Search NASA⌕ Search

SEARCH · Search NASA

Results for “EFS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

THE PHYSICAL ENVIRONMENT AROUND IRAS 17599–2148: INFRARED DARK CLOUD AND BIPOLAR NEBULA

We present a multiscale and multiwavelength study to investigate the star formation process around IRAS 17599–2148, which is part of an elongated filamentary structure (EFS) (extension ∼21 pc) seen in the Herschel maps. Using the Herschel data analysis, at least six massive clumps (M {sub clump} ∼ 777–7024 M {sub ⊙}) are found in the EFS with a range of temperature and column density of ∼16–39 K and ∼(0.6–11) × 10{sup 22} cm{sup −2} (A {sub V} ∼ 7–117 mag), respectively. The EFS hosts cold gas regions (i.e., infrared dark cloud) without any radio detection and a bipolar nebula (BN) linked with the H ii region IRAS 17599–2148, tracing two distinct environments inferred through the temperature distribution and ionized emission. Based on virial analysis and higher values of self-gravitating pressure, the clumps are found unstable against gravitational collapse. We find 474 young stellar objects (YSOs) in the selected region, and ∼72% of these YSOs are found in the clusters distributed mainly toward the clumps in the EFS. These YSOs might have spontaneously formed due to processes not related to the expanding H ii region. At the edges of BN, four additional clumps are also associated with YSO clusters, which appear to be influenced by the expanding H ii region. The most massive clump in the EFS contains two compact radio sources traced in the Giant Metre-wave Radio Telescope 1.28 GHz map and a massive protostar candidate, IRS 1, prior to an ultracompact H ii phase. Using the Very Large Telescope/NACO near-infrared images, IRS 1 is resolved with a jet-like feature within a 4200 au scale.

79 ASTRONOMY AND ASTROPHYSICS↗

Vertical dependence of horizontal variation of cloud microphysics: observations from the ACE-ENA field campaign and implications for warm-rain simulation in climate models

Abstract. In the current global climate models (GCMs), the nonlinearity effect of subgrid cloud variations on the parameterization of warm-rain process, e.g., the autoconversion rate, is often treated by multiplying the resolved-scale warm-rain process rates by a so-called enhancement factor (EF). In this study, we investigate the subgrid-scale horizontal variations and covariation of cloud water content (qc) and cloud droplet number concentration (Nc) in marine boundary layer (MBL) clouds based on the in situ measurements from a recent field campaign and study the implications for the autoconversion rate EF in GCMs. Based on a few carefully selected cases from the field campaign, we found that in contrast to the enhancing effect of qc and Nc variations that tends to make EF > 1, the strong positive correlation between qc and Nc results in a suppressing effect that tends to make EF < 1. This effect is especially strong at cloud top, where the qc and Nc correlation can be as high as 0.95. We also found that the physically complete EF that accounts for the covariation of qc and Nc is significantly smaller than its counterpart that accounts only for the subgrid variation of qc, especially at cloud top. Although this study is based on limited cases, it suggests that the subgrid variations of Nc and its correlation with qc both need to be considered for an accurate simulation of the autoconversion process in GCMs.

54 ENVIRONMENTAL SCIENCES↗

Circadian rhythm dissociation in an environment with conflicting temporal information

The relative contributions of light-dark (LD) cycles and eating-fasting (EF) cycles in providing temporal information to the circadian time-keeping system were examined in chair-acclimatized squirrel monkeys (Saimiri sciureus). The circadian rhythms of drinking, colonic temperature, urine volume, and urinary potassium excretion were measured with the LD and EF cycles providing either conflicting phases or periods. In conflicting phase experiments, animals were exposed to 24-hr LD cycles consisting of 12 hr of 600 lx followed by 12 hr of less than 1 lx and concurrent 24-hr EF cycles in which the animals ate for 3 hr and then fasted for 21 hr. One group had food available at the beginning and a second group at the end of the light period. In conflicting period experiments, monkeys were exposed to 23-hr LD cycles and 24-hr EF cycles. Analysis of the rhythms showed that both phase and period information were conveyed to the drinking and urinary rhythms by the EF cycle, and to the temperature rhythm by the LD cycle.

Sulzman, F. M.↗

Airborne Measurements of Western U.S. Wildfire Emissions: Comparison with Prescribed Burning and Air Quality Implications

Wildfires emit significant amounts of pollutants that degrade air quality. Plumes from three wildfires in the western U.S. were measured from aircraft during the Studies of Emissions and Atmospheric Composition, Clouds and Climate Coupling by Regional Surveys (SEAC4RS) and the Biomass Burning Observation Project (BBOP), both in summer 2013. This study reports an extensive set of emission factors (EFs) for over 80 gases and 5 components of submicron particulate matter (PM1) from these temperate wildfires. These include rarely, or never before, measured oxygenated volatile organic compounds and multifunctional organic nitrates. The observed EFs are compared with previous measurements of temperate wildfires, boreal forest fires, and temperate prescribed fires. The wildfires emitted high amounts of PM1 (with organic aerosol (OA) dominating the mass) with an average EF that is more than 2 times the EFs for prescribed fires. The measured EFs were used to estimate the annual wildfire emissions of carbon monoxide, nitrogen oxides, total non methane organic compounds, and PM1 from 11 western U.S. states. The estimated gas emissions are generally comparable with the 2011 National Emissions Inventory (NEI). However, our PM1 emission estimate (1530 +/- 570 Gg/yr) is over 3 times that of the NEI PM2.5 estimate and is also higher than the PM2.5 emitted from all other sources in these states in the NEI. This study indicates that the source of OA from biomass burning in the western states is significantly underestimated. In addition, our results indicate that prescribed burning may be an effective method to reduce fine particle emissions.

measured oxygenated volatile organic compounds↗

Comparing the Regional Variability of Emission Factors of Greenhouse Gases Over Different Landscape During FIREX-AQ Campaign

Biomass burning (wildfires, prescribed and agricultural burning) is one of the major sources of trace gases and particulate emissions and annual variability in growth rates. Biomass burning can impact local, regional, and global air quality, as well as climate. Measurements of emissions from biomass burning are crucial to a better understanding of how it influences and interacts with biogeochemical cycles. High resolution in-situ measurements were recorded onboard the NASA DC-8 aircraft during the FIREX-AQ (Fire Influence on Regional to Global Environments and Air Quality) airborne field campaign July-September, 2019, which was conducted over the continental U.S. Fire emission factors (EF) are essential input for emissions models used to develop biomass burning emission inventories. Here we present the Emission Ratio (ER), MCE (Modified Combustion Efficiency), and EF (Emission Factor) of CO2, CO, and CH4, which constitute the majority of carbon emitted from the wildland, prescribed, and agricultural fires. EFCO2, EFCO, and EFCH4 from the Wildland fires at Williams Flats, WA (primarily Douglas Fir, Ponderosa pine, wheatgrass: 50-75%), ranged from 1527 – 1820 g/kg (Avg. 1641±42), 6.5 – 174.1 g/kg (110.5±24.1), and 0.7 – 11.3 g/kg (6.2±1.9), respectively. EFs from the Arizona CASTLE fire, with somewhat different fuel sources (primarily Ponderosa pine, Douglas fir: 40-70%) ranged from 1266 – 1667 g/kg (1596±59), 99.5 – 344.5 g/kg (136.7±36.8), and 0.4 – 9.2 g/kg (7.2±1.7), respectively. Another primary driver of EFs is likely fire weather. Detailed variability of greenhouse gas EFs will be examined and presented in accordance with different fuels and fire conditions at burned areas, specifically within unique wildland and croplands, using the FCCS (Fuel Characteristic Classification System) 30m land cover identification and the Cropland Data Layer (CDL).

Biomass burning↗

Comparing the regional variability of emission factors of greenhouse gases over different landscape during FIREX-AQ campaign

Biomass burning (wildfires, prescribed and agricultural burning) is one of the major sources of trace gases and particulate emissions and annual variability in growth rates. Biomass burning can impact local, regional, and global air quality, as well as climate. Measurements of emissions from biomass burning are crucial to a better understanding of how it influences and interacts with biogeochemical cycles. High resolution in-situ measurements were recorded onboard the NASA DC-8 aircraft during the FIREX-AQ (Fire Influence on Regional to Global Environments and Air Quality) airborne field campaign July-September, 2019, which was conducted over the continental U.S. Fire emission factors (EF) are essential input for emissions models used to develop biomass burning emission inventories. Here we present the Emission Ratio (ER), MCE (Modified Combustion Efficiency), and EF (Emission Factor) of CO2, CO, and CH4, which constitute the majority of carbon emitted from the wildland, prescribed, and agricultural fires. EFCO2, EFCO, and EFCH4 from the Wildland fires at Williams Flats, WA (primarily Douglas Fir, Ponderosa pine, wheatgrass: 50-75%), ranged from 1527 – 1820 g/kg (Avg. 1641±42), 6.5 – 174.1 g/kg (110.5±24.1), and 0.7 – 11.3 g/kg (6.2±1.9), respectively. EFs from the Arizona CASTLE fire, with somewhat different fuel sources (primarily Ponderosa pine, Douglas fir: 40-70%) ranged from 1266 – 1667 g/kg (1596±59), 99.5 – 344.5 g/kg (136.7±36.8), and 0.4 – 9.2 g/kg (7.2±1.7), respectively. Another primary driver of EFs is likely fire weather. Detailed variability of greenhouse gas EFs will be examined and presented in accordance with different fuels and fire conditions at burned areas, specifically within unique wildland and croplands, using the FCCS (Fuel Characteristic Classification System) 30m land cover identification and the Cropland Data Layer (CDL).

Biomass burning↗

Emission Factors for Crop Residue and Prescribed Fires in the Eastern US during FIREX-AQ

Agricultural and prescribed burning activities emit large amounts of trace gases and aerosols on regional to global scales. We present a compilation of emission factors (EFs) and emission ratios (ERs) from the eastern portion of the Fire Influence on Regional to Global Environments and Air Quality (FIREX-AQ) campaign in 2019 in the United States, which sampled burning of crop residues and other prescribed fire fuels. FIREX-AQ provided comprehensive chemical characterization of 53 crop residue and 22 prescribed fires. Crop residues burned at different modified combustion efficiencies (MCE), with corn residue burning at higher MCE than other fuel types. Prescribed fires burned at lower MCE (<0.90) which is typical, while grasslands burned at lower MCE (0.90) than normally observed due to moist, green, growing season fuels. Most non-methane volatile organic compounds (NMVOCs) were significantly anticorrelated with MCE except for ethanol and NMVOCs that were measured with less certainty. We identified 23 species where crop residue fires differed by more than 50% from prescribed fires at the same MCE. Crop residue EFs were greater for species related to agricultural chemical use and fuel composition as well as oxygenated NMVOCs possibly due to the presence of metals such as potassium. Prescribed EFs were greater for monoterpenes (5×). FIREX-AQ crop residue average EFs generally agreed with the previous agricultural fire study in the US but had large disagreements with global compilations. FIREX-AQ observations show the importance of regionally-specific and fuel-specific EFs as first steps to reduce uncertainty in modeling the air quality impacts of fire emissions.

air quality↗

Emission characteristics of carbonaceous particles from various residential coal-stoves in China

China is thought to be the most important contributor to the global burden of carbonaceous aerosols, and residential coal combustion is the greatest emission source of black carbon (BC). In the present study, two high-efficiency household coal-stoves are tested together with honeycomb-coal-briquettes and raw-coal-chunks of nine different coals. Coal-burning emissions are collected onto quartz fiber filters (QFFs) and analyzed by a thermal-optical transmittance (TOT) method. Emission factors (EFs) of particulate matter (PM), organic carbon (OC), and elemental carbon (EC) are systematically measured, and the average EFs are calculated by taking into account our previous data. For bituminous coal-briquette and -chunk, EFs of PM, OC, and EC are 7.33, 4.16, and 0.08 g/kg and 14.8, 5.93, and 3.81 g/kg, respectively; and for anthracite-briquette and -chunk, they are 1.21, 0.06, and 0.004 g/kg and 1.08, 0.10, and 0.007 g/kg, respectively. Annual estimates for PM, OC, and EC emissions in China are calculated for the years of 2000 and 2005 according to the EFs and coal consumptions, and the results are consistent with our previous estimates. Bituminous coal-chunk contributes 68% and 99% of the total OC and EC emissions from household coal burning, respectively. Additionally, a new model of Aethalometer (AE90) is introduced into the sampling system to monitor the real-time BC concentrations. On one hand, AE90 provides a set of EFs for optical BC in parallel to thermal-optical EC, and these two data are generally comparable, although BC/EC ratios vary in different coal/stove combinations. On the other hand, AE90 offers a chance to observe the variation of BC concentrations during whole burning cycles, which demonstrates that almost all BC emits into the flue during the initial period of 15 min after coal addition into household stoves. 23 refs., 2 figs., 3 tabs.

01 COAL, LIGNITE, AND PEAT↗

Complex Evolutionary History of Translation Elongation Factor 2 and Diphthamide Biosynthesis in Archaea and Parabasalids

Diphthamide is a modified histidine residue which is uniquely present in archaeal and eukaryotic elongation factor 2 (EF-2), an essential GTPase responsible for catalyzing the coordinated translocation of tRNA and mRNA through the ribosome. In part due to the role of diphthamide in maintaining translational fidelity, it was previously assumed that diphthamide biosynthesis genes (dph) are conserved across all eukaryotes and archaea. Here, comparative analysis of new and existing genomes reveals that some archaea (i.e., members of the Asgard superphylum, Geoarchaea, and Korarchaeota) and eukaryotes (i.e., parabasalids) lack dph. In addition, while EF-2 was thought to exist as a single copy in archaea, many of these dph-lacking archaeal genomes encode a second EF-2 paralog missing key residues required for diphthamide modification and for normal translocase function, perhaps suggesting functional divergence linked to loss of diphthamide biosynthesis. Interestingly, some Heimdallarchaeota previously suggested to be most closely related to the eukaryotic ancestor maintain dph genes and a single gene encoding canonical EF-2. Our findings reveal that the ability to produce diphthamide, once thought to be a universal feature in archaea and eukaryotes, has been lost multiple times during evolution, and suggest that anticipated compensatory mechanisms evolved independently.

59 BASIC BIOLOGICAL SCIENCES↗

Electrification Futures Study Flexible Load Profiles

This data set includes hourly profiles for flexible load developed for the Electrification Futures Study (EFS). The load profiles represent projected end-use electricity demand that is assumed to be flexible (i.e., can be shifted throughout a day) for various scenarios of flexibility (Base, Enhanced), electrification (Reference, Medium, High), and technology advancement (Slow, Moderate, Rapid), and were developed as inputs into the ReEDS model. The quantity of flexible load is estimated using assumptions on the level of flexibility and customer participation within each subsector modeled in the EFS. Detailed assumptions and modeling implementation will be documented in ongoing EFS analyses. Flexible load profiles are provided for a subset of years (2018, 2020, 2024, 2030, 2040, 2050) and are aggregated to the state and sector level. Total electricity load profiles can be found in a related EFS data set (https://dx.doi.org/10.7799/1593122). NOTE: Due to the file size, Mac users may experience issues decompressing the zip files using the Mac Archive Utility. In those cases, decompressing using the command line is recommended. - Mai, Trieu, Paige Jadun, Jeffrey Logan, Colin McMillan, Matteo Muratori, Daniel Steinberg, Laura Vimmerstedt, Ryan Jones, Benjamin Haley, and Brent Nelson. 2018. Electrification Futures Study: Scenarios of Electric Technology Adoption and Power Consumption for the United States. National Renewable Energy Laboratory. NREL/TP-6A20-71500. https://doi.org/10.2172/1459351. - Murphy, Caitlin, Trieu Mai, Yinong Sun, Paige Jadun, Matteo Muratori, Brent Nelson, Ryan Jones. Forthcoming. Electrification Futures Study: Scenarios of Power System Evolution and Infrastructure Development for the United States. National Renewable Energy Laboratory. - Sun, Yinong, Paige Jadun, Brent Nelson, Matteo Muratori, Caitlin Murphy, Jeffrey Logan, and Trieu Mai. Forthcoming. Electrification Futures Study: Methodological Approaches for Assessing Long-Term Power System Impacts of End-Use Electrification. National Renewable Energy Laboratory.

buildings↗

Impact of imaging protocol on left ventricular ejection fraction using gated-SPECT myocardial perfusion imaging

Background: There are limited data on the impact of the imaging protocol (single-day stress-rest, SD, vs. dual-day, DD) on the change in left ventricular (LV) ejection fraction (EF) (post-stress-rest) in relation to ischemia and on outcome. Methods: Using propensity score matching procedure, 490 of 1121 patients with known CAD, undergoing a SD or a DD in a multicenter study, were evaluated. Stress and rest gated-SPECT myocardial perfusion imaging was used to quantify LV perfusion, EF, and volumes. Outcome was assessed at an average follow-up time of 3.2 years. Results: Post-stress LVEF in SD and DD were comparable across all degrees of ischemia. The change in LVEF in patients with severe ischemia was, however, higher in the DD protocol, independent of the extent of CAD. At follow-up, 240 patients (49.0%) required coronary revascularization (CR) and 52 patients (10.6%) had hard events. The ischemic burden was independently associated with CR and hard-events; the post-stress LVEF was associated with CR but the change in EF was not predictive of either CR or hard events. Conclusions: In patients with severe ischemia, underestimation of post-stress myocardial stunning could be observed with the SD protocol. Post-stress LVEF and the extent ischemia, but not the change in EF, are predictive of CR and hard events.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reducing the small-heart effect in pediatric gated myocardial perfusion single-photon emission computed tomography

Background: We compared two reconstruction algorisms and two cardiac functional evaluation software programs in terms of their accuracy for estimating ejection fraction (EF) of small hearts (SH). Methods: The study group consisted of 66 pediatric patients. Data were reconstructed using a filtered back projection (FBP) method without the resolution correction (RC) and an iterative method based on an ordered subset expectation maximization (OSEM) algorithm with the RC. EF was evaluated using two software programs of quantitative gated single-photon emission computed tomography (SPECT) (QGS) and cardioREPO. We compared the EF of gated myocardial perfusion SPECT to echocardiographic measurement (Echo). Results: Forty-eight of 66 patients had an end-systolic volume < 20 mL which was used as the criterion for being included in the SH group, and the SH effect led to an overestimation of EF. While significant differences were observed between Echo (66.9 ± 5.0%) and QGS-FBP without RC (76.9 ± 8.4%, P < .0001), QGS-OSEM with RC (76.6 ± 8.6%, P < .0001), and cardioREPO-FBP without RC (72.1 ± 10.0%, P = .0011), no significant difference was observed between Echo and cardioREPO-OSEM with RC (67.4 ± 6.1%) in SH group. Conclusions: In pediatric gated myocardial perfusion SPECT, the SH effect can be significantly reduced when an OSEM algorithm is used with RC in combination with the specific cardioREPO algorithm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Greenhouse gas emissions from the enteric fermentation and manure storage of dairy and beef cattle in China during 1961–2010

Due to the expanding dairy and beef population in China and their contribution to global CH{sub 4} and N{sub 2}O budgets, a framework considering changes in feed, manure management and herd structure was established to indicate the trends of CH{sub 4} and N{sub 2}O emissions from the enteric formation and manure storage in China's beef and dairy production and the underlying driving forces during the period 1961–2010. From 1961 to 2010, annual CH{sub 4} and N{sub 2}O emissions from beef cattle in China increased from 2.18 Mt to 5.86 Mt and from 7.93 kt–29.56 kt, respectively, while those from dairy cattle increased from 0.023 to 1.09 Mt and 0.12 to 7.90 kt, respectively. These increases were attributed to the combined changes in cattle population and management practices in feeds and manure storage. Improvement in cattle genetics during the period increased the bodyweight, required dry matter intake and gross energy and thus resulted in increased enteric CH{sub 4} EFs for each category of beef and dairy cattle as well as the overall enteric EFs (i.e., Tier 1 in IPCC). However, for beef cattle, such an impact on the overall enteric EFs was largely offset by the herd structure transition from draft animal-oriented to meat animal-oriented during 1961–2010. Although the CO{sub 2}-eq of CH{sub 4} and N{sub 2}O from manure storage was less than the enteric emissions during 1961–2010 in China, it tended to increase both in beef and dairy cattle, which was mainly driven by the changes in manure management practices. - Highlights: • CH{sub 4} emissions dominated the CO{sub 2}-eq emissions from dairy and beef cattle in China. • Beef herd transition played an important role in CH{sub 4} emissions. • Changes of manure managements increased the manure EFs of CH{sub 4} and N{sub 2}O. • Manure contributed very less to the total CO{sub 2}-eq emissions but tended to grow.

54 ENVIRONMENTAL SCIENCES↗

Systematic review of biological effects of exposure to static electric fields. Part II: Invertebrates and plants

Highlights: • Environmental impacts of static EF were assessed in invertebrate and plant studies. • Invertebrates are able to perceive the presence of static EF near HVDC power lines. • No evidence for adverse effects on physiological functions at HVDC field levels. • Corona-action appears to cause adverse biological effects at very high field levels. • Methodological flaws in all reviewed studies lowered credibility in the results. The construction of high-voltage direct current (HVDC) lines for the long-distance transport of energy is becoming increasingly popular. This has raised public concern about potential environmental impacts of the static electric fields (EF) produced under and near HVDC power lines. As the second part of a comprehensive literature analysis, the aim of this systematic review was to assess the effects of static EF exposure on biological functions in invertebrates and plants and to provide the basis for an environmental impact assessment of such exposures.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

The effect of flavor content in e-liquids on e-cigarette emissions of carbonyl compounds

Highlights: • Electronic cigarettes (e-cigarettes or ECs) are designed to deliver nicotine to a smoker. • The flavorings in e-liquids were considered safe but raised concerns due to potential toxicity. • In this study, we investigated the effects of flavor content on CC emissions from EC vaping. • The CC amounts (before/during vaping) was estimated from the flavor content in the e-liquid. • The effects of flavor content in e-liquids on vaping CC emissions warrant attention. The effect of flavors on carbonyl compound (CC) emission factors (EF) from electronic cigarettes (ECs) vaping was investigated at the default vaping (voltage) setting in all experiments using a total of 21 lab-made e-liquid samples (five different types of retail flavorant bases: beverage/dessert/fruit/mint/tobacco). Each flavorant base was added to a separate unflavored base composed of a 1:1 mixture of propylene glycol/vegetable glycerol (PG/VG) at four levels (5/10/30/50% (v/v)). The e-liquid CC levels increased linearly with flavorant base content, 1.3–10.5 times (R{sup 2}: 0.762–0.999). The vaping CC EFs increased linearly with flavorant base content (if ≥ 10%) from 1.0 to 92 times (R{sup 2}: 0.431–0.998). For flavorant base content of 0%, 5%, and 10%, the EFs ranged from undetected to 0.11 μg puff{sup −1} (acetone). The 40-year cancer risk due to formaldehyde (70 kg EC user inhaling 5% flavorant base content e-liquid: 120 puffs day{sup −1}) is estimated to be 2.0E-06 (highest) compared to 1.0E-06 for the 1:1 PG:VG base. Most formaldehyde vaped from the fruit flavored e-liquid was the flavorant base. The CC concentrations in EC liquids (before vaping) were approximately linear with e-liquid flavorant base content. Retail e-liquid product information labels should be guided to provide a complete list of all ingredients, their concentrations, and carbonyl compound EFs.

54 ENVIRONMENTAL SCIENCES↗

Emissions of particulate matter, carbon monoxide and nitrogen oxides from the residential burning of waste paper briquettes and other fuels

Highlights: • The first attempt to report emission of key air pollutants from waste paper briquettes. • Burning of paper briquettes emitted relatively high CO and NO{sub x} concentration. • Burning of paper briquettes emitted PM with large average particle size. • Waste paper could be recycled as briquettes for domestic use like other common fuels. Using waste paper as fuel for domestic heating is a beneficial recycling option for small island developing states where there are lacks of resources for energy and waste treatment. However, there are concerns about the impact of air pollutants emitted from the burning of the self-made paper briquettes as household air pollution is recognised as the greatest environmental risk for human. In this study, combustion tests were carried out for paper briquettes made in one Pacific island and three commercial fuels in Australia including wood briquettes, kindling firewood and coal briquettes in order to: 1) characterise the emissions of three criteria air pollutants including particulate matters, CO and NO{sub x} including their emission factors (EF) from the tested fuels; and 2) compare the EFs among the tested fuels and with others reported in the literature. The results showed that waste paper briquettes burned quickly and generated high temperature but the heat value is relatively low. Paper briquettes and coal briquettes produced higher CO concentration than the others while paper briquettes generated the highest NO{sub x} level. Only PM{sub 2.5} concentration emitted from paper briquettes was similar to kindling firewood and lower than wood briquettes. Burning of paper briquettes and wood briquettes produced particulate matter with large average count median diameter (72 and 68 nm) than coal briquette and kindling firewood (45 and 51 nm). The EFs for CO, NO{sub x} and PM{sub 2.5} of paper briquettes were within the range of EFs reported in this study as well as in the literature. Overall, the results suggested that using paper briquettes as fuel for domestic heating will not likely to generate higher level of three major air pollutants compared to other traditional fuels.

54 ENVIRONMENTAL SCIENCES↗

Is There a Dose-Response Relationship for Heart Disease With Low-Dose Radiation Therapy?

Purpose: To quantify cardiac radiation therapy (RT) exposure using sensitive measures of cardiac dysfunction; and to correlate dysfunction with heart doses, in the setting of adjuvant RT for left-sided breast cancer. Methods and Materials: On a randomized trial, 32 women with node-positive left-sided breast cancer underwent pre-RT stress single photon emission computed tomography (SPECT-CT) myocardial perfusion scans. Patients received RT to the breast/chest wall and regional lymph nodes to doses of 50 to 52.2 Gy. Repeat SPECT-CT scans were performed 1 year after RT. Perfusion defects (PD), summed stress defects scores (SSS), and ejection fractions (EF) were evaluated. Doses to the heart and coronary arteries were quantified. Results: The mean difference in pre- and post-RT PD was −0.38% ± 3.20% (P=.68), with no clinically significant defects. To assess for subclinical effects, PD were also examined using a 1.5-SD below the normal mean threshold, with a mean difference of 2.53% ± 12.57% (P=.38). The mean differences in SSS and EF before and after RT were 0.78% ± 2.50% (P=.08) and 1.75% ± 7.29% (P=.39), respectively. The average heart Dmean and D95 were 2.82 Gy (range, 1.11-6.06 Gy) and 0.90 Gy (range, 0.13-2.17 Gy), respectively. The average Dmean and D95 to the left anterior descending artery were 7.22 Gy (range, 2.58-18.05 Gy) and 3.22 Gy (range, 1.23-6.86 Gy), respectively. No correlations were found between cardiac doses and changes in PD, SSS, and EF. Conclusions: Using sensitive measures of cardiac function, no clinically significant defects were found after RT, with the average heart Dmean <5 Gy. Although a dose response may exist for measures of cardiac dysfunction at higher doses, no correlation was found in the present study for low doses delivered to cardiac structures and perfusion, SSS, or EF.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Whole Lung Irradiation for Adults With Pulmonary Metastases From Ewing Sarcoma

Purpose: To evaluate feasibility and patterns of failure in adult patients with Ewing sarcoma (ES) treated with whole lung irradiation (WLI) for pulmonary metastases. Methods and Materials: Retrospective review of all ES patients treated at age 18 or older with 12-15 Gy WLI for pulmonary metastases at a single institution between 1990 and 2014. Twenty-six patients met the study criteria. Results: The median age at WLI was 23 years (range, 18-40). The median follow-up time of the surviving patients was 3.8 years (range, 1.0-9.6). The 3-year cumulative incidence of pulmonary relapse (PR) was 55%, with a 3-year cumulative incidence of PR as the site of first relapse of 42%. The 3-year event-free survival (EFS) and overall survival (OS) were 38 and 45%, respectively. Patients with exclusively pulmonary metastases had better outcomes than did those with extrapulmonary metastases: the 3-year PR was 45% in those with exclusively lung metastases versus 76% in those with extrapulmonary metastases (P=.01); the 3-year EFS was 49% versus 14% (P=.003); and the 3-year OS was 61% versus 13% (P=.009). Smoking status was a significant prognostic factor for EFS: the 3-year EFS was 61% in nonsmokers versus 11% in smokers (P=.04). Two patients experienced herpes zoster in the radiation field 6 and 12 weeks after radiation. No patients experienced pneumonitis or cardiac toxicity, and no significant acute or late sequelae were observed among the survivors. Conclusion: WLI in adult patients with ES and lung metastases is well tolerated and is associated with freedom from PR of 45% at 3 years. Given its acceptable toxicity and potential therapeutic effect, WLI for pulmonary metastases in ES should be considered for adults, as it is in pediatric patients. All patients should be advised to quit smoking before receiving WLI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗