Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy Saving”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Leveraging Real-World Driving Data for Design and Impact Evaluation of Energy Efficient Control Strategies

Modeling and simulation are crucial in the development of advanced energy efficient control strategies. Utilizing real-world driving data as the underlying basis for control design and simulation lends veracity to projected real-world energy savings. Standardized drive cycles are limited in their utility for evaluating advanced driving strategies that utilize connectivity and on-vehicle sensing, primarily because they are typically intended for evaluating emissions and fuel economy under controlled conditions. Real-world driving data, because of its scale, is a useful representation of various road types, driving styles, and driving environments. The scale of real-world data also presents challenges in effectively using it in simulations. A fast and efficient simulation methodology is necessary to handle the large number of simulations performed for design analysis and impact evaluation of control strategies. In this study, two methods are presented of leveraging real-world data in both design optimization of energy efficient control strategies and in evaluating the real-world impact of those control strategies upon large-scale deployment. Through these methodologies, strategies with highest impact on energy savings were selected to be implemented as control algorithms. The developed algorithms were incorporated into a vehicle dynamics and powertrain control architecture implemented on a Cadillac CT6 demonstration vehicle. The control algorithms were then exercised on real-world driving scenarios to determine their impact on collective energy savings. The methodology utilizes the large-scale driving data sets maintained by the National Renewable Energy Laboratory to extract real-world driving scenarios and efficient simulation software tools. The insights obtained through this research help in guiding technology selection for energy efficient driving controls.

ARPA-E↗

Scalable Thin Light-Emitting Diode (LED) Light Sheet Platform

The goal of the Scalable Thin Light-Emitting Diode (LED) Light Sheet Platform project is to derisk the manufacturing scalability for a high chip count heterogeneous smart lighting platform, with the potential to enable significant energy savings through dynamic directional light control and custom. Specifically, the project derisks the scalability of a disruptive new computer controlled microassembly fabrication process SRI International is developing, to address fundamental cost barriers to mass production of high chip count systems. This is key for enabling mass adoption and thus maximum societal energy savings impact. The LED light sheet technology is a smart illumination platform that can be applied to lighting, signage, and display. It has features and a form factor similar to bendable or conformal OLED light sheets but uses more efficient LEDs with a remote phosphor layer that is very close to the LED to deliver a luminous efficacy that exceeds 125 lumen/Watt and enable > 50% Lighting Application Efficiency (LAE) energy savings. During Budget Period 1 (BP1), all of the BP1 milestones were successfully completed: (M2.0.1) Design demonstrator details that will meet the final project goals, (M6.1.1) Show lighting output model can predict illuminance, spatial, spectral distribution for specific light-sheet designs and use case, (M3.2.1) Automated loading supports 200 chip arrays, and (M3.3.1) Finish first interconnect process run for 200 chip array. The BP1 Go/No-Go Decision Point (G/NG 1) 200 chip demonstrator sample was in the process of final assembly and test at the end of BP1 on December 31, 2023. The objective was successfully achieved on January 16, 2024, when a wired 200-chip sample underwent confirmation testing that demonstrated a 93.75% first pass electrical yield that successfully exceeded the 75% first-pass electrical yield BP1 G/NG requirement. In addition, all 93.75% of the sample devices lit up, further demonstrating the ability to assemble and transfer small LED chips without damaging their functionality.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Large scale energy analysis and renovation strategies for social housing in the historic city of Venice

Social houses built after the Second World War to accommodate workers and low-income families represent one of the major energy consumers and greenhouse gas emitters in the residential sector. Plans for their renovation are underway in all European countries, and the process is more complicated for Italian cities due to the lack of space and the large number of historical buildings. This study addresses this challenge by proposing a methodology to renovate a low-income district in the city of Venice using CityBES to model and evaluate energy conservation measures. CityBES is a web-based tool that allows users to employ urban building energy modeling for large-scale energy and retrofit analyses of building stocks. In the case study conducted for Venice's Santa Marta district, due to the particular context, four common energy conservation measures covering both the building envelope and heat generation boilers have been applied. The evaluation of energy-saving performances at the district level showed that the four measures together achieved 67% energy savings, an abatement in energy cost equal to 67%, and annual carbon dioxide emissions reduction of 1.1 MtCO 2 . Furthermore, the case study demonstrates a method and workflow replicable for energy retrofit analysis of building stocks in other historical districts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design of Phase-Change Thermal Storage Device in a Heat Pump for Building Electric Peak Load Shaving: Preprint

Replacing carbon-intensive fossil fuel heating systems with electric heat pumps powered by renewables is a promising approach to decarbonize the building sector. However, one of the technical barriers of this approach is the large scale of heat demand, which will put excessive stress on the electricity grid. Integrating thermal energy storage (TES) into the heating systems can help alleviate this problem, by shifting thermal load and thus shaving peaks in the building electric load. Therefore, it is critical to understand how to design a thermal storage device in a heat pump for peak load shaving. In this study, we developed a numerical model for a cascaded vapor compression heat pump system integrating a phase change thermal storage device. This novel system can control the net thermal charging and discharging rate of the TES independently from the building's thermal load, which allows for precise control of electric power use. In the current study, we controlled the system to shave building electric peak load during a cold winter morning, and to charge TES during the relatively warm afternoon while still providing space heating. We used the model to evaluate the system performance with and without peak shaving. We also investigated the effect of PCM transition Tt on the peak reduction and electric energy saving potentials. The results show that peak shaving scheme effectively reduces the peak electric power consumption during a predefined discharge time window. When comparing to the no shaving case, for PCM Tt = 10 degrees C, the peak electric load reduction is 23.5%. When comparing to an air-source heat pump with back up electric heater, as Tt increases from 0 to 20 degrees C, the peak reduction increases from 46.1% to 50.9%. Integrating PCM Tt = 10 degrees C with peak shaving leads to the 45.5% of electric energy saving, which is the highest among the three transition temperatures.

electric energy saving↗

Real-Time Ecodriving Control in Electrified Connected and Autonomous Vehicles Using Approximate Dynamic Programing

Connected and automated vehicles (CAVs), particularly those with a hybrid electric powertrain, have the potential to significantly improve vehicle energy savings in real-world driving conditions. In particular, the ecodriving problem seeks to design optimal speed and power usage profiles based on available information from connectivity and advanced mapping features to minimize the fuel consumption over an itinerary. This paper presents a hierarchical multilayer model predictive control (MPC) approach for improving the fuel economy of a 48 V mild-hybrid powertrain in a connected vehicle environment. Approximate dynamic programing (DP) is used to solve the receding horizon optimal control problem, whose terminal cost is approximated with the base policy obtained from the long-term optimization. The controller was tested virtually (with deterministic and Monte Carlo simulation) across multiple real-world routes, demonstrating energy savings of more than 20%. The controller was then deployed on a test vehicle equipped with a rapid prototyping embedded controller. In-vehicle testing confirm the energy savings obtained in simulation and demonstrate the real-time ability of the controller.

Automation & Control Systems↗

IoT-Based Comfort Control and Fault Diagnostics System for Energy-Efficient Homes

This project studies an Internet of Things (IoT)-based comfort control and fault diagnostics system (referred as iComfort in this report) for energy-efficient homes. The system delivers an occupant-comfort-oriented thermal environment adaptive to fault scenarios and achieves HVAC energy savings in a cost-effective and straightforward way. This smart iComfort home system consists of the following key features. 1) Cost-effectiveness and scalability of the entire hardware and software system: The system includes low-cost temperature, humidity, and airflow sensors, and a Raspberry Pi-based local hub that interfaces with the cloud and IoT-enabled devices. The cost is low, not only for sensors, but also the costs associated with sensor installation, system setup and commissioning, data communication and storage, and data analytics (e.g., the development of automated fault detection and diagnosis (AFDD), as well as adaptive control strategies that are both computationally efficient and practical to implement). 2) Energy performance and user satisfaction: The system delivers user satisfaction and energy savings. This includes a) ease of use, b) optimal occupant thermal comfort, and c) accurate system feedback (e.g., low false alarm of AFDD strategies). 3) Favorable demonstrated prototype performance: The prototype tested at the Pacific Northwest National Laboratory (PNNL) Lab Homes demonstrates the accuracy of fault detections and diagnoses and shows thermal comfort improvement and energy savings through adaptive and optimal HVAC operations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Innovations in Sensors and Controls for Building Energy Management: Research and Development Opportunities Report for Emerging Technologies

Sensors, actuators, and controllers, which collectively serve as the backbone of cyberphysical systems for building energy management, are one of the core technical areas of investment for achieving the U.S. Department of Energy (DOE) Building Technologies Office's (BTO's) goals for energy affordability in the national building stock - both commercial and residential. In fact, an aggregated annual energy savings of 29% is estimated in the commercial sector alone through the implementation of efficiency measures using current state-of-the-art sensors and controls to retune buildings by optimizing programmable settings based on occupant schedules and comfort requirements, as well as detecting and diagnosing equipment operation and installation problems (Fernandez et al. 2017). Monitoring and control of building conditions and operations has advanced significantly, from the invention of the modern thermostat just before the start of the 20th century to the midcentury incorporation of direct digital control into devices, the introduction of open protocols and network communications at the end of the century, and finally the invention of cloud-based computing and additional advancements that have enabled remote operation and a proliferation of connected and intelligent devices in building automation. Despite this potential, however, two main challenges hinder widespread adoption of sensors and controls in building operations that can ensure savings for high-efficiency components and equipment (e.g., heat pumps, windows, and lighting devices), as well as additional savings from more sophisticated control architectures and algorithms. energy savings of 29% is estimated in the commercial sector alone through the implementation of efficiency measures using current state-of-the-art sensors and controls to retune buildings by optimizing programmable settings based on occupant schedules and comfort requirements, as well as detecting and diagnosing equipment operation and installation problems (Fernandez et al. 2017). Monitoring and control of building conditions and operations has advanced significantly, from the invention of the modern thermostat just before the start of the 20th century to the midcentury incorporation of direct digital control into devices, the introduction of open protocols and network communications at the end of the century, and finally the invention of cloud-based computing and additional advancements that have enabled remote operation and a proliferation of connected and intelligent devices in building automation. Despite this potential, however, two main challenges hinder widespread adoption of sensors and controls in building operations that can ensure savings for high-efficiency components and equipment (e.g., heat pumps, windows, and lighting devices), as well as additional savings from more sophisticated control architectures and algorithms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation of Three RTU Energy Efficiency Technologies

This project was part of an effort by CLEAResult and ComEd to evaluate the energy saving potential of emerging technologies in the Chicago area. This project focused on evaluating emerging technologies related to rooftop units (RTUs). An RTU with a single-stage compressor and a constant-speed fan with an induction motor was selected as the baseline for technology comparison. Three retrofit strategies were investigated. The first two involved replacing the single-stage compressor of an RTU by either a two-stage or variable-speed compressor and adding a variable frequency drive (VFD) to the constant speed fan. The use of a multi-/variable-stage compressor improves the part-load efficiency of the compressor which will ultimately result in annual energy savings as well as peak demand shaving in some cases where the design capacity of the RTU is larger than the maximum cooling load of the building space that it is serving. The third technology was the use of a high rotor pole switched reluctance motor (SRM) as a replacement for the constant-speed supply fan. The SRM was applied in single-speed, two-stage and variable-speed compressor RTUs. SRM motors run via reluctance torque. Their stator poles are driven by direct current (DC) power and require an inverter as well as active control when using alternating current (AC) power. This inherent property results in high efficiency over a range of operating conditions. It also exhibits higher efficiency compared to variable frequency drives (VFDs) since its switching frequency is much slower (SCE, 2018).The three technologies investigated are summarized below: 1) Replacing the single-speed compressor with a two-stage compressor and adding a VFD to the supply fan. 2)Replacing the single-speed compressor with a variable-speed compressor and adding a VFD to the supply fan. 3) Replacing the constant-speed induction motor of the supply fan with a high rotor pole SRM. DOE’s building simulation platform EnergyPlus and its graphical user interface OpenStudio were used to evaluate the energy-saving potential of upgrading RTUs, by leveraging experimental data from previous research.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Saver Guide: Tips on Saving Money and Energy at Home

Follow the simple tips in the Energy Saver guide to make your home more comfortable and easier to heat and cool--while you save money. This guide shows you how easy it is to cut your energy use at home and also on the road.

Guide, Tips, Money, Home, Saver, Consumer, Energy ↗

Consumer Benefits of Clean Energy: Energy Efficiency

Meeting national and state decarbonization goals requires a transition to clean energy technologies. Energy efficiency, demand flexibility, renewable energy and storage can reduce consumers’ electricity bills, lower total electricity system costs, and provide health and resilience benefits. Berkeley Lab developed a series of briefs that explore these consumer benefits of a clean energy transition. This brief focuses on energy efficiency benefits, and builds on prior analysis from Berkeley Lab’s Cost of Saved Energy database. We show that energy efficiency remains a low-cost energy and capacity resource; the levelized cost of saving energy for the programs included in the analysis is $\$0.02$/kilowatt-hour and the cost of saving peak demand is less $\$120$/kilowatt. Understanding the impact of the program mix, portfolio size, and duration of implementation for customer-funded energy efficiency portfolios can guide regulatory oversight of these programs, help utilities better utilize energy efficiency as a resource, and inform building energy decarbonization policies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Non-routine adjustments – towards standardizing M&V approach for quantifying the effects of static factors

The success of an energy management program relies on ensuring that the energy savings can be verified with an adequate level of certainty. Energy savings cannot be directly measured and hence have to be deduced by comparing the pre-retrofit energy consumption with post-retrofit energy consumption data adjusted to account for differences in conditions. These adjustments are needed, since conditions that influence energy consumption may not stay the same between pre- and postinstallation phase of the project. These adjustments can often be routine when accounting for factors like production volume and weather that are expected to change and are included in the energy consumption adjustment model. Existing measurement and verification (M&V) resources and guidance mostly concentrate on developing models for routine adjustment of one or more factors that normally change. On the other hand, there are factors (static) like product mix, operating hours, gross square area, etc. that are assumed to stay constant during normal conditions. However, in order to adapt to dynamic market conditions, the industries are forced to react thereby leading to changes to these static factors. Identifying these static factors that warrant adjustment, called non-routine event, along with quantifying their effect on energy consumption can be complex and lack of proper guidance can exacerbate this issue. This paper reviews some of the current work in terms of how non-routine events are defined, characterized, detected and quantified based on a review of existing M&V guidelines, protocols and other relevant literature. This work also reviewed some of the existing non-routine events and adjustment practices to understand how these different aspects are addressed along with a discussion on some of the key challenges and gaps in the current guidance.

Earni, Shankar↗

Building Efficiency Targeting Tool for Energy Retrofits (BETTER) Web Application (BETTER Web App) v1.0

The Building Efficiency Targeting Tool for Energy Retrofits (BETTER) V.1.0 web application identifies cost-saving energy and emissions reductions in buildings and portfolios, without site visits or complex modeling. With minimal data entry, BETTER benchmarks a building's or portfolio's energy use against peers; quantifies energy, cost, and greenhouse gas (GHG) reduction potential; and recommends energy efficiency measures for individual buildings or portfolios, targeting specific energy savings levels. The source code of BETTER's modular, cross-platform analytical engine has previously been disclosed (2019-001) and is available on GitHub and can be adopted, redeveloped, and redistributed freely under an open-source license, allowing users to incorporate BETTER's analytical capabilities into their own software platforms and tools. The BETTER V.1.0 web application, developed with the Django web-framework and the Model-View-Controller (MVC) architecture being disclosed here, provides a graphical user interface (GUI) for any user to view the software tutorials, download and upload a data entry template, configure and run the BETTER analyses, and view the final analytical reports.

Szum, Carolyn↗

A Comprehensive Analysis of Energy and Daylighting Impact of Window Shading Systems and Control Strategies on Commercial Buildings in the United States

Commercial buildings consume approximately 1.9 EJ of energy in the United States, 50% of which is for heating, cooling, and lighting applications. It is estimated that windows contribute up to 34% of the energy used for heating and cooling. However, window retrofits are not often undertaken to increase energy efficiency because of the high cost and disruptive nature of window installation. Highly efficient window technologies would also need shading devices for glare prevention and visual comfort. An automated window shading system with an appropriate control strategy is a technology that can reduce energy demand, maintain occupant comfort, and enhance the aesthetics and privacy of the built environment. However, the benefits of the automated shades currently used by the shading industry are not well studied. The topic merits an analysis that will help building owners, designers and engineers, and utilities make informed decisions using knowledge of the impact of this technology on energy consumption, peak demand, daylighting, and occupant comfort. This study uses integrated daylight and whole-building energy simulation to evaluate the performance of various control strategies that the shading industry uses in commercial office buildings. The analysis was performed for three different vintages of medium office buildings at six different locations in United States. The results obtained show the control strategies enabled cooling energy savings of up to 40% using exterior shading, and lighting energy savings of up to 25%. The control strategies described can help building engineers and researchers explore different control methods used to control shading in actual buildings but rarely discussed in the literature. This information will give researchers the opportunity to investigate potential improvements in current technologies and their performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Puerto Rico Energy Efficiency Scenario Analysis Tool (PREESAT)

The National Renewable Energy Laboratory (NREL) developed the Puerto Rico Energy Efficiency Scenario Analysis Tool (PREESAT) to allow stakeholders to estimate the long-term aggregate electricity consumption impacts of various energy efficiency measures in Puerto Rico’s residential, commercial, and industrial sectors. PREESAT is an energy accounting framework that addresses electricity use. These presentation slides provide a summary of the electrical sector in Puerto Rico and an overview of how the PREESAT tool can be used to project energy savings from various energy efficiency measures in the residential, commercial, and industrial sectors.

commercial↗

Implementation and validation of optimal start control strategy for air conditioners and heat pumps

Commercial buildings are responsible for approximately 20 % of the total energy consumption and greenhouse gas emissions in the United States. Over 85 % of these buildings lack building automation systems, and many are small (<50,000 square feet), underserved, and use rooftop units (RTUs) for heating, ventilation, and air-conditioning needs. Because these buildings lack proper energy management systems, several operational deficiencies lead to excess energy consumption. Studies have shown that managing the RTUs’ heating and cooling set points, schedules, setbacks, and optimal start can result in a 20 % to 25 % reduction in electricity consumption in small commercial buildings. These buildings typically use fixed schedules to start the RTUs 60 to 120 min before occupancy begins, which results in excess energy consumption. This paper presents research that demonstrates and evaluates the performance of four optimal start methods, which utilize data-based modeling as a key element in facilitating adaptive control in response to time-varying inputs while requiring minimal sensor inputs. The evaluation found energy savings in two commercial buildings equipped with RTUs by periodically alternating four different optimal start models during the cooling and heating season. The resulting energy savings are positive for all models and range from 2 to 5 kWh/day/unit. The units on the east side of the building showed higher savings, while interior units showed greater variability in savings due to the differences in capacities and room sizes. Savings were considerably greater during the heating season compared to the cooling season. The performance of all four models on Mondays was poor; models suggested a shorter optimal start time, which resulted in relatively larger errors. Finally, the future work will look at using a different model for the days after weekends and holidays.

42 ENGINEERING↗

Comparative study on the overall energy performance between photovoltaic and Low-E insulated glass units

In this report a novel semi-transparent building integrated photovoltaic (BIPV) laminate was developed and introduced in this paper. It was produced by cutting standard mono-crystalline silicon solar cells into small strips and then making electrical connections between each strip before laminating the cells between two layers of glass. The overall energy performance and energy saving potential of the BIPV insulated glass unit (IGU) under real world conditions were identified through a side by side comparative study. Compared to the reference IGU, the BIPV IGU had lower solar heat gain coefficient (SHGC) but much higher U-factor. The average HVAC electricity saving of the BIPV IGU was about 10% relative to the reference IGU. Daylighting measurement and analysis were carried out to evaluate the trade-offs associated with the BIPV IGU between daylight, glare, and lighting energy use. The results indicated that the BIPV IGU is better than the reference IGU in reducing discomfort glare. However, if the most conservative viewpoint near the window is used for the assessment, a lower transmittance BIPV IGU is required to bring the overall discomfort levels below the perceptible level. Lastly, the net energy saving potential associated with the novel BIPV IGU was identified based on the power, thermal and daylighting performance. On average, the BIPV IGU saved 16.8% of the total electricity use of the room. Further studies and improvement on the energy conversion efficiency of solar cells, the optimal transmittance as well as the thermal properties would make this technology more energy-efficient and affordable.

14 SOLAR ENERGY↗

Leveraging Multiple Connected Traffic Light Signals in an Energy-Efficient Speed Planner

Connecting automated vehicles to traffic lights can lead to significant energy savings by enabling them to pass through intersections in an energy-efficient way without unnecessary stops. A cellular-based communication system connecting multiple traffic lights can help realize the full potential of energy-efficient driving at intersections. Thus, we propose a hierarchical speed planner that can leverage information from multiple connected traffic lights. The proposed speed planner consists of two modules: a green window selector and a reference trajectory generator. The green window selector, based on Dijkstra’s algorithm, finds a series of "green windows" for connected traffic lights that builds an energy-optimal path for vehicles to follow. The reference trajectory generator finds optimal entering times, based on the selected green window at each intersection, and then computes reference trajectories. Deriving and using analytical optimal entering speeds as a function of entering times allows us to guarantee the computational simplicity suitable for real-time implementation. We also demonstrate how to balance energy and traffic flow perspectives in the reference trajectory generator. Lastly, a high-fidelity simulation framework is used to evaluate the proposed speed planner and quantify the extent to which it can save energy in various real-world urban route scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗