Liquid hydrogen tankage design

For this, the tankage experienced only minor thermal loadings and flight loads, hence, the predominate loading was the tank pressurization. Since the tanks were basically tension designed, the fatigue and damage tolerance criteria played the most important part in the overall design of the tank. Sensitivity factors were generated for the reference LH2-fueled airplane to provide a basis for evaluation of the effects of changes from the baseline design. For example, the various candidate insulation systems and tank structural concepts offer tradeoffs of the tankage offset distance (distance between exterior surface to tank) and weight. As the offset varies, the aircraft fuselage length must change to provide the required fuel volume within the fixed fuselage cross-section and hence the sensitivity on the aircraft DOC could be assessed.

Davis, G. W.↗

Monitoring of Double-Stud Wall Moisture Conditions in the Northeast

BSC TO5 Task 2.2 Monitoring of Double Stud Wall Moisture Conditions in the Northeast Field test data available for wood moisture contents, temperature, and relative humidity. STRUCTURE - House - Devens, MA 01432 Three double-stud assemblies were compared: 12-in. ocSPF, 12-in. cellulose, and 5.5-in. ocSPF at the exterior of a double-stud wall (to approximate conventional 2 x 6 wall construction and insulation levels, acting as a control wall). These assemblies were repeated on the north and south orientations, for a total of six assemblies. Data were collected from December 2011 through July 2014, capturing three winters of operation in various states. Winter 2011-2012 was very mild (warm) and the house had very low interior relative humidity (RH) because it was unoccupied. Winter 2012-2013 was colder and the house had very high (40%-50%) interior RH until the ventilation system was put into operation (mid-February 2013). Winter 2013-2014 was very cold, but the ventilation system was operated, resulting in moderate interior RHs. Under "normal" interior conditions (functioning ventilation system, wintertime RH 10%-30%), ocSPF walls (both 12 in. and 5.5 in.) with latex paint as interior vapor control (nominally Class III, but possibly more vapor open) showed low risk; all sheathing moisture contents (MCs) remained lower than 20%. However, the 12-in. cellulose wall had MCs higher than 20% on the north side. In addition, the cellulose wall sheathing-insulation interface had high RH conditions. Under high interior humidity loading (nonfunctional ventilation system, 40%-50% interior RH), all test walls showed MCs and sheathing-insulation interface RHs well into the high risk range. The cellulose walls showed particularly high MCs (sheathing in excess of 30%), while the ocSPF walls showed MCs in the 18%-25% range. In addition, the monitoring showed evidence of liquid water condensation (which can result in quick degradation) in all walls; the condensation was substantial in the cellulose walls. These condensation issues occurred on the north and south sides. But in all walls, during each summer after a winter of wetting, moisture levels fell well into the safe range. Based on the difference between the winters, it is clear that interior RH can have a tremendous effect on the performance of enclosure systems, in terms of interstitial condensation risks, when using more vapor-open interior finishes such as latex paint. The ocSPF walls showed consistently lower MCs and interface RH levels than the cellulose walls. Although air leakage cannot be eliminated as a possibility, it is likely that at the thicknesses applied, the ocSPF provided reasonable vapor control (1.5-3.5 perms when combined with Class III latex paint) under normal loading conditions. The collected data were analyzed in terms of ASHRAE Standard 160 criteria (tabulating hours with RH and temperatures that support mold growth), using the calculated surface RH at the sheathing-insulation interface. All north-facing walls failed through all three winters; in particular, there were large numbers of failure hours during the high humidity winter (2012-2013). Sheathing-insulation interface temperatures and RHs during the high humidity winter showed many hours with mold risk conditions (high humidity and sufficient temperature for mold growth).

Array↗

A computational analysis of effective R-values of buried ducts – the dynamic performance of buried ducts

Here, this paper evaluates the thermal performance of ducts partially or fully buried in loose-fill attic insulation. The overall thermal resistance between the ducts and the attic is referred to as an effective R-value. This paper shows a strong dependency of assumed attic temperature on the effective R-value. Based on the results, the effective R-value can be about twice as much with an attic temperature of 130 °F [54.4 °C], compared to when the attic temperature is 80 °F [26.7 °C]. Thus, this paper provides a polynomial regression equation based on a large set of simulations to determine the effective R-value of buried ducts depending on attic temperature and whether the HVAC system runs in cooling or heating mode. Further, the work presented in this paper investigated the potential impact of convective airflow within the attic insulation, particularly around the ducts. The analysis was based on computational fluid dynamics (CFD) and indicated that convectional forces are presented around the exterior surface of the ducts, but with negligible impact on the overall heat balance between the duct and the attic space.

97 MATHEMATICS AND COMPUTING↗

Home Insulation With the Stroke of a Brush

Hy-Tech Thermal Solutions, LLC, of Melbourne, Florida, is producing a very complex blend of ceramic vacuum-filled refractory products designed to minimize the path of hot air transfer through ceilings, walls, and roofs. The insulating ceramic technology blocks the transfer of heat outward when applied to paint on interior walls and ceilings, and prevents the transfer of heat inward when used to paint exterior walls and roofs, effectively providing year-round comfort in the home. As a manufacturer and marketer of thermal solutions for residential, commercial, and industrial applications, Hy-Tech Thermal Solutions attributes its success to the high performance insulating ceramic microsphere originally developed from NASA thermal research at Ames Research Center. Shaped like a hollow ball so small that it looks as if it is a single grain of flour to the naked eye (slightly thicker than a human hair), the microsphere is noncombustible and fairly chemical-resistant, and has a wall thickness about 1/10 of the sphere diameter, a compressive strength of about 4,000 pounds per square inch, and a softening point of about 1,800 C. Hy-Tech Thermal Solutions improved upon these properties by removing all of the gas inside and creating a vacuum. In effect, a 'mini thermos bottle' is produced, acting as a barrier to heat by reflecting it away from the protected surface. When these microspheres are combined with other materials, they enhance the thermal resistance of those materials. In bulk, the tiny ceramic 'beads' have the appearance of a fine talcum powder. Their inert, nontoxic properties allow them to mix easily into any type of paint, coating, adhesive, masonry, or drywall finish. Additionally, their roundness causes them to behave like ball bearings, rolling upon each other, and letting the coatings flow smoothly. When applied like paint to a wall or roof, the microsphere coating shrinks down tight and creates a dense film of the vacuum cells. The resulting ceramic layer improves fire resistance, protects from ultraviolet rays, repels insects such as termites, and shields from the destructive forces of nature.

Source record↗

Jackson Park Hospital Green Building Medical Center

Jackson Park Hospital completed the construction of a new Medical Office Building on its campus this spring. The new building construction has adopted the City of Chicago's recent focus on protecting the environment, and conserving energy and resources, with the introduction of green building codes. Located in a poor, inner city neighborhood on the South side of Chicago, Jackson Park Hospital has chosen green building strategies to help make the area a better place to live and work. The new green building houses the hospital's Family Medicine Residency Program and Specialty Medical Offices. The residency program has been vital in attracting new, young physicians to this medically underserved area. The new outpatient center will also help to allure needed medical providers to the community. The facility also has areas designated to women's health and community education. The Community Education Conference Room will provide learning opportunities to area residents. Emphasis will be placed on conserving resources and protecting our environment, as well as providing information on healthcare access and preventive medicine. The new Medical Office Building was constructed with numerous energy saving features. The exterior cladding of the building is an innovative, locally-manufactured precast concrete panel system with integral insulation that achieves an R-value in excess of building code requirements. The roof is a 'green roof' covered by native plantings, lessening the impact solar heat gain on the building, and reducing air conditioning requirements. The windows are low-E, tinted, and insulated to reduce cooling requirements in summer and heating requirements in winter. The main entrance has an air lock to prevent unconditioned air from entering the building and impacting interior air temperatures. Since much of the traffic in and out of the office building comes from the adjacent Jackson Park Hospital, a pedestrian bridge connects the two buildings, further decreasing the amount of unconditioned air that enters the office building. The HVAC system has an Energy Efficiency Rating 29% greater than required. No CFC based refrigerants were used in the HVAC system, thus reducing the emission of compounds that contribute to ozone depletion and global warming. In addition, interior light fixtures employ the latest energy-efficient lamp and ballast technology. Interior lighting throughout the building is operated by sensors that will automatically turn off lights inside a room when the room is unoccupied. The electrical traction elevators use less energy than typical elevators, and they are made of 95% recycled material. Further, locally manufactured products were used throughout, minimizing the amount of energy required to construct this building. The primary objective was to construct a 30,000 square foot medical office building on the Jackson Park Hospital campus that would comply with newly adopted City of Chicago green building codes focusing on protecting the environment and conserving energy and resources. The energy saving systems demonstrate a state of the-art whole-building approach to energy efficient design and construction. The energy efficiency and green aspects of the building contribute to the community by emphasizing the environmental and economic benefits of conserving resources. The building highlights the integration of Chicago's new green building codes into a poor, inner city neighborhood project and it is designed to attract medical providers and physicians to a medically underserved area.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal Performance of Uninsulated and Partially Filled Wall Cavities: Preprint

Low-rise, wood-framed homes are the most common type of residential structures in the United States. Wood wall construction supports roofs efficiently and provides a stable frame for attaching interior and exterior wall coverings. Wall cavities are prevalent and increase thermal resistance, particularly when they are filled with insulating material. This paper describes detailed computational fluid dynamics modeling to evaluate the thermal performance of uninsulated or partially filled wall cavities and accounts for conduction through framing, convection, and radiation. Parameters are ambient outdoor temperature, cavity surface emissivity, cavity aspect ratio, and insulation height. Understanding the thermal performance of uninsulated or partially insulated wall cavities is essential for conserving energy in residential buildings. The results can serve as input for building energy simulation tools such as DOE2 and EnergyPlus for modeling the temperature dependent energy performance of new and older homes with uninsulated or partially insulated walls.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Hollow cathodes for arcjet thrusters

In an attempt to prevent exterior spot emission, hollow cathode bodies and orifice plates were constructed from boron nitride which is an electrical insulator, but the orifice plates melted and/or eroded at high interelectrode pressures. The most suitable hollow cathodes tested included a refractory metal orifice plate in a boron nitride body, with the insert insulated electrically from the orifice plate. In addition, the hollow cathode interior was evacuated to assure a low pressure at the insert surface, thus promoting diffuse electron emission. At high interelectrode pressures, the electrons tended to flow through the orifice plate rather than through the orifice, which could result in overheating of the orifice plate. Using a carefully aligned centerline anode, electron flow through the orifice could be sustained at interelectrode pressures up to 500 torr - but the current flow path still occasionally jumped from the orifice to the orifice plate. Based on these tests, it appears that a hollow cathode would operate most effectively at pressures in the arcjet regime with a refractory, chemically stable, and electrically insulating cathode body and orifice plate.

Luebben, Craig R.↗

The Shuttle tile story

The structural problems associated with the reusable thermal protection system (TPS) of the Space Shuttle Orbiter are assessed. The ceramic insulation was placed on the aluminum in the form of about 30,000 tiles over approximately 70% of the Orbiter's exterior. The tiles were bonded to felt pads, and then the tile-pad structure was attached to the aluminum skin. As Orbiter design progressed, it was discovered that the TPS would have to withstand loads greater than initially predicted. The group tensile strength was less than that of the individual components. This was the primary factor contributing to the delay of the first flight. Values are given for Orbiter isotherms during a normal flight as well as the corresponding TPS distribution. The complete TPS assemblage is shown schematically, noting the sequence of assembling the tile components into a testing specimen. It is noted that tensile loads are applied to the strain-isolation path at discrete regions along transverse fiber bundles, causing a 50% reduction in system tensile strength. Procedures for strengthening the interface between the insulation and strain-isolation path are discussed and flight-simulation tests are outlined.

Cooper, P. A.↗

Hypervelocity Impact Test Results for a Metallic Thermal Protection System

Hypervelocity impact tests have been performed on specimens representing metallic thermal protection systems (TPS) developed at NASA Langley Research Center for use on next-generation reusable launch vehicles (RLV). The majority of the specimens tested consists of a foil gauge exterior honeycomb panel, composed of either Inconel 617 or Ti-6Al-4V, backed with 2.0 in. of fibrous insulation and a final Ti-6Al-4V foil layer. Other tested specimens include titanium multi-wall sandwich coupons as well as TPS using a second honeycomb sandwich in place of the foil backing. Hypervelocity impact tests were performed at the NASA Marshall Space Flight Center Orbital Debris Simulation Facility. An improved test fixture was designed and fabricated to hold specimens firmly in place during impact. Projectile diameter, honeycomb sandwich material, honeycomb sandwich facesheet thickness, and honeycomb core cell size were examined to determine the influence of TPS configuration on the level of protection provided to the substructure (crew, cabin, fuel tank, etc.) against micrometeoroid or orbit debris impacts. Pictures and descriptions of the damage to each specimen are included.

Karr, Katherine L.↗

Mitigating Moisture with High-R Walls

Energy-efficient building enclosures are key to decreasing energy load demand and enabling advanced space-conditioning systems for high-performance homes. One efficient enclosure design solution is high-R walls, which feature increased insulation levels as an effective solution for reducing air leakage and permeance of material layers. To increase builder confidence and encourage greater market adoption of high-R walls, Home Innovation Research Labs sought to demonstrate the long-term moisture performance of several high-R wall configurations in cold climate zones. The team monitored 22 newly constructed, occupied homes located throughout climate zones 4–7, where a substantial vapor drive to the exterior is present during the winter.

buildings↗

Energy Efficient Electrochromic Windows Incorporating Ionic Liquids

One approach to increasing the energy efficiency of windows is to control the amount of solar radiation transmitted through a window by using electrochromic technology. What is unique about this project is that the electrochromic is based on the reduction/oxidation reactions of cathodic and anodic organic semi-conducting polymers using room temperature ionic liquids as ion transport electrolytes. It is believed that these types of coatings would be a lower cost alternative to traditional all inorganic thin film based electrochromic technologies. Although there are patents1 based on the proposed technology, it has never been reduced to practice and thoroughly evaluated (i.e. durability and performance) in a window application. We demonstrate that by using organic semi-conductive polymers, specific bands of the solar spectrum (specifically visible and near infrared) can be targeted for electrochemical variable transmittance responsiveness. In addition, when the technology is incorporated into an insulating glass unit, the energy parameters such as the solar heat gain coefficient and the light to solar gain ratio are improved over that of a typical insulating glass unit comprised of glass with a low emissivity coating. A minimum of {approx}0.02 quads of energy savings per year with a reduction of carbon emissions for electricity of {approx}320 MKg/yr benefit is achieved over that of a typical insulating glass unit including a double silver low-E coating. Note that these values include a penalty in the heating season. If this penalty is removed (i.e. in southern climates or commercial structures where cooling is predominate year-round) a maximum energy savings of {approx}0.05 quad per year and {approx}801 MKg/yr can be achieved over that of a typical insulating glass unit including a double silver low-E coating. In its current state, the technology is not durable enough for an exterior window application. The primary downfall is that the redox chemistry fails to recover to a bleached state upon exposure to heat and solar radiation while being cycled over time from the bleached to the dark state. Most likely the polymers are undergoing degradation reactions which are accelerated by heat and solar exposure while in either the reduced or oxidized states and the performance of the polymers is greatly reduced over time. For this technology to succeed in an exterior window application, there needs to be more work done to understand the degradation of the polymers under real-life application conditions such as elevated temperatures and solar exposure so that recommendations for improvements in to the overall system can be made. This will be the key to utilizing this type of technology in any future real-life applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hermetically sealed porous-wall hollow microspheres enabled by monolithic glass coatings: Potential for thermal insulation applications

Thermal insulation materials are crucial to improve the energy performance of buildings and industrial applications. We report an approach to create hermetically vacuum-sealed silica-based hollow microspheres that can lower the thermal conductivity of closed-cell insulation materials. The wall structure of these hollow microspheres includes a reticulated network of pores or channels that extend through the thickness of the wall. When a thin layer of glass material is applied to the wall exterior, followed by a vacuum-assisted thermal treatment process, the coated microsphere surfaces display a highly dense conformal coverage and near-complete elimination of surface porosity. The sealing efficiency of these microspheres is verified by trapping argon within their cavities as well as through evacuating their hollow cores. Notably, incorporating the evacuated microspheres into a polymer matrix resulted in ~27% enhancement in its thermal insulation performance and no notable loss of performance was observed following three months of exposure to ambient conditions. Thus, we believe that the present study offers a commercially viable strategy that opens the door to applications of such inorganic hollow particles in areas ranging from vacuum-based thermal insulation systems to catalysis, separation technologies, and medical fields.

36 MATERIALS SCIENCE↗

Validation Study of Experimental Insulating and Air-Sealing Technology for Enclosed Roof Cavities

Validation Study of Experimental Insulating and Air-Sealing Technology for Enclosed Roof Cavities, explores a new minimally invasive system known as Pinhole Insulation ® for retroft insulation of cathedral ceilings, flat roofs, dormer roofs, and other enclosed roof cavities. It also explores the validation of the associated equipment, software, and materials used in this application. The Pinhole Insulation process essentially consists of drilling a ¼” hole in the ceiling surface and then injecting closed cell polyurethane foam such that the foam is deposited on the interior surface of the exterior roof sheathing. In a typical cathedral ceiling with R19 batts, the R value will be improved by at least 60% and the cavity will become completely air sealed. The system is quick, minimally invasive and at least an order of magnitude less expensive than alternatives such as removing the ceiling surface and spraying closed cell foam.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating Ventilation Systems for Existing Homes

During the course of this project, an affordable and high performance ductwork system to directly address the problems of thermal losses, poor efficiency, and air leakage was designed. To save space and enable direct connections between different floors of the building, the ductwork system was designed in such a way that it occupied interior or exterior frame wall cavities. The ductwork system satisfied building regulations for structural support when bridging multiple floors, the spread of fire and smoke, and insulation to reduce the heat flow into or out of the building. Retrofits of urban residential buildings will be the main focus for the application of this ductwork system. Highly reflective foils and insulating materials were used to aid in the increase of the overall R-value of the ductwork itself and the wall assembly. It is expected that the proposed system will increase the efficiency of the HVAC system and the thermal resistance of the building envelope. The performance of the proposed ductwork design was numerically evaluated in a number of different ways. Our results indicate that the duct method is a very cost attractive alternative to the conventional method.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Empower Wall: Active insulation system leveraging additive manufacturing and model predictive control

Buildings are one of the largest energy consumers worldwide, using large amounts of energy during their construction and for climate control during operation. Active insulation systems (AIS) have been shown to reduce the energy needed for climate control in buildings by dynamically regulating the heat transferred between a building’s interior and exterior. Infrastructure-scale additive manufacturing (AM) has the potential to reduce the resources needed for building construction. Combining these two technologies into a single building envelope would create a path towards more sustainable buildings. A test was conducted for the Federal Energy Management Program (FEMP) Energy Exchange training and trade show, in August 2021, to investigate a new building envelope design, termed the Empower Wall, that utilized an AIS and was constructed using AM. Model predictive control was implemented to manage operation of the Empower Wall in concert with the existing HVAC system. Finally, the prototype system demonstrated that the Empower Wall lowered total energy consumption and reduced the cost of energy used.

36 MATERIALS SCIENCE↗

Integrated-magnetic apparatus

Disclosure is made of an integrated-magnetic apparatus, comprising: winding structure for insulatingly carrying at least two generally flat, laterally offset and spaced apart electrical windings of a power converter around an aperture; a core having a flat exterior face, an interior cavity and an un-gapped core-column that is located within the cavity and that passes through the aperture of the winding structure; flat-sided surface carried by the core and forming an interior chamber that is located adjacent to the flat face of the core and forming a core-column that has a gap and that is located within the chamber; and structure, located around the gapped core-column, for carrying a third electrical winding of the power converter. The first two electrical windings are substantially located within the cavity and are adapted to be transformingly coupled together through the core. The third electrical winding is adapted to be inductively coupled through the gapped core-column to the other electrical windings, and is phased to have the magnetic flux passing through the gapped core-column substantially in the same direction as the magnetic flux passing through the un-gapped core-column and to have substantially the same AC components of flux in the gapped core-column and in the un-gapped core-column.

Bloom, Gordon E.↗

A non-volatile thermal switch for building energy savings

Compared with traditional static insulation, a thermally switchable building envelope could reduce annual heating and cooling loads by intermittently coupling to the outside environment when beneficial. Here, we demonstrate a voltage-actuated, contact/non-contact thermal switch that meets the unique challenges of this application. The switch is non-volatile, consuming electricity only briefly while switching and none to hold steady state. The switch ratio is 12, the off state has a low effective thermal conductivity of 0.045 W m -1 K -1 , comparable to fiberglass insulation, and the performance is stable over 1,000 switching cycles. Numerical simulations using real-world climate data show that combining this thermal switch with a thermal storage layer in a building envelope can yield annual energy savings of 9%-55% (heating) and 17%-76% (air conditioning), depending on the climate zone. The greatest benefits are realized when the exterior temperature crosses well above and below the desired interior temperature within a single 24 h period.