Significantly Improving Regional Seismic Amplitude Tomography at Higher Frequencies by Determining S -Wave Bandwidth

Characterizing regional seismic signals continues to be a difficult problem due to their variability. Calibration of these signals is very important to many aspects of monitoring underground nuclear explosions, including detecting seismic signals, discriminating explosions from earthquakes, and reliably estimating magnitude and yield. Amplitude tomography, which simultaneously inverts for source, propagation, and site effects, is a leading method of calibrating these signals. A major issue in amplitude tomography is the data quality of the input amplitude measurements. Pre-event and prephase signal-to-noise ratio (SNR) tests are typically used but can frequently include bad signals and exclude good signals. The deficiencies of SNR criteria, which are demonstrated here, lead to large calibration errors. To ameliorate these issues, we introduce a semi-automated approach to assess the bandwidth of a spectrum where it behaves physically. We determine the maximum frequency (denoted as F max ) where it deviates from this behavior due to inflections at which noise or spurious signals start to bias the spectra away from the expected decay. We compare two amplitude tomography runs using the SNR and new F max criteria and show significant improvements to the stability and accuracy of the tomography output for frequency bands higher than 2 Hz by using our assessments of valid S-wave bandwidth. We compare Q estimates, P/S residuals, and some detailed results to explain the improvements. Lastly, for frequency bands higher than 4 Hz, needed for effective P/S discrimination of explosions from earthquakes, the new bandwidth criteria sufficiently fix the instabilities and errors so that the residuals and calibration terms are useful for application.

58 GEOSCIENCES↗

Testbeds for test Readiness: Strategic Snapshot

Test bed engineering, monitoring for underground explosive and nuclear testing will be needed if the United States returns to a test posture of nuclear device testing. To maintain and rebuild the capability of test readiness, agile cost-effective test beds are needed and LANL as well as NNSS are the perfect locations to do this. Shallow and deep boreholes should be created to research containment science, diagnostic placement and optimization, coupling and emplacement science, tracer use for fracture and cratering research, and validation of test article performance.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Watchmen 3.0.0 Users Guide: Revision 6

Watchmen is a research software application developed by Pacific Northwest National Laboratory (PNNL) that incorporates the scientific and operational expertise for reviewing data from treaty monitoring radionuclide stations. The radionuclide stations are part of the International Monitoring System (IMS), a worldwide network to monitor for nuclear explosions. The data the IMS produces are critical to determine if a radionuclide release event is from a nuclear explosion. Stations deliver their measurements and system status to the International Data Centre (IDC), which forwards it via email to all subscribers. Watchmen is capable of processing data from several radioxenon station types.

97 MATHEMATICS AND COMPUTING↗

Watchmen 3.1.0 Users Guide: Revision 7

Watchmen is a research software application developed by Pacific Northwest National Laboratory (PNNL) that incorporates the scientific and operational expertise for reviewing data from treaty monitoring radionuclide stations. The radionuclide stations are part of the International Monitoring System (IMS), a worldwide network to monitor for nuclear explosions. The data the IMS produces are critical to determine if a radionuclide release event is from a nuclear explosion. Stations deliver their measurements and system status to the International Data Centre (IDC), which forwards it via email to all subscribers. Watchmen is capable of processing data from several radioxenon station types.

97 MATHEMATICS AND COMPUTING↗

Watchmen v3.2.0 User Guide: Revision 8

Watchmen is a research software application developed by Pacific Northwest National Laboratory (PNNL) that incorporates the scientific and operational expertise for reviewing data from treaty monitoring radionuclide stations. The radionuclide stations are part of the International Monitoring System (IMS), a worldwide network to monitor for nuclear explosions. The data the IMS produces are critical to determine if a radionuclide release event is from a nuclear explosion. Stations deliver their measurements and system status to the International Data Centre (IDC), which forwards it via email to all subscribers. Watchmen is capable of processing data from several radioxenon station types.

97 MATHEMATICS AND COMPUTING↗

Watchmen 3.3.0 User Guide: Revision 9

Watchmen is a research software application developed by Pacific Northwest National Laboratory (PNNL) that incorporates the scientific and operational expertise for reviewing data from treaty monitoring radionuclide stations. The radionuclide stations are part of the International Monitoring System (IMS), a worldwide network to monitor for nuclear explosions. The data the IMS produces are critical to determine if a radionuclide release event is from a nuclear explosion. Stations deliver their measurements and system status to the International Data Centre (IDC), which forwards it via email to all subscribers. Watchmen is capable of processing data from several radioxenon station types.

97 MATHEMATICS AND COMPUTING↗

A flow-through gamma detection system for sub-surface radioxenon tracer measurements in LYNM PE1

A continuous flow-through, real-time radioxenon sensor array has been designed to monitor either 127 Xe or 133 Xe tracer gas as part of a series of underground chemical explosions in the Low-Yield Nuclear Monitoring (LYNM) Physics Experiment 1 (PE1). The sensors are pairs of shielded thallium-doped sodium iodide gamma-ray detectors that surround a gas measurement chamber. Each measurement chamber is connected to a sampling location in the geology surrounding the chemical explosion or in the access tunnel. The first experiment in the series, PE1 A, occurred in 2023 and the system quantified the 127 Xe tracer gas in the gas sampling lines for four weeks following the experiment execution. The array generated a set of radioxenon concentration time series with a 15-minute resolution that will be used to refine subsurface gas transport models.

Gamma-ray coincidence detection↗

Modular initiator with integrated optical diagnostic

A slapper detonator which integrally incorporates an optical wavequide structure for determining whether there has been degradation of the explosive in the explosive device that is to be initiated by the detonator. Embodiments of this invention take advantage of the barrel-like character of a typical slapper detonator design. The barrel assembly, being in direct contact with the energetic material, incorporates an optical diagnostic device into the barrel assembly whereby one can monitor the state of the explosive material. Such monitoring can be beneficial because the chemical degradation of the explosive plays an important in achieving proper functioning of a detonator/initiator device.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Explosion Source Models and the Scattering Origin of Regional Phases from SPE Phase 1 Coda Spectral Ratios: Monitoring Implications –Discrimination and Yield Estimation

The Source Physics Experiment (SPE) explosions provide comprehensive ground truth information, and near-source recordings that are rarely available in typical monitoring scenarios. Here, we analyze these data together with local and regional distance recordings to isolate source and propagation effects, and to potentially improve monitoring at distance. We examine source spectral ratios, which can be measured to high precision by taking advantage of many SPE and independently operated stations, as well as the redundancy available from coda waves. Classical source models (Mueller and Murphy, 1971, MM71; Denny and Johnson, 1991, DJ91) predict the source ratios poorly; however, a hybrid model (MM71 with DJ91 cavity radii) performs better. We observe a distinct spectral modulation at 6-9 Hz that is not predicted by classical models, most likely caused by short period surface waves (Rg) interfering with those produced by spallation of near surface layers. The same modulation is observed for compressional (P) and shear (S) waves at distance, indicating that local and regional phases originate as near-source Rg that is scattered into body waves. The scattering process must be accounted for quantitatively to best use remotely recorded signals to monitor treaty compliance, discriminate event types, and estimate explosion yields over broad regions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reverse Time Migration of Explosion-generated Infrasound and Ground-Coupled Airwaves

Accurately locating sources of seismic and infrasonic energy is integral to global monitoring of earthquakes and explosions. Infrasound arrivals times can be used to calculate the origins of events that generate acoustic energy. Picking times of emergent infrasound arrivals, however, can be difficult and prone to uncertainty. Reverse time migration (RTM) is a waveform based location method that does not rely on picked arrival times. Here we use RTM to locate a known chemical explosion that generated acoustic and acoustic-to-seismic signals on 26 and 108 receivers, respectively. All location predictions are less than 24 km from the known location with time errors of less than three minutes. We find strong overall agreement between our results and those of existing RTM and arrival time based methods. Our initial results suggest that RTM is a promising method of event location using acoustic arrivals recorded on both infrasound and seismic instrumentation.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Measurement of Argon-37 Background Concentrations in the Atmosphere

Radioisotopes of noble gases, primarily xenon and argon, are important indicators of underground nuclear explosions. The Comprehensive Nuclear-Test-Ban Treaty (CTBT) includes monitoring capabilities to identify potential nuclear explosions conducted in violation of the CTBT. This monitoring currently focuses on measurement of the xenon isotopes 133 Xe, 135 Xe, 131 mXe and 133 mXe. However, it is predicted that within 100 days of an underground nuclear explosion (UNE) 37 Ar would be released to the atmosphere at higher concentrations than xenon isotopes (Haas et al. 2010). Therefore, inclusion of 37 Ar measurement capabilities at atmospheric International Monitoring System (IMS) stations could improve the capability to detect a nuclear explosion. At an IMS station, it could be difficult to determine what constitutes an elevated concentration as a result of an UNE without first understanding the expected range of background concentrations. This work describes our analysis of atmospheric samples for 37 Ar to evaluate the range of background concentrations. The range of 37 Ar concentrations measured in atmospheric air samples was relatively narrow ranging between less than 1 mBq/m 3 to greater than 2 mBq/m 3 . The average atmospheric concentration of all samples was 0.98 mBq/m 3 , with a standard deviation of 0.5 mBq/m 3 . This is consistent with previous published results. The results presented here demonstrate the capability to detect background concentrations of 37 Ar in atmospheric air.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison of near-background concentrations of Argon-37 and Xenon-133 in the Atmosphere

Radioisotopes of noble gases xenon and argon can be important indicators of underground nuclear explosions. The Comprehensive Nuclear-Test-Ban Treaty (CTBT) includes monitoring capabilities to identify potential nuclear explosions conducted in violation of the CTBT. This monitoring currently focuses on measurement of the xenon isotopes 133Xe, 135Xe, 131mXe and 133mXe. However, it is predicted that within 100 days of an underground nuclear explosion (UNE) 37Ar would be released to the atmosphere at higher concentrations than xenon isotopes (Haas et al. 2010) and with a higher signal to background ratio, depending on the radioxenon background levels. Therefore, inclusion of 37Ar measurement capabilities at atmospheric International Monitoring System (IMS) stations may represent an improvement in the capability to detect a nuclear explosion. At an IMS station, it could be difficult to determine what constitutes an elevated concentration as a result of an UNE without first understanding the expected range of background concentrations. This work describes our analysis of atmospheric samples for 37Ar to evaluate the range of background concentrations. Samples were collected at multiple locations, with approximately half coming from a sampler co-located with an IMS xenon monitoring station (RN75). The range of 37Ar concentrations measured in atmospheric air samples was relatively narrow; for samples considered detectable, the minimum and maximum measured concentrations were 0.56 and 2.3 mBq/m3, respectively. Comparison of 37Ar and 133Xe concentrations measured at the IMS station indicated some correlation between the measured concentrations. The results presented here demonstrate the capability to detect background concentrations of 37Ar in atmospheric air and provide a basis for potential implementation of 37Ar monitoring at IMS stations.

Fritz, Brad G.↗

Stockpile stewardship past, present, and future

The U.S. National Academies released a report in 2012 on technical issues related to the Comprehensive Test Ban Treaty. One important question addressed therein is whether the U.S. could maintain a safe, secure, and reliable nuclear-weapons stockpile in the absence of nuclear-explosion testing. Here we discuss two main conclusions from the 2012 Academies report, which we paraphrase as follows: 1) Provided that sufficient resources and a national commitment to stockpile stewardship are in place, the U.S. has the technical capabilities to maintain a safe, secure, and reliable stockpile of nuclear weapons into the foreseeable future without nuclear-explosion testing. 2) Doing this would require: a) a strong weapons science and engineering program that addresses gaps in understanding; b) an outstanding workforce that applies deep and broad weapons expertise to deliver solutions to stockpile problems; c) a vigorous, stable surveillance program that delivers the requisite data; d) production facilities that meet stewardship needs. We emphasize that these conclusions are independent of CTBT ratification-they apply provided only that the U.S. continues its nuclear-explosion moratorium.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Estimating Explosion Yields Using Moment Tensor Solutions and Seismic Moment

We report seismic moment, a measurable and well-understood quantity of seismic sources, is used to estimate the yield of explosions. Application of such a method in the past, as in the manner of m b -derived yields, has been complicated by the effect of variations in the explosion working point, depth, and secondary source effects (such as spalling and tectonic release) on the observed moment. We start using the full (six-element) moment tensor solution, which can capture the relevant source physics and, at least in theory, better isolate the primary explosion source. The moment-to-yield ratio is then estimated using an explosion source model which, provided with emplacement conditions, can relate the two parameters. We discuss the major sources of uncertainty associated with the method, and calibrate it with chemical and nuclear explosions at the Nevada National Security Site. We then apply the method to published moment tensor solutions for the six declared North Korean nuclear explosions that occurred between 2006 and 2017. The results are mostly consistent with other yield estimates made using a variety of high-frequency methods. This technique is a new approach to estimating explosive yield and simple to implement, as much of the complexity is captured by the source models.

58 GEOSCIENCES↗

Comparison of Surface Phenomena Created by Underground Chemical Explosions in Dry Alluvium and Granite Geology From Fully Polarimetric VideoSAR Data

Phase I of the Source Physics Experiment (SPE) series involved six underground chemical explosions, all of which were conducted at the same experimental pad. Research from the sixth explosion of the series (SPE-6) demonstrated that polarimetric synthetic aperture radar (PolSAR) is a viable technology for monitoring an underground chemical explosion when the geologic structure is Cretaceous granitic intrusive. It was shown that a durable signal is measurable by the H/A/α polarimetric decomposition parameters. After the SPE-6 experiment, the SPE program moved to the Phase II location, which is composed of dry alluvium geology (DAG). The loss of wavefront energy is greater through dry alluvium than through granite. In this article, we compare the SPE-6 analysis to the second DAG (DAG-2) experiment. We hypothesize that despite the geology at the DAG site being more challenging than at the Phase I location, combined with the DAG-2 experiment having a 3.37 times deeper scaled depth of burial than the SPE-6, a durable nonprompt signal is still measurable by a PolSAR sensor. We compare the PolSAR time-series measures from videoSAR frames, from the SPE-6 and DAG-2 experiments, with accelerometer data. We show which PolSAR measures are invariant to the two types of geology and which are geology dependent. We compare a coherent change detection (CCD) map from the DAG-2 experiment with the data from a fiber-optic distributed acoustic sensor to show the connection between the spatial extent of coherence loss in CCD maps and spallation caused by the explosion. Finally, we also analyze the spatial extent of the PolSAR measures from both explosions.

42 ENGINEERING↗

CORRTEX Diagnostic Deployment for the SPE-III experiment, 24 July 2012: Fielding Report and Preliminary Data Analysis

The Continuous Reflectometry for Radius vs Time Experiments (CORRTEX) diagnostic system was deployed for the third explosives test in the Source Physics Experiment (SPE) sequence to monitor and verify several conditions of the experiment including the detonation velocity of the explosive package and functioning of explosive initiators. Six distance-marked coaxial cables were installed on the SPE-III explosives canister, and key locations documented through along-cable length measurements and photography. CORRTEX uses electrical-pulse time-domain reflectometry to continuously record the two-way transit time (TWTT) of the cables. As the shock front of the detonation advances, the coaxial cable is shorted or destroyed, and the resulting TWTT also decreases. Interpretation of these changes as a function of TWTT can be converted to positional measurements using known parameters of the cables.

47 OTHER INSTRUMENTATION↗

What can football tell us about nuclear testing?

When football fans in a stadium cheer loudly enough, it can create a seismic signal. But how do we know cheering is the cause and not something else? Scientists at Los Alamos National Laboratory study how to differentiate between “nuisance alarms” – like “fanquakes,” earthquakes, or mine explosions – and an underground nuclear test. This information helps improve tools for international nuclear test treaty monitoring – and makes the world safer.

58 GEOSCIENCES↗

Direct Real-Time Detection of Vapors from Explosive Compounds

The real-time detection of vapors from low volatility explosives including PETN, tetryl, RDX and nitroglycerine along with various compositions containing these substances is demonstrated. This was accomplished with an atmospheric flow tube (AFT) using a non-radioactive ionization source and coupled to a mass spectrometer. Direct vapor detection was demonstrated in less than 5 seconds at ambient temperature without sample pre-concentration. The several seconds of residence time of analytes in the AFT provides a significant opportunity for reactant ions to interact with analyte vapors to achieve ionization. This extended reaction time, combined with the selective ionization using the nitrate reactant ions (NO3- and NO3-•HNO3), enables highly sensitive explosives detection. Observed signals from diluted explosive vapors indicate detection limits below 10 ppqv using selected ion monitoring (SIM) of the explosive-nitrate adduct at m/z 349, 378, 284 and 289 for tetryl, PETN, RDX and NG respectively. Also provided is a demonstration of the vapor detection from 10 different energetic formulations, including double base propellants, plastic explosives and commercial blasting explosives using SIM for the NG, PETN and RDX product ions.