Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTRIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Spatial electron density and electric field strength measurements in microwave cavity experiments

Measurements of electron density and electric field strength have been made in an argon plasma contained in a resonant microwave cavity at 2.45 GHz. Spatial measurements of electron density, n sub e, are correlated with fluorescence observations of the discharge. Measurements of n sub e were made with Stark broadening and compared with n sub 3 calculated from measured plasma conductivity. Additional measurements of n sub 3 as a function of pressure and in mixtures of argon and oxygen are presented for pressures from 10 Torr to 1 atm. Measurements in flowing gases and in static systems are presented. In addition, limitations of these measurements are identified.

Peters, M.↗

Spatial electron density and electric field strength measurements in microwave cavity experiments

Measurements of electron density and electric field strength have been made in an argon plasma contained in a resonant microwave cavity at 2.45 GHz. Spatial measurements of electron density, n sub e, are correlated with fluorescence observations of the discharge. Measurements of n sub e were made with Stark broadening and compared with n sub e calculated from measured plasma conductivity. Additional measurements of n sub e as a function of pressure and in mixtures of argon and oxygen are presented for pressures from 10 Torr to 1 atm. Measurements in flowing gases and in static systems are presented. In addition, limitations of these measurements are identified.

Peters, M.↗

Nondestructive measurement of capillary tube internal diameter

Technique provides nondestructive method of making quick, accurate determination by measuring electrical resistance of capillary tube when it is filled with electrolyte of known conductivity. Apparatus consists of conductivity cell and equipment for measuring resistance and for monitoring and controlling temperature.

Ho, W. W.↗

Calorimetric output power measurements on a CW 20 kW 7.16 GHz microwave transmitter

A calorimetric measurement technique developed for NASA's Deep Space Network (DSN) transmitters that does not require data on the coolant's thermal parameters is described. Calibration of the measurement system is achieved by measuring the DC input power to the klystron and relating coolant temperature increases to this known power dissipation. Agreement between calorimetric and electrical measurements of total system power was good, the difference being less than 2 percent. The operation of the system was not greatly affected by the composition of the coolant, which was varied from pure water to 40 percent ethylene glycol by mass. Good accuracy was also shown at output power levels, which varied over a 3.6:1 range.

Perez, Raul M.↗

Development and life-testing of 10 kW class thermal arcjet engines

A facility to develop and test thermal arcjet engines over extended periods of time has been constructed and is described in this paper. It consists of a large vacuum tank, high capacity vacuum pumps, a 100 kW power supply and a large ammonia propellant storage and delivery system. The facility is instrumented to measure electrical power dissipated in the engine, propellant mass flow rate and developed thrust. Pressures and temperatures up to 2400 K can also be measured. The entire facility is computer-controlled and can be operated unattended for many weeks. Two 30 kW thermal arcjet engines that have been designed, built and are being tested in this facility are also described.

Pivirotto, T. J.↗

Sensor arrays for detecting analytes in fluids

A sensor array for detecting an analyte in a fluid, comprising at least first and second chemically sensitive resistors electrically connected to an electrical measuring apparatus, wherein each of the chemically sensitive resistors comprises a mixture of nonconductive material and a conductive material. Each resistor provides an electrical path through the mixture of nonconductive material and the conductive material. The resistors also provide a difference in resistance between the conductive elements when contacted with a fluid comprising an analyte at a first concentration, than when contacted with an analyte at a second different concentration. A broad range of analytes can be detected using the sensors of the present invention. Examples of such analytes include, but are not limited to, alkanes, alkenes, alkynes, dienes, alicyclic hydrocarbons, arenes, alcohols, ethers, ketones, aldehydes, carbonyls, carbanions, polynuclear aromatics, organic derivatives, biomolecules, sugars, isoprenes, isoprenoids and fatty acids. Moreover, applications for the sensors of the present invention include, but are not limited to, environmental toxicology, remediation, biomedicine, material quality control, food monitoring and agricultural monitoring.

Lewis, Nathan S.↗

Metabolic analyzer

An apparatus is described for the measurement of metabolic rate and breathing dynamics in which inhaled and exhaled breath are sensed by sealed, piston-displacement type spirometers. These spirometers electrically measure the volume of inhaled and exhaled breath. A mass spectrometer analyzes simultaneously for oxygen, carbon dioxide, nitrogen, and water vapor. Circuits responsive to the outputs of the spirometers, mass spectrometer, temperature, pressure, and timing signals compute oxygen consumption, carbon dioxide production, minute volume, and respiratory exchange ratio. A selective indicator provides for readout of these data at predetermined cyclic intervals.

Perry, C. L.↗

Metabolic analyzer

An apparatus is described for the measurement of metabolic rate and breathing dynamics in which inhaled and exhaled breath are sensed by sealed, piston-displacement type spirometers. These spirometers electrically measure the volume of inhaled and exhaled breath. A mass spectrometer analyzes simultaneously for oxygen, carbon dioxide, nitrogen and water vapor. Computation circuits are responsive to the outputs of the spirometers, mass spectrometer, temperature, pressure and timing signals and compute oxygen consumption, carbon dioxide production, minute volume and respiratory exchange ratio. A selective indicator provides for read-out of these data at predetermined cyclic intervals.

Rummel, J. A.↗

A Limited In-Flight Evaluation of the Constant Current Loop Strain Measurement Method

For many years, the Wheatstone bridge has been used successfully to measure electrical resistance and changes in that resistance. However, the inherent problem of varying lead wire resistance can cause errors when the Wheatstone bridge is used to measure strain in a flight environment. The constant current loop signal-conditioning card was developed to overcome that difficulty. This paper describes a limited evaluation of the constant current loop strain measurement method as used in the F-16XL ship 2 Supersonic Laminar Flow Control flight project. Several identical strain gages were installed in close proximity on a shock fence which was mounted under the left wing of the F- 1 6XL ship 2. Two strain gage bridges were configured using the constant current loop, and two were configured using the Wheatstone bridge circuitry. Flight data comparing the output from the constant current loop configured gages to that of the Wheatstone bridges with respect to signal output, error, and noise are given. Results indicate that the constant current loop strain measurement method enables an increased output, unaffected by lead wire resistance variations, to be obtained from strain gages.

Olney, Candida D.↗

XPS study of the Al/SiO2 interface viewed from the SiO2 side

The first nondestructive measurement of the chemical and physical characteristics of the interface between bulk SiO2 and thick aluminum films is presented. Both X-ray photoelectron spectroscopy (XPS) and electrical measurements of unannealed resistively evaporated Al films on thermal SiO2 indicate an atomically abrupt interface. Postmetallization annealing (PMA) at 450 C induces reduction of the SiO2 by the aluminum, resulting in the layer ordering SiO2/Al2O3/Si/Al. The XPS measurement is performed from the SiO2 side after removal of the Si substrate after etching with XeF2 gas and thinning of the SiO2 layer with HF:ETOH. This represents a powerful new approach to the study of metal-insulator and other interfaces.

Hecht, M. H.↗

A novel X-ray photoelectron spectroscopy study of the Al/SiO2 interface

The nondestructive measurement of the chemical and physical characteristics of the interface between bulk SiO2 and thick aluminum films is reported. Both X-ray phototelectron spectroscopy (XPS) and electrical measurements of unannealed, resistively evaporated Al films on thermal SiO2 indicate an atomically abrupt interface. Post metallization annealing at 450 C induces reduction of the SiO2 by the aluminum, at a rate consistent with the bulk reaction rate. The XPS measurement is performed from the SiO2 side after the removal of the Si substrate with XeF2 gas and thinning of the SiO2 layer with HF:ETOH. This represents a powerful new approach to the study of metal-insulator and related interfaces.

Hecht, M. H.↗

Thermal Fluctuation Noise in Mo/Au Superconducting Transition-Edge Sensor Microcalorimeters

In many superconducting transition-edge sensor (TES) microcalorimeters, the measured electrical noise exceeds theoretical estimates based on a thermal model of a single body thermally connected to a heat bath. Here, we report on noise and complex impedance measurements of a range of designs of TESs made with a Mo/Au bilayer. We have fitted the measured data using a two-body model, where the x-ray absorber and the TES are connected by an internal thermal conductance Gae. We find that the so-called excess noise measured in these devices is consistent with the noise generated from the internal thermal fluctuations between the x-ray absorber and the TES. Our fitted parameters are consistent with the origin of Gae being from the finite thermal conductance of the TES itself. These results suggest that even in these relatively low resistance Mo/Au TESs, the internal thermal conductance of the TES may add significant additional noise and could account for all the measured excess noise. Furthermore, we find that around regions of the superconducting transition with rapidly changing derivative of resistance with respect to temperature, an additional noise mechanism may dominate. These observations may lead to a greater understanding of TES devices and allow the design of TES microcalorimeters with improved performance.

Wakeham, N. A.↗

The properties of polycrystalline silicon solar cells with controlled titanium additions

By coupling the results of electrical measurements, such as spectral response, lighted and dark I-V determinations, and deep-level-transient spectroscopy with optical and laser scan photomicroscopy, the effects of grain boundaries and impurities on silicon solar cells were evaluated. Titanium, which produces two deep levels in silicon, degrades cell performance by reducing bulk lifetime and thus cell short-circuit current. Electrically active grain boundaries induce carrier recombination in the bulk and depletion regions of the solar cell. Experimental data imply a small but measurable segregation of titanium into some grain boundaries of the polycrystalline silicon containing high Ti concentration. However, for the titanium-contaminated polycrystalline material used in this study, solar cell performance is dominated by the electrically active titanium concentration in the grains. Microstructural impacts on the devices are of secondary importance

Rohatgi, A.↗

Sensor arrays for detecting microorganisms

A sensor array for detecting a microorganism comprising first and second sensors electrically connected to an electrical measuring apparatus, wherein the sensors comprise a region of nonconducting organic material and a region of conducting material compositionally that is different than the nonconducting organic material and an electrical path through the regions of nonconducting organic material and the conducting material. A system for identifying microorganisms using the sensor array, a computer and a pattern recognition algorithm, such as a neural net are also disclosed.

Lewis, Nathan S.↗

Vertical neutral wind in the equatorial F-region deduced from electric field and ion density measurements

Direct current (DC) electric field and ion density measurements near density depletion regions (that is, equatorial plasma bubbles) are used to estimate the vertical neutral wind speed. The measured zonal electric field in a series of density depletions crossed by the San Marco D satellite at 01.47-01.52 Universal Time (UT) on 25 October 1988, can be explained if a downward neutral wind of 15-30 m/s exists. Simultaneously, the F-region plasma was moving downward at a speed of 30-50 m/s. These events appear in the local time sector of 23.00-23.15 in which strong downward neutral winds may occur. Indeed, airglow measurements suggest that downward neutral velocities of 25-50 m/s are possible at time near midnight in the equatorial F-region.

Laakso, Harri↗

Investigation of reliability attributes and accelerated stress factors on terrestrial solar cells

Major effort during this reporting period was devoted to two tasks: improvement of the electrical measurement instrumentation through the design and construction of a microcomputer controlled short interval tester, and better understanding of second quadrant behavior by developing a mathematical model relating cell temperature to electrical characteristics. In addition, some preliminary work is reported on an investigation into color changes observed after stressing.

Lathrop, J. W.↗