Emission of high-energy electrons during alloy- evaporation processes on hot metal filaments.
High energy electrons emission during alloy evaporation on hot metal filaments used for thin film deposition
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
High energy electrons emission during alloy evaporation on hot metal filaments used for thin film deposition
Plasma probe surveys were conducted in a 30-cm source to verify that the uniformity in the ion beam is the result of a corresponding uniformity in the discharge-chamber plasma. A 15 cm permanent magnet multipole ion source was designed, fabricated, and demonstrated. Procedures were investigated for texturing a variety of seed and surface materials for controlling secondary electron emission, increasing electron absorption of light, and improved attachment of biological tissue for medical implants using argon and tetrafluoromethane as the working gases. The cross section for argon-argon elastic collisions in the ion-beam energy range was calculated from interaction potentials and permits calculation of beam interaction effects that can determine system pumping requirements. The data also indicate that different optimizations of ion-beam machines will be advantageous for long and short runs, with 1 mA-hr/cm being the rough dividing line for run length. The capacity to simultaneously optimize components in an ion-beam machine for a single application, a capacity that is not evident in competitive approaches such as diode sputtering is emphasized.
The subject of surface potentials on natural and artificial bodies in space is reviewed with particular emphasis on recent developments. Following a brief survey of work done up to the early 1970s on the charging of astrophysical objects in interstellar and interplanetary space and spacecraft charging, the various charging mechanisms in space are examined, including the collection of plasma particles, photoemission, and secondary electron emission by electron impact and ion impact, and the effects on charging of nonisotropic plasmas, wakes, and environmental magnetic and electric fields are considered. The concept of equilibrium potential is discussed, along with differential charging, potential barriers and discharge processes. The measurement of spacecraft potentials is then considered, and recent work on spacecraft potential modification and control by active and passive means is presented. Finally, astrophysical applications where charging effects may be important are discussed, and areas for further work are indicated.
Using the potentials measured by the Spacelab's Charge and Current Probe during beam ejections and the signature of the harmonic emissions generated by pulsed electron beams, Neubert et al. (1988) presented evidence that overdense electron beams (with electron density above 150,000/cu cm) can escape the near vicinity of the Shuttle. This paper supplements these results by presenting a further indication of the beam escape and propagation out to at least 200 m, using the whistler-mode wave signature obtained during the SL-12 electron beam ejection which occurred on DOY 213 of 1985 from 03:30 to 03:37 UT. The combined results support the hypothesis that overdense electron beams can and will escape from a spacecraft, contrary to predictions based upon idealized simulations of the injection process.
A synthetic electron cyclotron emission (ECE) diagnostic is used to interpret ECE signals from preset plasma equilibrium profiles, including magnetic field, electron density, and electron temperature. According to the simulation results, the electron temperature (T e ) profile covering the harmonic overlap region can be obtained by receiving ECE signals at the high field side (HFS) of the HL-2M plasma. The third harmonic ECE at the low field side (LFS) cannot pass through the second harmonic resonance layer at the HFS unless the optical thickness (τ) of the second harmonic becomes gray (τ ≤ 2). In addition, the impact of the relativistic frequency down-shift has been evaluated and corrected. The measurable range of the HFS ECE has been calculated by scanning different parameters (electron density, temperature, and magnetic field). Higher plasma parameters allow a wider radial range of electron temperature measurements. The minimum inner measurable position can reach R = 120 cm (r/a = -0.89) when the product of core temperature (T e0 ) and density (n e0 ) is greater than 35 × 10 19 keV m -3 , which is extended by more than 30 cm inward compared with that of the LFS measurement. The HFS ECE will greatly improve the diagnostic ability of ECE systems on the HL-2M tokamak.
Time projection chambers are useful for high energy particle physics, nuclear physics, and astronomy. To enhance the particle detection efficiency and performance of the projection chambers functional bilayer thin film coatings based on the atomic layer deposition method are utilized. Coating material selection is based on Auger neutralization process ion induced electron emission from metallic surfaces (e.g., Mo or W) combined with a high secondary electron emission coefficient. Application of high secondary electron emission materials (e.g., MgO and CaF2) enhances the multiplication of these emitted electrons from ion induction processes. Therefore, using suitable bilayer coatings the overall TPC signal detection efficiency can be increased.
The research for the development of new types of detectors for analysis of planetary atmospheres is summarized. Topics discussed include: corona discharge humidity detector, surface catalysis and exo-electron emission, and analysis of soil samples by means of exo-electron emission. A report on the exo-electron emission during heterogeneous catalysis is included.
The optics system of the Electron Cyclotron Emission Imaging (ECEI) diagnostics on the DIII-D tokamak has been developed and installed for high-resolution temperature fluctuations measurement in the previous decade. The System-on-Chip approach upgrade was finished in June 2019 with high integrated receiver array with 20 individual modules. In this paper, we design new optics with high-level integration. In the new optics system, there will be two mirrors from plasma to receiver array, including one replaceable curved mirror out of the vacuum and one fixed curved mirror in the vessel. There are two options with 1:1 and 1:2 magnifications for high poloidal resolution and larger poloidal window modes. Overall, the new optics system has multiple improvements, including lighter weight, smaller size, more flexible installation and alignment. The synthetic ECEI module is used to evaluate the new optics system.
This project worked on development of a transformative heat-to-electricity conversion device based on thermionic energy conversion. The research provided a unique opportunity to transform the thermionics technology of the 1950-1990s by applying modern materials and 21st century wafer-scale fabrication methods. Research was conducted to further development of a thermionic energy converter based on modern microfabrication and new low work function anode materials that can surpass all other forms of direct heat-to-electricity conversion. This project completed the following goals: (1) Developed components for use in thermionic energy converters and electron emission devices, including electrode materials for electron emission and electron absorption with ultimate work functions below 5 eV; (2) Designed and fabricated thermionic devices for energy conversion and electron emission based on the components developed in (1); (3) Engineered test systems to characterize electronic, thermal, and mechanical properties of thermionic devices and electron emitters and their components, and test devices and components designed and fabricated in (1) and (2); and (4) Developed theoretical modeling capabilities in support of these technical objectives.
High energy electrons and emission of galactic, omnidirectional synchrotron radiation in radio frequency and X rays regions
This report compares the coded aperture imaging performance of thermionic filament and carbon nanotube (CNT) field emitter-based electron sources in cycloidal-coded aperture mass spectrometers. The use of spatially coded apertures in mass spectrometry enables miniaturization by improving throughput without sacrificing resolution. CNT-based electron ionization sources for mass spectrometers provide several potential benefits over conventional thermionic emitters, including low voltage and low power consumption, room temperature operation, long lifetime, and ability to emit electrons in a pulsed mode. However, spatiotemporal variation in electron emission from CNTs is a major disadvantage. In this study, electron emission stability and spatiotemporal stability of the coded aperture image were compared for coded aperture cycloidal mass analyzers with either a CNT-based ion source or a thermionic filament-based ion source. We found that the thermionic filament-based ion source produced a significantly more stable coded aperture image than the CNT based ion source. The aperture image fluctuations in the CNT-based source are likely a result of adsorption and desorption of molecules on the CNT surface that cause local work function changes and induce spatiotemporal variation in electron emission and subsequent ion generation.
A new quasi-optical (QO) Electron Cyclotron Emission (ECE) transmission system has been established on the HL-3 tokamak, which includes a focusing QO mirror combination and a long-distance transmission line. This system was developed to meet the requirements for poloidal spatial resolution and the high signal-to-noise ratio needed for magnetohydrodynamic (MHD) instability studies using ECE on the HL-3. The QO mirror combination was installed inside the vacuum chamber for focusing. Laboratory test results, theoretical calculations, and synthetic ECE simulation results indicate that the Gaussian beam can meet the spatial resolution requirements for the accurate measurement of the MHD instability on the q = 1/2/3 surfaces, corresponding to the poloidal mode numbers m = 3/6/9. This includes good diagnostic poloidal spatial resolution for the important 2/1 and 3/2 modes. At the front end of the transmission line, a high-efficiency mode converter was designed to transition the TE 10 mode to the HE 11 mode for input into the transmission line, with an insertion loss of less than 1.5 dB. A 30 m long-distance corrugated oversized waveguide was constructed, with transmission losses ranging from 6 to 10 dB in the 60–120 GHz range. Polarization adjustment results show that the polarization offset and geometric spatial polarization angle change consistently, which can provide a reference for polarization adjustment in other complex structured transmission lines. As a result, the newly established ECE QO transmission system will provide strong support for future physics research involving ECE on the HL-3.
An electron emission control circuit of the switching regulator type operating at 100 kHz has been developed which maintains a constant emission current within 0.1% for a cathode power demand variation of approximately 100%. The power output stage has an efficiency of 67%, and the overall efficiency is 45% when driving a thoria-coated iridium cathode having a nominal resistance at operating temperature of 2.5 ohms. Under optimum conditions, the bus power demand is 1.75 W. The circuit is useful in controlling the electron emission current of ion sources in applications which involve a substantial variation of the cathode work function, such as oxygen partial pressure measurements over a large dynamic range.
Utilizing Lyman-alpha emission cross sections for H2 as secondary standards, absolute values of Lyman-alpha emission cross sections for CH4 have been obtained for electron impact energies varying from threshold to 100 eV. A crossed electron beam-molecular beam geometry was employed and the Lyman-alpha radiation was detected at 90 deg and 45 deg with respect to the incident electron beam by a solar blind photomultiplier in tandem with an oxygen filter. The results are compared with previous measurements. Appreciable differences among the various experimental data are found.
The transient charging and photon emission from the vacuum chamber testing of the Cooperative High Altitude Rocket Gun Experiment are studied. Graphs of the mother-daughter voltage versus time and high time resolution data related to the return current to the vehicle are examined. It is observed that for average sounding rocket densities of 10 to the -6th torr the slope of the voltage rise of the rocket begins to flatten 40 microsec after the onset of electron beam emission, and for higher gas pressure the rocket reaches a maximum voltage of 25 or 30 microsec after the onset of electron beam emission. The data reveal that the return current mechanism for the higher gas pressure is through the sheath.
Monolithic, millimeter wave “system-on-chip” (SoC) technology has been employed in heterodyne receiver integrated circuit radiometers in a newly developed Electron Cyclotron Emission Imaging (ECEI) system on the DIII-D tokamak for 2D electron temperature profile and fluctuation evolution diagnostics. Here, a prototype module operating in E-band (72-80 GHz) was first employed in a 2 x 10 element array that demonstrated significant improvements over the previous quasi-optical Schottky diode mixer arrays during the 2018 operational campaign of the DIII-D tokamak. For compatibility with International Thermonuclear Experimental Reactor (ITER) relevant scenarios on DIII-D, the SoC ECEI system was upgraded with 20 horn-waveguide receiver modules. Each individual module contains a University of California at Davis designed W-band (75 -110 GHz) receiver die that integrates a broadband low noise amplifier (LNA), a double balanced down-converting mixer, and a x4 multiplier on the local oscillator (LO) chain. A x2 multiplier and two IF amplifiers are packaged and selected to further boost the signal strength as well as downconvert the signal frequency. The upgraded W-band array exhibits > 30 dB additional gain and 20x improvement in noise temperature comparing with the previous Schottky diode radio frequency (RF) mixer input systems; an internal 8 times multiplier chain is used to bring down the LO frequency below 12 GHz, thereby obviating the need for a large aperture for quasi-optical LO coupling and replacing it with coaxial connectors. The horn-waveguide shielding housing avoids out-of-band noise interference on each individual module. The upgraded ECEI system plays an important role for absolute electron temperature evolution and fluctuation measurements for edge and core region transport physics studies.
This work presents an overview of recent and ongoing experimental measurements of core and edge turbulence across multiple confinement regimes using the Correlation Electron Cyclotron Emission (CECE) diagnostic at the ASDEX Upgrade (AUG) tokamak. A common goal among these investigations is to identify how the properties of the turbulent electron temperature fluctuations measured by CECE influence and regulate the unique transport characteristics of each confinement regime, including L-mode, I-mode, ELMy H-mode, and ELM-free H-mode. Optics and signal processing methods to aid in the analysis and interpretation of experimental turbulence results are also presented. These methods, and particularly the down-sampling and ensemble averaging method, are relevant to a wide variety of fusion and non-fusion applications.
Work performed on project titled, "Turbulent Transport Studies at ASDEX Upgrade Enabled by Correlation Electron Cyclotron Emission and nT-phase Diagnostic". We conducted an integrated project of experiment and model validation at ASDEX Upgrade (AUG) to expand knowledge of the underlying physics of high-performance, ELM-free regimes suitable for long pulse operation. Both the I-mode and QH-mode high-confinement regimes have potential as operating scenarios in a future reactor. Additional fluctuation measurements provided critical constraints on transport models, and elucidate the transport mechanisms associated with benevolent quasi-coherent modes in the edge and pedestal region of QH-mode and I-mode. This research expanded knowledge of turbulent-transport in tokamaks in support of ITER and other burning plasma experiments.