiometric composition at the interfaces. Distinct fine structures of Ti-L{sub 2,3} edge and O-K edge at the bottom and top interfaces are observed. By comparison, we are able to estimate Ti valency at both interfaces. Combining the structural distortions and Ti valency, the polar discontinuity and charge transfer at the interfaces are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

THE M31 VELOCITY VECTOR. I. HUBBLE SPACE TELESCOPE PROPER-MOTION MEASUREMENTS

We present the first proper-motion (PM) measurements for the galaxy M31. We obtained new V-band imaging data with the Hubble Space Telescope ACS/WFC and the WFC3/UVIS instruments of three fields: a spheroid field near the minor axis, an outer disk field along the major axis, and a field on the Giant Southern Stream. The data provide five to seven year time baselines with respect to pre-existing deep first-epoch observations of the same fields. We measure the positions of thousands of M31 stars and hundreds of compact background galaxies in each field. High accuracy and robustness is achieved by building and fitting a unique template for each individual object. The average PM for each field is obtained from the average motion of the M31 stars between the epochs with respect to the background galaxies. For the three fields, the observed PMs ({mu}{sub W}, {mu}{sub N}) are, in units of mas yr{sup -1}, (- 0.0458, -0.0376) {+-} (0.0165, 0.0154), (- 0.0533, -0.0104) {+-} (0.0246, 0.0244), and (- 0.0179, -0.0357) {+-} (0.0278, 0.0272), respectively. The ability to average over large numbers of objects and over the three fields yields a final displacement accuracy of a few thousandths of a pixel, corresponding to only 12 {mu}as yr{sup -1}. This is comparable to what has been achieved for other Local Group galaxies using Very Long Baseline Array observations of water masers. Potential systematic errors are controlled by an analysis strategy that corrects for detector charge transfer inefficiency, spatially and time-dependent geometric distortion, and point-spread function variations. The robustness of the PM measurements and uncertainties are supported by the fact that data from different instruments, taken at different times and with different telescope orientations, as well as measurements of different fields, all yield statistically consistent results. Papers II and III of this series explore the implications of the new measurements for our understanding of the history, future, and mass of the Local Group.

79 ASTRONOMY AND ASTROPHYSICS↗

The charge and mass symmetry breaking in the KK K¯ system

Abstract In the framework of the Faddeev equations in configuration space, we investigate theK(1460) meson as a resonant state of the KK K ¯ kaonic system. We perform calculations for the particle configurationsK 0 K + K − and K 0 K + K 0 ¯ within two models: theABCmodel, in which all three particles are distinguishable, and theAACmodel when two particles are identical. The models differ in their treatment of the kaon mass difference and the attractive Coulomb force between theK + K − pair. We found that the Coulomb shift adds over 1 MeV to the three-body binding energy. The expected correction to the binding energy due to mass redistribution fromAAtoABis found to be negligible, up to a maximum of 6% of the relative mass correction. At the same time, the symmetry of the wave function is distorted depending on the mass ratio value. We found that the repulsiveKKinteraction plays an essential role in the binding energy of the KK K ¯ system and reports the mass of 1461.8 or 1464.1 MeV for the neutralK 0 (1460) and 1466.5 or 1468.8 MeV for the chargedK + (1460) resonances, respectively, depending on the parameter sets forKKand K K ¯ interactions.

Physics↗

Towards a new generation long trace profiler LTP-2020: optical design of pencil beam interferometry sensor

Improvements in the quality of synchrotron beamline x-ray optics required for next-generation light sources (e.g. the ALS Upgrade project) drive the need to improve the performance of the metrology instrumentation used to measure these components. The Long Trace Profiler (LTP) that is in use at many synchrotron metrology laboratories around the world has some known issues that affect the accuracy of its measurements. The main error source is optical path difference (OPD) phase error introduced into the probe beam by inhomogeneities in the glass components used in the optical head. We have developed a new optical head design, LTP-2020, that replaces the cube polarizing beamsplitter (PBS) with a thin wedge plate polarizing beamsplitter (WPBS) and replaces the cemented doublet lens with an aspheric singlet. Both of these components significantly reduce the glass volume traversed by the laser probe beam. Careful attention to ghost ray interference produced by back reflection from optical surfaces is necessary to minimize distortion in the primary image that translates into systematic error in the slope angle measurement. We make extensive use of a commercial raytracing program to model the back reflections and adjust component parameters as necessary to minimize distortion. Deliberate misalignment of components is necessary to make the system perform correctly. Stringent requirements are placed on the 45◦ incidence coatings on the WPBS and on the normal incidence coatings on the lens and camera window elements. We encourage our colleagues who wish to upgrade their current LTP systems to join us in the procurement of these custom optical components.

Takacs, Peter Z.↗

APPLICATION OF NEURAL NETWORK ALGORITHMS FOR BPM LINEARIZATION

Stripline BPM sensors contain inherent non-linearities, as a result of field distortions from the pickup elements. Many methods have been devised to facilitate corrections, often employing polynomial fitting. The cost of computation makes real-time correction difficult, particulalry when integer math is utilized. The application of neural-network technology, particularly the multi-layer perceptron algorithm, is proposed as an efficient alternative for electrode linearization. A process of supervised learning is initially used to determine the weighting coefficients, which are subsequently applied to the incoming electrode data. A non-linear layer, known as an activation layer, is responsible for the removal of saturation effects. Implementation of a perceptron in an FPGA-based software-defined radio (SDR) is presented, along with performance comparisons. In addition, efficient calculation of the sigmoidal activation function via the CORDIC algorithm is presented.

43 PARTICLE ACCELERATORS↗

UCAC3: ASTROMETRIC REDUCTIONS

Presented here are the details of the astrometric reductions from the x, y data to mean right ascension (R.A.), declination (decl.) coordinates of the third U.S. Naval Observatory CCD Astrograph Catalog (UCAC3). For these new reductions we used over 216,000 CCD exposures. The Two-Micron All-Sky Survey (2MASS) data are used extensively to probe for coordinate and coma-like systematic errors in UCAC data mainly caused by the poor charge transfer efficiency of the 4K CCD. Errors up to about 200 mas have been corrected using complex look-up tables handling multiple dependences derived from the residuals. Similarly, field distortions and sub-pixel phase errors have also been evaluated using the residuals with respect to 2MASS. The overall magnitude equation is derived from UCAC calibration field observations alone, independent of external catalogs. Systematic errors of positions at the UCAC observing epoch as presented in UCAC3 are better corrected than in the previous catalogs for most stars. The Tycho-2 catalog is used to obtain final positions on the International Celestial Reference Frame. Residuals of the Tycho-2 reference stars show a small magnitude equation (depending on declination zone) that might be inherent in the Tycho-2 catalog.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the importance of satellite lines to the He-like alpha complex and the G ration for calcium, iron, and nickel

New, more detailed calculations of the emission spectra of the He-like Ko complex of calcium, iron and nickel have been carried out using data from both distorted-wave and R-matrix calculations. The value of the GD ratio (a corrected version of the G ratio that accounts for the effect of unresolved satellite lines) is significantly enhanced at temperatures below the temperature of He-like maximum abundance. Furthermore it is shown that satellite lines are important contributors to the G D ratio at temperatures well above the temperature of maximum abundance. These new calculations demonstrate that satellite lines need to be included in models of He-like Ko spectra even at relatively high temperatures. The excellent agreement between spectra and line ratios calculated from R-matrix and distorted-wave data also confirms the validity of models based on distorted-wave data for highly charged systems, provided the effect of resonances are taken into account as independent processes.

36 MATERIALS SCIENCE↗

Dynamic scan control in STEM: spiral scans

Abstract Scanning transmission electron microscopy (STEM) has emerged as one of the foremost techniques to analyze materials at atomic resolution. However, two practical difficulties inherent to STEM imaging are: radiation damage imparted by the electron beam, which can potentially damage or otherwise modify the specimen and slow-scan image acquisition, which limits the ability to capture dynamic changes at high temporal resolution. Furthermore, due in part to scan flyback corrections, typical raster scan methods result in an uneven distribution of dose across the scanned area. A method to allow extremely fast scanning with a uniform residence time would enable imaging at low electron doses, ameliorating radiation damage and at the same time permitting image acquisition at higher frame-rates while maintaining atomic resolution. The practical complication is that rastering the STEM probe at higher speeds causes significant image distortions. Non-square scan patterns provide a solution to this dilemma and can be tailored for low dose imaging conditions. Here, we develop a method for imaging with alternative scan patterns and investigate their performance at very high scan speeds. A general analysis for spiral scanning is presented here for the following spiral scan functions: Archimedean, Fermat, and constant linear velocity spirals, which were tested for STEM imaging. The quality of spiral scan STEM images is generally comparable with STEM images from conventional raster scans, and the dose uniformity can be improved.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calibration of megavoltage cone-beam CT for radiotherapy dose calculations: Correction of cupping artifacts and conversion of CT numbers to electron density

Megavoltage cone-beam CT (MV CBCT) is used for three-dimensional imaging of the patient anatomy on the treatment table prior to or just after radiotherapy treatment. To use MV CBCT images for radiotherapy dose calculation purposes, reliable electron density (ED) distributions are needed. Patient scatter, beam hardening and softening effects result in cupping artifacts in MV CBCT images and distort the CT number to ED conversion. A method based on transmission images is presented to correct for these effects without using prior knowledge of the object's geometry. The scatter distribution originating from the patient is calculated with pencil beam scatter kernels that are fitted based on transmission measurements. The radiological thickness is extracted from the scatter subtracted transmission images and is then converted to the primary transmission used in the cone-beam reconstruction. These corrections are performed in an iterative manner, without using prior knowledge regarding the geometry and composition of the object. The method was tested using various homogeneous and inhomogeneous phantoms with varying shapes and compositions, including a phantom with different electron density inserts, phantoms with large density variations, and an anthropomorphic head phantom. For all phantoms, the cupping artifact was substantially removed from the images and a linear relation between the CT number and electron density was found. After correction the deviations in reconstructed ED from the true values were reduced from up to 0.30 ED units to 0.03 for the majority of the phantoms; the residual difference is equal to the amount of noise in the images. The ED distributions were evaluated in terms of absolute dose calculation accuracy for homogeneous cylinders of different size; errors decreased from 7% to below 1% in the center of the objects for the uncorrected and corrected images, respectively, and maximum differences were reduced from 17% to 2%, respectively. The presented method corrects the MV CBCT images for cupping artifacts and extracts reliable ED information of objects with varying geometries and composition, making these corrected MV CBCT images suitable for accurate dose calculation purposes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correlating structural, electronic, and magnetic properties of epitaxial VSe 2 thin films

The electronic and magnetic properties of transition metal dichalcogenides are known to be extremely sensitive to their structure. In this paper we study the effect of structure on the electronic and magnetic properties of mono- and bilayer VSe 2 films grown using molecular beam epitaxy. VSe 2 has recently attracted much attention due to reports of emergent ferromagnetism in the two-dimensional (2D) limit. To understand this compound, high-quality 1$\textit{T}$ and distorted 1$\textit{T}$ films were grown at temperatures of 200 °C and 450 °C, respectively, and studied using 4 K scanning tunneling microscopy and spectroscopy. The measured density of states and the charge density wave (CDW) patterns were compared to band structure and phonon dispersion calculations. Films in the 1$\textit{T}$ phase reveal different CDW patterns in the first layer compared to the second. Interestingly, we find the second layer of the 1$\textit{T}$ film shows a CDW pattern with 4$\textit{a}$ × 4$\textit{a}$ periodicity which is the 2D version of the bulk CDW observed in this compound. We report our phonon dispersion calculations confirm the presence of a soft phonon at the correct wave vector that leads to this CDW. In contrast, the first layer of distorted 1$\textit{T}$ phase films shows a strong stripe feature with varying periodicities, while the second layer displays no observable CDW pattern. Finally, we find that the monolayer 1$\textit{T}$ VSe 2 film is weakly ferromagnetic, with ~3.5 $μ_B$ per unit similar to previous reports.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Adaptive system for wavefront correction of the PEARL laser facility

The results of the operation of a wavefront correction system based on a deformable bimorph mirror of the PEARL subpetawatt laser facility are presented. An improvement in the quality of focusing of laser radiation, which led to an increase in the Strehl ratio from 0.3 to 0.6, is demonstrated. The features of the compensation for phase distortions of the wavefront in the case of a low pulse repetition rate, as well as the correct allowance for the noise of the CCD camera when calculating the Strehl ratio are investigated. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Type Ia Supernova Growth-rate Measurement with LSST Simulations: Intrinsic Scatter Systematics

Measurement of the growth rate of structures (fσ 8 ) with Type Ia supernovae (SNe Ia) will improve our understanding of the nature of dark energy and enable tests of general relativity. In this paper, we generate simulations of the 10 yr SN Ia data set of the Rubin-LSST survey, including a correlated velocity field from an N-body simulation and realistic models of SNe Ia properties and their correlations with host-galaxy properties. We find, similar to SN Ia analyses that constrain the dark energy equation-of-state parameters w 0 w a , that constraints on fσ 8 can be biased depending on the intrinsic scatter of SNe Ia. While for the majority of intrinsic scatter models we recover fσ 8 with a precision of ∼13%–14%, for the most realistic dust-based model, we find that the presence of non-Gaussianities in Hubble diagram residuals leads to a bias on fσ 8 of ∼ −20%. When trying to correct for the dust-based intrinsic scatter, we find that the propagation of the uncertainty on the model parameters does not significantly increase the error on fσ 8 . We also find that while the main component of the error budget of fσ 8 is the statistical uncertainty (>75% of the total error budget), the systematic error budget is dominated by the uncertainty on the damping parameter, σ u , that gives an empirical description of the effect of redshift space distortions on the velocity power spectrum. Our results motivate a search for new methods to correct for the non-Gaussian distribution of the Hubble diagram residuals, as well as an improved modeling of the damping parameter.

Carreres, Bastien [Duke Univ., Durham, NC (United ↗

Study of Pile-Up Effects in Decay Energy Spectroscopy

Pile-up is an unavoidable complication for cryogenic detectors with relatively large heat capacities and slow rise time, such as systems for decay energy spectroscopy employing large Au absorbers. We have simulated the spectral response of such slow cryogenic detectors using Monte-Carlo algorithms to investigate the effects of pile-up on absolute and relative activity measurements. We focus on the impact of non-distinguishable pile-up that occurs when the rising edges of two waveforms originating from different events overlap in time and are interpreted as a single event. This effect can not be readily identified and corrected in experimental data. We investigated two representative cases of absolute decay counting and plutonium isotopic analysis and find that pile-up can distort the reconstruction of both the absolute and relative activities. This Monte-Carlo methodology quantifies of pile-up effects and provides a systematic methodology for calculating corrective factors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Gas-Phase Complexes of Americium and Lanthanides with a Bis-triazinyl Pyridine: Reactivity and Bonding of Archetypes for F-Element Separations

Bis-triazinyl pyridines (BTPs) exhibit solution selectivity for trivalent americium over lanthanides (Ln), the origins of which remain uncertain. Here in this paper, electrospray ionization was used to generate gas-phase complexes [ML 3 ] 3+ , where M = La, Lu, or Am and L is EtBTP 2,6-bis(5,6-diethyl-1,2,4-triazin-3-yl)-pyridine. Collision-induced dissociation (CID) of [ML 3 ] 3+ in the presence of H 2 O yielded a protonated ligand [L(H)] + and hydroxide [ML 2 (OH)] 2+ or hydrate [ML(L–H)(H 2 O)] 2+ , where (L–H) - is a deprotonated ligand. Although solution affinities indicate stronger binding of BTPs toward Am 3+ versus Ln 3+ , the observed CID process is contrastingly more facile for M = Am versus Ln. To understand the disparity, density functional theory was employed to compute potential energy surfaces for two possible CID processes, for M = La and Am. In accordance with the CID results, both the rate determining transition state barrier and the net energy are lower for [AmL 3 ] 3+ versus [LaL 3 ] 3+ and for both product isomers, [ML 2 (OH)] 2+ and [ML(L–H)(H 2 O)] 2+ . More facile removal of a ligand from [AmL 3 ] 3+ by CID does not necessarily contradict stronger Am 3+ –L binding, as inferred from solution behavior. In particular, the formation of new bonds in the products can distort kinetics and thermodynamics expected for simple bond cleavage reactions. In addition to correctly predicting the seemingly anomalous CID behavior, the computational results indicate greater participation of Am 5f versus La 4f orbitals in metal–ligand bonding.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

coh3

CoH3 (CoH ver.3) is an optical model, exciton pre-equilibrium, and Hauser-Feshbach statistical model code, which calculates nuclear reaction cross sections for medium to heavy targets in the keV to MeV energy region. This program is written in standard C++, divided into approximately 200 source and header files. CoH solves the Schroedinger equation for optical potentials defined in the code, and calculates differential elastic scattering, reaction, and total cross sections, for neutron, proton, deuteron, triton, 3He, and alpha-particle. Deformed optical potentials are solved with the coupled-channels method, in which the ground state rotational band members, or vibrational phonon states are coupled. The optical model gives particle transmission coefficients that are fed into the statistical model calculations. CoH includes the pre-equilibrium model (exciton model), the direct/semidirect capture model, and the multi-stage Hauser-Feshbach statistical decay with width fluctuation correction based on the Gaussian orthogonal ensemble. For weakly coupled levels, the DWBA (distorted wave Born approximation) method is used to calculate the direct inelastic scattering process to the excited states.

Kawano, Toshihiko↗

Photometric Objects Around Cosmic Webs (PAC) Delineated in a Spectroscopic Survey. IV. High-precision Constraints on the Evolution of the Stellar–Halo Mass Relation at Redshift z < 0.7

Taking advantage of the Photometric objects Around Cosmic webs method developed in Paper I, we measure the excess surface density $\overline{n}$ 2 w p of the photometric objects around spectroscopic objects down to stellar masses 10 8.0 M ⊙ , 10 9.2 M ⊙ , and 10 9.8 M ⊙ in the redshift ranges of z s < 0.2, 0.2 < z s < 0.4, and 0.5 < z s < 0.7, respectively, using data from the DESI Legacy Imaging Surveys and spectroscopic samples from the Sloan Digital Sky Survey (i.e., the Main, LOWZ, and CMASS samples). We model the measured in an N-body simulation, using the abundance matching method, and we constrain the stellar–halo mass relations (SHMRs) in the three redshift ranges to percent levels. With the accurate modeling, we demonstrate that the stellar mass scatter for a given halo mass is nearly a constant, and that the empirical form of Behroozi et al. describes the SHMR better than the double-power-law form at low mass. Our SHMR accurately captures the downsizing of massive galaxies from z s = 0.7, while it also indicates that small galaxies are still growing faster than their host halos. The galaxy stellar mass functions (GSMFs) from our modeling are in perfect agreement with the model-independent measurements in Paper III, although the current work extends the GSMFs to a much smaller stellar mass. Based on the GSMFs and the SHMRs, we derive the stellar mass completeness and halo occupation distributions for the LOWZ and CMASS samples, which are useful for correctly interpreting their cosmological measurements, such as galaxy–galaxy lensing and redshift space distortion.

79 ASTRONOMY AND ASTROPHYSICS↗