Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTRIC CONTACT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Electrical self-aligning connector

A self-aligning electrical connector device includes a receptacle component having a conically contoured interior and a plug component having a correspondingly contoured conical body receivable in the receptacle component. The plug component has a number of spaced conductive ring elements with a mating face and the receptacle component includes corresponding spaced conductive ring elements providing mating interface with the mating face of the ring elements of the plug component when connected to it. Each ring element of the receptacle component has several segmented portions which defect downwardly when the plug component is inserted. A biasing force is asserted against the face of the ring elements of the plug component providing positive electrical contact and connection between the ring elements of the components.

Clark, K. H.↗

Reed-Switch Position Indicator

Indicator for valves or other control mechanisms easy to mount, reliable, and explosion proof. Replaces slidewires expensive and difficult to mount. Used in hazardous areas that require nonexplosive electrical contacts, and controlling highly flammable fuels. Readily adapted to oil-refining and other chemical processing plants.

Winner, F. E.↗

Measuring Carrier Lifetime in GaAs by Luminescence

Luminescence proposed as nondestructive technique for measuring Shockley-Read-Hall (SRH) recombination lifetime GaAs. Sample irradiated, and luminescence escapes through surface. Measurement requires no mechanical or electrical contact with sample. No ohmic contacts or p/n junctions needed. Sample not scrapped after tested.

Von Roos, O.↗

Electromagnetic Hammer for Metalworking

High eddy currents apply pressure for cold-forming. Coil housing constructed for mechanical strength to hold coil against magnetic force, to maintain electrical contact with coil ends, and to maintain insulation between coil turns. Drilled holes placed to facilitate release of bubbles during potting. In contrast with mechanical hammers, electromagnetic hammer requires no dynamic material contact with workpiece; consequently, produces almost no change in metal grain structure.

Anderson, S. A.↗

Electrodynamic interactions

The electrodynamic interaction of long metallic tethers with the ionosphere is introduced. Due to the tether's motion across the Earth's field, a polarization electric field is generated along the tether. In a system like the Tethered Satellite System (TSS) where the tether is coated with dielectric and the electrical contact is between its two terminations and the ionosphere, the upper end termination will collect electrons and, in a passive system, the lower end termination will collect ions. Space charge regions will develop around the two terminations of the system, which can be at considerable potential with respect to the unperturbed ionospheric plasma and the current in the tether will be most significantly determined by local processes in such space charge regions. A qualitative view of the global perturbation induced by TSS in the ionosphere is outlined. One of the applications of electrodynamic tethers is that of using them as low frequency wave generators to communicate to the Earth. This application is briefly discussed. An equivalent circuit of the tether system is described. The basic equation of the circuit is given.

Dobrowolny, M.↗

Photocurrent images of amorphous-silicon solar-cell modules

Results obtained in applying the unique characteristics of the solar cell laser scanner to investigate the defects and quality of amorphous silicon cells are presented. It is concluded that solar cell laser scanners can be effectively used to nondestructively test not only active defects but also the cell quality and integrity of electrical contacts.

Kim, Q.↗

Experimental verification of distributed piezoelectric actuators for use in precision space structures

An analytic model for structures with distributed piezoelectric actuators is experimentally verified for the cases of both surface-bonded and embedded actuators. A technique for the selection of such piezoelectric actuators' location has been developed, and is noted to indicate that segmented actuators are always more effective than continuous ones, since the output of each can be individually controlled. Manufacturing techniques for the bonding or embedding of segmented piezoelectric actuators are also developed which allow independent electrical contact to be made with each actuator. Static tests have been conducted to determine how the elastic properties of the composite are affected by the presence of an embedded actuator, for the case of glass/epoxy laminates.

Crawley, E. F.↗

Convenient mounting method for electrical measurements of thin samples

A method for mounting thin samples for electrical measurements is described. The technique is based on a vacuum chuck concept in which the vacuum chuck simultaneously holds the sample and established electrical contact. The mounting plate is composed of a glass-ceramic insulating material and the surfaces of the plate and vacuum chuck are polished. The operation of the vacuum chuck is examined. The contacts on the sample and mounting plate, which are sputter-deposited through metal masks, are analyzed. The mounting method was utilized for van der Pauw measurements.

Matus, L. G.↗

Surface modification strategies for (100)3C-SiC

Several surface modificaation techniques were performed in situ in an ultrahigh vacuum as part of a program to develop electrical contacts on the (100) face of cubic SiC. The Auger electron spectroscopy line shapes and peak-to-peak heights of the Si LVV and CKLL transitions indicated changes in surface stoichiometry, bonding, and short range order. Changes in the low-energy electron diffraction pattern identified changes in the symmetry of long range ordering on the surface. Heating above 1050 C depleted the surface of Si with an activation energy of 120 kcal/mol, resulting eventually in a disordered graphitic layer which was several atomic layers thick. Bombardment by Ar ions of energies greater than 1000 eV enhanced the Si to C ratio on the surface and destroyed the LEED pattern. Long range order was recovered by simultaneous heating and ion bombardment. Finally, adsorption of Cr on the Ar ion damaged surface and subsequent desorption left a reconstructed, p(2 x 1)Si enriched surface. Similar treatments with Al did not produce a surface reconstruction.

Bellina, J. J., Jr.↗

Investigation of beam-plasma interactions

Data from the SCATHA satellite was analyzed to solve the problems of establishing electrical contact between a satellite and the ambient plasma. The original focus of the work was the electron gun experiments conducted near the geosynchronous orbit, which resulted in observations which bore a startling similarity to observations of the SEPAC experiments on SPACELAB 1. The study has evolved to include the ion gun experiments on SCATHA, a modest laboratory effort in hollow cathode performance, and preparation for flight experiments pertinent to tether technology. These areas are addressed separately.

Olsen, Richard C.↗

Plasma motor generator system

The significant potential advantages of a plasma motor generator system over conventional systems for the generation of electrical power and propulsion for spacecraft in low Earth orbits warrants its further investigation. The two main components of such a system are a long insulated wire and the plasma generating hollow cathodes needed to maintain electrical contact with the ionosphere. Results of preliminary theoretical and experimental investigations of this system are presented. The theoretical work involved the equilibrium configurations of the wire and the nature of small oscillation about these equilibrium positions. A particularly interesting result was that two different configurations are allowed when the current is above a critical value. Experimental investigations were made of the optimal starting and running conditions for the proposed, low current hollow cathodes. Although optimal ranges of temperature, argon pressure and discharge voltage were identified, start up became progressively more difficult. This supposed depletion or contamination of the emissive surface could be countered by the addition of new emissive material.

Hite, Gerald E.↗

Carrier surface generation and recombination effects in photoconduction of HgI2 single crystals

Dc photoconductivity characteristics of HgI2 single crystals have been measured in the range of 1.75-2.75 eV, using CuI as a transparent electrical contact. Hole and electron photocurrents could be separately measured by applying different voltage polarities to the illuminated electrode. It is shown that charge carrier generation near the surface is highly extrinsic, as displayed by differences in the hole and electron photogeneration spectra. Analysis of the photoconductivity versus voltage characteristics indicates that the hole and electron bulk trapping times satisfy greater than 70 and 3 microsec, respectively. The hole and electron surface recombination velocities were 1.0 x 10 to the 4th cm/s and 8 x 10 to the 5th cm/s, respectively.

Burshtein, Z.↗

Inductively-Activated Short-Interval Timer

Timing circuit in pneumatically launched projectile triggers explosive charge in projectile at specified delay after launch. Both power and control signals coupled inductively to timer from stationary launcher circuitry. Eliminates need for direct electrical contacts, which are unreliable and generate sparks that trigger explosive accidentally. Inductive coupling also provides higher reliability in field operation than contacts. Concept useful in such other safety-related applications as remotely or automatically controlling flow of bottled flammable gas.

Wiker, Gordon A.↗

Surface Halogenation Of High-Temperature Superconductors

Surface halogenation experimental technique of postgrowth nonaqueous chemical processing of high-temperature superconductors. Research continues in use of technique to obtain superconducting and/or passivated surfaces, to etch bulk superconductors, and to make low-resistance electrical contacts. Most promising etchant is bromine dissolved in such polar nonaqueous solvents as alchols, acetone, or ether. Etchant appears to act only on surface without adversely affecting superconducting bulk of film.

Vasquez, Richard P.↗

Polymeric Electrolytic Hygrometer For Harsh Environments

Design of polymeric electrolytic hygrometer improved to meet need for reliable measurements of relative humidity in harsh environments of pulpmills and papermills. Redesigned sensor head features shorter, more-rigidly-held sensing element, less vulnerable than previous version to swell and loss of electrical contact. Useful for control of batch dryers in food and pharmaceutical industries.

Lawson, Daniel D.↗

Jig Aligns Shadow Mask On CCD

Alignment viewed through microscope. Alignment jig positions shadow mask on charge-coupled device (CCD) so metal film deposited on it precisely. Allows CCD package to be inserted and removed without disturbing alignment of mask. Holds CCD packages securely and isolates it electrostatically while providing electrical contact to each of its pins. When alignment jig assembled with CCD, used to move mask under micrometer control.

Matus, Carlos V.↗

Practical application of HgI2 detectors to a space-flight scanning electron microscope

Mercuric iodide X-ray detectors have been undergoing tests in a prototype scanning electron microscope system being developed for unmanned space flight. The detector program addresses the issues of geometric configuration in the SEM, compact packaging that includes separate thermoelectric coolers for the detector and FET, X-ray transparent hermetic encapsulation and electrical contacts, and a clean vacuum environment.

Bradley, J. G.↗

Phase equilibrium modeling for high temperature metallization on GaAs solar cells

Recent trends in performance specifications and functional requirements have brought about the need for high temperature metallization technology to be developed for survivable DOD space systems and to enhance solar cell reliability. The temperature constitution phase diagrams of selected binary and ternary systems were reviewed to determine the temperature and type of phase transformation present in the alloy systems. Of paramount interest are the liquid-solid and solid-solid transformations. Data are being utilized to aid in the selection of electrical contact materials to gallium arsenide solar cells. Published data on the phase diagrams for binary systems is readily available. However, information for ternary systems is limited. A computer model is being developed which will enable the phase equilibrium predictions for ternary systems where experimental data is lacking.

Chung, M. A.↗