Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLEXIBLE GENERATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Heads up display for the Flight Simulator for Advanced Aircraft (FSAA)

A heads-up flight director display designed for a V/STOL lift-fan transport simulation study is described. The pilot's visual flight scene had the heads-up display optically superimposed over the usual out-the-window, video flight scene. The flight director display required the development and integration of a flexible, programmable display generator, graphics assembler, display driver, computer interface system, and special collimating optics for the pilot's flight scene. The optical overlay was realistic because both scenes appeared at optical infinity, and the flexibility of this display device establishes its value as a research tool for use in future flight simulation programs.

Brocker, D. H.↗

Design-Space Exploration for Inverse-Design of Wind Turbine Blades Using Data-Driven Methods

The state-of-the-practice aerodynamic design methods for wind turbine blades is typically based on Blade-Element Momentum (BEM) theory using a pre-designed frozen family of airfoils. The airfoils are themselves typically designed using panel methods. The design of the next-generation of large flexible rotors will need to capture the non-linear aerodynamics and three-dimensional flow to reduce the levelized cost of wind energy. Data-driven methods for aerodynamic design using data generated by computational fluid dynamics offer an attractive alternative to BEM-based methods that captures the non-linear aerodynamics of the component airfoils as well as the root and tip sections. In this work, we develop and demonstrate a framework to "smartly" explore the relevant design space in combination with an appropriate automated CFD pipeline to evaluate the aerodynamics of each design. The design-space exploration framework uses appropriate perturbations to the airfoil shape and induction profile from a baseline shape in combination with the inverse-design using BEM. The resulting designs are evaluated using an automated CFD pipeline using the in-house CFD solver framework "Mercury". We perform verification and validation to establish the capability of the Mercury framework to predict the aerodynamic performance of wind turbines. The CFD simulation of the perturbed blade shapes are optimized to restart from the converged baseline simulation to reduce the computational time. Finally, we demonstrate the design-space exploration technique for the design of the outboard section and the full rotor using perturbations to the shape and operating conditions of the NREL 5-MW turbine.

aerodynamic design methods↗

A Multidisciplinary Approach to Integrated Energy Systems: Advanced Nuclear Plants with Thermal Storage for Dynamic and Flexible Operation in Diverse Markets

Energy supply, distribution, and demand are continuously evolving in accordance with the integration of new power generation sources. In the United States, there is a progressive shift toward incorporating fluctuating energy sources such as wind and solar into the energy mix, alongside the distributed generation. Simultaneously, we are seeing a revolution in consumer technologies such as electric vehicles, energy devices for both residential and commercial use, and industrial processes—all contributing to a fundamental change in energy consumption dynamics. These scenarios have led to huge demand for enhanced flexibility from nuclear power plants (NPPs), requiring them to operate with unprecedented adaptability. Furthermore, advanced NPPs (A-NPPs) could potentially apply to scenarios in which power generation flexibility is prioritized over its current and conventional baseload generation capacity for traditional demand patterns. The present work covers several configurations for coupling nuclear energy production with thermal energy storage (TES). Previous work evaluated systems entailing a simple nuclear-TES configuration that used steam as a heat source for the TES of three different advanced reactors (ARs), but its heat diversion ratio (HDR) for charging was limited. The present work proposes a new configuration that features full decoupling of the nuclear reactor and the power cycle, using reactor coolant (i.e., gas) as a heat source for the TES and offering a theoretically unlimited HDR. This configuration is, however, more complex, as both high- and low-temperature TES (HT-TES and LT-TES) systems are required in order to cover the extended temperature range. Although this configuration imposes certain limitations on the discharge system configuration, it also presents the opportunity to design a more efficient system. For this case in particular, a steam reheat cycle is advantageous. Conventional TES systems take advantage of nominal efficiency when discharging, whereas the reheat cycle in the fully decoupled TES system affords a significant efficiency increase over conventional cases. Material selection, component/equipment sizing, and costing analyses were performed, followed by economic dispatch and size optimization. Dynamic models were developed for the decoupled system in order to generate insights into aspects of off design operation (e.g., drops in cycle efficiency), and these models enable exploration of potential mitigation strategies for addressing such drops. The models also highlight the need to design fail-safes that ensure continuous operational stability and minimize the impact of power ramping on the reactor parameters.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Power Management Solution for Growing Loads at Airport Rental Facilities

Growing electrical loads across airport facilities could expand beyond local grid capacities. Coordinating flexible loads with generation and storage assets can reduce coincident peaks, mitigate costly upgrades, and reduce electricity costs. This report outlines how The Athena Team has developed a suite of tools, resources, and solutions to leverage load flexibility with energy assets to harness this value potential.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ramping Up the Ramping Capability: India's Power System Transition

The Indian power system is going through a period of transformation with plans for renewable energy to be integrated at a large scale over the next decade. Increasing thrust is being given to flexible operation of existing generating resources. Ramping is one of the key attributes of flexibility. With implementation of national level security constrained economic dispatch (SCED), the national power system operator of India (POSOCO) has started to observe occasional constraints in ramping capability obtained from generators under SCED, which could get further aggravated with more variable renewable energy (VRE). This paper focuses on complexities of ramping and the challenges with high shares of renewables in the Indian context.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

NV Energy Large-Scale Photovoltaic Integration Study: Intra-Hour Dispatch and AGC Simulation

The uncertainty and variability with photovoltaic (PV) generation make it very challenging to balance power system generation and load, especially under high penetration cases. Higher reserve requirements and more cycling of conventional generators are generally anticipated for large-scale PV integration. However, whether the existing generation fleet is flexible enough to handle the variations and how well the system can maintain its control performance are difficult to predict. The goal of this project is to develop a software program that can perform intra-hour dispatch and automatic generation control (AGC) simulation, by which the balancing operations of a system can be simulated to answer the questions posed above. The simulator, named Electric System Intra-Hour Operation Simulator (ESIOS), uses the NV Energy southern system as a study case, and models the system’s generator configurations, AGC functions, and operator actions to balance system generation and load. Actual dispatch of AGC generators and control performance under various PV penetration levels can be predicted by running ESIOS. With data about the load, generation, and generator characteristics, ESIOS can perform similar simulations and assess variable generation integration impacts for other systems as well. This report describes the design of the simulator and presents the study results showing the PV impacts on NV Energy real-time operations.

Energy↗

Real-Time Control of Diesel Combustion Quality

Detroit Diesel Corporation (DDC) and ORNL established this CRADA to improve heavy-duty engine efficiency with reduced emissions at relatively extreme operating regimes such has high EGR, low-load, and cold-start, with an emphasis on the application of advanced control strategies. The approach used in this collaborative effort was to include the application of novel analysis and modeling techniques devel-oped from the application of nonlinear dynamics and chaos theory. More specifically, analytical tech-niques derived from these theories were to used to detect, characterize, and control the combustion insta-bilities that are responsible for poor combustion performance and corresponding high emissions. The foundation of this CRADA was established based on ORNL expertise on the fundamentals of ad-vanced combustion operation and experience with nonlinear dynamics and controls in combustion sys-tems. The initial plan was all data generation would be performed at DDC with an agreed upon experi-mental plan formed by both organizations. While numerous experiments were performed at DDC and the data was exchanged with ORNL researchers, the team decided to transfer an engine to ORNL to allow more flexibility and data generation opportunities. A prototype DDC Series 60 with a common rail fuel system was selected and installed at ORNL. DDC and ORNL maintained a strong collaboration throughout much of this project. Direct funding from DOE ended in 2004 and DDC continued to fund at a reduced amount through 2007. This CRADA has not been funded in more recent years but has been maintained active in anticipation of restored funding. This CRADA has led to additional collaborations between DDC and ORNL.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fuel Flexibility: Landfill Gas Contaminant Mitigation for Power Generation

This research project focused on the mitigation of silica damage to engine-based renewable landfill gas energy systems. Characterization of the landfill gas siloxane contamination, combined with characterization of the silica deposits in engines, led to development of two new mitigation strategies. The first involved a novel method for removing the siloxanes and other heavy contaminants from the landfill gas prior to use by the engines. The second strategy sought to interrupt the formation of hard silica deposits in the engine itself, based on inspection of failed landfill gas engine parts. In addition to mitigation, the project had a third task to develop a robust sensor for siloxanes that could be used to control existing and/or future removal processes.

CHP↗

Final CRADA Report ORNL-00-0609, Real-Time Control of Diesel Combustion Quality

Detroit Diesel Corporation (DDC) and ORNL established this CRADA to improve heavy-duty engine efficiency with reduced emissions at relatively extreme operating regimes such has high EGR, low-load, and cold-start, with an emphasis on the application of advanced control strategies. The approach used in this collaborative effort was to include the application of novel analysis and modeling techniques developed from the application of nonlinear dynamics and chaos theory. More specifically, analytical techniques derived from these theories were to used to detect, characterize, and control the combustion instabilities that are responsible for poor combustion performance and corresponding high emissions. The foundation of this CRADA was established based on ORNL expertise on the fundamentals of advanced combustion operation and experience with nonlinear dynamics and controls in combustion systems. The initial plan was all data generation would be performed at DDC with an agreed upon experimental plan formed by both organizations. While numerous experiments were performed at DDC and the data was exchanged with ORNL researchers, the team decided to transfer an engine to ORNL to allow more flexibility and data generation opportunities. A prototype DDC Series 60 with a common rail fuel system was selected and installed at ORNL. DDC and ORNL maintained a strong collaboration throughout much of this project. Direct funding from DOE ended in 2004 and DDC continued to fund at a reduced amount through 2007. This CRADA has not been funded in more recent years but has been maintained active in anticipation of restored funding. This CRADA has led to additional collaborations between DDC and ORNL. The objectives are to: (1) Explore and establish boundaries of high efficiency clean combustion (HECC) modes on a DDC heavy-duty diesel engine; (2) Improve fundamental understanding of combustion instabilities for use in the development of predictive controls and diagnostics; and (3) Develop and evaluate potential control strategies for enabling and/or expanding HECC operation on a multi-cylinder diesel engine.

Wagner, Robert M↗

Impact of Host Flexibility on Selectivity in a Supramolecular Host-Catalyzed Enantioselective aza-Darzens Reaction

A highly enantioselective aza-Darzens reaction (up to 99% ee) catalyzed by an enantiopure supramolecular host has been discovered. To understand the role of host structure on reaction outcome, nine new gallium(III)-based enantiopure supramolecular assemblies were prepared via substitution of the external chiral amide. Despite the distal nature of the substitution in these catalysts, changes in enantioselectivity (61 to 90% ee) in the aziridine product were observed. The enantioselectivities were correlated to the flexibility of the supramolecular host scaffold as measured by the kinetics of exchange of a model cationic guest. Finally, this correlation led to the development of a best-in-class catalyst by substituting the gallium(III)-based host with one based on indium(III), which generated the most flexible and selective catalyst.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Economic Justification of Concentrating Solar Power in High Renewable Energy Penetrated Power Systems

Concentrating solar power (CSP) plants are able to provide both renewable energy and operational flexibility at the same time due to its thermal energy storage (TES). It is ideal generation to power systems lacking in flexibility to accommodate variable renewable energy (VRE) generation such as wind power and photovoltaics. However, its investment cost currently is too high to justify its benefit in terms of providing renewable energy only. In this paper we evaluate the economic benefit of CSP in high renewable energy penetrated power systems from two aspects: generating renewable energy and providing operational flexibility to help accommodating VRE. In order to keep the same renewable energy penetration level during evaluation, we compare the economic costs between the system with a high share of VRE and another in which some part of the VRE generation is replaced by CSP generation. The generation cost of a power system is analyzed through chronological operation simulation over a whole year. The benefit of CSP is quantified into two parts: (1) energy benefit - the saving investment of substituted VRE generation and (2) flexibility benefit - the reduction in operating cost due to substituting VRE with CSP. The break-even investment cost of CSP is further discussed. The methodology is tested on a modified IEEE RTS-79 system. The economic justifications of CSP are demonstrated in two practical provincial power systems with high penetration of renewable energy in northwestern China, Qinghai and Gansu, where the former province has massive inflexible thermal power plants but later one has high share of flexible hydro power. The results suggest that the CSP is more beneficial in Gansu system than in Qinghai. The levelized benefit of CSP, including both energy benefit and flexibility benefit, is about 0.177-0.191 $/kWh in Qinghai and about 0.238-0.300 $/kWh in Gansu, when replacing 5-20% VRE generation with CSP generation.

14 SOLAR ENERGY↗

Flexible wave energy converter

Disclosed herein are flexible wave energy converters that actuate electrical generators with dynamic strain (e.g., flexing, stretching, twisting, distension) to convert wave energy to electrical energy. The flexible wave energy converter utilizes flexible electric generators embedded throughout the wave-energy converter's flexible body.

16 TIDAL AND WAVE POWER↗

Flexible wave energy converter

Disclosed herein are flexible wave energy converters that actuate electrical generators with dynamic strain (e.g., flexing, stretching, twisting, distension) to convert wave energy to electrical energy. The flexible wave energy converter utilizes flexible electric generators embedded throughout the wave-energy converter's flexible body.

30 DIRECT ENERGY CONVERSION↗

Flexible Opportunity Fuels for Process Heat and Steam Generation

The majority of industrial process heating and steam generation is currently fueled by natural gas or coal. Other fuels that are not used throughout industry, such as biomass, anaerobic digester gas and petroleum coke can potentially supplement or replace natural gas and coal in various process heating and steam generation applications. These non-traditional fuel supply options, also known as opportunity fuels, can enhance energy security for industrial facilities by increasing fuel flexibility and reducing or eliminating reliance on traditional fossil fuels. They can also provide significant economic benefits, by reducing fuel costs and improving profit margins. Some fuels may even be available at a negative cost, as owners seek to dispose of waste products that may have energy content.

Lemar, Jr, Paul L.↗

Overview of the Nephele Perturbed Parameter Ensemble for Aerosol‐Cloud Interactions in E3SMv3

Aerosol-cloud interactions (aci) are the leading source of uncertainty in inferring climate sensitivity from the historical record. Earth system models (ESMs) struggle to represent aci because the processes responsible for these phenomena occur at much finer time and space scales than can be resolved by any ESM. Observational constraints provide key benchmarks to test ESMs, but cannot be used alone to fully understand aci processes except in very specific cases where causality is controlled; some degree of modeling is required to infer aci and estimate radiative forcing. Here, we generate and characterize a perturbed parameter ensemble (PPE) in version 3 of the Energy Exascale ESM (E3SMv3). We perturb 25 parameters that govern aci processes over 250 members and integrate the model over present-day and preindustrial aerosol emissions. We find that the process representation in E3SMv3 is flexible and can generate global-mean effective radiative forcings due to aci (ERFaci) ranging from −3.0 to +0.9 W m −2 . The positive ERFaci values simulated by a portion of the PPE are implausible and result from parameter combinations that produce unrealistic top-of-atmosphere energy fluxes. While global-mean cloud droplet number concentration always increases in response to anthropogenic aerosol, cloud liquid water path can both increase and decrease, suggesting that precipitation suppression is not the only aerosol-cloud adjustment represented by E3SMv3. Analysis of which processes control liquid cloud adjustment in the PPE points toward stratiform precipitation processes and aerosol activation, which is consistent with many previous ESMs, as well as the new two-moment convective cloud microphysics in E3SMv3.

Nugent, Jacqueline M. [Univ. of Wyoming, Laramie, ↗

The Value of Increased HVDC Capacity Between Eastern and Western U.S. Grids: The Interconnections Seam Study

The Interconnections Seam Study examines the potential economic value of increasing electricity transfer between the Eastern and Western Interconnections using high-voltage direct-current (HVDC) transmission and cost-optimizing both generation and transmission resources across the United States, proposing, assessing, justifying, and illustrating a major infrastructure change involving two of the worlds largest power grids. The study conducted a multi-model analysis that used co-optimized generation and transmission expansion planning and production cost modeling. Four transmission designs under eight scenarios were developed and studied to estimate costs and potential benefits. The results show benefit-to-cost ratios that reach as high as 2.5, indicating significant value to increasing the transmission capacity between the interconnections under the cases considered, realized through sharing generation resources and flexibility across regions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

End-Use Savings Shapes Measure Documentation: Thermostat Control for Load Shedding in Large Offices

This documentation focuses on a single End-Use Savings Shape measure - thermostat control for load shedding. The thermostat control for load shedding measure applies heating and cooling temperature setpoint offsets for reducing the heating and cooling load during peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start and end times of the peak window, and then adjusts the thermostat cooling and/or heating setpoints by an offset value from original schedules during the peak window to reduce the HVAC or whole building daily peak load. The measure is flexible and allows users to adjust the heating and cooling offset values respectively, but for this study, the adjustment for heating and cooling setpoints are set to -2 degrees Celsius and +2 degrees Celsius by default. The measure provides options of adding rebound control period (default 2 hours) after peak windows for the setpoints to be ramped back to default values, to prevent the system from generating higher peak demand with step changes of setpoints in post-peak periods . This measure is applicable t o large offices equipped with electric HVAC system (either electric cooling only or both electric heating and cooling), which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shedding measure demonstrates 2-5% daily peak demand reduction and 0.068% total site energy savings (3 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗