Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy-efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

The Interplay Between Climate and Urban Expansion on Building Energy Demand in Morocco

Understanding building energy demand is critical for addressing climate uncertainty challenges and ensuring sustainable urban growth. This study develops a building energy demand (BED) model to explore how climate variation and urban expansion affect residential and commercial space heating and cooling demands in Morocco for three scenarios, namely, 2005, 2018, and 2018 + 1.5 °C. The results show that coastal cities have lower heating and cooling needs due to the oceanic influence, while interior cities require significantly higher heating demand per-unit-floorspace. Between 2005 and 2018, urban growth increased total heating and cooling demand by 218.8 GWh, particularly in northern and coastal regions, despite per-unit-floorspace reductions in milder climates and improved building efficiency in 2018. Residential heating remains the dominant energy use, though commercial demand is significant in urban centers. Under the 2018 + 1.5 °C hypothetical scenario, heating demand across Morocco declines by 335.8 GWh compared to 2018, with urban areas amplifying this trend. Meanwhile, cooling demand increases slightly by 44.4 GWh, with major cities experiencing relative increases of up to 50%. These findings highlight a trade-off where reduced winter heating needs are partly offset by increased summer cooling demands in densely urbanized areas. In conclusion, the study identifies key urban hotspots for targeted interventions, emphasizing the need for energy-efficient building designs, climate-adaptive urban planning, and resilient energy management strategies to sustainably address shifting seasonal energy patterns.

Morocco↗

Technical, Economic, Energetic, and Environmental Evaluation of Pretreatment Strategies for Scaling Control in Brackish Water Desalination Brine Treatment

Effective pretreatment is essential for achieving long-term stable operation and high water recovery during the desalination of alternative waters. This study developed a process modeling approach for technical, economic, energetic, and environmental assessments of pretreatment technologies to identify the impacts of each technology treating brackish water desalination brine with high scaling propensity. The model simulations evaluated individual pretreatment technologies, including chemical softening (CS), chemical coagulation (CC), electrocoagulation (EC), and ion exchange (IX). In addition, combinations of these pretreatment technologies aiming at the effective reduction of key scaling constituents such as hardness and silica were investigated. The three evaluation parameters in this assessment consist of levelized cost of water (LCOW, $/m 3 ), specific energy consumption and cumulative energy demand (SEC|CED, kWh/m 3 ), and carbon dioxide emissions (CO 2 , kg CO 2-eq /m 3 ). The case study evaluated in this work was the desalination brine from the Kay Bailey Hutchison Desalination Plant (KBHDP) with a total dissolved solids (TDS) concentration of 11,000 mg/L and rich in hardness and silica. The evaluation of individual pretreatment units from the highest to lowest LCOW, SEC|CED, and CO 2 emissions in the KBHDP brine was IX > CS > EC > CC, CS > IX > EC > CC, and CC > CS > EC > IX, respectively. In the case of pretreatment combinations for the KBHDP, the EC + IX treatment combination was shown to be the best in terms of the LCOW and CO 2 emissions. The modeling and evaluation of these pretreatment units provide valuable guidance on the selection of cost-effective, energy-efficient, and environmentally sustainable pretreatment technologies tailored to desalination brine applications for minimal- or zero-liquid discharge.

14 SOLAR ENERGY↗

Updating the Building Science Advisor (BSA): A Tool to Assist in the Design of Durable Building Envelopes

Predicting the moisture durability of building envelope components remains challenging due to multiple influencing factors, including material selection, assembly positioning, local climate conditions, air tightness, interior environment, and construction quality. Building codes increasingly emphasize energy efficiency through enhanced insulation and tighter envelopes but offer limited guidance on moisture durability considerations. Consequently, builders face uncertainty, particularly as new materials and assemblies enter the market.The Building Science Advisor (BSA) is a free, web-based expert system developed to address these challenges by providing actionable insights into the moisture durability and energy efficiency of both new and retrofit wall designs. Recently updated, we are now providing version 3.0 of the tool. BSA features significant user interface improvements, enhancing navigation and user interaction through a refreshed, intuitive design. Additionally, the tool incorporates a newly developed database containing pre-simulated wall assembly cases, significantly reducing response times and improving the accuracy of moisture durability assessments. Furthermore, the updated BSA includes moisture content as a performance criterion, providing users with a more comprehensive understanding of moisture-related durability risks. These enhancements enable rapid, reliable assessments tailored to specific climate zones and local building practices. BSA continues to offer targeted guidance on wall retrofit scenarios and delivers access to an expanded library of location-specific building science resources.This paper describes these key updates, highlighting the enhanced features, expanded capabilities, and overall improvements to user experience and educational content. The paper includes a demonstration that illustrates how the revised BSA effectively supports practitioners in designing durable, energy-efficient building envelope assemblies.

Salonvaara, Mikael [ORNL] (ORCID:0000000318991554)↗

NLR Core Modeling & Decision Support Capabilities: FASTSim, RouteE, T3CO & OpenPATH

This project is part of the program area to develop and improve core capabilities for the Energy-Efficient Mobility Systems (EEMS) program that enable research, development and deployment of advanced mobility solutions and enhance the EEMS Program's ability to address system-level transportation challenges. Advancements to the Future Automotive Systems Technology Simulator (FASTSim), Route Energy Prediction Model (RouteE), Transportation Technology Total Cost of Ownership (T3CO) and Open Platform for Agile Trip Heuristics (OpenPATH) core capabilities under this project supports the overall EEMS Program goals to effectively evaluate energy and mobility impacts of future transportation technologies and services, and to identify the most promising pathways to reduce transportation costs and environmental harms, and to improve mobility access. This presentation was prepared for the 2026 Annual Merit Review of this project.

33 ADVANCED PROPULSION SYSTEMS↗

The relative importance of building design parameters in reducing energy use and sensible heat release from buildings in light of forecasted future weather data and building coverage ratio

Buildings typically have a 60-to-75-year lifespan before they require significant maintenance or modifications. However, most builders evaluate the performance of their new buildings using whole-building energy simulation tools based on the current typical meteorological year (TMY) file or actual meteorological year. The energy use consumption and sensible heat release pattern observed from buildings could potentially change based on shifting global climates. Therefore, the recommended energy-efficiency design parameters might also change during these periods. In this study, we evaluate the role of different building design parameters, such as material reflectivity, HVAC COP, and insulation values, on building energy usage and sensible heat release from buildings with different building coverage ratios (BCR), based on the current and future weather file TMY (fTMY) for the middle of the century (2040–2060). The role of sensible heat release from buildings is not accounted for accurately while estimating building energy usage in most whole-building energy simulations. The study conducts a series of whole-building energy simulation analyses using EnergyPlus to evaluate the role of different design parameters based on TMY and fTMY weather conditions. The analysis is conducted for two hot desert climatic cities: Phoenix (USA) and Abu Dhabi (UAE). The results show that, for the base case in a future climate, the sensible heat release is reduced by an average of 30% due to the reduced delta T between the surface and ambient air. Further, the results show an increase in total energy consumption by 5% annually. The results also show that, for buildings with traditional coatings, shorter buildings release more heat than taller buildings. On the other hand, for buildings with reflective paints, shorter buildings release less heat than taller buildings. The findings from this study can be used by policymakers, utility companies, and builders to better understand the relative role of different building design parameters while constructing new and retrofitting existing buildings.

Alhazmi, Mansour [King Fahd University of Petroleu↗

EVs@Scale Next-Gen Profiles - Fleet Utilization 2024

As part of the U.S. Department of Energy’s EVs@Scale initiative, the Next-Gen Profiles (NGP) project provides a comprehensive, data-driven analysis of electric vehicle (EV) and electric vehicle supply equipment (EVSE) operations across real-world fleet deployments. This paper presents findings from the NGP’s Fleet Utilization study, which investigates operational behavior and asset usage across seventeen EV fleets and two EVSE fleets, encompassing a wide range of vehicle types and use cases. Data collected from diverse sources—varying in format and temporal resolution—are first reformatted into a unified structure. From this harmonized dataset, a suite of rigorously defined performance metrics is calculated at an hourly cadence, enabling consistent cross-comparison of charging, routing, and other key operational behaviors. Amid rapidly increasing EV adoption and growing demands for energy-efficient fleet operations, the analysis reveals clear utilization trends—including diurnal and weekly activity cycles, differences in short versus long charging session dependencies, and route-specific energy usage patterns. These findings highlight the need for tailored infrastructure strategies and the deployment of advanced energy management systems, such as Distributed Energy Resource Management Systems (DERMS) and Site Energy Management Systems (SEMS), which can optimize charging schedules and mitigate peak loads. By leveraging anonymized, harmonized datasets and standardized metrics, this study offers critical insights into fleet behavior and performance, providing a foundation to improve operational efficiency, reduce costs, and enable the scalable deployment of electrified transportation.

Wells, Landon↗

A review of prefabricated overclad panels for building energy retrofits

Over 50% of existing buildings in the US were constructed before 1980 and lack modern, energy-efficient technologies. Despite the large number of old buildings, less than 2% of buildings are retrofitted each year with many of those retrofits consisting of small incremental improvements that often ignore the building envelope. The opaque building envelope affects 25% of building energy use equating to 10% of total US primary energy use. To meet decarbonization goals by 2035, the US must increase the rate of retrofit of existing building envelopes. The process of prefabrication is one potential opportunity to increase the rate of envelope retrofits and reduce costs. Prefabrication is the process of manufacturing construction components in a controlled environment before shipping them on-site to perform assembly of the construction. The process of prefabrication has been demonstrated to increase production efficiency, quality control, and rate of production. Prefabricated overclad panels, consisting of a cladding material and insulation designed to be installed over the existing envelope, have been successfully used to retrofit existing buildings in countries other than the US; however, the technology still has some barriers to major market adoption within the US. This paper will present a review of current implementations and demonstrations of prefabricated overclad panels. The review will include identification of panel types, materials, and applications and aims to identify barriers to retrofit market entry and widespread adoption.

Hayes, Nolan [ORNL] (ORCID:0000000332245718)↗

ChemComp: Compiling and Computing with Chemical Reaction Networks

The exponential growth in computing demands driven by scientific computing, data analytics, and artificial intelligence is pushing conventional CMOS-based high-performance computing systems to their physical and energy efficiency limits. As we approach the era of post-exascale computing, disruptive approaches are necessary to overcome these barriers and achieve substantial gains in energy efficiency. Analog and hybrid digital-analog computing systems have emerged as promising alternatives, offering the potential for orders-of-magnitude improvements in efficiency. Among these, biochemical computing stands out as a novel paradigm capable of leveraging the natural efficiency of chemical reactions, which have shown promise in solving optimization problems by converging to steady states. By scaling up reaction networks or reaction vessel sizes, biochemical systems present an opportunity to meet the high-performance demands of modern computing tasks. Despite their promise, significant theoretical and practical challenges remain, particularly in formulating and mapping computational problems to chemical reaction networks (CRNs) and designing viable biochemical computing devices. This paper addresses these challenges by introducing new ideas to ChemComp, a compilation and emulation framework for chemical computation. This work describes the mechanisms through which solutions to ordinary differential equations (ODEs) that can be represented as CRN systems can be achieved. Furthermore, we explain the design principles of an ODE dialect implemented as a multi-level intermediate representation (MLIR) compiler extension that will be coupled with existing infrastructure. We demonstrate the potential of our framework through a case study emulating a simplified chemical reservoir computing device. This work establishes foundational tools and methodologies necessary to harness the computational power of chemistry, paving the way for the development of energy-efficient, high-performance computing systems tailored to contemporary and future computational needs.

Bohm Agostini, Nicolas↗

Enhancing The Thermal Resistivity of Rigid Polyisocyanurate Foam Insulation

The development of rigid polyurethane foam insulation has garnered considerable attention because of its promising applications in the buildings and construction industry. Its low thermal conductivity makes it an attractive choice for improving energy performance in buildings. Current Rigid Polyurethane foams have thermal resistivity (R-value/in.) 5.5 to 6.5 h.ft2F/BTU/in.· that could be further improved by diminishing the heat transfer through the foam matrix. Nevertheless, minimizing both conduction (through gas and solid) and radiation simultaneously in porous solids is a significant challenge due to the trade-off between these two mechanisms. This study focuses on improving the R-value of the insulation foams via several strategies: such as type and the amount of the surfactants, blowing agent content and precooling and premixing polyol mixture. These methods optimized thermal properties of the PIR foams, achieving R/in. as high as 8.3. This excellent R/in. is anticipated to be a critical factor in significantly advancing the thermal insulation performance of rigid polyurethane cellular foams, thereby enhancing their efficacy in energy-efficient building applications.

Wanasinghe Mudiyanselage Pahala Gedara, Shiwanka V↗

Microwave-assisted catalytic conversion of waste biomass and plastic feedstocks via thermochemical routes

Microwave-assisted catalytic conversion of waste feedstocks to fuels and value-added chemicals shows incredible promise as an efficient pathway to support the U.S. Department of Energy’s vision toward strengthening the nation’s energy independence. Microwave-heated systems have the potential to outperform conventional technologies through energy-efficient heating and improved product selectivity. This chapter emphasizes microwave-assisted catalytic approaches for waste conversion, allowing maximum energy recovery and extraction of valuable chemicals from waste feedstock such as biomass and plastics while reducing undesired byproducts. A gap remains in understanding how microwaves interact with materials to enable rapid and selective heating, which is crucial for improving catalytic efficiency. This chapter attempts to address this knowledge gap by proposing mechanisms that explain the microwave-catalytic interactions for efficient conversion of biomass-plastic wastes. In addition, comparisons with conventional catalytic technologies as well as the potential for scale ups and future commercialization of microwave-catalytic waste conversion technologies are also discussed.

microwave-assisted catalytic conversion↗

LC-Opt: Benchmarking Reinforcement Learning and Agentic AI for End-to-End Liquid Cooling Optimization in Data Centers

Liquid cooling is critical for thermal management in high-density data centers with the rising AI workloads. However, machine learning-based controllers are essential to unlock greater energy efficiency and reliability, promoting sustainability. We present LC-Opt, a Sustainable Liquid Cooling (LC) benchmark environment, for reinforcement learning (RL) control strategies in energy-efficient liquid cooling of high-performance computing (HPC) systems. Built on the baseline of a high-fidelity digital twin of Oak Ridge National Lab's Frontier Supercomputer cooling system, LC-Opt provides detailed Modelica-based end-to-end models spanning site-level cooling towers to data center cabinets and server blade groups. RL agents optimize critical thermal controls like liquid supply temperature, flow rate, and granular valve actuation at the IT cabinet level, as well as cooling tower (CT) setpoints through a Gymnasium interface, with dynamic changes in workloads. This environment creates a multi-objective real-time optimization challenge balancing local thermal regulation and global energy efficiency, and also supports additional components like a heat recovery unit (HRU). We benchmark centralized and decentralized multi-agent RL approaches, demonstrate policy distillation into decision and regression trees for interpretable control, and explore LLM-based methods that explain control actions in natural language through an agentic mesh architecture designed to foster user trust and simplify system management. LC-Opt democratizes access to detailed, customizable liquid cooling models, enabling the ML community, operators, and vendors to develop sustainable data center liquid cooling control solutions.

Naug, Avisek [Hewlett Packard Enterprise]↗

Treyson Ricks - Intern Showcase Poster

Quinone-based sorbents offer a tunable, energy-efficient route to electrochemical CO2 capture, but systematic guidance for molecular design is lacking. Here, we report a high-throughput computational workflow that combines density functional theory (DFT) screening with machine-learning (ML) modeling to evaluate CO2 binding thermodynamics across several quinone derivatives, spanning benzoquinones, naphthoquinones, and anthraquinones. In addition to using solvents to stabilize the quinone anion and dianion, we studied the effect of ion-pairing on the reduction potentials and the CO2 binding energy. Automated Python scripts handled geometry optimizations and adduct-formation energies on an HPC cluster, reducing manual effort significantly. This integrated platform can uncover structure–property relationships and enables rapid in silico evaluation of untested candidates. We present one example from our workflow to showcase the capability of using quinones with ion-pairing to effectively capture CO2. Our approach paves the way for the rational selection of optimal quinone sorbents and can be extended with experimental thermochemical and kinetic data, alternative redox cycles, and stability assessments to accelerate development of next-generation electrochemical CO2 capture materials.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

Sensitivity analysis of design parameters in RowWise borehole layout for ground heat exchangers

Ground source heat pump systems offer a promising pathway toward energy-efficient building heating and cooling. The performance and cost-effectiveness of these systems heavily depend on the design of the ground heat exchanger (GHE), particularly the spatial placement of boreholes used in large commercial buildings. Among various borefield layout strategies, the RowWise approach generates and optimizes borehole configurations within irregular polygonal land boundaries, providing land-use efficiency and installation flexibility. While multiple geometric design parameters constrain the RowWise layout, their influence on the system thermal performance and total drilling requirements remains unclear. Thus, this study presents a sensitivity analysis of key design parameters influencing the RowWise layout of vertical borehole GHEs, including the perimeter spacing ratio, borehole spacing, borehole field rotation angle, and borehole length. GHEDesigner and Ray Tune are employed to generate and assess different RowWise configurations. A series of parametric simulations was conducted to quantify the impact of each parameter on geometric distribution, economic cost, and computational speed. The results provide critical insights into the sensitivity and relative importance of different design parameters of RowWise method, offering practical guidance for designers aiming to optimize GHE layouts by balancing thermal efficiency, land constraints, and economic feasibility.

Xu, Dikai [Purdue University]↗

Experimental Evaluation of a High-Performance Cold-Climate Heat Pump Using Tandem Vapor-Injection Compressors

A high-performance cold-climate heat pump (CCHP) was developed and experimentally validated through comprehensive laboratory and field testing. The system utilized two equal-size tandem vapor-injection (VI) compressors with an inter-stage flash tank to improve efficiency and capacity retention under subfreezing conditions. Laboratory testing was conducted on a 3-ton prototype in a controlled environmental chamber equipped with calibrated thermocouples, refrigerant-side mass flow and pressure transducers, and precision airflow measurement for energy balance verification. The prototype achieved heating coefficients of performance (COPs) of 4.4 at 47 °F, 3.1 at 17 °F, and 2.0 at –13 °F, while maintaining 88% of its rated heating capacity at –13°F. These results confirm strong low-temperature performance and indicate the potential for significant reductions in electric resistance backup use. A field prototype was installed and monitored in a residential building in Fairbanks, Alaska, during a heating season. Instrumentation included real-time power, temperature, and refrigerant state measurements to evaluate performance under dynamic outdoor conditions. The heat pump operated reliably down to –30 °F, delivering 75% of its rated heating capacity with a COP of 1.8, while maintaining stable operation, effective defrost control, and indoor comfort without auxiliary heating. The combined laboratory and field results demonstrate that the tandem VI compressor configuration provides a practical and energy-efficient approach for residential heat pumps designed for cold and very cold climate regions.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Field Demonstration and Adoption Impacts of an Affordable Thermoelectric Heat Pump

This study presents the design, field validation, and utility impacts of an air source heat pump that uses thermoelectric (TE) technology to provide supplemental heating at outside air temperatures below 17°F. Conventional heat pumps experience reduced heating capacity and COP at low outdoor temperatures due to the temperature difference between the source and demand sides of the vapor compression cycle. Consequently, during colder months, supplemental heating such as electric resistance or natural gas furnace is often needed to provide additional warmth, which increases the overall equipment and energy costs. To address this challenge, a TE subcooler (an array of solid-state, thermoelectric modules that provides heat pumping using non-vapor compression technique) is fabricated and integrated with the vapor compression cycle of a conventional air-source heat pump. In colder ambient conditions, TE subcooler exchanges heat with the refrigerant to provide additional subcooling, thereby enhancing the capacity of the heat pump. The operation of thermoelectric-integrated heat pump was demonstrated in an occupied single-family home in Nashville, TN. The TE subcooler increased the system’s heating capacity at 15°F outdoor temperature by 25–30% and reduced electricity demand by 10%. It also met the heating load in the house without supplemental electric resistance down to 5°F outdoors, delivering the additional heat at nearly 80% greater efficiency compared to electric resistance heating. With a modest first cost increment of 10–15% over conventional single-speed heat pumps, this approach offers a promising, energy-efficient solution to accelerate residential heat pump adoption in the U.S.

KRISHNAMOORTHY, Sreenidhi [Electric Power Research↗

Multi-Split Variable Refrigerant Flow (VRF) System Building Energy Simulations Using Performance Maps

Multi-split variable refrigerant flow (VRF) systems are highly energy-efficient HVAC (heating, ventilation and air conditioning) technologies that connect a single outdoor unit to multiple independent indoor terminal units using a common refrigerant circuit and a variable-speed compressor. Building energy simulations that incorporate VRF systems help model their unique operational characteristics and predict energy consumption in specific building designs. Traditionally, EnergyPlus models these systems by employing multiple sets of performance curves to characterize both individual terminal units and the outdoor unit. However, producing these curves is labor intensive and error prone, and they often do not capture all the key input and output variables. This paper introduces a novel approach that uses multi-dimensional performance maps to model VRF systems in building environments for space cooling. In this approach, performance maps are developed at the component level—separately for the outdoor unit and for each indoor terminal. The new modeling method is validated within EnergyPlus via a Python plug-in that contains a simple solver loop to coordinate the component-level, indoor, and outdoor unit maps. Furthermore, because performance maps can span more variables than traditional performance curves, they offer the opportunity to implement advanced controls, such as enhanced dehumidification and compressor modulation. A VRF air conditioner’s hardware system was modeled using the DOE/ORNL Heat Pump Design Model, which was automated to produce extensive performance maps for both the indoor and outdoor units.

Shen, Bo [ORNL] (ORCID:0000000336600393)↗

Separation and Recovery of High-Purity Dysprosium from Electric Vehicle Scrap Permanent Magnets Using Cyanex 572, a Cationic Extractant in a Membrane Solvent Extraction Process

Rare earth elements (REEs), especially heavy rare earth elements such as dysprosium (Dy), have gained immense attention globally due to their widespread use in many state-of-the-art technologies. Consequently, demand for REEs is increasing rapidly in comparison to their supply. Recycling of REEs from end-of-life (EoL) electronic waste (e-waste) can help to mitigate the increasing gap between the demand and supply of REEs. This study reports the separation and recovery of high-purity Dy from various feedstocks such as scrap permanent magnets (SPMs), electric vehicle (EV) magnets, and mixed rare earth oxides (REOs) using an economically viable and scalable membrane solvent extraction (MSX) process. First, the optimized conditions (organic phase composition and feed solution acid concentration) for the separation of Dy from light REEs such as neodymium (Nd) and praseodymium (Pr) were evaluated using liquid–liquid extraction. Thereafter, a multistage MSX process was developed to separate high purity (>99.5 wt %) Dy from Nd and Pr using Cyanex 572, a cationic extractant. Using feedstocks with varying initial compositions, the MSX process obtained 100% pure Dy with 63–96% Dy recovery in three to six stages with a maximum extraction rate of 2.9 g m–2 h –1 . Purity of the recovered Dy was confirmed via additional characterization such as scanning electron microscopy, energy dispersive X-ray spectroscopy, and X-ray diffraction. This novel MSX process holds immense potential for industry deployment for the separation of heavy and light rare REEs from a wide range of e-waste.

electrical vehicle magnets↗

Unexpected origin of the quantum efficiency reduction in long-wavelength (In,Ga)⁢N light-emitting diodes

Differential carrier lifetime (DCL) measurements were performed on c-plane In 𝑥 ⁢Ga 1−𝑥⁢ N/Ga⁢N single-quantum-well (QW) light-emitting diodes (LEDs) with varying indium-content QWs (x = 13.5%, 16%, 22%), emitting with violet, blue, and green wavelengths. The recombination lifetimes of LEDs were found to increase with increasing indium composition, resulting in increased carrier densities n measured by DCL. Extraction of the A coefficients, which are assumed to not vary with n, and of the effective B(n) and C(n) coefficients of the ABC model of the internal quantum efficiency (IQE) of QWs showed no significant changes in the A coefficient with increasing indium content [In] in the In 𝑥 ⁢Ga 1−𝑥 ⁢N QW, and a reduction in the B(n) and C(n) coefficients with increasing [In]. When looking at the Shockley-Read-Hall (SRH) recombination rate An, the radiative recombination rate B(n)𝑛 2 , and the Auger-Meitner (AM) recombination rate C(n)𝑛 3 , we observed that at any given n, the SRH rate is the same for the three [In] measured, while the radiative rate decreases (by up to approximately 9 times) and the AM rate decreases (by up to approximately 7 times) with increasing indium content. This shows that the larger reduction in radiative recombination rates relative to nonradiative recombination rates with increasing [In] is the largest contributor to the decreased quantum efficiencies of LEDs (the “green gap”) at any given n. While some of the reduction in the effective recombination coefficients B(n) and C(n) can be explained by the reduced wave-function overlaps of the QW with increasing indium content, the larger reduction of B(n) relative to C(n) motivates further study of the intrinsic recombination coefficients 𝐵 0 and 𝐶 0 of bulk In 𝑥 ⁢Ga 1−𝑥 ⁢N alloys and how they are related to the effective recombination coefficients B(n) and C(n) in QWs. The relative contributions of nonradiative recombination are enhanced at any given current density due to the sublinear relationship between the carrier density n and the current density. Thus, the solution to the green gap, up to any intrinsic limitations set by the indium content of the QW, from an IQE perspective, requires the design of long-wavelength (In,Ga)⁢N LEDs with improved wave-function overlaps that can operate with a lower carrier density at any given current density.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗