Search NASA⌕ Search

SEARCH · Search NASA

Results for “FINGER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Compact Telerobot Hand

Anthropomorphic telerobotic hand contains actuators, joints, sensors, and complex wiring harnesses. Glove protects interior components of hand from dirt and damage. Imitates motions of human fingers and wrist in lifelike and dexterous way. Incorporates pitch/yaw joints in wrist and head knuckles. Hand modular; so fingers removable, interchangeable units. Feature simplifies servicing and maintenance, which must be done frequently in such complex mechanism.

Rosheim, Mark↗

Importance of numerosity and distribution of articulations within the digits, wrists, and arms of telemanipulators confronted with dextrous assembly tasks

This study was conducted to evaluate the impact of successive exclusion of degrees-of-freedom within digits (thumb and index finger) and wrist when performing tasks demanding varying degrees of end effector kinematic complexity. The analysis was performed by successive constraining articulations in the fingers (thumb and index) and wrists or human subjects via splints, and then timing performance of part movement, positioning, and assembly operations requiring different levels of kinematic freedom. Analysis of performance times showed that transferring degrees-of-freedom, or articulations, from the digits to the wrist and arm had little or no material affect upon manipulation performance times if wrist and arm kinematics were unrestricted. If wrist and arm kinematics are not constrained and are of high-quality, our findings show that transferring kinematic freedom from the digits to the wrist and arms or remote end effectors offers limited or no consequence in terms of remote assembly operations. The importance of such findings, in terms of development and implementation of commercially attractive telemanipulators, is discussed.

Wiker, Steven F.↗

Grasp synthesis for planar and solid objects

This paper presents an analysis of the mechanics for multifingered grasps of planar and solid objects. Squeezing and frictional effects between the fingers and the grasped objects is fully visualized through our approach. An algorithm for qualitively choosing the grasp points is developed based on the mechanics of grasping. It is shown further that our method can be easily extended for the soft-fingered grasp model where the torsional moments along the contact normals can be transmitted through the grasp points.

Chen, Yu-Che↗

Investigation of hand capabilities under a variety of performance conditions and an attempt to explain performance differences

Human capabilities such as dexterity, manipulability, and tactile perception are unique and render the hands as a very versatile, effective and a multipurpose tool. This is especially true for environments such as the EVA environment. However, with the use of the protective EVA gloves, there is much evidence to suggest that human performance decreases. In order to determine the nature and cause of this performance decrement, several performance tests were run which studied the effects of gloves on strength, tactile feedback, and range of motion. Tactile sensitivity was measured as a function of grip strength, and the results are discussed. Equipment which was developed to measure finger range of motion along with corresponding finger strength values is discussed. The results of these studies have useful implications for improved glove design.

Bishu, Ram R.↗

A combined electron beam/optical lithography process step for the fabrication of sub-half-micron-gate-length MMIC chips

Advanced radar and communication systems rely heavily on state-of-the-art microelectronics. Systems such as the phased-array radar require many transmit/receive (T/R) modules which are made up of many millimeter wave - microwave integrated circuits (MMIC's). The heart of a MMIC chip is the Gallium Arsenide (GaAs) field-effect transistor (FET). The transistor gate length is the critical feature that determines the operating frequency of the radar system. A smaller gate length will typically result in a higher frequency. In order to make a phased array radar system economically feasible, manufacturers must be capable of producing very large quantities of small-gate-length MMIC chips at a relatively low cost per chip. This requires the processing of a large number of wafers with a large number of chips per wafer, minimum processing time, and a very high chip yield. One of the bottlenecks in the fabrication of MIMIC chips is the transistor gate definition. The definition of sub-half-micron gates for GaAs-based field-effect transistors is generally performed by direct-write electron beam lithography (EBL). Because of the throughput limitations of EBL, the gate-layer fabrication is conventionally divided into two lithographic processes where EBL is used to generate the gate fingers and optical lithography is used to generate the large-area gate pads and interconnects. As a result, two complete sequences of resist application, exposure, development, metallization and lift-off are required for the entire gate structure. We have baselined a hybrid process, referred to as EBOL (electron beam/optical lithography), in which a single application of a multi-level resist is used for both exposures. The entire gate structure, (gate fingers, interconnects and pads), is then formed with a single metallization and lift-off process. The EBOL process thus retains the advantages of the high-resolution E-beam lithography and the high throughput of optical lithography while essentially eliminating an entire lithography/metallization/lift-off process sequence. This technique has been proven to be reliable for both trapezoidal and mushroom gates and has been successfully applied to metal-semiconductor and high-electron-mobility field-effect transistor (MESFET and HEMT) wafers containing devices with gate lengths down to 0.10 micron and 75 x 75 micron gate pads. The yields and throughput of these wafers have been very high with no loss in device performance. We will discuss the entire EBOL process technology including the multilayer resist structure, exposure conditions, process sensitivities, metal edge definition, device results, comparison to the standard gate-layer process, and its suitability for manufacturing.

Sewell, James S.↗

Neural mechanisms of kinesthesia

Our primary interest is in where the signals for position and movement of the limbs originate and how the information is encoded. Humans can independently sense the positions and movements of their limbs in the absence of vision, and their senses are derived from mechanoreceptors located in the limbs. Receptors in muscles, skin and joints are potential sources of position and movement signals, but how (and whether) each of these groups contributes to kinesthesia remains uncertain. Recent evidence indicates that a sense of static-position derives from length receptors in muscle, whereas receptors in the skin, and possibly though not likely the joints, can signal movement of a limb but not its static position. At present, we are examining the consequences of not having a static-position sense at the fingers apart from an inability to detect very slow displacements. Using a more demanding test, we have found no substantial difference in the accuracy of reproducing target positions passively imposed on the MCP joint and the proximal interphalangeal (PIP) joint of the index finger. Our working hypothesis is that subjects normally use movement sense mechanisms to detect displacements, probably because they are faster, but how (or whether) subjects manage to obtain an absolute position reference with only a movement sense available remains unknown and is an issue under investigation.

Clark, Francis J.↗

Manual discrimination of force

Optimal design of human-machine interfaces for teleoperators and virtual-environment systems which involve the tactual and kinesthetic modalities requires knowledge of the human's resolving power in these modalities. The resolution of the interface should be appropriately matched to that of the human operator. We report some preliminary results on the ability of the human hand to distinguish small differences in force under a variety of conditions. Experiments were conducted on force discrimination with the thumb pushing an interface that exerts a constant force over the pushing distance and the index finger pressing against a fixed support. The dependence of the sensitivity index d' on force increment can be fit by a straight line through the origin and the just-noticeable difference (JND) in force can thus be described by the inverse of the slope of this line. The receiver operating characteristic (ROC) was measured by varying the a priori probabilities of the two alternatives, reference force and reference force plus an increment, in one-interval, two-alternative, forced-choice experiments. When plotted on normal deviate coordinates, the ROC's were roughly straight lines of unit slope, thus supporting the assumption of equal-variance normal distributions and the use of the conventional d' measure. The JND was roughly 6-8 percent for reference force ranging from 2.5 to 10 newtons, pushing distance from 5 to 30 mm, and initial finger-span from 45 to 125 mm. Also, the JND remained the same when the subjects were instructed to change the average speed of pushing from 23 to 153 mm/sec. The pushing was terminated by reaching either a wall or a well, and the JND's were essentially the same in both cases.

Pang, Xiao-Dong↗

Vibratory tactile display for textures

We have developed a tactile display that produces vibratory stimulus to a fingertip in contact with a vibrating tactor matrix. The display depicts tactile surface textures while the user is exploring a virtual object surface. A piezoelectric actuator drives the individual tactor in accordance with both the finger movement and the surface texture being traced. Spatiotemporal display control schemes were examined for presenting the fundamental surface texture elements. The temporal duration of vibratory stimulus was experimentally optimized to simulate the adaptation process of cutaneous sensation. The selected duration time for presenting a single line edge agreed with the time threshold of tactile sensation. Then spatial stimulus disposition schemes were discussed for representation of other edge shapes. As an alternative means not relying on amplitude control, a method of augmented duration at the edge was investigated. Spatial resolution of the display was measured for the lines presented both in perpendicular and parallel to a finger axis. Discrimination of texture density was also measured on random dot textures.

Ikei, Yasushi↗

A well-posed numerical method to track isolated conformal map singularities in Hele-Shaw flow

We present a new numerical method for calculating an evolving 2D Hele-Shaw interface when surface tension effects are neglected. In the case where the flow is directed from the less viscous fluid into the more viscous fluid, the motion of the interface is ill-posed; small deviations in the initial condition will produce significant changes in the ensuing motion. This situation is disastrous for numerical computation, as small round-off errors can quickly lead to large inaccuracies in the computed solution. Our method of computation is most easily formulated using a conformal map from the fluid domain into a unit disk. The method relies on analytically continuing the initial data and equations of motion into the region exterior to the disk, where the evolution problem becomes well-posed. The equations are then numerically solved in the extended domain. The presence of singularities in the conformal map outside of the disk introduces specific structures along the fluid interface. Our method can explicitly track the location of isolated pole and branch point singularities, allowing us to draw connections between the development of interfacial patterns and the motion of singularities as they approach the unit disk. In particular, we are able to relate physical features such as finger shape, side-branch formation, and competition between fingers to the nature and location of the singularities. The usefulness of this method in studying the formation of topological singularities (self-intersections of the interface) is also pointed out.

Baker, Gregory↗

Gas near the center of 30 Doradus as revealed by Hubble Space Telescope images

We present images of a 40 pc region of the 30 Doradus nebula centered about 1 arcminute north of the luminous star cluster R136 in the Large Magellanic Cloud. The region was imaged with the Hubble Space Telescope (HST) Wide Field Camera through H alpha, (S II), and stellar continuum filters. These data allow us to examine this region of star formation and the breakup of the cloud around R136 on a scale of 0.027 pc per pixel. We also present a complementary ground-based echelle spectrum of the H alpha and (N II) emission lines in this region. In the images one sees an extensive filamentary structure surrounding regions that have been hollowed out by R136 and other massive stars in the area. The (S II) image shows a sharper, more filamentary appearance than the H alpha image, and the filaments are offset in (S II) generally away from R136. These characteristics are indicative of ionization fronts that are outlining the neutral material and dust features. We also find fingers of enhanced (S II) emission located about 90 sec to the northwest of R136. The (S II) fingers appear to be readiating generally from a common region, and we suggest that they are composed of material ablated from the high density gas of the ionization fronts and entrained with the flow of the stellar winds from R136. We find that a small knot of emission resolves into two shells of about 0.5 pc diameter, each of which encircles one or two stars. One of the stars has been identified as an early main-sequence O star by Walborn & Blades (1987), and the shell could be a young wind-blown bubble. We also find a parabolic-shaped arc at the head of a long cone that opens up away from R136. The arc is located near a luminous candidate protostar identified by Hyland et al. (1992).

Hunter, Deidre A.↗

Circuit For Control Of Electromechanical Prosthetic Hand

Proposed circuit for control of electromechanical prosthetic hand derives electrical control signals from shoulder movements. Updated, electronic version of prosthesis, that includes two hooklike fingers actuated via cables from shoulder harness. Circuit built around favored shoulder harness, provides more dexterous movement, without incurring complexity of computer-controlled "bionic" or hydraulically actuated devices. Additional harness and potentiometer connected to similar control circuit mounted on other shoulder. Used to control stepping motor rotating hand about prosthetic wrist to one of number of angles consistent with number of digital outputs. Finger-control signals developed by circuit connected to first shoulder harness transmitted to prosthetic hand via sliprings at prosthetic wrist joint.

Bozeman, Richard J., Jr.↗

Thermal Strap Increases Cryocooling Efficiency

Report discusses concept for decreasing compressor power consumed by spacecraft mechanical cryocooler providing 0.5 W of refrigeration at temperature of 61 K at tip of cold finger. Involves connecting thermal strap between radiator or other heat sink at intermediate temperature and stiffening ring located on cold finger about one-third way from base to tip and attains temperature of about 250 K during normal operation. Depending upon specific design, electrical power consumed by mechanical cryocooler reduced by half.

Ross, Ronald G., Jr.↗

Prosthetic Hand For Holding Rods, Tools, And Handles

Prosthetic hand with quick-grip/quick-release lever broadens range of specialized functions available to lower-arm amputee by providing improved capabilities for gripping rods, tools, handles, and like. Includes two stationary lower fingers opposed by one pivoting upper finger. Lever operates in conjunction with attached bracket.

Belcher, Jewell G., Jr.↗

Control of an Axisymmetric Jet Using Vortex Generators

The results of an experimental investigation on the effect of vortex generators, in the form of small tabs at the nozzle exit on the evolution of a jet, are reported in this paper. Primarily tabs of triangular shape are considered, and the effect is studied up to a jet Mach number of 1.8. Each tab is found to produce a dominant pair of counter-rotating streamwise vortices having a sense of rotation opposite to that expected from the wrapping of the boundary layer. This results in an inward indentation of the mixing layer into the core of the jet. A triangular-shaped tab with its apex leaning downstream, referred to as a delta tab, is found to be the most effective in producing such vortices, with a consequential large influence on the overall jet evolution. Two delta tabs, spaced 180 deg apart, completely bifurcate the jet. Four delta tabs stretch the mixing layer into four 'fingers,' resulting in a significant increase in the jet mixing downstream. For six delta tabs the mixing layer distortion settles back to a three finger configuration through an interaction of the streamwise vortices. The tabs are found to be equally effective in jets with turbulent or laminar initial boundary layers. Two sources of streamwise vorticity are postulated for the flow under consideration. One is the upstream 'pressure hill,' generated by the tab, which constitutes the main contributor of vorticity to the dominant pair. Another is due to vortex filaments shed from the sides of the tab and reoriented downstream by the mean shear of the mixing layer. Depending on the orientation of the tab, the latter source can produce a vortex pair having a sense of rotation opposite to that of the dominant pair. In the case of the delta tab, vorticity from the two sources add, explaining the strong effect in that configuration.

Zaman, K. B. M. Q.↗

JOVE Pilot Research Study in Astronomy and Microgravity Sciences

The purpose of this project was to develop hardware and software facilities for evaluating the biomechanical interactions between human hands and space suit gloves. The first task was to measure finger joint angles inside space suit gloves. A preliminary survey identified three potential systems which could be used in the proposed study. In response to the current market situation, a glove for measuring the positions of the hand inside a space suit has been developed. A prototype of the glove has been constructed to demonstrate its sensing technologies. There are two types of sensors in the glove. The positions of the fingers are measured using bend sensors based on the CyberGlove design. This sensor consists of two strain gages mounted to a 0.003 inch thick mylar sheet. The sensor is encapsulated using 0.001 inch kapton film to give it sufficient rigidity. Along gage is used to average the strain generated in the sensor due to bending This average strain produces an output signal proportional to the angle of the bend. The force sensor consists of conductive ink sandwiched between two plastic sheets. An electrode is printed on one of the plastic sheets using silver ink. The resistance of the ink is sensitive to pressure.

Strauss, Alvin M.↗

Applying Space Technology to Enhance Control of an Artificial Arm for Children and Adults With Amputations

The first single function myoelectric prosthetic hand was introduced in the 1960's. This hand was controlled by the electric fields generated by muscle contractions in the residual limb of the amputee user. Electrodes and amplifiers, embedded in the prosthetic socket, measured these electric fields across the skin, which increase in amplitude as the individual contracts their muscle. When the myoelectric signal reached a certain threshold amplitude, the control unit activated a motor which opened or closed a hand-like prosthetic terminal device with a pincher grip. Late in the 1990's, little has changed. Most current myoelectric prostheses still operate in this same, single-function way. To better understand the limitations of the current single-function myoelectric hand and the needs of those who use them, The Institute for Rehabilitation and Research (TIRR), sponsored by the National Institutes of Health (NUH), surveyed approximately 2,500 individuals with upper limb loss [1]. When asked to identify specific features of their current myoelectric prostheses that needed improvement, the survey respondents overwhelmingly identified the lack of wrist and finger movement, as well as poor control capability. However, simply building a mechanism with individual finger and wrist motion is not enough. In the 1960's and 1970's, engineers built a number of more dexterous prosthetic hands. Unfortunately, these were rejected during clinical trials due to a difficult and distracting control interface. The goal of this project, "Applying Space Technology to Enhance Control of an Artificial Arm for Children and Adults with Amputations," was to lay the foundation for a multi-function, intuitive myoelectric control system which requires no conscious thought to move the hand. We built an extensive myoelectric signal database for six motions from ten amputee volunteers, We also tested a control system based on new artificial intelligence techniques on the data from two of these subjects. This data is available to anyone doing myoelectric control research. Its availability is an important contribution to the prosthetics research community, as many researchers do not have access to amputee subjects. Since we collected myoelectric data from subjects' sound arms as well as their residual arms, this database will also prove useful to virtual reality and robotics researchers who want to explore myoelectric-based interfaces between any user and a machine. Currently, one small company (Intelligenta, Inc.) and one university (University of New Brunswick, Canada) are using this myoelectric database under other funding to develop multifunction control systems for prostheses. A prosthetics manufacturer (Liberty Technology, Inc.) is making plans to incorporate the results of their work into an artificial hand capable of several different movements to provide functionality only dreamed of by current myoelectric users. Methods Six adults and four children, all with unilateral, below-elbow amputations served as subjects. Five of the adults (3 male, 2 female, average age 34 years) had amputations due to traumatic injury, while one adult (female, age 32 years) and the four children (3 male, 1 female, average age 13 years) had congenital (i.e. from birth) limb deficiencies.

Atkins, Diane J.↗

Electro-Active Polymer (EAP) Actuators for Planetary Applications

NASA is seeking to reduce the mass, size, consumed power, and cost of the instrumentation used in its future missions. An important element of many instruments and devices is the actuation mechanism and electroactive polymers (EAP) are offering an effective alternative to current actuators. In this study, two families of EAP materials were investigated, including bending ionomers and longitudinal electrostatically driven elastomers. These materials were demonstrated to effectively actuate manipulation devices and their performance is being enhanced in this on-going study. The recent observations are reported in this paper, include the operation of the bending-EAP at conditions that exceed the harsh environment on Mars, and identify the obstacles that its properties and characteristics are posing to using them as actuators. Analysis of the electrical characteristics of the ionomer EAP showed that it is a current driven material rather than voltage driven and the conductivity distribution on the surface of the material greatly influences the bending performance. An accurate equivalent circuit modeling of the ionomer EAP performance is essential for the design of effective drive electronics. The ionomer main limitations are the fact that it needs to be moist continuously and the process of electrolysis that takes place during activation. An effective coating technique using a sprayed polymer was developed extending its operation in air from a few minutes to about four months. The coating technique effectively forms the equivalent of a skin to protect the moisture content of the ionomer. In parallel to the development of the bending EAP, the development of computer control of actuated longitudinal EAP has been pursued. An EAP driven miniature robotic arm was constructed and it is controlled by a MATLAB code to drop and lift the arm and close and open EAP fingers of a 4-finger gripper. Keywords: Miniature Robotics, Electroactive Polymers, Electroactive Actuators, EAP Materials

Bar-Cohen, Y.↗

Flexible Low-Mass Devices and Mechanisms Actuated by Electroactive Polymers

Miniature, lightweight, miser actuators that operate similar to biological muscles can be used to develop robotic devices with unmatched capabilities to impact many technology areas. Electroactive polymers (EAP) offer the potential to producing such actuators and their main attractive feature is their ability to induce relatively large bending or longitudinal strain. Generally, these materials produce a relatively low force and the applications that can be considered at the current state of the art are relatively limited. This reported study is concentrating on the development of effective EAPs and the resultant enabling mechanisms employing their unique characteristics. Several EAP driven mechanisms, which emulate human hand, were developed including a gripper, manipulator arm and surface wiper. The manipulator arm was made of a composite rod with an EAP actuator consisting of a scrolled rope that is activated longitudinally by an electrostatic field. A gripper was made to serve as an end effector and it consisted of multiple bending EAP fingers for grabbing and holding such objects as rocks. An EAP surface wiper was developed to operate like a human finger and to demonstrate the potential to remove dust from optical and IR windows as well as solar cells. These EAP driven devices are taking advantage of the large actuation displacement of these materials but there is need for a significantly greater actuation force capability.

Bar-Cohen, Y↗