Search NASA⌕ Search

SEARCH · Search NASA

Results for “Drop test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Thermal-Hydraulic Performance of a Zeotropic Refrigerant in a Brazed Plate Evaporator

In this work we report the results of a preliminary investigation focused on evaluating the thermal-hydraulic performance of R455A (CO2, R32, R1234yf – 3/21.5/75.5) in a commercial brazed plate heat exchanger. Three key parameters were measured which were refrigerant flow maldistribution, overall refrigerant side heat transfer coefficient, and total refrigerant side pressure drop. These same parameters were also measured for R134a which served as a base-line refrigerant for comparison. The experimental test matrix was set up to investigate the influence of refrigerant mass flux (3 ≤ Gref ≤ 5 kg m-2 s-1), refrigerant inlet vapor quality (0.1 ≤ xin ≤ 0.4), and refrigerant exit superheat (5 ≤ Tsh ≤ 10 K) on the above mentioned thermal-hydraulic parameters. For these experimental conditions, on average, the overall refrigerant side heat transfer coefficients for R455A were 45.2% lower than those of R134a. Refrigerant flow maldistribution for R455A, on average, was observed to be 62.6 % higher than that measured for R134a, and the total pressure drop across the heat exchanger (minor and frictional losses) for R455A was on average 26.5% higher than that measured for R134a. These initial results set the stage for a comprehensive investigation focused on further investigating the thermal-hydraulic performance of zeotropic refrigerants in brazed plate heat exchangers.

Jajja, Saad [ORNL]↗

COVID-19 global pandemic planning: Performance and electret charge of N95 respirators after recommended decontamination methods

Shortages of N95 respirators for use by medical personnel have driven consideration of novel conservation strategies, including decontamination for reuse and extended use. Decontamination methods listed as promising by the Centers for Disease Control and Prevention (CDC) (vaporous hydrogen peroxide (VHP), wet heat, ultraviolet irradiation (UVI)) and several methods considered for low resource environments (bleach, isopropyl alcohol and detergent/soap) were studied for two commonly used surgical N95 respirators (3M™ 1860 and 1870+ Aura™). Although N95 filtration performance depends on the electrostatically charged electret filtration layer, the impact of decontamination on this layer is largely unexplored. As such, respirator performance following decontamination was assessed based on the fit, filtration efficiency, and pressure drop, along with the relationship between (1) surface charge of the electret layer, and (2) elastic properties of the straps. Decontamination with VHP, wet heat, UVI, and bleach did not degrade fit and filtration performance or electret charge. Isopropyl alcohol and soap significantly degraded fit, filtration performance, and electret charge. Pressure drop across the respirators was unchanged. Modest degradation of N95 strap elasticity was observed in mechanical fatigue testing, a model for repeated donnings and doffings. CDC recommended decontamination methods including VHP, wet heat, and UV light did not degrade N95 respirator fit or filtration performance in these tests. Extended use of N95 respirators may degrade strap elasticity, but a loss of face seal integrity should be apparent during user seal checks. NIOSH recommends performing user seal checks after every donning to detect loss of appropriate fit. Decontamination methods which degrade electret charge such as alcohols or detergents should not be used on N95 respirators. The loss of N95 performance due to electret degradation would not be apparent to a respirator user or evident during a negative pressure user seal check.

60 APPLIED LIFE SCIENCES↗

Advancing 1D thermo-hydraulic tools for large cryogenic facilities

The Cryogenic Division at Fermilab develops large-scale cryogenic systems for particle accelerators and superconducting test facilities. To support design and diagnostics, a Python-based code was created to calculate pressure drops in components such as valves and pipes. This paper presents recent enhancements to the code, including new heat transfer functions that improve the accuracy of thermal and hydraulic predictions. The first application models pressure and temperature changes in PIP-II relief pipes, aiding pipe sizing and protecting relief valves. The second example analyzes heat load evolution in a pipe carrying sub-atmospheric helium, helping interpret temperature sensor data and understand gas return behavior to cold compressors. These improvements significantly expand the tool’s capabilities, offering a practical resource for designing and troubleshooting cryogenic systems under dynamic thermal and flow conditions.

Beckwith, Rosalyn [Fermilab]↗

Advancing 1D thermo-hydraulic tools for large cryogenic facilities

The Cryogenic Division at Fermilab develops large-scale cryogenic systems for particle accelerators and superconducting magnet test facilities. To support design and diagnostics, a Python-based code was created to calculate pressure drops in components such as valves and pipes. This paper presents recent enhancements to the code, including new heat transfer functions that improve the accuracy of thermal and hydraulic predictions. The first application models pressure and temperature changes in Proton Improvement Plant PIP-II relief pipes, aiding pipe sizing and protecting relief valves. The second example analyses heat load evolution in a pipe carrying sub-atmospheric helium, helping interpret temperature sensor data and understand gas return behavior to cold compressors. These improvements significantly expand the tool's capabilities, offering a practical resource for designing and troubleshooting cryogenic systems under dynamic thermal and flow conditions.

Beckwith, R. [Fermilab]↗

Mu2e Target Thermal Test Project

The Mu2e experiment requires a production target capable of operating under extreme thermal conditions caused by an 8 GeV proton beam. This project’s objective supports the development of the Mu2e Production Target by testing the Stickman model’s thermal behavior. To test this, Angel Flores Luviano has assisted Jonathan Williams in progressing this project by contributing to the development of a Radiative Cooling Test Fixture (RCTF) that will be used to evaluate the thermal behavior of the new production target model. Engineering calculations were performed to analyze thermal performance and pressure drop within the cold well and water cooling circuit, and determine optimal sizing for key components of the water system. An engineering note was made to document the calculations. CAD models of the water circuit piping, thermocouple mount, and radiator chimney were developed, and prototype test rig components were fabricated using 3D printing. Future work will focus on conti nued RCTF development which includes control system integration, heater hardware design, and interfaces that can be scaled up to increase thermal capacity.

Luviano, Angel Flores [Unlisted]↗

Thirty Minutes Before the Dawn

The Trinity test of July 16, 1945, marked the scientific apex of the Manhattan Project. Often recognized as the symbolic birth of the nuclear age, Trinity’s multifaceted legacy remains just as captivating and complex today as it did 75 years ago. This paper examines why the test was necessary from a technical standpoint, shows how Los Alamos scientists planned the event, and explores the physical and emotional aftermaths of Trinity. The author also uses rarely accessed original records to reconstruct the story of Trinity’s health hazards, as seen through the eyes of radiation technicians and medical doctors as events unfolded. Trinity was conducted as the Potsdam Conference began, weeks after the collapse of Nazi Germany. It was considered necessary to let President Harry S. Truman know whether the United States possessed a nuclear capability ahead of his negotiations with Joseph Stalin, the Soviet premier. The author examines the competing priorities that drove the timetable for the test: international politics, security, and safety. Three weeks after Trinity, a gun-assembled enriched-uranium bomb called Little Boy was used against the Japanese city of Hiroshima. Three days later, Fat Man, a weaponized version of the imploding Trinity device, was dropped on Nagasaki. The author briefly examines these strikes and what impact they may have had on the Japanese surrender. The paper concludes by examining the legacy of the Trinity test 75 years into the age it helped usher in.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

A methodology for domain overlapping coupling of thermal-hydraulic systems

Multi-scale coupling has increasingly drawn attention as a promising approach for modeling thermal systems. Traditional system codes provide fast and robust predictions at the plant scale, while high-fidelity computational fluid dynamics (CFD)-based tools resolve localized flow and heat transfer phenomena with greater accuracy. By combining these complementary strengths, co-simulations enable multi-scale analysis that would otherwise be computationally prohibitive for a standalone CFD code. Here, this work introduces a robust and problem-agnostic domain overlapping (DO) coupling between the system thermal-hydraulic (STH) code System Analysis Module (SAM) and the coarse-mesh CFD code Pronghorn. Both applications belong to the Comprehensive Reactor Analysis Bundle (BlueCRAB) code suite, a code suite in active development at the Idaho National Laboratory (INL), tailored for multi-physics analysis of advanced reactors. Unlike previous approaches, BlueCRAB supports an agnostic interface between codes based on different fidelity, while its coupling formulation can address arbitrary flow geometries with multiple inlets and outlets in coupled components. The implemented method leads to consistent pressure drops, enthalpies, and scalar concentrations between coupled SAM and Pronghorn simulations. The methodology is demonstrated through two verification tests, which ensure the numerical consistency and conservation across the codes, and through one validation test against experimental data. The proposed problems explore different physical aspects inherent to thermal systems, with particular attention given to nuclear reactor analysis. These include buoyancy-driven flows, complex flow patterns, and setups with multiple inlets and outlets, representing challenges in advanced reactor applications.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of Quantum Computing Interconnect Based on Aerosol Jet Printing and Electrochemical Deposition of Rhenium

The electrodeposition of rhenium on to a metal seed layer on flexible substrates is presented as a means to creating superconducting flexible cable connectors in an enabling plug-and-play approach for quantum computing. Cryogenic quantum electronics are currently connected using masses of stainless-steel coaxial cables that are bulky, rigid - both in form and design - and lead to significant joule heating, thermal noise, and cross talk. Here, we present an unprecedented approach to integrate an aerosol jet printed (AJP) metal seed layer with rhenium electrodeposition on a flexible substrate in the advancement of superconducting interconnect technologies. Silver and gold were printed using the ‘Nanojet’ aerosol jet printer on Kapton films. Adhesion of gold was found to be far superior to that of silver and adhesion on roughened Kapton surpassed that of its smooth counterpart. Electrodeposition of rhenium was successful on both silver and gold and an amorphous Re film was confirmed by XRD. Results for both materials are presented however due to the poor adhesion of silver to Kapton it was ruled out as a viable candidate. Composite materials were characterized by profilometry, EDS, XRD and FIBSEM. Electrical measurements of the composite at ambient temperature showed a critical temperature (T c ), where the resistance drops to 0, of 5.8 K, well above 4.2 K, the temperature of liquid helium. Stress-strain tests of the Ag-Re and Au-Re composites on roughened and smooth Kapton were completed. Cyclic flexure testing (200 cycles) to 1.25% strain showed smooth Kapton samples reach a stress of ~16 MPa, while Kapton roughened with sandpaper, reaches ~20MPa of stress for the same 1.25% strain.

36 MATERIALS SCIENCE↗

CEBAF Accelerator Tunnel Robot Project

Advancements in the field of robotics allow for the use of remotely controlled robots to perform tasks that have typically required human intervention. Jefferson Lab has explored the possibilities of robots placed in the accelerator tunnel to perform remote inspections that would otherwise require powering down equipment and completing lengthy radiological surveys that impact beam operations. A robotic solution ? driven by a human operator ? could not only reduce accelerator down time but also support the Lab's radiation exposure policy (known as "ALARA" - As Low As Reasonably Acceptable) by handling routine tunnel and beamline investigations in place of a human being. However, operating a remote device in a radioactive, high electronic-noise area is not a trivial task and drop-in solutions are rarely as simple as they seem. We will present the past prototypes that were tested as well follow-on technology developed from the project. We will also briefly survey current applications of robots at accelerator facilities with an eye toward future applications.

McGuckin, Theodore↗

VitriEdge: Repairable & Durable Vitrimer Coatings for Wind Turbine Blade Leading Edges

The primary goal of this Level 1b incubator project was to explore the use of vitrimer coatings for repair of leading-edge erosion on end-of-life wind turbine blade surfaces, beyond coating strength of adhesion which has previously been demonstrated in the Level 1a project. Uniform vitrimer coatings (thickness: 400 µm) were applied to two end-of-life wind turbine blades for flexural, fatigue, and laminate tensile testing where the addition of the coating did not produce any statistical variation in tensile properties with minor drops in flexural strength for some laminate formulations. However, a <2% variation in storage modulus was measured for laminate structures (i.e., blade samples with vitrimer coatings) across 100,000 flexural cycles and upon laminate tensile failure, the vitrimer coatings displayed no visible signs of delamination. In addition, three methods to heal vitrimer coating damage was displayed: oven heating, addition of hot water, and a forced convection heat gun. All three heating and healing mechanisms demonstrated significant healing with scratch depths decreasing between 79-91% at healing times ranging between 1-min and 10-minutes. Finally, a water jet machine was used to simulate rain erosion for both the blade surfaces and vitrimer-coated blade surfaces where the diameter and depth of the damage was recorded as a function of exposure time, water pressure, height of exposure, and angle of exposure. Of interest, while the vitrimer coating did not significantly lessen the damage experienced during rain erosion, the addition of vitrimer composite coatings(5 wt.% mica addition) did result in a crack-resistant, durable coating capable of self-healing behavior and in all cases the angle of rain exposure was the most critical parameter explored. It is crucial to continue exploring this space where vitrimer coatings are of interest for both their self-healing properties and potential use as reversible adhesives.

17 WIND ENERGY↗

Changes in SSL Device Efficiency and Optical Performance Under Accelerated Aging Conditions

Lighting application efficiency (LAE) describes the efficient delivery of light from the light source to the lighted task and is viewed as a new frontier—increasing energy savings with solid-state lighting (SSL) technologies. The framework for LAE that is proposed by the U.S. Department of Energy (DOE) consists of four major elements: light source efficiency, optical delivery efficiency, spectral efficiency, and intensity effectiveness. This report focuses on a sampling of the available SSL products that can be broadly defined as having modified spectral output because the method of spectra modification has a significant impact on light source efficiency and long-term optical delivery and spectral efficiencies. This report focused on the changes in light source, optical delivery, and spectral efficiencies that occur during aging of SSL devices. An accelerated stress test (AST) regiment was developed for the devices under test (DUTs) examined in this report to provide insights into how the performance of SSL devices change with aging. The AST protocols demonstrate that the SSL products discussed in this report often reduce light source efficiency to achieve different spectral characteristics. In addition, aging of the optical components (e.g., lenses, solder masks) in SSL devices can produce increased light absorption, which negatively impacts optical delivery efficiency and light source efficiency. The modified spectral outputs of the selected SSL products discussed in this report come in a variety of form factors and achieve enhanced optical performance by using a variety of methods. All of the products examined in this study use mid-power light-emitting diodes (MP-LEDs), although the number, configuration, phosphor content, and light-emitting diode (LED) pump of the MP-LEDs differ. Product MS-1 is a 60-watt (W) replacement A19 lamp with a hermetically sealed glass globe, which contains an embedded optical filter to absorb green and yellow emissions, thereby creating a “sunlike” modified spectrum. Product MS-2 is a 60-W replacement A19 lamp with 30 MP-LEDs, and it uses a violet LED pump, along with green and red phosphor emissions, to produce a “healthy” spectrum. This spectrum omits blue emissions in an effort to reduce melanopic lux. Product MS-3 is an LED module consisting of 21 MP-LEDs that use a violet LED pump, along with blue, green, and red phosphors, to produce a “sunlike” spectrum. Products MS-4 and MS-5 are both 6-inch (in) downlights that use a manual switching mechanism so that users can select application-specific correlated color temperatures before installation. Products MS-4 and MS-5 both contain two LED primaries (2,700 Kelvin [K] and 5,000 K) for spectral tuning. Product MS-4 contains 12 MP-LEDs for each LED primary, and Product MS-5 contains 10 MP-LEDs for each LED primary. This report summarizes the overall findings from up to 8,000 hours (hrs) of AST on the lamp DUTs (Products MS-1 and MS-2); up to 5,000 hrs of AST on the LED light engine DUTs (Product MS-3); and up to 7,000 hrs of AST on the downlight DUTs (Products MS-4 and MS-5). The AST procedures used in this study included a room temperature operational life (RTOL) test, an operational life test conducted at 45 degrees Celsius (°C; 45OL) test, an operational life test conducted at 75°C (75OL), a wet high-temperature operational life test performed at 65°C and 90% relative humidity (6590), and a wet high-temperature operational life test performed at 75°C and 75% relative humidity (7575). The AST procedures used for Products MS-1 and MS-2 were RTOL, 45OL, and 6590. The AST procedures used for Products MS-3, MS-4, and MS-5 were RTOL, 75OL, and 7575. During the ASTs described herein, separate populations of each product (three DUTs in each population for Products MS-1, MS-2, MS-4, and MS-5; four DUTs in each population for Product MS-3) were subjected to power cycling of 1 hr on and 1 hr off. The key findings from this study include the following. Enhanced optical performance came at the cost of reduced light source efficiency for the lamps and light engines examined in this study. The optical filter used to produce a “sunlike” spectrum for Product MS-1 reduced light source efficiency by 26%, from 113 lumens per watt (lm/W) to 85 lm/W. Products MS-2 and MS-3 that used a violet-pumped LED to achieve “healthy” and “sunlike” enhanced optical performance, respectively, suffered the largest reduction in initial light source efficiency (49 lm/W for Product MS-2 and 68 lm/W for Products MS-3) perhaps because of the use of violet LED as the optical pump. Product MS-2 also had the poorest color fidelity because of undersaturation of blues and oversaturation of greens and yellows. Chromaticity maintenance of the products in this study was generally good, with parametric failure only occurring for one product at one AST condition (i.e., Product MS-3 at 7575). The chromaticity shift for Product MS-3 in 7575 test conditions resulted from reduced emissions of the broad green and red phosphors used to mimic sunlight in the 500–750 nanometer (nm) range. As a result of these phosphor emission losses, chromaticity shifted toward the more stable violet-pumped LED and blue phosphor. Although chromaticity maintenance was acceptable for most products tested, different chromaticity shift mechanisms were observed for temperature and humidity tests compared with temperature alone for Products MS-1, MS-2, and MS-3. For Product MS-1, a relative increase in green emissions was observed with humidity, which may indicate humidity-accelerated degradation of the optical filter at green wavelengths (optical delivery efficiency reduction) or degradation of the emitters in the red region (spectral efficiency reduction). The violet-pumped products (i.e., MS-2 and MS-3) exhibited different chromaticity shift behavior in the temperature-humidity environments, with Product MS-2 shifting generally yellow because of photo-induced oxidation of the plastic globe (i.e., a reduction of optical delivery efficiency) and Product MS-3 shifting toward violet and blue emitters because of faster loss of emission from green and red phosphors (i.e., a reduction in spectral efficiency). Because of an initial drop in power consumption, the light source efficiency of downlights (Products MS-4 and MS-5) increased at RTOL throughout the test duration. The light source efficiency initially increased during 75OL until a decay in luminous flux maintenance (LFM) dominated light source efficiency, whereas the light source efficiency decreased for the entire 7575 test duration. It was found that increasing the ambient environment of an SSL device from 25°C to 75°C decreases the LFM by 2.7 to 5.5, depending on design of the SSL device. Adding humidity to the system (75OL to 7575) was found to decrease LFM by another factor of approximately 3.0. A common location of failure was identified for the downlights (Products MS-4 and MS-5) operated in the 7575 environment. This failure abruptly occurred between 3,000 to 5,000 hrs of testing on the film capacitor of the electromagnetic interference (EMI) filter near the diode bridge for 11 of the 12 downlights. It is likely that this failure was caused by a combination of the high electrical voltage across the capacitor, the location of the capacitor near the heat sources (e.g., transformers, diode bridges, power resistors), and the high stress environment of 7575. Longer test times are needed to fully understand the LFM, luminous efficacy changes, and chromaticity shifts for some of the products. Because of the high reliability, light source efficiency, and spectral tuning capabilities of LEDs, the expectations of LAE for SSL products are greatly increased over traditional lighting products. The data gathered in this report begin to provide an understanding of the tradeoffs that current SSL products undergo when optimizing the different efficiency elements of LAE. As discussed in this report, the findings from the tests conducted show that the optimization of spectral efficiency can come at the cost of initial light source efficiency. Furthermore, the introduction of violet LEDs can promote long-term optical delivery efficiency degradation, and the introduction of optical filters or new phosphors can lead to unwanted spectral efficiency changes because the ratio of phosphor emitters changes with aging. The data presented in this report also identified a common failure location in 6-in downlights. The results regarding long-term behavior of the modified spectra devices studied provide valuable information about changes to the light source, spectral, and optical delivery efficiencies as the devices age. This information can be used to improve future SSL designs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mu2e Production Target Thermal Test Project

The Mu2e experiment requires a production target that is capable of operating under extreme thermal conditions caused by an 8 GeV proton beam. This project’s objective supports the development of the Mu2e Pro- duction Target by testing the Stickman model’s thermal behavior. Angel Flores Luviano has assisted Jonathan Williams in progressing this project by contributing to the development of a Radiative Cooling Test Fixture (RCTF) that will be used to evaluate the thermal behavior of the new production target model. Engineering calculations were performed to an- alyze thermal performance and pressure drop within the cold well and wa- ter cooling circuit. These calculations also determined the optimal sizing for key components of the water system. An engineering note was made to document these calculations. CAD models of the water circuit piping, thermocouple mounting bars, and radiator chimney were developed, and prototype test rig components were fabricated using 3D printing. Future work will focus on continued RCTF development which includes control system integration, heater hardware design, and interfaces that can be scaled up to increase thermal capacity.

Flores Luviano, Angel Augusto [Unlisted, US]↗

Contact Angle Measurements Using Sessile Drop and Micro-CT Data from Six Sandstones

Numerous sessile drop and micro-computed tomography (micro-CT) studies have been conducted to quantify Geologic Carbon Storage formation wettability by measuring static contact angles (θ); however, the influence of pore geometry remains unknown. In this work, six sandstones (Bandera Brown, Berea, Bentheimer, Mt. Simon, Navajo, and Nugget) are used to measure θ using the two aforementioned experimental methods at identical testing conditions (45°C and 12.41 MPa). The range of θ measured at in situ conditions (micro-CT) exceeds those the range at ex situ (sessile drop method) conditions for all sandstones. However, when droplets with more representative in situ diameters are analyzed, θ averages show ex situ θ exceed those of in situ θ. Pore geometry does influence local θ, but the size of ex situ droplets relative to pore size appears to influence θ. This is an important to consider for future sessile drop studies used for analysis of CO 2 behavior in carbon storage reservoirs.

36 MATERIALS SCIENCE↗

Sizing and Selection of Pressure Relief Valves for High-Pressure Thermal–Hydraulic Systems

This study covers the critical concerns related to the sizing, selection, installation, maintenance, and testing of pressure safety valves (PSVs). The aim is to ensure the safety of pressurized systems, hydrostatic transmission systems, and hydraulic plants, including process plants, thermal power plants, and nuclear reactor systems. PSVs are devices that ensure the safety and reliability of pressurized vessels, lines, and systems during overpressure events. The task of selecting which PSV features are of greatest value for a specific purpose is complex—especially in the design of a high-pressure experimental thermal–hydraulic facility for hydrostatic and transient testing of the reactor system—when the systems are in the design and development phases and require qualification and demonstration to prove that they have reached a given level of technological readiness. The present study highlights the required steps for users to follow the associated rules, guidelines, and recommendations. As a part of this research, case studies are presented to help readers better understand the applicable strategy and standards. A discussion and a review of PSV performance degradation and failure are summarized to provide a better understanding of varied process applications and conditions, including fluid flow dynamics, boundary-layer formation and pressure drops, gas bubble formation and collapse, geometric configurations, inlet/outlet piping, abrupt pressure fluctuations, and acoustic resonance. Moreover, this study discusses the servicing and testing of PSVs in a multiphase pressurized system. Overall, it provides a basic overview of how PSVs ensure the safety of pressurized systems, supported by case studies and industrial practices.

02 PETROLEUM↗

Helium recovery system at IB3A

The growing demand for sustainable cryogenic operations at Fermilab has underscored the need to improve helium management, particularly at the Industrial Building 3A (IB3A) test facility. IB3A characterizes and tests superconductors, cables, and coils for projects such as the HL-LHC AUP and Mu2e, yet currently relies on 500 L Dewars whose boil-off is vented to atmosphere, wasting a critical, non-renewable resource and increasing the cost of testing. A project is therefore under way to link IB3A to an existing purification and liquefaction station in a neighboring building through a dedicated pipeline. Captured helium will be transferred, purified, reliquefied, and returned for reuse, cutting losses and operating costs. This paper details the first two project phases: "Design and Engineering" and "Procurement and Installation." The design phase finalizes pipeline specifications, establishes flow-control requirements, and resolves integration challenges with existing cryogenic infrastructure. The procurement and installation phase covers material sourcing, pipeline construction, and deployment of control and monitoring systems to assure reliable, efficient operation. Key technical hurdles-route optimization, pressure drop mitigation, and interface compatibility-are discussed alongside implemented solutions. Implementing the pipeline and upgrading IB3A will dramatically reduce helium consumption and therefore testing cost, strengthening Fermilab's capacity to support frontier science far into the future.

Porwisiak, D. [Fermilab; Wroclaw Tech. U.]↗

Serial crystallography using automated drop dispensing

Automated, pulsed liquid-phase sample delivery has the potential to greatly improve the efficiency of both sample and photon use at pulsed X-ray facilities. In this work, an automated drop on demand (DOD) system that accelerates sample exchange for serial femtosecond crystallography (SFX) is demonstrated. Four different protein crystal slurries were tested, and this technique is further improved here with an automatic sample-cycling system whose effectiveness was verified by the indexing results. Here, high-throughput SFX screening is shown to be possible at free-electron laser facilities with very low risk of cross contamination and minimal downtime. The development of this technique will significantly reduce sample consumption and enable structure determination of proteins that are difficult to crystallize in large quantities. This work also lays the foundation for automating sample delivery.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Numerical Simulations in Support of a Long-Term Test of Gas Production from Hydrate Accumulations on the Alaska North Slope: Reservoir Response to Interruptions of Production (Shut-Ins)

In this work, we investigate by means of numerical simulation a planned year-long field test of depressurization-induced production from a permafrost-associated hydrate reservoir on the Alaska North Slope at the site of the recently drilled Hydrate-01 Stratigraphic Test Well. The main objective of this study is to assess quantitatively the impact of temporary interruptions (well shut-ins) on the expected fluid production performance from the B1 Sand of the stratigraphic Unit B during controlled depressurization over different time scales, as well as on other relevant aspects of the system response that have the potential to significantly affect the design of the field test. We consider eight different cases of depressurization, including (a) rapid depressurization over a 60-day period to a terminal bottomhole pressure P W of 2.8 MPa and (b) a slower depressurization rate to a final P W of 0.6 MPa at the end of the year-long production test, in addition to (c) a multi-step depressurization regime and (d) a quasi-linear continuous depressurization strategy. The results of the study indicate that shut-ins obviously reduce gas release and production during and immediately after their occurrence, but their longer-term effects are strongly dependent on the depressurization regime and on the time of observation, covering the entire range of potential outcomes. Shut-ins (a) have a universally strong negative effect when quasi-linear depressurization is involved regardless of the length of the production period, and (b) have a strong positive effect in multi-step depressurization schemes that becomes apparent earlier for large initial pressure drops, but (c) can also appear to have practically no effect for slow stepwise depressurization at the end of the year-long production test. Shut-ins lead to a rapid reformation of hydrates, even to the point of disappearance of a free gas phase in the reservoir. Rapid depressurization regimes lead to early maximum rates of hydrate dissociation and gas production, while the maximum rates occur at the end of the production test for the cases of slower depressurization. Shut-ins do not appear to have a significant impact on water production, as the cessation of production is followed by higher rates production when depressurization resumes. Similarly, (a) the fraction of produced CH 4 originating from exsolution from the water, (b) the water-to-gas ratio, and (c) the rate of replenishment of produced water by boundary inflows do not appear significantly affected by shut-ins, the effects of which seem to be temporary in the majority of the cases. The study confirmed the superiority of multi-step depressurization methods as the most effective strategies for hydrate dissociation and gas production and showed that two observation wells (located at distances of 30 and 50 m from the production well) are appropriately positioned and both able to capture the P, T, and S G behavior during the fluid production and shut-ins in any of the eight cases we investigated.

03 NATURAL GAS↗

Enhanced rare earth element recovery with cross-linked glutaraldehyde-lanthanide binding peptides in foam-based separations

Lanthanide Binding Tag (LBT) peptides that coordinate selectively with lanthanide ions can be used to replace the energy intensive processes used for the separation of rare earth elements (REEs). These surface-active biomolecules, once selectively complexed with the trivalent REE cations, can adsorb to air/aqueous interfaces of bubbles for foam-based REEs recovery. Glutaraldehyde, an organic compound that is a homobifunctional crosslinker for proteins and peptides, can be used to enhance the adsorption and interfacial stabilization of lanthanide-bound peptides films. The stability of the interfacial cross-linked films was tested by measuring their dilational and shear surface rheological properties. Surface activity of the adsorbed species was analyzed using pendant drop tensiometry, while surface density and molecular arrangement were determined using x-ray reflectivity and x-ray fluorescence near total reflection. Glutaraldehyde cross-linked REE-peptide complexes enhance the adsorption of lanthanides to air-water interfaces, resulting in thicker interfacial structures. Subsequently, these thicker layers enhance the dilational and shear interfacial rheological properties. The interfacial film stabilization and REEs extraction promoted by the cross-linker presented in this work provides an approach to integrate glutaraldehyde as a substitute of common foam stabilizers such as polymers, surfactants, and particles to optimize the recovery of REEs when using biomolecules as extractants.

36 MATERIALS SCIENCE↗